PrevaLED® Area

www.osram.com/PrevaLED
PrevaLED® Area
Light Engines
Benefits
• Efficiency 150lm/W
• Homogeneous light distribution
• Consistent white light of 3 SDCM
• Seamless: no shadows between
modules
• Poke-in connectors for 0,5mm² to
0,75mm² wire
• Self-cooling
• SELV/non-SELV module for easier
fixture design
• Average lifetime 50.000h L80B10
at Tp = 55°C
• CE, ENEC approval under preparation
• 2250lm on 495 x 245mm
Applications
Dimension (l x w x h):
• Office, Industry
• Floors, Corridors
• Public area
• 495mm x 245mm x 6mm
Typical technical data @rated current*
Product name
Flux
(lm)
CCT
(K)
CRI
SDCM
Vf
(V)
If
(mA)
P (W)
Module
lm/W
Module
PLG2-Ar-2250-830-495x245-DC
2250
3000
> 80
3
43
350
15
150
PLG2-Ar-2250-840-495x245-DC
2250
4000
> 80
3
43
350
15
150
Typical values valid for Tp 45°C
Typical performance @max. current*
Product name
Flux
(lm)
CCT
(K)
CRI
SDCM
Vf
(V)
If
(mA)
P (W)
Module
lm/W
Module
PLG2-Ar-2250-830-495x245-DC
3110
3000
> 80
3
45
525
24
130
PLG2-Ar-2250-840-495x245-DC
3110
4000
> 80
3
45
525
24
130
Typical values valid for Tp 45°C
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to
the actual parameters of each single product which could differ from the typical data.
* Typical value; tolerance for optical and electrical data: +/-10%
PrevaLED Area, 08/2015
page 1 of 7
Optical parameters
#
LED
Pitch
(mm)
PLG2-Ar-2250-830-495x245-DC
60
53mm x 43mm
PLG2-Ar-2250-840-495x245-DC
60
53mm x 43mm
Product name
Minimum and Maximum Ratings
Storage
temperature [ °C ]
Tc max.*
(@ typ. current)
L80 B10 @
Tp 55°C
PLG2-Ar-2250-830-495x245-DC
-35 … 85
80 °C
50,000h
PLG2-Ar-2250-840-495x245-DC
-35 … 85
80 °C
50,000h
Product
,
The modules are designed for operation with OPTOTRONIC® ECG.
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the light engine. The temperature of the LED module must be
measured at the tc-point according to EN60598-1 in thermally settled conditions with a temperature sensor. For exact location of the Tc -point see drawing below (marked as Tc1 and
Tc2).
Temperature derating
104,0%
Relative Flux and Efficacy
102,0%
100,0%
98,0%
Luminous Flux
Efficacy
96,0%
94,0%
92,0%
0
20
40
60
Tcase (oC)
PrevaLED Area, 08/2015
page 2 of 7
80
100
L80B10 lifetime [h] as a function of Tp
Modularity
OT FIT CS (triple current driver – SELV)
PrevaLED Area is designed to be operated by OT FIT SELV drivers in parallel
connection*. Current setting via cable bridge (linear drivers) or selectable output current
connectors (compact drivers).
Linear drivers
OT FIT
27V – 54V
PrevaLED
Area
2250lm
*
OTe
OTe
25/22025/220240/420 CS 240/700
CS
OT FIT 80 / 220240 / 1A6 CS L
OT FIT 50 / 220240 / 1A0 CS L
OT FIT 35 / 220240 / 0A7 CS
1,2A / 1,4A / 1,55A
0,8A / 0,93A / 1,0A
0,5A / 0,6A / 0,7A
290 / 350
/ 420 mA
500 / 600
/ 700 mA
360 x 30 x 21mm
280 x 30 x 21mm
280 x 30 x 21mm
88 x 43 x
29.5 mm
88 x 43 x
29.5 mm
4
(2),3
2
1
2
Final release of modularity under evaluation.
PrevaLED Area, 08/2015
Compact drivers
page 3 of 7
OTi DALI (wide window driver – SELV)
PrevaLED Area is designed to be operated by OTi DALI drivers in parallel connection*.
Current setting via resistor coding (LEDSet) or Tuner4TRONIC software and DALI
magic**.
OTi DALI
27V – 54V
PrevaLED
Area
2250lm
*
OTi DALI 80/220240/1A6 LT2 L
OTi DALI 50/220240/1A4 LT2 L
OTi DALI 35/220240/700 LT2 L
0,6A - 1,55A
0,6A - 1,4A
0,2A – 0,7A
360 x 30 x 21mm
360 x 30 x 21mm
360 x 30 x 21mm
2,3,4
2,3
1,2
Final release of modularity under evaluation.
OT FIT D (single current driver – Non-SELV)
PrevaLED Area is designed to be operated by OT Fit D Non-SELV drivers in serial
connection*.
OT Fit D OT FIT 50/220-240/350 D L
250mA, 54V – 216V
PrevaLED
Area
210 x 30 x 21mm
2250lm
*
1,2,3 (Xs1p)
Final release of modularity under evaluation.
OTi (wide window driver – Non-SELV)
PrevaLED Area is designed to be operated by OTi and OTi DALI drivers in serial or
combined serial-parallel connection*. Current setting via resistor coding (LEDSet) and for
OTi DALI drivers also via Tuner4TRONIC software and DALI magic.
OTi OTi 60/220-240/550
OTi 90/220OTi DALI 60 550
D LT2 L
240V/1A0 D LT2 L
54V-240V
PrevaLED
Area
2250lm
*
120mA – 550mA
250mA – 1000mA
125mA – 550mA
250mA – 1000mA
280 x 30 x 21mm
280 x 30 x 21mm
280 x 30 x 21mm
280 x 30 x 21mm
2,3,4 (Xs1p)
2,3,4,5 (Xs1p)
6 (3s2p)
2,3,4 (Xs1p)
2,3,4,5 (Xs1p)
6 (3s2p)
Final release of modularity under evaluation.
PrevaLED Area, 08/2015
OTi DALI 90 1A0
page 4 of 7
Installation examples
Connection scenarios of the PrevaLED Area module as shown below are based most
common applications. Many other scenarios, e.g. 3 modules by 1s3p or 3s1p, are
possible. If you have any further questions about installation of PrevaLED Area Light
engines, consult your local Osram Sales representative.
1. Parallel connection
600 x 600 luminaire (1s2p configuration)
1200 x 300 luminaire (1s2p configuration)
PrevaLED Area, 08/2015
page 5 of 7
2. Serial connection
600 x 600 luminaire (2s1p configuration)
1200 x 300 luminaire (2s1p configuration)
Drawings
Mounting hole
No mounting hole
PrevaLED Area, 08/2015
page 6 of 7
Safety Information

The LED module itself and all its components must not be mechanically stressed.

When handling the module without use of mountain screws avoid excessive force on the cover as it may be separated from the
PCB.

The integrated mounting and locking mechanism on the cover of the module is intended to center and lock a reflector. Excessive
force on this mechanism may cause permanent damage to the module.
The modules are intended for operation only with matching OPTOTRONIC®
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be
ENEC certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information")
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.

Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards.
Only qualified personnel should be allowed to perform installations.

Pay attention to standard ESD precautions when installing the module.

Important information on photobiological safety is available in the application guide.

Photobiological safety according to IEC 62471, risk group RG1

Max. Voltage U-OUT = 250V for non-isolated products; Max. Voltage U-OUT = 60V for SELV products
Assembly Information

For optimum cooling a thermally conducting layer should be applied between module and heat sink.

Further details and recommendation for mounting can be found in the application guide.
Ordering codes
Product name
PLG2-Ar-2250-830-495x245-DC
PLG2-Ar-2250-840-495x245-DC
*) EAN: Ordering number per single PRODUCT
EAN *
S-Unit **
4052899304055
4052899304086
20 x 1
20 x 1
**) S-Unit: products per shipping unit
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM GmbH
Marcel-Breuer-Straße 6
D-80807 München
Deutschland
www.osram.com
+49 89 6213-0
Sales and technical support is given by the local OSRAM subsidiaries. On our world wide homepage all
OSRAM subsidiaries are listed with complete address and phone numbers.
PrevaLED Area, 08/2015
page 7 of 7