www.osram.com/PrevaLED PrevaLED® Area Light Engines Benefits • Efficiency 150lm/W • Homogeneous light distribution • Consistent white light of 3 SDCM • Seamless: no shadows between modules • Poke-in connectors for 0,5mm² to 0,75mm² wire • Self-cooling • SELV/non-SELV module for easier fixture design • Average lifetime 50.000h L80B10 at Tp = 55°C • CE, ENEC approval under preparation • 2250lm on 495 x 245mm Applications Dimension (l x w x h): • Office, Industry • Floors, Corridors • Public area • 495mm x 245mm x 6mm Typical technical data @rated current* Product name Flux (lm) CCT (K) CRI SDCM Vf (V) If (mA) P (W) Module lm/W Module PLG2-Ar-2250-830-495x245-DC 2250 3000 > 80 3 43 350 15 150 PLG2-Ar-2250-840-495x245-DC 2250 4000 > 80 3 43 350 15 150 Typical values valid for Tp 45°C Typical performance @max. current* Product name Flux (lm) CCT (K) CRI SDCM Vf (V) If (mA) P (W) Module lm/W Module PLG2-Ar-2250-830-495x245-DC 3110 3000 > 80 3 45 525 24 130 PLG2-Ar-2250-840-495x245-DC 3110 4000 > 80 3 45 525 24 130 Typical values valid for Tp 45°C Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. * Typical value; tolerance for optical and electrical data: +/-10% PrevaLED Area, 08/2015 page 1 of 7 Optical parameters # LED Pitch (mm) PLG2-Ar-2250-830-495x245-DC 60 53mm x 43mm PLG2-Ar-2250-840-495x245-DC 60 53mm x 43mm Product name Minimum and Maximum Ratings Storage temperature [ °C ] Tc max.* (@ typ. current) L80 B10 @ Tp 55°C PLG2-Ar-2250-830-495x245-DC -35 … 85 80 °C 50,000h PLG2-Ar-2250-840-495x245-DC -35 … 85 80 °C 50,000h Product , The modules are designed for operation with OPTOTRONIC® ECG. *) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the light engine. The temperature of the LED module must be measured at the tc-point according to EN60598-1 in thermally settled conditions with a temperature sensor. For exact location of the Tc -point see drawing below (marked as Tc1 and Tc2). Temperature derating 104,0% Relative Flux and Efficacy 102,0% 100,0% 98,0% Luminous Flux Efficacy 96,0% 94,0% 92,0% 0 20 40 60 Tcase (oC) PrevaLED Area, 08/2015 page 2 of 7 80 100 L80B10 lifetime [h] as a function of Tp Modularity OT FIT CS (triple current driver – SELV) PrevaLED Area is designed to be operated by OT FIT SELV drivers in parallel connection*. Current setting via cable bridge (linear drivers) or selectable output current connectors (compact drivers). Linear drivers OT FIT 27V – 54V PrevaLED Area 2250lm * OTe OTe 25/22025/220240/420 CS 240/700 CS OT FIT 80 / 220240 / 1A6 CS L OT FIT 50 / 220240 / 1A0 CS L OT FIT 35 / 220240 / 0A7 CS 1,2A / 1,4A / 1,55A 0,8A / 0,93A / 1,0A 0,5A / 0,6A / 0,7A 290 / 350 / 420 mA 500 / 600 / 700 mA 360 x 30 x 21mm 280 x 30 x 21mm 280 x 30 x 21mm 88 x 43 x 29.5 mm 88 x 43 x 29.5 mm 4 (2),3 2 1 2 Final release of modularity under evaluation. PrevaLED Area, 08/2015 Compact drivers page 3 of 7 OTi DALI (wide window driver – SELV) PrevaLED Area is designed to be operated by OTi DALI drivers in parallel connection*. Current setting via resistor coding (LEDSet) or Tuner4TRONIC software and DALI magic**. OTi DALI 27V – 54V PrevaLED Area 2250lm * OTi DALI 80/220240/1A6 LT2 L OTi DALI 50/220240/1A4 LT2 L OTi DALI 35/220240/700 LT2 L 0,6A - 1,55A 0,6A - 1,4A 0,2A – 0,7A 360 x 30 x 21mm 360 x 30 x 21mm 360 x 30 x 21mm 2,3,4 2,3 1,2 Final release of modularity under evaluation. OT FIT D (single current driver – Non-SELV) PrevaLED Area is designed to be operated by OT Fit D Non-SELV drivers in serial connection*. OT Fit D OT FIT 50/220-240/350 D L 250mA, 54V – 216V PrevaLED Area 210 x 30 x 21mm 2250lm * 1,2,3 (Xs1p) Final release of modularity under evaluation. OTi (wide window driver – Non-SELV) PrevaLED Area is designed to be operated by OTi and OTi DALI drivers in serial or combined serial-parallel connection*. Current setting via resistor coding (LEDSet) and for OTi DALI drivers also via Tuner4TRONIC software and DALI magic. OTi OTi 60/220-240/550 OTi 90/220OTi DALI 60 550 D LT2 L 240V/1A0 D LT2 L 54V-240V PrevaLED Area 2250lm * 120mA – 550mA 250mA – 1000mA 125mA – 550mA 250mA – 1000mA 280 x 30 x 21mm 280 x 30 x 21mm 280 x 30 x 21mm 280 x 30 x 21mm 2,3,4 (Xs1p) 2,3,4,5 (Xs1p) 6 (3s2p) 2,3,4 (Xs1p) 2,3,4,5 (Xs1p) 6 (3s2p) Final release of modularity under evaluation. PrevaLED Area, 08/2015 OTi DALI 90 1A0 page 4 of 7 Installation examples Connection scenarios of the PrevaLED Area module as shown below are based most common applications. Many other scenarios, e.g. 3 modules by 1s3p or 3s1p, are possible. If you have any further questions about installation of PrevaLED Area Light engines, consult your local Osram Sales representative. 1. Parallel connection 600 x 600 luminaire (1s2p configuration) 1200 x 300 luminaire (1s2p configuration) PrevaLED Area, 08/2015 page 5 of 7 2. Serial connection 600 x 600 luminaire (2s1p configuration) 1200 x 300 luminaire (2s1p configuration) Drawings Mounting hole No mounting hole PrevaLED Area, 08/2015 page 6 of 7 Safety Information The LED module itself and all its components must not be mechanically stressed. When handling the module without use of mountain screws avoid excessive force on the cover as it may be separated from the PCB. The integrated mounting and locking mechanism on the cover of the module is intended to center and lock a reflector. Excessive force on this mechanism may cause permanent damage to the module. The modules are intended for operation only with matching OPTOTRONIC® To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be ENEC certified. In Europe the declarations of conformity must include the following standards: CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384. Also check for the mark of an independent authorized certification institute. Please see the relevant brochure for more detailed information (see "Related and Further Information") OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation. Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. Pay attention to standard ESD precautions when installing the module. Important information on photobiological safety is available in the application guide. Photobiological safety according to IEC 62471, risk group RG1 Max. Voltage U-OUT = 250V for non-isolated products; Max. Voltage U-OUT = 60V for SELV products Assembly Information For optimum cooling a thermally conducting layer should be applied between module and heat sink. Further details and recommendation for mounting can be found in the application guide. Ordering codes Product name PLG2-Ar-2250-830-495x245-DC PLG2-Ar-2250-840-495x245-DC *) EAN: Ordering number per single PRODUCT EAN * S-Unit ** 4052899304055 4052899304086 20 x 1 20 x 1 **) S-Unit: products per shipping unit Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves. Sales and Technical Support OSRAM GmbH Marcel-Breuer-Straße 6 D-80807 München Deutschland www.osram.com +49 89 6213-0 Sales and technical support is given by the local OSRAM subsidiaries. On our world wide homepage all OSRAM subsidiaries are listed with complete address and phone numbers. PrevaLED Area, 08/2015 page 7 of 7