Technical operation data
Flux
[lm]
@ Tc
35°C*
CCT
[K]
Typ.
CRI
SDCM
Module
P [W]
Module
[lm/W]
@ Tc 35°C
L80 B50 [h] @
Tc 35°C**
1
1000
3000
85
<3
10.1
103
60,000
1
1000
4000
85
<3
8.4
125
60,000
Product name
LEP-1000-830-A
LEP-1000-840-A
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to
the actual parameters of each single product which could differ from the typical data.
* Tolerance for optical and electrical data: +/-10%
**average Lifetime L80B50 (lumen maintenance) only
Attention: due to NON-SELV Concept the Light Engines has to be protected against physical contact in operation
Technical Features
• Dimension (l x w): 280 x 262,5 mm
• Standard wire connection module to ECG and
module to module
• Lumen package: 1000lm
• Various fixation (M3 and M4 screw)
possibilities enable good thermal contact
• Color temperature 3000K and 4000K
• 64 LED in a 8 x 8 grid per single
module 1000lm
1
• Operation by dedicated OTp DALI 80/350 LS
or OTp DALI 80/700 LS
target value
PrevaLED Area, January 2013
page 1 of 6
Minimum and Maximum Ratings
Product
Storage
temperature [ °C ]
Tc max.*
(@ typ. current)
L80 B50 @
Tc max. 75°C
-20 … 85
-20 … 85
75°C
75°C
45,000 h
45,000 h
LEP-1000-830-A
LEP-1000-840-A
The modules are designed for operation with OTp OPTOTRONIC® ECG.
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the light engine. The temperature of the LED module must be measured at the
tc-point according to EN60598-1 in thermally settled conditions with a temperature sensor. For exact location of the Tc -point see drawing below.
Luminous Flux over Tc
102%
Phiv / Phiv Tc 35 C
100%
98%
96%
94%
92%
20
25
30
35
40
45
Tp / C
50
55
60
65
70
Valid for specified typical current
Product name
Typ. Current
Typ. Forward Voltage
LEP-1000-830-A
106 mA
95 V
LEP-1000-840-A
90 mA
93 V
Location of Tc point
Tc point is located at the bottom side in the centre of the module and marked with Tc.
Tc
PrevaLED Area, January 2013
page 2 of 6
Average Lifetime (lumen maintenance) over Tc (case temperature)
valid for specified typical current
Average Lifetime (h)
80000
70000
60000
50000
40000
30000
L80B50
20000
20
25
30
35
40
45
50
55
Tc ( C)
60
65
70
75
80
Estimated average lifetime versus case temperature (indication only)
Cable
For connecting the module OSRAM recommend to use an AWG 20 (0.5mm²) solid wire cable, typical diameter for
cable inclusive insulation ~2mm.
Electrical Connection
On module level
+
-
+
-
String configuration
2 x 32 LED’s for 1000lm
PrevaLED Area, January 2013
page 3 of 6
Wiring of ECG and modules
ECG
+
-
+ module +
-
+ module +
-
+ module +
-
+ module +
-
Example for 4 modules
Current & Power
for different parallel module configuration
LEP-1000-830-A
LEP-1000-840-A
Number of modules
Current
Power*
Current
Power*
2
212 mA
20.2 W
180 mA
16.8 W
3
318 mA
30.3 W
270 mA
25.2 W
4
424 mA
40.4 W
360 mA
33.6 W
5
530 mA**
50.5 W**
450 mA**
42.0 W**
6
636 mA**
60.6 W**
540 mA**
50.4 W**
7
742 mA**
70.7 W**
630 mA**
58.8 W**
8
848 mA
80.8 W
720 mA
67.2 W
* Electrical Power of modules @ Tc 35°C
** Target configuration with upcoming brightness bin
Orientation of Module for regular LED pitch
600 mm x 600 mm
1200 mm x 300 mm
+ - -+
+
+
++
-+
-+
PrevaLED Area, January 2013
page 4 of 6
+- -+
+- -+
+- -+
Drawings
LEP-1000-8x0-A
Poke-In Connector
All dimensions:
General tolerances:
PrevaLED Area, January 2013
mm
+/-0.15 if not specified
page 5 of 6
Safety Information

The LED module itself and all its components must not be mechanically stressed.

When handling the module without use of mountain screws avoid excessive force on the cover as it may be separated from the PCB.

The integrated mounting and locking mechanism on the cover of the module is intended to center and lock a reflector. Excessive
force on this mechanism may cause permanent damage to the module.
The modules are intended for operation only with matching OPTOTRONIC® of OTp series.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be
ENEC certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information")
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.

Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards.
Only qualified personnel should be allowed to perform installations.

Pay attention to standard ESD precautions when installing the module.

Important information on photobiological safety is available in the application guide.
Assembly Information

For optimum cooling a thermally conducting layer should be applied between module and heat sink.

Further details and recommendation for mounting can be found in the application guide.
Ordering codes
Product group
Product name
PrevaLED Area
PrevaLED Area
OPTOTRONIC
OPTOTRONIC
LEP-1000-830-A
LEP-1000-840-A
OTp DALI 80/220-240/350 LS
OTp DALI 80/220-240/700 LS
*) EAN: Ordering number per single product
EAN *
S-Unit *
4008321 991652
4008321991638
4008321 824882
4008321 824905
4
4
25
25
S-Unit: products per shipping unit
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM GmbH
Hellabrunner Strasse 1
D - 81536 München
Deutschland
Sales and technical support is given by the
local OSRAM subsidiaries.
On our world wide homepage all OSRAM
subsidiaries are listed with complete
address and phone numbers.
www.osram.com
+49 89 6213-0
Related and Further Information

PrevaLED® Application Guide
www.osram.com/prevaled-linear

OPTOTRONIC® Technical Guide
www.osram.com/ecg-downloads

OPTOTRONIC® Data Sheets
http://catalog.myosram.com
PrevaLED Area, January 2013
page 6 of 6