COINlight® Pro - CP51 COINlight® Pro CP51

www.osram.de/LED-Systeme
COINlight® Pro - CP51
Preliminary Data Sheet
Benefits




Fits in MR16 luminare fixtures
Usage without additional heat sink possible
- 3.6 W with 50,000h @L70/Ta=25°C
- 7.5 W with 25,000h @L70/Ta=25°C
Life time up-to 12 times longer vs. Halogen lamps
Efficacy up-to 4 times better vs. Halogen lamps
Applications
 Hospitality
- Restaurant & Hotel
- Corridors & Elevator
 Shop
Technical Operating Data
Product
Color
Number
Current
Power
Radiance
of LEDs
[A]*
[W]*
Angle [°]*
Color
Temp.
Lum
Lum.
Intensity
Lum
Lum.
[K]*
[cd]*
[lm]
Flux
CP51-W4F-10-857
white
4
0.51
9,8
36
5700
1600
800
CP51-W4F-8-857
white
3
0.39
7,5
36
5700
1200
600
CP51-W4F-4-857
white
3
0.2
3,6
36
5700
650
320
CP51-W4F-10-827
white
4
0.51
9,8
36
2700
1330
670
CP51 W4F 8 827
CP51-W4F-8-827
white
3
0 39
0.39
75
7,5
36
2700
1000
500
CP51-W4F-4-827
white
3
0.2
3,6
36
2700
540
270
*) All Data are related to the entire module
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data +) Preliminary Data
Technical Features
 Module ready to use with three cables:
 Best efficacy in combination with OSRAM
OPTOTRONIC® 24V constant voltage control gears
- red cable (+ pole)
 Recommendation of OPTOTRONIC® OT8, OT20,
OT75, OTi DALI 75
- black vable (- pole)
- white cable (dimming)
 Cable length 500 mm, cable Ø 1.6 mm/AWG 22
OT DIM
 Color Rendering index CRI typ. 85
 Lifetime 50.000 hrs L70 B50 @ Tc max
 Modul efficacy up to 86 lm/W
 System efficacy up to 76 lm/W
CP51 – 10.12.2012
 Dimmable by pulse width modulation (PWM) and
Page 1 von 5
www.osram.de/LED-Systeme
Minimum and Maximum Ratings
Product
Operating Temperature
Storage Temperature
Voltage Range
Reverse Voltage
Forward Voltage
at Tc-Point [C°]*
[C°]*
[V dc]*
[V dc]*
[V dc]*
CP51-W4F-10-857
-30 … 90
-30 … 90
23 … 25
25
24
CP51-W4F-8-857
-30 … 90
-30 … 90
23 … 25
25
24
CP51 W4F 4 857
CP51-W4F-4-857
-30
30 … 90
-30
30 … 90
23 … 25
25
24
CP51-W4F-10-827
-30 … 90
-30 … 90
23 … 25
25
24
CP51-W4F-8-827
-30 … 90
-30 … 90
23 … 25
25
24
CP51-W4F-4-827
-30 … 90
-30 … 90
23 … 25
25
24
*)) Exceeding
g maximum ratings
g for operating
p
g and storage
g temperature
p
will reduce expected
p
life time or destroyy the LED Module.
Exceeding maximum ratings for operating current will cause hazardous overload and will likely destroy the LED Module.
The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature
sensitive label. For exact location of the Tc-point see drawing below.
Drawing
Viewing Angle
CP51 – 10.12.2012
Page 2 von 5
www.osram.de/LED-Systeme
Safety Information
 The LED module itself and all its components must not be mechanically stressed.
 Assembly must not damage or destroy conducting paths on the circuit board.
 To avoid mechanical damage to the connecting cables, the module should be attached securely to the intended
substrate. Heavy vibration should be avoided.
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically
stabilised power supply protecting against short circuits, overload and overheating.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark
and be ENEC certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute. Please see the relevant brochure for more
detailed information ((see "Related and Further Information").
)
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.
 Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety
standards. Only qualified personnel should be allowed to perform installations.
 Observe correct polarity!
Depending on the product incorrect polarity will lead to emission of red or no light. The module can be destroyed! Correct
polarity immediatelly! (see "reverse voltage", page 2).
 Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not recommended.
Unbalanced voltage drop can cause hazardous overload and damage the LED module.
 Pay attention to ESD steps when mounting the module.
 In case of thermal overload in the application COINlight Pro CP51 intelligent protection system would switch over into
reversible blinking mode. The LED module will not be damaged. Improving heat dissipation by extending the size of the
heat sink or reducing the ambient temperature would provide regular operation mode.
 COINlight Pro works as a three wire system: red cable (pluspole), black cable (minuspole) and a white cable for dimming.
If no dimming is required the white and black cables must be connected to the minus pole.
 A schematic drawing with wiring diagrams for dimming purpose is shown on page 4 "Dimming COINlight PRO CP51“
 The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion.
 Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide suitable
protection against corrosive agents such as moisture and condensation and other harmful elements.
 If the IP rating of the fixture should be higher than IP20, the design of the housing should be according to the IP standards
in the application.
CP51 – 10.12.2012
Page 3 von 5
www.osram.de/LED-Systeme
Dimming COINlight Professional CP51
CP51 is a high end LED module that can be easily used in various combinations with OSRAM power supplies and
light management systems. It can realize dimming functions by connection to a PWM controller.
- Dimming range: 100% to 10% flicker free
- Frequency: 120 - 300 Hz
Three opportunities
1.
Operation with power supply – without dimming function
Configuration A
OT20
OT75
2.
Operation with OT EASY 60 – dimming function
Configuration B
3.
Operation with OT DIM – dimming function
Configuration C
OT20 / OT75
CP51 – 10.12.2012
Page 4 von 5
www.osram.de/LED-Systeme
Assembly Information
 The mounting of the module can be done with M3 screws and should be done on a metal heat sink! Please pay attention to
standard ESD precautions!
 In order to optimize the thermal management the metal surface needs to be clean (free from dirt and oil) and planar for
the best contact with the LED module. Between LED module and mounting surface the use of a thermal interface material
(thin layer of heatconductive paste or thermal foil) is recommended.
 The housing of the COINlight Pro is a primary heat sink. The metal surface increases the cooling effect and prolongs
the service life time.
 The heat sink CPDPHS-51 as accessory part is available for optimized cooling of the module.
Ordering Guide
Product group
Product
EAN*
S-Unit*
COINlight®
g
Pro
CP51-W4F-10-857
4008321 975942
20
COINlight® Pro
CP51-W4F-8-857
4008321 975904
20
COINlight® Pro
CP51-W4F-4-857
4008321 975867
20
COINlight® Pro
CP51-W4F-10-827
4008321 975928
20
COINlight® Pro
CP51-W4F-8-827
4008321 975881
20
COINlight® Pro
CP51-W4F-4-827
4008321 975843
20
Heat sink
CPDPHS-51
4008321 975829
16
*) EAN: Ordering number per single module
S-Unit: Modules per shipping unit
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM AG
Hellabrunner Strasse 1
Sales and technical support is given by the local
D - 81536 München Germany
OSRAM subsidiaries.
www.osram.com
On our world wide homepage all OSRAM
subsidiaries are listed with complete address
Phone: +49 (0)89 6213-0
and phone numbers.
Related and Further Information

A new approach to light

OSRAM LED Systeme

OPTOTRONIC® Technical Guide


OPTOTRONIC® Data sheets
Eulumdat Files

New standards for LED control gear
CP51 – 10.12.2012
153 S006 GB
www osram de/led systeme
www.osram.de/led-systeme
130 T008 DE www.osram.de/evg-downloads
http://catalog.myosram.com
www.osram.de/led-systeme-downloads
www.osram.de/evg-downloads
Page 5 von 5