Data sheet COINlight-OSTAR CO06A (application note included)

www.osram.com/LED-Systems
COINlight-OSTAR® - CO06A
Data Sheet
Benefits
Picture for
Datasheet
is missing
!!!

Powered by OSRAM OSTAR® - Lighting

38° optics for wide flood

Available in white, 3 colour temperatures

Low energy consumption
Applications

Downlight

Shop lighting

Orientation and accent lighting
Technical Operating Data
Product
Color
Number
of LEDs
Voltage
[V DC]*
Power
[W]*
Current
[A]*
Radiance
Angle [°]*
Wavelength [nm]
Color Temp [K]*
Lum. Intensity
[cd]*
CO06A-W4-854
white
1
24
12,0
0,5
38
5400 K
450
CO06A-W3-854
white
1
24
12,0
0,5
38
5400 K
310
CO06A-W4-847
white
1
24
12,0
0,5
38
4700 K
450
CO06A-W3-847
white
1
24
12,0
0,5
38
4700 K
310
CO06A-W4-730
white
1
24
12,0
0,5
38
3000 K
330
CO06A-W3-730
white
1
24
12,0
0,5
38
3000 K
240
*) All Data are related to the entire module
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data.
+) Preliminary Data
Technical Features
 Powered by one high perfomance OSRAM
OSTAR® - Lighting
 Parallel connection of up to 6 modules with the
power feed in the center to one OT75
 Diameter of LED module: Ø 50 mm
 Dimmable by pulse width modulation (PWM)
 Dimension of COINlight-OSTAR® similar to
 Cable length 500 mm, cable Ø 1.6 mm/AWG 22
DECOSTAR®
 Cable length 500 mm, cable Ø 0,2 mm²/AWG
 38° viewing angle for wide flood
24
 Operation only with OPTOTRONIC® power
supplies: OT20, OT20S, OT75, OT75E
 Only parallel connection allowed
CO06A - 25.01.2011
Page 1 of 4
 Up to 60,000 h lifetime
Minimum and Maximum Ratings
Product
Operating Temperature
at Tc-Point [ °C ] *
Storage Temperature
[ °C ] *
Voltage Range
[ V dc ] *
Reverse Voltage
[ V dc ] *
CO06A-W4-854
-30 ... 105
-30 ... 105
23 ... 25
25
CO06A-W3-854
-30 ... 105
-30 ... 105
23 ... 25
25
CO06A-W4-847
-30 ... 105
-30 ... 105
23 ... 25
25
CO06A-W3-847
-30 ... 105
-30 ... 105
23 ... 25
25
CO06A-W4-730
-30 ... 105
-30 ... 105
23 ... 25
25
CO06A-W3-730
-30 ... 105
-30 ... 105
23 ... 25
25
*)
Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Module.
The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature
sensitive label. For exact location of the Tc-point see drawing below.
Drawings
Drawing is missing !!!
CO06A - 25.01.2011
Page 2 of 4
Safety Information
 The LED module itself and all its components must not be mechanically stressed.
 Assembly must not damage or destroy conducting paths on the circuit board.
 To avoid mechanical damage to the connecting cables, the module should be attached securely to the intended substrate. Heavy
vibration should be avoided.
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically stabilised power
supply protecting against short circuits, overload and overheating.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be ENE
certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61374-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61374-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information")
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.
 Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only
qualified personnel should be allowed to perform installations.
 Observe correct polarity!
Depending on the product incorrect polarity will lead to emission of red or no light. The module can be destroyed! Correct polarity
immediatelly! (see "reverse voltage", page 2)
 Parallel connection is highly recommended as safe electrical operation mode.
Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module.
 Pay attention to standard ESD precautions when installing the module.
 Please ensure that the power supply is of adequate power to operate the total load.
 In case of thermal overload in the application COINlight-OSTAR® intelligent protection system would switch over into reversible blinki
mode. The LED module will not be damaged. Improving heat dissipation by extending the size of the heat sink or reducing the ambien
temperature would provide regular operation mode.
 Electrical contact is achieved with the contact cables. One COINlight-OSTAR® can be operated on one OT20 or OT20S. A maximum
6 modules can be installed parallel on one OPTOTRONIC 75W. COINlight-OSTAR® cannot be operated with OT DALI 25/220-240/24
RGB as the intelligent protection system of the module is not supported.
 COINlight-OSTAR® works as a three wire system: red cable (pluspole), black cable (minuspole) and a white cable for dimming.
 A schematic drawing with wiring diagrams for dimming purpose is shown in the separate application note: "Dimming COINlightOSTAR®".
 The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion.
 Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide suitable protection again
corrosive agents such as moisture and condensation and other harmful elements.
 If the IP rating of the fixture should be higher than IP20, the design of the housing should be according to the IP standards in the
application.
CO06A - 25.01.2011
Page 3 of 4
Assembly Information
 The mounting of the module has to be done on a metal heat sink!
 In order to optimise the thermal management the metal surface needs to be clean (free from dirt and oil) and planar for the best conta
with the LED module.
 The housing of the COINlight-OSTAR® is a primary heat sink. The metal surface increases the cooling effect, prolongs the service life
time and increase luminous intensity.
 Heat sink COHS-50 as accessory part available for optimized cooling of the module.
Ordering Guide
S-Unit *
Productgroup
Productname
EAN *
COINlight-OSTAR®
CO06A-W4-854
4008321231697
20
COINlight-OSTAR®
CO06A-W3-854
4008321231451
20
COINlight-OSTAR®
CO06A-W4-847
4008321231758
20
COINlight-OSTAR®
CO06A-W3-847
4008321231512
20
COINlight-OSTAR®
CO06A-W4-730
4008321231819
20
COINlight-OSTAR®
CO06A-W3-730
4008321231574
20
*) EAN: Ordering number per single module
S-Unit: Modules per shipping unit
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM GmbH
Hellabrunner Strasse 1
D - 81536 München
Germany
www.osram.com
+49 (0)89 6213-0
Sales and technical support is given by the
local OSRAM subsidiaries.
On our world wide homepage all OSRAM
subsidiaries are listed with complete
address and phone numbers.
Related and Further Information
 OPTOTRONIC® Data Sheets
 The new dimension of light
 OPTOTRONIC® Technical Guide
 Application Note: Dimming COINlight-OSTAR™
 New standards for LED control gear
 Data sheet Heat sink COHS-50
CO06A - 25.01.2011
Page 4 of 4
http://catalog.myosram.com
153 S006 GB
www.osram.com/led-systems-downloads
130 T008 GB www.osram.com/ecg-downloads
130 W011 GB
www.osram.com/ecg-download
www.osram.com/led-systems-downloads
Application note
Dimming COINlight-OSTAR®
0. Products
COINlight-OSTAR®
OSRAM OPTOTRONIC
POWER SUPPLY
Configuration
OT 20/24
A
OT 20S/24
A
OT 75/24
A
OT 75E/24
A
OT 60 EASY
B
OT DIM
C
OTi DALI DIM
OT RGB DIM
Without illustration
OT DMX RGB DIM
OT DMX 3x1 RGB DIM
combination chart
COINlight-OSTAR® is a high end LED module, that can be
easily used in various combinations with OSRAM power
supplies and control systems.
Dimming COINlight-OSTAR® benefits:
- Wide dimming range from 0 – 100%
- Linear dimming characteristic
- No noise generation
1. Operation with power supply (no dimming)
Application note – Dimming COINlight-OSTAR
2. Operation with OT EASY 60 (dimmable)
Use of COINlight-OSTAR® in basic light management systems with OT EASY 60 which consists
power supply and control in one device.
3. Operation with OT DIM (dimmable)
Operation of COINlight-OSTAR® with a power supply in combination with 1-channel dimming
device.
Page 2 of 2