SKKE 600F Absolute Maximum Ratings Symbol Conditions Values Unit Tc = 85 °C 360 A Tc = 100 °C 305 A Tj = 25 °C 7000 A Tj = 150 °C 5800 A Tj = 25 °C 245000 A²s Tj = 150 °C 168200 A²s VRSM 1200 V VRRM 1200 V -40 ... 150 °C -40 ... 125 °C 1 min 4000 V 1s 4800 V Diode IFAV IFSM i2t SEMIPACK® Fast Diode Modules sin. 180 Tj = 150 °C 10 ms 10 ms Tj Module Tstg SKKE 600F Visol Features Characteristics • CAL (controlled axial lifetime) technology, patent No. 43 10 44 • Heat transfer through aluminium oxide DCB ceramic isolated metal baseplate • Small recovered charge • Fast & soft recovery CAL diodes • UL recognized, file no. E 63 532 Symbol Typical Applications* • Freewheeling diodes for IGBT • Freewheeling diode for inductive loads • Brake choppers • Inverters and DC choppers • AC motor control • Boost choppers • up to 20 kHz a.c.; 50 Hz; r.m.s. Conditions min. typ. max. Unit Diode VF Tj = 25 °C, IF = 600 A, 2.5 V V(TO) Tj = 150 °C, 1.2 V rT Tj = 150 °C, 1.9 mΩ Tj = 25 °C 4 mA Tj = 150 °C 30 mA IR Qrr IRRM trr Err Rth(j-c) VR = VRRM Tj = 150 °C IF = 600 A Tj = 150 °C di/dtoff = 4000 A/µs Tj = 150 °C VR = 600 V Tj = 150 °C cont. per chip 80 µC 280 A 0.78 µs 21 mJ 0.062 K/W per module K/W Module Rth(c-s) chip 0.038 K/W module K/W Ms 3 5 Mt 2.5 5 Nm 5 * 9,81 m/s² a w 330 Nm g SKKE © by SEMIKRON Rev. 5 – 17.02.2015 1 SKKE 600F Fig. 1: Typ. recovery charge vs. current decrease Fig. 2: Peak recovery current vs. current decrease Fig. 3: Transient thermal impedance vs. time Fig. 4: Forward characteristics Fig. 5: Surge overload current vs. time Fig. 6: Typ. turn-off energy dissipation per pulse 2 Rev. 5 – 17.02.2015 © by SEMIKRON SKKE 600F SEMITRANS 4 SKKE This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX * The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff. © by SEMIKRON Rev. 5 – 17.02.2015 3