SEMiX501D17Fs DataSheet

SEMiX501D17Fs
Absolute Maximum Ratings
Symbol
Conditions
Values
Unit
Tc = 85 °C
494
A
Tc = 100 °C
417
A
Tj = 25 °C
2740
A
Tj = 150 °C
2140
A
Tj = 25 °C
37538
A²s
Tj = 150 °C
22898
A²s
VRSM
1700
V
VRRM
1700
V
-40 ... 150
°C
-40 ... 125
°C
1 min
4000
V
1s
4800
V
Rect. Diode
ID
IFSM
i2t
SEMiX® 13
Tj = 150 °C
sinus 180°
10 ms
10 ms
Tj
Bridge Rectifier Module
(uncontrolled)
Module
Tstg
Visol
SEMiX501D17Fs
AC sinus 50Hz
Characteristics
Features
• Terminal height 17 mm
• Chips soldered directly to isolated
substrate
• UL recognised file no. E63532
Typical Applications*
• Fast Input Bridge Rectifier for AC/DC
motor control
• Power supply
• High frequency applications
Symbol
Conditions
min.
typ.
max.
Unit
V
Rectifier Diode
VF
Tj = 25 °C, IF = 300 A, chiplevel
1.90
V(TO)
Tj = 125 °C, chiplevel
1.1
V
rT
Tj = 125 °C, chiplevel
2.7
mΩ
IRD
Tj = 125 °C, VRD = VRRM
Rth(j-c)
sin. 180
per diode
14.4
mA
0.165
K/W
K/W
Module
RCC'+EE'
Rth(c-s)
res., terminal-chip
TC = 25 °C
0.7
mΩ
TC = 125 °C
1
mΩ
0.04
K/W
per chip
K/W
per module
Ms
to heat sink (M5)
3
5
Nm
Mt
to terminals (M6)
2.5
5
Nm
a
5 * 9,81
m/s²
w
350
g
Temperature Sensor
R100
B100/125
Tc=100°C (R25=5 kΩ)
R(T)=R100exp[B100/125(1/T-1/T100)]; T[K];
493 ± 5%
Ω
3550
±2%
K
D
© by SEMIKRON
Rev. 3 – 04.02.2014
1
SEMiX501D17Fs
Fig. 4L: Power dissipation per module vs. direct current
Fig. 4R: Power dissipation per module vs. case
temperature
Fig. 6: Transient thermal impedance vs. time
Fig. 7: On-state characteristics
Fig. 8: Surge overload current vs. time
2
Rev. 3 – 04.02.2014
© by SEMIKRON
SEMiX501D17Fs
spring configuration
SEMiX 13
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX
* The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested
for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is
subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff.
© by SEMIKRON
Rev. 3 – 04.02.2014
3