SEMiX501D17Fs Absolute Maximum Ratings Symbol Conditions Values Unit Tc = 85 °C 494 A Tc = 100 °C 417 A Tj = 25 °C 2740 A Tj = 150 °C 2140 A Tj = 25 °C 37538 A²s Tj = 150 °C 22898 A²s VRSM 1700 V VRRM 1700 V -40 ... 150 °C -40 ... 125 °C 1 min 4000 V 1s 4800 V Rect. Diode ID IFSM i2t SEMiX® 13 Tj = 150 °C sinus 180° 10 ms 10 ms Tj Bridge Rectifier Module (uncontrolled) Module Tstg Visol SEMiX501D17Fs AC sinus 50Hz Characteristics Features • Terminal height 17 mm • Chips soldered directly to isolated substrate • UL recognised file no. E63532 Typical Applications* • Fast Input Bridge Rectifier for AC/DC motor control • Power supply • High frequency applications Symbol Conditions min. typ. max. Unit V Rectifier Diode VF Tj = 25 °C, IF = 300 A, chiplevel 1.90 V(TO) Tj = 125 °C, chiplevel 1.1 V rT Tj = 125 °C, chiplevel 2.7 mΩ IRD Tj = 125 °C, VRD = VRRM Rth(j-c) sin. 180 per diode 14.4 mA 0.165 K/W K/W Module RCC'+EE' Rth(c-s) res., terminal-chip TC = 25 °C 0.7 mΩ TC = 125 °C 1 mΩ 0.04 K/W per chip K/W per module Ms to heat sink (M5) 3 5 Nm Mt to terminals (M6) 2.5 5 Nm a 5 * 9,81 m/s² w 350 g Temperature Sensor R100 B100/125 Tc=100°C (R25=5 kΩ) R(T)=R100exp[B100/125(1/T-1/T100)]; T[K]; 493 ± 5% Ω 3550 ±2% K D © by SEMIKRON Rev. 3 – 04.02.2014 1 SEMiX501D17Fs Fig. 4L: Power dissipation per module vs. direct current Fig. 4R: Power dissipation per module vs. case temperature Fig. 6: Transient thermal impedance vs. time Fig. 7: On-state characteristics Fig. 8: Surge overload current vs. time 2 Rev. 3 – 04.02.2014 © by SEMIKRON SEMiX501D17Fs spring configuration SEMiX 13 This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX * The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff. © by SEMIKRON Rev. 3 – 04.02.2014 3