UP1-FZZZ-FSG

End of Life - Not Recommended for New Designs
MicroPAC
®
C
S
US
C
NRTL
US
AC-DC Power Supply
Features
• High efficiency up to 92%
• Output series capability
• Small Size
• Output current sharing
• High power density (25 W/In3)
• MicroPAC to MicroPAC Current sharing
• Up to 1300 W (Configuration dependent)
• Optional power shed capability
• Low power standby mode (Green mode)
• Over temperature warning
• Universal Input ((47-63 Hz) (400 Hz) (85 to 264 Vac)
• Over temperature shut down
• DC Input (120 – 300 Vdc)
• Intelligent fan control
• Up to 4 isolated outputs
• Field replaceable fan
• Standard 12 V, 14 V, 24 V, 28 V, 36 V & 48 V output
• Individual output enable / disable
• Aux isolated 5 V @ 500 mA bias standby supply
• All output enables / disable capability
• Output parallel capability
• TTL control signals
• All customer interface signals are isolated
• Visual LED display panel
• External Serial interface and GUI (Part Number CI-01)
Product Description
The MicroPAC is the first Westcor product to utilize Vicor’s VI Chip technology. The power supply uses
BCM modules to provide up to 4 isolated semi regulated output voltages of 12, 14, 24, 28, 36 and 48 Vdc and
up to 1300 W of continuous power in a very small highly efficient package. The isolated outputs may be placed in parallel/series
configurations and for applications requiring higher power levels MicroPAC power supplies can be configured in arrays up to
several KW. Safety agency approvals limit the configured output voltages to 60Vdc. Configurations and applications where output
voltages are greater than 60Vdc are non-SELV.
This factory configurable rugged power supply supports a wide range of customer power requirements and is especially suited for
distributed power architectures. The design offers a small flexible cost effective solution for applications requiring Power Factor
Correction, high efficiency and power density even in environmentally challenging conditions.
Part Numbering
UP
a
–
b
b
b
b
Output Configuration
MicroPAC
Constant
Fill in character from chart below for each output
b =
Number of
outputs,
1 to 4
Vout
Watts
A
12
300
B
12
600
C
12
D
12
b =
Vout
Watts
G
48
325
H
48
650
900
I
48
975
1200
J
48
1300
E
24
600
K
F
24
1200
T
36
28
900
600
P
14
300
U
28
1200
Q
14
600
M
[a]
[a]
Z
[b]
[b]
R
14
900
S
14
1200
[a] M defines a slot with an air block filler, no BCM board
c
d
e
Cooling
Interface Customer Option
Non-Safety Related
RoHS
Compliant
S = Standard (TTL levels)
Signaling and Control
G = RoHS
N = Non-RoHS
F = Fan
L = -40C Fan
M = Confrontal Coat
Examples:
UP1-FZZZ-FSG
Denotes a single output of 24 V 1200 W
with a standard fan, standard TTL signaling and control,
RoHS compliant
UP4-AAAA-LSN
Denotes 4 output unit, each output is 12 V 300 W.
The fan is a -40°C capable unit, standard TTL signaling,
and the unit is non-RoHS
[b] Z indicates the slot is populated with a BCM board that is
connected in series or parallel with the adjacent slot
MicroPAC
Rev 1.2
vicorpower.com
Page 1 of 5
9/2013
800 735.6200
End of Life - Not Recommended for New Designs
Specifications
Input
Input Voltage
85 – 264 Vac
DC Rating: 120 Vdc – 300 Vdc
External Fuse
(¼” x 1¼”) Cooper Bussmann,
ABC-15,
rated 15 A
Littelfuse,
505 series,
rated 16 A / 500 Vac
(5 x 20 mm) Littelfuse,
216 series,
rated 16 A
(¼” x 1¼”) Littelfuse,
505 series,
rated 16 A / 500 Vdc
Frequency
47 ~ 400 Hz
Inrush Current
30 A Peak
Efficiency
≥92% @ Full load @ 25°C
ambient 48 V output
Power factor (115-230 Vrms)
.99 / .96 typ. Meets EN61000-3-2
Turn-on time
Ac-on: 1 sec typ. 1.5 sec maximum
Conducted EMI
EN55022 Class B Information technology equipment — Radio
disturbances characteristics — Limits and methods of measurement
BS EN55022:1998; CISPR 22:1997, incorporating corrigendum
Harmonic distortion
Meets IEC 61000-3-2
Isolation
Meets IEC 60950
Leakage current
< 3.5 mA @ 264 Vac @ 63 Hz
Hold up time
20 mS typical
Warranty
2 Years
≥91% @ Full load @ 25°C
ambient 12 V output
Output
Number of outputs
1 to 4
Normal output voltages
12 V, 14 V, 24 V, 28 V, 36 V and 48 V (contact factory for details)
Maximum output current
100 A @ 12 V
Auxiliary output
5 V @ 0.5 A 50 mV p-p
85.71A @ 14 V
[27 A @ 48 V]
48 V +/- 2%
Voltage regulation
12 V +/- 3%
14 V +/- 3% typ.
Ripple and noise
(20 MHz bandwidth) (full load)
12 V output (150 mV ~ 300 mV p-p) typ.
14 V output (150 mV ~ 300 mV p-p) typ.
48 V output (600 mV - 900 mV) typ.
Current sharing accuracy
5 to 10%
Short circuit protection
“Fold-Back” Technique
Over voltage protection
12 V output set point 12.5 V typical
Thermal protection
All outputs disabled when internal temperature exceeds safe operating
Maximum load
12 V up to 1200 W
Maximum load
48 V up to 1300 W
Maximum load
5.0 V Aux up to 2.5 W
Maximum load capacitance
1000 µF per 12 V output
48 V modules 50 V typical
14 V up to 1200 W
1000 µF per 14 V output
MicroPAC
Rev 1.2
vicorpower.com
Page 2 of 5
9/2013
800 735.6200
100 µF per 48 V output
End of Life - Not Recommended for New Designs
Specifications cont.
Environmental
Storage temperature
Operating temperature
Functional shock
-40°C ~ +85°C
-20°C ~ +55°C (Extended temperature range is available; -40°C to +55°C) (-40°C to 65°C 50% load)
-20°C ~ +65°C @ 50% load
MIL-STD 810F Method 516.5 procedure 1,
terminal peak saw-tooth wave, 40G 11 mS
Vibration
Mil-STD 810G for minimum integrity vibration
Humidity
95% non condensing
Cooling
Fan cooled (field replaceable) temperature speed control
Electromagnetic Compatibility
EN61000-6-1n European General EMC Immunity
IEC 61000-4-11 [50 Hz]
Voltage Dips 30% for 0.5 prd, pc C Voltage Interrupts (pc C)
IEC 61000-4-4 [TRANSIENT]
EFT / Burst ± 1 kV AC leads ± 500 V DC leads.
5 / 50 nsec 5 kHz rep rate (pc B)
IEC 61000-4-5 [SURGE]
Power line Surge AC in ± 2 kV CM ± 1 kV DM DC in
± 500 V CM & DM 1.2 / μSec (pc B)
EN 61000-4-6 [0.15 to 80 MHz]
RF Common Mode Input leads, AC & DC leads,
CDN 150 kHz to 80 MHz, 3 Vrms with 80% AM @1 kHz (pa A)
EN 61000-4-2 [ELECTROSTATIC]
Electrostatic Discharge ± 4 kV Contact ± 8 kV Discharge (pc B)
EN 61000-4-3
RF E-Field 80 MHz to 1 GHz 3 V/m with 80% AM @ 1 kHz (pc A)
EN 61000-4-8
Power Freq H-Field 3A / M @ 50 Hz (pa A)
Reliability
FIT
3,449 FITS, 50% duty cycle at 25°C ambient; 45% RH +/- 10%, 90% total ouput load;
any specified input voltage; sea level operation
Service life
5 Years
Safety & Regulatory
UL / cUL (recognized)
UL 60950-1:2007 CAN C22.2 No. 60950-1-07
EN
EN 60950-1/A12:2011
IEC
60950-1-2005 2 Ed. +A1:2009
Please see User Guide for more information.
MicroPAC
Rev 1.2
vicorpower.com
Page 3 of 5
9/2013
800 735.6200
Figure 1 — Physical Dimensions and Electrical Connections
MicroPAC
Rev 1.2
vicorpower.com
Page 4 of 5
9/2013
800 735.6200
0
4.
USE SCREW #6-32 . MAXIMUM INTRUSION OF SCREW INTO CHASSIS
FROM OUTSIDE SURFACE OF CHASSIS = .125"
USE CRIMP TOOL FROM MOLEX P/N - 11-01-0199 FOR J5
3.2 .
4
2X CUSTOMER
MOUNTING
USE CRIMP TOOL FROM FCI P/N - HT-151 OR RCY21151 FOR J2
2 . WESTCOR MATING CONNECTORS KIT P/N 19-130066.
INTERPRET DRAWING PER ANSI Y14.5-1994.
5.800
3.1 .
1.
NOTES: UNLESS OTHERWISE SPECIFIED
0
.500
AIR FLOW
1.329
0
2X 1.329
2X 5.863
2X 6.486
7.38
7.44
7.45
CH-1
.312
2X 1.325
0
.287
.502
.644
CH-2
CH-3
CH-4
A
3.542
4.00
3.688
.19
0
4X CUSTOMER
MOUNTING
4
SEE DETAIL-A
FOR PINOUT
4X CUSTOMER
MOUNTING
4
4
6
8
10
12
5
7
9
11
DETAIL A
SCALE 8 : 1
4
3
J2
0
0
0
1.000
2 , 3.1
2X .500
1.72
SEE NOTE 2
1.329
1
2X CUSTOMER
MOUNTING
ENABLED/DISABLED - 3
GENERAL SHUTDOWN
FAN FAULT
ENABLED/DISABLED - 2
NOT CONNECTED
ENABLED/DISABLED - 4
8
9
10
11
12
STANDBY MODE
OVER TEMPERATURE WARNING
5
A/C OKAY
ENABLED/DISABLED - 1
4
7
0 VOLT
3
6
+5 VOLT
.500
2
FUNCTION
INTERFACE CONNECTOR
3.2
CHASSIS GROUND
NEUTRAL
LIVE
J5
CHASSIS
GROUND
0
1
PIN NUMBER
4
USE SCREW SIZE
#6-32
End of Life - Not Recommended for New Designs
Mechanical Drawings
5.800
3.502
3.356
0
End of Life - Not Recommended for New Designs
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are
used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is
not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS
ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
MicroPAC
Rev 1.2
vicorpower.com
Page 5 of 5
9/2013
800 735.6200