FlatPAC™ 50 to 600 Watts Autoranging, AC-DC Switchers Features • • • • • • • • • • • • • • • RoHS compliant (VE versions) Microcontroller architecture Inputs: 115/230 Vac autoranging Meets FCC Part 15, EN55022, Class B conducted emissions 80 – 90% efficiency Any output: 1 to 95 Vdc Module enable/disable (except LU series) UL, TÜV, CE marked Remote sense and current limit BUS OK and AC OK (except LU series) 40 ms ride-through time OVP and thermal shutdown 1 output; up to 200 W 1 or 2 outputs; up to 400 W 1, 2, or 3 outputs; up to 600 W Configuration Chart Typical Model: VI-RU 0 1 1 - E U U U Input 115/230 Vac Output 1: 5 Vdc at 200 W 2: 12 Vdc at 200 W 3: 12 Vdc at 200 W Input Characteristics 90–132/180–264 Vac U = Autoranging Substitute VE– for VI– for RoHS compliant versions Configuration Total Power # of Converters Dimensions Single Output VI-LU - 50 – 200 W 1 VI-MU - 200 – 400 W 2 VI-NU - 300 – 600 W 3 9.25" x 2.5" x 1.37" (234,8 x 124,5 x 34,8 mm) 9.25" x 4.9" x 1.37" (234,8 x 124,5 x 34,8 mm) 9.25" x 7.3" x 1.37" (234,8 x 185,4 x 34,8 mm) Dual Output Product Highlights If you’re looking for the convenience of a complete, low profile, agencyapproved switching power supply, look no further. The FlatPAC combines Vicor’s workhorse VI-200 family of DC-DC converters with a modular package and front-end subassembly to provide from 50 to 600 W of output power from one to three outputs. A flat plate heat sink for use in conduction cooled applications may be specified as an alternate to the standard finned version by adding “CC” to the end of the model number. Vicor’s FlatPAC is also available with a current controlled output using BatMod converter modules of 12, 24, or 48 Vdc outputs. This option is specified by appending “BM” or “BC” (for conduction cooled versions) to the end of the FlatPAC model number. VI-PU - 100 – 400 W 2 VI-QU - 150 – 600 W 3 150 – 600 W 3 Triple Output VI-RU - 9.25" x 7.3" 1.37" (234,8 x 185,4 x 34,8 mm) Output Voltage Z=2V W = 5.5 V M = 10 V N = 18.5 V K = 40 V D = 85 V Y = 3.3 V V = 5.8 V 1 = 12 V 3 = 24 V 4 = 48 V B = 95 V 0=5V T = 6.5 V P = 13.8 V L = 28 V H = 52 V X = 5.2 V R = 7.5 V 2 = 15 V J = 36 V F = 72 V Product Grade Temps. °C Grade E= C= I = Operating Storage 0 to +85 0 to +85 –30 to +85 –20 to +100 –20 to +100 –55 to +100 Output Power/Current VOUT ≥5 V Y = 50 W X = 75 W W = 100 W V = 150 W U = 200 W Temperatures apply to product case. VOUT < 5 V Y = 10 A X = 15 A W = 20 A V = 30 A U = 40 A Output Power/Current Mixing VI-200 and BatMods in a single FlatPAC is not permissible. The FlatPAC’s contemporary design allows us to configure your order quickly and provide rapid turnaround on standard models. It is truly a complete power solution, enabling you to spend more time designing your system and less time worrying about how to power it. 9.25" x 4.9" x 1.37" (234,8 x 124,5 x 34,8 mm) 9.25" x 7.3" x 1.37" (234,8 x 185,4 x 34,8 mm) VOUT ≥5 V W= 100 W V = 150 W U = 200 W S = 300 W Q = 400 W VOUT < 5 V W= 20 A V = 30 A U = 40 A S = 60 A Q = 80 A Output Power/Current VOUT ≥5 V S = 300 W P = 450 W M = 600 W VOUT < 5 V S = 60 A P = 90 A M = 120 A Options BC = BatMod/Conduction Cooled BM = BatMod FlatPAC™ Rev 1.6 vicorpower.com Page 1 of 6 01/2015 800 927.9474 CC = Conduction Cooled FlatPAC™ SPECIFICATIONS (typical at 25°C, nominal line and 75% load, unless otherwise specified) INPUT SPECIFICATIONS Parameter Min Typ AC line input Autoranging Max Unit Notes 90 – 132/180 – 264 Vac 47 – 63 47 – 440 Hz Hz (C-Grade and E-Grade) (I-Grade) Inrush current: 115 Vac operation: 1 converter 2 converters 3 converters 16 23 39 A A A @ peak line @ peak line @ peak line Inrush current: 230 Vac operation 1 converter 2 converters 3 converters 32 47 78 A A A @ peak line @ peak line @ peak line Ride-through time (full load) 90/180 Vac low line 115/230 Vac nominal line 5 40 ms ms minimum minimum AC fail warning time 5 ms minimum (low line, full load) V V @ 1 mA (1.5 mA max.) Line frequency AC and BUS OK (2 and 3 converter models only) Off state – Vce On state – Vcesat 70 0.4 Module disable (2 and 3 converter models only, optically isolated LED input) Continuous forward current 1 – 30 Forward voltage 1.65 mA V Dielectric withstand Primary to chassis GND Primary to secondary Secondary to chassis GND Vdc Vdc Vdc 2,121 4,242 707 @ 30 mA OUTPUT SPECIFICATIONS E-Grade Parameter Min Set point accuracy C-, I-Grade Typ Max 1% Load/line regulation Min Typ Max Unit 2% 0.5% 1% VNOM 0.5% 1% 0.05% 0.2% 0.2% 0.5% VNOM VNOM LL to HL, 10% to Full Load LL to HL, No Load to full load 0.02 %/°C Over rated temperature Output temperature drift 0.02 0.01 Long term drift 0.02 0.02 Output ripple 2V 5V 10 – 48 V 150 mV 5% 3% Output voltage trimming1 50% Total remote sense compensation 0.5 OVP set point 2 50% %/1 k hours 100 mV 3% 1.5% p-p p-p p-p 20 MHz bandwidth 20 MHz bandwidth 20 MHz bandwidth Volts 0.25 V max. neg. leg 135% VNOM Recycle power Automatic restart 110% 0.5 125% Current limit Short circuit current 110% 60 mV 2% 0.75% 115% Notes 125% 105% 135% 105% 125% INOM 20% 140% 20% 130% INOM FlatPAC™ Rev 1.6 vicorpower.com Page 2 of 6 01/2015 800 927.9474 FlatPAC™ SPECIFICATIONS (CONT.) THERMAL CHARACTERISTICS E-Grade Parameter Min Efficiency Shut down temp. — case C-, I- Grade Typ Max Min 78 – 88% 90 95 Typ Max Units 80 – 90% 105 Operating temp. — case 90 95 Test Conditions @5 V and higher 105 °C Cool and recycle power to restart 85 °C See Thermal Curves Max Units 85 MECHANICAL SPECIFICATIONS E-Grade Parameter Min 3 Weight Typ C-, I- Grade Max Min Typ 22.4 22.4 Ounces (652) (652) (Grams) Test Conditions AGENCY APPROVALS Safety Standards Markings UL1604, UL60950-1 Notes cURus UL / CSA / EN / IEC 60950-1 cTÜVus, CE Mark Low Voltage Directive EMI / EMC Characteristics (Performed on selected samples representative of the U Series FlatPac product family.) 1 2 3 Parameter Notes Conducted emissions, LISN EN 55022 and FCC R&R, Part 15, Subpart B, Class B Radiated emissions, 10 meters EN 55022; 1998 and FCC R&R, Part 15, Subpart B, Class A Electrostatic discharge IEC 61000-4-2: 1995, Level 4; ±8 kV Contact, ± 15 kV Air Discharge RF radiated immunity, E-field IEC 61000-4-3: 1997; 80 MHz to 1.0 GHz, 3 V/M, CW Electrical fast transients/burst EN 61000-4-4: 1995, Level 3; ±2 kV, Surge immunity EN 61000-4-5: 1996 Class 3; ±2 kV Line to Ground, ±1 kV Line to Line RF conducted immunity IEC 61000-4-6: 1996, class 3, 10 Vrms, 150 kHz to 80 MHz Power frequency magnetic field immunity IEC 61000-4-8: 1994, 30 to 300 A/M, 50Hz Voltage dips and interrupts IEC 61000-4-11: 1994 10 V, 12 V and 15 V outputs, trim range ± 10%. Consult factory for wider trim range. Output voltages of 5 V or less incorporate foldback current limiting, outputs greater than 5 V incorporate straight line current limiting. For MU, PU series, multiply value by 2; for NU, QU, RU series, multiply value by 3. FlatPAC™ Rev 1.6 vicorpower.com Page 3 of 6 01/2015 800 927.9474 FlatPAC™ THERMAL CURVES FREE AIR 50 LFM 100 LFM 250 LFM 750 LFM 500 LFM 1000 LFM 400 600 175 350 525 150 300 450 125 100 75 50 250 200 150 100 25 50 0 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Output (Watts) OutputPower Power (Watts) 200 Output Power (Watts) Output Power (Watts) Output Power (Watts) Output Power (Watts) 5 V Output 300 225 150 75 0 0 85 375 5 10 15 20 25 Ambient Temperature (°C) C) Ambient Temperature (Deg. 30 35 40 45 50 55 60 65 70 75 80 85 0 5 10 15 20 25 Ambient Temperature (°C)(Deg. C) Ambient Temperature LU Series 30 35 40 45 50 55 60 65 70 75 80 85 65 70 75 80 85 Ambient Temperature(Deg. (°C) C) Ambient Temperature MU, PU Series NU, QU, RU Series 400 600 175 350 525 150 300 450 125 100 75 250 200 150 50 100 25 50 0 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Output (Watts) OutputPower Power (Watts) 200 Output Power (Watts) Output Power (Watts) Output Power (Watts) Output Power (Watts) 10 to 48 V Output 300 225 150 75 0 0 85 375 5 Ambient Temperature (Deg. Ambient Temperature (°C) C) 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 0 85 5 10 15 20 25 Ambient Temperature (°C)(Deg. C) Ambient Temperature LU Series 30 35 40 45 50 55 60 Ambient Temperature(Deg. (°C) C) Ambient Temperature MU, PU Series NU, QU, RU Series APPLICATION CIRCUITS VLINE > 90 (180)Vac AC Line AC Line Interrupted AC-OK BUS-OK T0 T1 T2 T3 T4 Conditions: Full Load 90 (180)Vac, AC Line MOD-DIS – MOD-DIS + AC-OK – AC-OK + BUS-OK – BUS-OK + Internal Supervisory Circuits (Optocouplers) 2-Up and 3-Up Time Interval T0-T1 T2-T3 T2-T4 T3-T4 Min 0 0 5 5 Typ 0.1 40 – – Max 1.0 – – – Units ms ms ms ms Notes Ride-through time Hold-up time AC fail warning time Power Up and Power Down Sequencing AC Mains Earth Ground L1 1-Up L2/N GND + Vout +O R1 +S Trim –S AC Mains Connections R2 10K Vout RTN –O Resistor Values for Trimming Standard Output Voltages Nom. Output Voltage 5 V R1(kΩ) 0.953 R2(kΩ) 90 12 V 15.8 90 15 V 22.1 90 24 V 41.2 90 Output Trimming FlatPAC™ Rev 1.6 vicorpower.com Page 4 of 6 01/2015 800 927.9474 28 V 48.7 90 48 V Trim Range 90.9 +10%, -10% 90 FlatPAC™ MECHANICAL DRAWINGS Inputs 1 MOD DIS– 2 MOD DIS+ 3 AC OK– 4 AC OK+ 5 BUS OK– 6 BUS OK+ 7 AC IN L1 8 AC IN L2/N 9 CHASSIS GND STANDARD MODELS Input connector, Amp P/N 644488-6; mating connector, MTA-100 IDC Series 1.375 ±0.020 (34,91 ±0,51) Terminals for #16-12 AWG wire Outputs 10 +OUT (#10-32 Stud) 11 +OUT 12 +SENSE (VTRIM*) 13 TRIM (ITRIM*) 14 –SENSE (IMON*) 15 –OUT 16 –OUT (#10-32 Stud) 1.11 ( 28,19) 0.50 (12,57) 9.245 ±0.030 (234,82 ±0,76) CONDUCTION COOLED MODELS “–CC” Output connector, Amp P/N 644486-5; mating connector, MTA-100 IDC Series *On FlatPACs with BatMODs only. LU SERIES MOUNTING HOLE ø 0.15 ±0.01 THRU 4 PLACES 2.156 ±0.010 (54,76 ±0,25) 1.27 (32,26) 10 11 12 13 14 15 16 OUTPUT 1 2.540 ±0.030 (64,52 ±0,76) 7 8 9 0.192 ±0.010 (4,88 ±0,25) 0.18 (4,57) 6.00 (152,4) MU SERIES PU SERIES 3.83 (97,16) 2.281 ±0.010 (57,94 ±0,25) 1.17 (29,72) 10 11 12 13 14 15 16 10 11 12 13 14 15 16 + – 7 8 9 0.199 ±0.010 (5,05 ±0,25) 0.18 (4,57) OUTPUT 2 4.562 ±0.010 (115,87 ±0,25) 4.960 ±0.030 (125,98 ±0,76) + 10 11 12 13 14 15 16 OUTPUT 1 MOUNTING HOLE ø 0.15 ±0.01 THRU 5 PLACES 6.00 (152,4) NU SERIES QU SERIES RU SERIES MOUNTING HOLE ø 0.15 ±0.01 THRU 6 PLACES 10 10 16 16 10 11 12 13 14 15 16 10 11 12 13 14 15 16 2.290 ±0.010 (58,17 ±0,25) 0.190 ±0.010 (4,83 ±0,25) 0.18 (4,57) 6.00 (152,4) FlatPAC™ Rev 1.6 vicorpower.com Page 5 of 6 01/2015 800 927.9474 OUTPUT 1 1.93 (49,02) OUTPUT 1 7 8 9 – 10 11 12 13 14 15 16 10 11 12 13 14 15 16 10 11 12 13 14 15 16 – 4.710 ±0.010 (119,63 ±0,25) 5.48 (139,19) OUTPUT 3 16 + OUTPUT 2 7.000 ±0.010 (177,8 ±0,25) 10 11 12 13 14 15 16 OUTPUT 1 1 2 3 4 5 6 + OUTPUT 2 10 7.380 ±0.030 (187,45 ±0,76) + – FlatPAC™ Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Vicor’s Standard Terms and Conditions All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request. Product Warranty In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER. This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards. Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor's Intellectual Property Department. Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: [email protected] Technical Support: [email protected] FlatPAC™ Rev 1.6 vicorpower.com Page 6 of 6 01/2015 800 927.9474