Half Brick, DC-DC Converters VI-J00 VE-J00 S ® US C C NRTL US 25 to 100 Watts Features • • • • • • • • • • • • Product Highlights The VI-J00 MiniMod family established a new standard in component-level DC-DC converters. This “junior” size complement to the higher power VI-200 family offers up to 100 W of isolated and regulated power in a board mounted package. With thousands of input/output/power combinations, and with a maximum operating temperature rating of 100˚C, the MiniMod provides nearly unlimited flexibiliy for power system designers to meet demanding time to market requirements. Isolated output Up to 50 Watts per cubic inch cURus, cTÜVus CE Marked Up to 90% efficiency Size: 2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7) Remote sense and current limit Logic disable Wide range output adjust ZCS power architecture Low noise FM control RoHS compliant (VE versions) Utilizing Vicor’s “zero-current-switching” forward converter technology, proven by an installed base of over 8 million units, the MiniMod family combines state of the art power density with the efficiency, low noise and reliability required by next generation power systems. Part Numbering Family VI = Non-RoHS VE = RoHS Series J = J00 VI Input 0 = 12 V N = 48 V V = 24 V 4 = 72 V 1 = 24 V T = 110 V 2 = 36 V 6 = 300 V W = 24 V Note: For additional packaging options, please see page 5. — 3 = 48 V 5 = 150 V 7 = 150/300 V J 6 1 — Output C Z = 2V M = 10 V K = 40 V 0 = 5V P = 13.8 V H = 52 V W = 5.5 V N = 18.5 V D = 85 V Y = 3.3 V X = 5.2 V V = 5.8 V T = 6.5 V R = 7.5 V 1 = 12 V 2 = 15 V 3 = 24 V L = 28 V W Grade E = –10 to 100°C ≥ 5V Power <5 4 = 48 V C = –25 to 100°C W = 100 W W = 20 A F = 72 V M = –55 to 100°C Y = 50 W Y = 10 A B = 95 V J = 36 V VI-J00 DC-DC Converters Rev 2.8 vicorpower.com Page 1 of 6 10/2013 800 927.9474 I = – 40 to 100°C X = 75 W Z = 25 W X = 15 A Z=5A VI-J00, VE-J00 Maximum Power Available for VI-Jxx-xx Output Input Vout Designators 5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 3 L 2 N P R M 1 X W V T Voltage Nom. (Range) Low Line 75% Max Power 12 (10-20) n/a 22 0 24 (10-36) n/a n/a V -- Y Y Y 24 (21-32) 18 36 1 W W W W 24 (18-36) n/a n/a W W W W W 36 (21-56) 18 60 2 Y Y Y Y Vin Transient[a] Designators 2 Z 3.3 Y 5 0 X Y X Y X X X X X X X 36 40 J K 48 4 52 H 72 85 F D 95 B X X X X X X X Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y -- -- -- -- W W X X W W W W W W W W W W W W W W W W X X W W W W W W W W W W W W W W Y Y Y Y X X X X X X X X X X X -- -- -- Y 48 (42-60) 36 72 3 W W W W W W X X W W W W W W W W W W W W W W 48 (36-76) n/a n/a N W W X X X X X X W W W W W W W W W W W W W W 72 (55-100) 45 110 4 W W W W W W X X W W W W W W W W W W W W W W 110 (66-160) n/a n/a T W W X X X X X X W W W W W W W W W W W W -- -- 150 (100-200) 85 215 5 W W W W W W X X W W W W W W W W W W W W W W 150 (100-375) n/a n/a 7 Y Y Y Y Y Y Y Y X X X X X X X X X X X -- -- -- 300 (200-400) 170 425 6 W W W W W W X X W W W W W W W W W W W W W W [a] Transient voltage for 1 second. CONVERTER SPECIFICATIONS (typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified) INPUT SPECIFICATIONS Parameter Inrush charge Input reflected ripple current – pp Min VI-J00 E-Grade Typ 60x 10 -6 Max VI-J00 C-, I-, M-Grade Typ 60x 10 10% -6 Max ( ) 20+20 Log ( Vin ) ( ) 30+20 Log Vin Vout Vout Vout No load power dissipation 1.35 2 -6 100 x 10 10% 25+ 20 Log Vin Input ripple rejection Min 1.35 2 VI-J00 DC-DC Converters Rev 2.8 vicorpower.com Page 2 of 6 10/2013 800 927.9474 Units Coulombs Test Conditions Nominal line IIN Nominal line, full load dB 120 Hz, nominal line dB 2400 Hz, nominal line Watts VI-J00, VE-J00 CONVERTER SPECIFICATIONS (cont.) OUTPUT CHARACTERISTICS Parameter Min VI-J00 E-Grade Setpoint accuracy Typ Max 1% Load/line regulation Min VI-J00 C-, I-, M-Grade Typ Max Units 2% 0.5% 1% VNOM 0.5% 0.05% 0.2% VNOM LL to HL, 10% to Full Load 1% 0.2% 0.5% VNOM LL to HL, No Load to 10% 0.02 % / °C Output temperature drift 0.02 0.01 Long term drift 0.02 0.02 Output ripple – pp: 2 V, 3.3 V 5V 10 – 95 V [a] Trim range 50% Total remote sense compensation 0.5 Test Conditions Over rated temperature %/1K hours 200 100 150 mV 20 MHz bandwidth 5% 2% 3% VNOM 20 MHz bandwidth 3% 0.75% 1.5% VNOM 20 MHz bandwidth 110% VNOM 110% 50% 0.5 Volts 0.25 V max. neg. leg Current limit 105% 135% 105% 125% Ifull load Automatic restart Short circuit current 105% 140% 105% 130% Ifull load Automatic restart Units Test Conditions [a] 10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range. 95 V output –50 + 0% trim range. CONTROL PIN SPECIFICATIONS Parameter Min VI-J00 E-Grade Typ Max Min VI-J00 C-, I-, M-Grade Typ Max Gate out impedance 50 50 Ohms Gate in impedance 1000 1000 Ohms Gate in high threshold Gate in low threshold 6 6 0.65 0.65 Gate in low current Volts Volts 6 6 VI-J00 DC-DC Converters Rev 2.8 vicorpower.com Page 3 of 6 10/2013 800 927.9474 mA Use open collector VI-J00, VE-J00 CONVERTER SPECIFICATIONS (cont.) DIELECTRIC WITHSTAND CHARACTERISTICS Parameter Input to output Output to baseplate Input to baseplate Min VI-J00 E-Grade Typ Max Min Max Units Test Conditions Baseplate earthed 3,000 VRMS 500 500 VRMS 1,500 1,500 VRMS Min Efficiency VI-J00 E-Grade Typ Max Min Min Weight 2.9 82.8 Typ 80 – 90% 0.14 0.14 MECHANICAL SPECIFICATIONS Parameter VI-J00 C-, I-, M-Grade 78 – 88% Baseplate to sink VI-J00 E-, C-Grade PRODUCT GRADE TEMPERATURES Parameter Typ 3,000 THERMAL CHARACTERISTICS Parameter VI-J00 C-, I-, M-Grade Typ Max Min 3.2 92 3.6 101.2 3.4 96.3 VI-J00 I-, M-Grade Max Units °C/Watt Typ Max Units 3.8 107 4.1 117.7 Ounces Grams Storage Operating Units E -20 to +105 -10 to + 100 °C C -40 to +105 -25 to + 100 °C I -55 to +105 -40 to + 100 °C M -65 to +105 -55 to + 100 °C VI-J00 DC-DC Converters Rev 2.8 vicorpower.com Page 4 of 6 10/2013 800 927.9474 Test Conditions With Vicor P/N 20267 Test Conditions Notes VI-J00, VE-J00 MECHANICAL DRAWING .49 (12,4) .30±.015 (7,6)±(0,38) V 2.28 (57,9) 1.30 (33,0) .65 (16,5) Standard RoHS 0.080 Dia (2) places Solder plate over copper alloy 0.080 Dia (2) places Matte tin over copper alloy Pin # Function +In 1 4 9 3 8 VI-J00 2.10 (53,4) 7 2 6 1 .15 (3,8) 5 1.40 1.00 (35,6) .70 (25,4) .40 (17,8) (10,2) .35± .015 (8,9)±(0,38) Standard 0.040 (1,0) Dia (7) places Solder plate over copper alloy FULL R .15 (3,8) 2 Gate In 3 Gate Out 4 -In 5 +Out 6 +Sense 7 Trim 8 –Sense 9 –Out RoHS 0.040 Dia (7) places Matte tin over copper alloy 2.40 (61,0) Product ID this surface 1.90 (48,3) .30 (7,6) Min. .22 (5,6) Min. .50 (12,7) 1.75 (44,4) Max. +.030 (0,76) -.000 (0) .01 .12 (3,0) Aluminum Base PACKAGING OPTIONS Flangeless package 2.28"L x 1.80"W x 0.50"H (57,9 x 45,7 x 12,7 mm) Flangeless package with integral heat sink Longitudinal, 0.25"(6.35 mm) fins — add suffix “– F1” Longitudinal, 0.50"(12.7 mm) fins — add suffix “– F2” To order the SlimMod configuration add the suffix “ – S” to the standard module part number. MegaMod Jr. Chassis mount alternatives, one, two, or three outputs: up to 300 W 1 up – 2.58¨ x 2.5¨ x 0.62¨ (65,5 x 63,5 x 15,7 mm) 2 up – 2.58¨ x 4.9¨ x 0.62¨ (65,5 x 124,5 x 15,7 mm) 3 up – 2.58¨ x 7.3¨ x 0.62¨ (65,5 x 185,4 x 15,7 mm) BusMod Qty (2) grounding clips are included with each SlimMod P/N 32187 Transverse, 0.25"(6.35 mm) fins — add suffix “– F3” Transverse, 0.50"(12.7 mm) fins — add suffix “– F4” Available with longitudinal or transverse fins of 0.25"(6.35 mm) or 0.50"(12.7 mm) height. Add the appropriate suffix to the module part number. Qty (4) grounding clips are included with each FinMod F1, F2 P/N 32185 F3, F4 P/N 32186 VI-J00 DC-DC Converters Rev 2.8 vicorpower.com Page 5 of 6 10/2013 800 927.9474 2.28"L x 2.40"W x 1.08"H (57,9 x 61,0 x 27,4 mm) To order the BusMod fully assembled, add suffix “–B1” to the standard module part number. To order the BusMod separately: Half-sized BusMod — P/N 18952 See BusMod Mechanical Drawings for more details. VI-J00, VE-J00 Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Vicor’s Standard Terms and Conditions All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request. Product Warranty In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER. This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards. Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor's Intellectual Property Department. Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: [email protected] Technical Support: [email protected] VI-J00 DC-DC Converters Rev 2.8 vicorpower.com Page 6 of 6 10/2013 800 927.9474