VI-J00 - Vicor

Half Brick, DC-DC Converters
VI-J00
VE-J00
S
®
US
C
C
NRTL
US
25 to 100 Watts
Features
•
•
•
•
•
•
•
•
•
•
•
•
Product Highlights
The VI-J00 MiniMod family established a new standard in component-level DC-DC
converters. This “junior” size complement to the higher power VI-200 family offers up to 100
W of isolated and regulated power in a board mounted package. With thousands of
input/output/power combinations, and with a maximum operating temperature rating of 100˚C,
the MiniMod provides nearly unlimited flexibiliy for power system designers to meet
demanding time to market requirements.
Isolated output
Up to 50 Watts per cubic inch
cURus, cTÜVus
CE Marked
Up to 90% efficiency
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
Remote sense and current limit
Logic disable
Wide range output adjust
ZCS power architecture
Low noise FM control
RoHS compliant (VE versions)
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven by an
installed base of over 8 million units, the MiniMod family combines state of the art power
density with the efficiency, low noise and reliability required by next generation power
systems.
Part Numbering
Family
VI = Non-RoHS
VE = RoHS
Series
J = J00
VI
Input
0 = 12 V N = 48 V
V = 24 V
4 = 72 V
1 = 24 V
T = 110 V
2 = 36 V
6 = 300 V
W = 24 V
Note: For additional
packaging options,
please see page 5.
—
3 = 48 V
5 = 150 V
7 = 150/300 V
J
6
1
—
Output
C
Z = 2V
M = 10 V
K = 40 V
0 = 5V
P = 13.8 V
H = 52 V
W = 5.5 V
N = 18.5 V
D = 85 V
Y = 3.3 V
X = 5.2 V
V = 5.8 V
T = 6.5 V
R = 7.5 V
1 = 12 V
2 = 15 V
3 = 24 V
L = 28 V
W
Grade
E = –10 to 100°C
≥ 5V
Power
<5
4 = 48 V
C = –25 to 100°C
W = 100 W
W = 20 A
F = 72 V
M = –55 to 100°C
Y = 50 W
Y = 10 A
B = 95 V
J = 36 V
VI-J00 DC-DC Converters
Rev 2.8
vicorpower.com
Page 1 of 6
10/2013
800 927.9474
I = – 40 to 100°C
X = 75 W
Z = 25 W
X = 15 A
Z=5A
VI-J00, VE-J00
Maximum Power Available for VI-Jxx-xx
Output
Input
Vout Designators
5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28
3 L
2 N
P
R M 1
X W V T
Voltage
Nom. (Range)
Low Line
75%
Max Power
12 (10-20)
n/a
22
0
24 (10-36)
n/a
n/a
V
--
Y
Y
Y
24 (21-32)
18
36
1
W
W
W
W
24 (18-36)
n/a
n/a
W
W
W
W
W
36 (21-56)
18
60
2
Y
Y
Y
Y
Vin
Transient[a] Designators 2
Z
3.3
Y
5
0
X
Y
X
Y
X
X
X
X
X
X
X
36 40
J K
48
4
52
H
72 85
F D
95
B
X
X
X
X
X
X
X
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
--
--
--
--
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Y
Y
Y
Y
X
X
X
X
X
X
X
X
X
X
X
--
--
--
Y
48 (42-60)
36
72
3
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
48 (36-76)
n/a
n/a
N
W
W
X
X
X
X
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
72 (55-100)
45
110
4
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
110 (66-160)
n/a
n/a
T
W
W
X
X
X
X
X
X
W
W
W
W
W
W
W
W
W
W
W
W
--
--
150 (100-200)
85
215
5
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
150 (100-375)
n/a
n/a
7
Y
Y
Y
Y
Y
Y
Y
Y
X
X
X
X
X
X
X
X
X
X
X
--
--
--
300 (200-400)
170
425
6
W
W
W
W
W
W
X
X
W
W
W
W
W
W
W
W
W
W
W
W
W
W
[a] Transient voltage for 1 second.
CONVERTER SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter
Inrush charge
Input reflected
ripple current – pp
Min
VI-J00 E-Grade
Typ
60x 10
-6
Max
VI-J00 C-, I-, M-Grade
Typ
60x 10
10%
-6
Max
( )
20+20 Log ( Vin )
( )
30+20 Log Vin
Vout
Vout
Vout
No load power dissipation
1.35
2
-6
100 x 10
10%
25+ 20 Log Vin
Input ripple rejection
Min
1.35
2
VI-J00 DC-DC Converters
Rev 2.8
vicorpower.com
Page 2 of 6
10/2013
800 927.9474
Units
Coulombs
Test Conditions
Nominal line
IIN
Nominal line, full load
dB
120 Hz, nominal line
dB
2400 Hz, nominal line
Watts
VI-J00, VE-J00
CONVERTER SPECIFICATIONS (cont.)
OUTPUT CHARACTERISTICS
Parameter
Min
VI-J00 E-Grade
Setpoint accuracy
Typ
Max
1%
Load/line regulation
Min
VI-J00 C-, I-, M-Grade
Typ
Max
Units
2%
0.5%
1%
VNOM
0.5%
0.05%
0.2%
VNOM
LL to HL, 10% to Full Load
1%
0.2%
0.5%
VNOM
LL to HL, No Load to 10%
0.02
% / °C
Output temperature drift
0.02
0.01
Long term drift
0.02
0.02
Output ripple – pp:
2 V, 3.3 V
5V
10 – 95 V
[a]
Trim range
50%
Total remote
sense compensation
0.5
Test Conditions
Over rated temperature
%/1K hours
200
100
150
mV
20 MHz bandwidth
5%
2%
3%
VNOM
20 MHz bandwidth
3%
0.75%
1.5%
VNOM
20 MHz bandwidth
110%
VNOM
110%
50%
0.5
Volts
0.25 V max. neg. leg
Current limit
105%
135%
105%
125%
Ifull load
Automatic restart
Short circuit current
105%
140%
105%
130%
Ifull load
Automatic restart
Units
Test Conditions
[a] 10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range.
95 V output –50 + 0% trim range.
CONTROL PIN SPECIFICATIONS
Parameter
Min
VI-J00 E-Grade
Typ
Max
Min
VI-J00 C-, I-, M-Grade
Typ
Max
Gate out impedance
50
50
Ohms
Gate in impedance
1000
1000
Ohms
Gate in high threshold
Gate in low threshold
6
6
0.65
0.65
Gate in low current
Volts
Volts
6
6
VI-J00 DC-DC Converters
Rev 2.8
vicorpower.com
Page 3 of 6
10/2013
800 927.9474
mA
Use open collector
VI-J00, VE-J00
CONVERTER SPECIFICATIONS (cont.)
DIELECTRIC WITHSTAND CHARACTERISTICS
Parameter
Input to output
Output to baseplate
Input to baseplate
Min
VI-J00 E-Grade
Typ
Max
Min
Max
Units
Test Conditions
Baseplate earthed
3,000
VRMS
500
500
VRMS
1,500
1,500
VRMS
Min
Efficiency
VI-J00 E-Grade
Typ
Max
Min
Min
Weight
2.9
82.8
Typ
80 – 90%
0.14
0.14
MECHANICAL SPECIFICATIONS
Parameter
VI-J00 C-, I-, M-Grade
78 – 88%
Baseplate to sink
VI-J00 E-, C-Grade
PRODUCT GRADE TEMPERATURES
Parameter
Typ
3,000
THERMAL CHARACTERISTICS
Parameter
VI-J00 C-, I-, M-Grade
Typ
Max
Min
3.2
92
3.6
101.2
3.4
96.3
VI-J00 I-, M-Grade
Max
Units
°C/Watt
Typ
Max
Units
3.8
107
4.1
117.7
Ounces
Grams
Storage
Operating
Units
E
-20 to +105
-10 to + 100
°C
C
-40 to +105
-25 to + 100
°C
I
-55 to +105
-40 to + 100
°C
M
-65 to +105
-55 to + 100
°C
VI-J00 DC-DC Converters
Rev 2.8
vicorpower.com
Page 4 of 6
10/2013
800 927.9474
Test Conditions
With Vicor P/N 20267
Test Conditions
Notes
VI-J00, VE-J00
MECHANICAL DRAWING
.49
(12,4)
.30±.015
(7,6)±(0,38)
V
2.28
(57,9)
1.30
(33,0)
.65
(16,5)
Standard
RoHS
0.080 Dia (2) places
Solder plate
over copper alloy
0.080 Dia (2) places
Matte tin over copper
alloy
Pin #
Function
+In
1
4
9
3
8
VI-J00
2.10
(53,4)
7
2
6
1
.15
(3,8)
5
1.40
1.00 (35,6)
.70 (25,4)
.40 (17,8)
(10,2)
.35± .015
(8,9)±(0,38)
Standard
0.040 (1,0) Dia (7) places
Solder plate
over copper alloy
FULL R
.15
(3,8)
2
Gate In
3
Gate Out
4
-In
5
+Out
6
+Sense
7
Trim
8
–Sense
9
–Out
RoHS
0.040 Dia (7) places
Matte tin over copper
alloy
2.40
(61,0)
Product ID
this surface
1.90
(48,3)
.30
(7,6) Min.
.22
(5,6) Min.
.50
(12,7)
1.75
(44,4) Max.
+.030 (0,76)
-.000 (0)
.01
.12
(3,0)
Aluminum Base
PACKAGING OPTIONS
Flangeless package
2.28"L x 1.80"W x 0.50"H
(57,9 x 45,7 x 12,7 mm)
Flangeless package
with integral heat sink
Longitudinal, 0.25"(6.35 mm) fins — add suffix “– F1”
Longitudinal, 0.50"(12.7 mm) fins — add suffix “– F2”
To order the SlimMod configuration add the suffix “ – S” to
the standard module part number.
MegaMod Jr.
Chassis mount alternatives, one, two,
or three outputs: up to 300 W
1 up – 2.58¨ x 2.5¨ x 0.62¨ (65,5 x 63,5 x 15,7 mm)
2 up – 2.58¨ x 4.9¨ x 0.62¨ (65,5 x 124,5 x 15,7 mm)
3 up – 2.58¨ x 7.3¨ x 0.62¨ (65,5 x 185,4 x 15,7 mm)
BusMod
Qty (2) grounding clips are included with each SlimMod
P/N 32187
Transverse, 0.25"(6.35 mm) fins — add suffix “– F3”
Transverse, 0.50"(12.7 mm) fins — add suffix “– F4”
Available with longitudinal or transverse fins of 0.25"(6.35
mm) or 0.50"(12.7 mm) height. Add the appropriate
suffix to the module part number.
Qty (4) grounding clips are included with each FinMod
F1, F2 P/N 32185
F3, F4 P/N 32186
VI-J00 DC-DC Converters
Rev 2.8
vicorpower.com
Page 5 of 6
10/2013
800 927.9474
2.28"L x 2.40"W x 1.08"H
(57,9 x 61,0 x 27,4 mm)
To order the BusMod fully assembled, add suffix “–B1” to
the standard module part number.
To order the BusMod separately:
Half-sized BusMod — P/N 18952
See BusMod Mechanical Drawings for more details.
VI-J00, VE-J00
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked
and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements,
testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be
liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and
assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing
and operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to
the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause
the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor
products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
VI-J00 DC-DC Converters
Rev 2.8
vicorpower.com
Page 6 of 6
10/2013
800 927.9474