Data Sheet MIL-COTS AC-DC Power Supply 1200 W Power Factor Corrected AC-DC Power Supply Features • AC input: 85 – 264 V • Wide input frequency range: 47 – 440 Hz • Output power: Up to 1200 W • Output voltage: Up to 108 Vdc • Input transient protection per: – MIL-STD-704E/F – DO-160E/F • EMI filtering per MIL-STD-461E/F • Multiple outputs • Power factor corrected • Low profile Product Options • Rugged construction Product Highlights The MIL-COTS AC-DC power supply from Granite Power Technologies is a new class of customizable modular power systems designed for the most demanding applications. Utilizing Vicor’s proven Maxi, Mini, and Micro DC-DC converters along with a robust PFC front end and EMI filter, the MIL-COTS AC-DC power supply can accept a wide 85-264 Vac input range, frequencies from 47 to 440 Hz and deliver up to 1200 W of output power. The MILCOTS AC-DC power supply is compliant to MIL-STD-704E/F and DO-160E/F for input transients and the conducted emissions and susceptibility portions of MIL-STD-461E/F. Also, the MIL-COTS AC-DC power supply has a very low profile and robust construction, compliant to many environments in MIL-STD-810, including shock and vibration. The MIL-COTS AC-DC power supply is a customizable power supply, allowing customers to easily configure parameters specific to their requirements, such as: • • • • • • Total power Number of outputs Heatsinks Packaging (including unique geometries) Holdup capacitance Remote control options For additional information on the MIL-COTS AC-DC power supply or to configure solutions tailored to your needs, please contact Granite Power Technologies. The MIL-COTS AC-DC power supply provides customers with a highly reliable, easily customizable, and low risk solution suitable for defense and aerospace environments. Granite Power Technologies, a subsidiary of the Vicor Corporation, specializes in the design, development, and manufacture of rapid response custom switching power supplies and power systems for the defense industry. Granite Power Technologies Tel: 603-623-3222 Vicor Corporation Tel: 800-735-6200, 978-470-2900 Rev. 1.0 Set your site on Vicor at vicorpower.com Page 1 of 4 SPECIFICATIONS INPUT SPECIFICATIONS Parameters Values Min Typ Notes Max Unit Operating input voltage 85 264 Vac AC line frequency 47 440 Hz 8 % Power factor Universal input 0.9 Total harmonic distortion 5 OUTPUT SPECIFICATIONS Parameters Values Min Notes Typ Max Unit Set point accuracy 0.5% 1.0% VNOM Line regulation 0.02% 0.2% VNOM 85 – 264 Vac Load regulation 0.2% 0.5% VNOM 85 – 264 Vac Output temperature drift 0.01 0.02 %/°C Over rated temperature Long term drift 0.02 %/1 k hours Output ripple 3.3 V 120 150 mVp-p 20 MHz bandwidth 5V 120 150 mVp-p 20 MHz bandwidth 12 – 54 V 2% 3% p-p 20 MHz bandwidth Ouput voltage trimming 10% 110% Total remote sense compensation 120% See vicorpower.com for trim calculator 0.5 Volts 0.25 V max. neg. leg 125% VNOM Recycle power Automatic restart OVP set point 115% Current limit 102% 135% INOM Short circuit current 70% 135% INOM EMI SPECIFICATIONS Parameter MIL-STD-461E/F Conducted emissions Conducted Susceptibility CE101, CE102 CS101, CS106 (461F), CS114, CS115, CS116 ENVIRONMENTAL – SYSTEM Parameters Notes Min Typ Max Unit Operating Temperature -55 100 °C M-grade, H-grade available Storage Temperature -65 125 °C M-grade, H-grade available Granite Power Technologies Tel: 603-623-3222 Vicor Corporation Tel: 800-735-6200, 978-470-2900 Rev. 1.0 Set your site on Vicor at vicorpower.com Page 2 of 4 SPECIFICATIONS ENVIRONMENTAL QUALIFICATION Altitude MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational. Explosive Atmosphere MIL-STD-810F, Method 511.4, Procedure I, Operational. Vibration MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17 with overall level of 7.7 G rms for 1 hour per axis. Shock MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft. MIL-STD-202F, Method 213B, 60 g, 9ms half sine. MIL-STD-202F, Method 213B, 75 g, 11ms Saw Tooth Shock. Acceleration MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions. Humidity MIL-STD-810F, Method 507.4. Solder Test MIL-STD-202G, Method 208H, 8 hour aging. MIL-COTS PFC FrontEnd (GP-MPFC1M21) Input Characteristics • Input voltage range: 85 – 264 Vac • Input frequency range: 47 – 440 Hz • Power Factor: 0.95 typ. • Total Harmonic Distortion: 10% max. Output Characteristics • Output power: 1400 W (Derating below 100 Vac input) • Output voltage: 384 Vdc nom. • Efficiency: 95% typ. General Specifications • Operating temperature: -55 to 100°C • Storage temperature: -65 to 125°C • Dimensions: 6.4 x 2.7 x 0.5 in. • Weight: 9.6 oz. Product Description The GP-MPFC1H21 MIL-COTS AC-DC front end is a high power, PFC front end designed for MIL-COTS AC-DC applications. The GP-MPFC1H21 accepts a wide input voltage and frequency range and is compliant to MIL-STD-704E/F and DO-160E/F for input transients and is designed to withstand harsh environments typical of military and aerospace applications. Granite Power Technologies Tel: 603-623-3222 Vicor Corporation Tel: 800-735-6200, 978-470-2900 MIL-COTS PFC Front-End EMI Filter (GP-MEMIDM21) Input Characteristics • Input voltage range: 85 – 264 Vac • Input frequency range: 47 – 440 Hz Output Characteristics • Output power: 1500 W • Efficiency: 99% General Specifications • Operating temperature: -55 to 100°C • Storage temperature: -65 to 125°C • Dimensions: 4.8 x 2.7 x 0.5 in. • Weight: TBD Product Description The GP-MEMIDH21 is an EMI filter that when used with the M-PFC1200-H, will provide MIL-STD-461E/F (CE and CS) compliance for both 50/60 and 400 Hz applications. The GP-MEMIDH21 is constructed in a robust brick package and is designed to withstand harsh environments typical of military and aerospace applications. Rev. 1.0 Set your site on Vicor at vicorpower.com Page 3 of 4 Warranty Granite Power Technologies products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Granite Power Technologies shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only. EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, GRANITE POWER TECHNOLOGIES MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Granite Power Technologies will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the buyer must contact Granite Power Technologies to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Granite Power Technologies will pay all reshipment charges if the product was defective within the terms of this warranty. Information published by Granite Power Technologies has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Granite Power Technologies reserves the right to make changes to any products without further notice to improve reliability, function, or design. Granite Power Technologies does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Granite Power Technologies general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Granite Power Technologies Terms and Conditions of Sale, the user of Granite Power Technologies components in life support applications assumes all risks of such use and indemnifies Granite Power Technologies against all damages Information furnished by Granite Power Technologies Power Systems is believed to be accurate and reliable. However, no responsibility is assumed by Granite Power Technologies Power for its use. Granite Power Technologies Power’s power supplies are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Granite Power Technologies Power’s Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. Intellectual Property Notice Granite Power Technologies and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. Interested parties should contact Granite Power Technologies Intellectual Property Department. 25 Frontage Road • Andover, MA 01810-5413 Tel: 800-496-5570 Customer Service: [email protected] Technical Support: [email protected] Granite Power Technologies Tel: 603-623-3222 Vicor Corporation Tel: 800-735-6200, 978-470-2900 Rev. 1.0 Set your site on Vicor at vicorpower.com 04/11 Page 4 of 4