MIL-COTS AC-DC Power Supply

Data Sheet
MIL-COTS AC-DC Power Supply
1200 W Power Factor Corrected
AC-DC Power Supply
Features
• AC input: 85 – 264 V
• Wide input frequency range:
47 – 440 Hz
• Output power: Up to 1200 W
• Output voltage: Up to 108 Vdc
• Input transient protection per:
– MIL-STD-704E/F
– DO-160E/F
• EMI filtering per MIL-STD-461E/F
• Multiple outputs
• Power factor corrected
• Low profile
Product Options
• Rugged construction
Product Highlights
The MIL-COTS AC-DC power supply from
Granite Power Technologies is a new class
of customizable modular power systems
designed for the most demanding
applications. Utilizing Vicor’s proven Maxi,
Mini, and Micro DC-DC converters along
with a robust PFC front end and EMI filter,
the MIL-COTS AC-DC power supply can
accept a wide 85-264 Vac input range,
frequencies from 47 to 440 Hz and deliver
up to 1200 W of output power. The MILCOTS AC-DC power supply is compliant to
MIL-STD-704E/F and DO-160E/F for input
transients and the conducted emissions and
susceptibility portions of MIL-STD-461E/F.
Also, the MIL-COTS AC-DC power supply
has a very low profile and robust construction, compliant to many environments in
MIL-STD-810, including shock and
vibration.
The MIL-COTS AC-DC power supply is a customizable power supply,
allowing customers to easily configure parameters specific to
their requirements, such as:
•
•
•
•
•
•
Total power
Number of outputs
Heatsinks
Packaging (including unique geometries)
Holdup capacitance
Remote control options
For additional information on the MIL-COTS AC-DC power supply
or to configure solutions tailored to your needs, please contact
Granite Power Technologies.
The MIL-COTS AC-DC power supply
provides customers with a highly reliable,
easily customizable, and low risk solution
suitable for defense and aerospace
environments.
Granite Power Technologies, a subsidiary
of the Vicor Corporation, specializes in the
design, development, and manufacture of
rapid response custom switching power
supplies and power systems for the
defense industry.
Granite Power Technologies Tel: 603-623-3222
Vicor Corporation Tel: 800-735-6200, 978-470-2900
Rev. 1.0
Set your site on Vicor at vicorpower.com
Page 1 of 4
SPECIFICATIONS
INPUT SPECIFICATIONS
Parameters
Values
Min
Typ
Notes
Max
Unit
Operating input voltage
85
264
Vac
AC line frequency
47
440
Hz
8
%
Power factor
Universal input
0.9
Total harmonic distortion
5
OUTPUT SPECIFICATIONS
Parameters
Values
Min
Notes
Typ
Max
Unit
Set point accuracy
0.5%
1.0%
VNOM
Line regulation
0.02%
0.2%
VNOM
85 – 264 Vac
Load regulation
0.2%
0.5%
VNOM
85 – 264 Vac
Output temperature drift
0.01
0.02
%/°C
Over rated temperature
Long term drift
0.02
%/1 k hours
Output ripple
3.3 V
120
150
mVp-p
20 MHz bandwidth
5V
120
150
mVp-p
20 MHz bandwidth
12 – 54 V
2%
3%
p-p
20 MHz bandwidth
Ouput voltage trimming
10%
110%
Total remote sense compensation
120%
See vicorpower.com for trim calculator
0.5
Volts
0.25 V max. neg. leg
125%
VNOM
Recycle power
Automatic restart
OVP set point
115%
Current limit
102%
135%
INOM
Short circuit current
70%
135%
INOM
EMI SPECIFICATIONS
Parameter
MIL-STD-461E/F
Conducted emissions
Conducted Susceptibility
CE101, CE102
CS101, CS106 (461F), CS114, CS115, CS116
ENVIRONMENTAL – SYSTEM
Parameters
Notes
Min
Typ
Max
Unit
Operating Temperature
-55
100
°C
M-grade, H-grade available
Storage Temperature
-65
125
°C
M-grade, H-grade available
Granite Power Technologies Tel: 603-623-3222
Vicor Corporation Tel: 800-735-6200, 978-470-2900
Rev. 1.0
Set your site on Vicor at vicorpower.com
Page 2 of 4
SPECIFICATIONS
ENVIRONMENTAL QUALIFICATION
Altitude
MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J
Main Rotor with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity
Curve per Figure 514.5C-17 with overall level of 7.7 G rms for 1 hour per axis.
Shock
MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis,
1,3,5 ft. MIL-STD-202F, Method 213B, 60 g, 9ms half sine. MIL-STD-202F, Method 213B, 75 g, 11ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions.
Humidity
MIL-STD-810F, Method 507.4.
Solder Test
MIL-STD-202G, Method 208H, 8 hour aging.
MIL-COTS PFC FrontEnd (GP-MPFC1M21)
Input Characteristics
• Input voltage range: 85 – 264 Vac
• Input frequency range: 47 – 440 Hz
• Power Factor: 0.95 typ.
• Total Harmonic Distortion: 10% max.
Output Characteristics
• Output power: 1400 W (Derating below 100 Vac input)
• Output voltage: 384 Vdc nom.
• Efficiency: 95% typ.
General Specifications
• Operating temperature: -55 to 100°C
• Storage temperature: -65 to 125°C
• Dimensions: 6.4 x 2.7 x 0.5 in.
• Weight: 9.6 oz.
Product Description
The GP-MPFC1H21 MIL-COTS AC-DC front end is a high
power, PFC front end designed for MIL-COTS
AC-DC applications. The GP-MPFC1H21 accepts a wide
input voltage and frequency range and is compliant to
MIL-STD-704E/F and DO-160E/F for input transients and
is designed to withstand harsh environments typical of
military and aerospace applications.
Granite Power Technologies Tel: 603-623-3222
Vicor Corporation Tel: 800-735-6200, 978-470-2900
MIL-COTS PFC Front-End EMI Filter
(GP-MEMIDM21)
Input Characteristics
• Input voltage range: 85 – 264 Vac
• Input frequency range: 47 – 440 Hz
Output Characteristics
• Output power: 1500 W
• Efficiency: 99%
General Specifications
• Operating temperature: -55 to 100°C
• Storage temperature: -65 to 125°C
• Dimensions: 4.8 x 2.7 x 0.5 in.
• Weight: TBD
Product Description
The GP-MEMIDH21 is an EMI filter that when used with
the M-PFC1200-H, will provide MIL-STD-461E/F (CE and
CS) compliance for both 50/60 and 400 Hz applications.
The GP-MEMIDH21 is constructed in a robust brick
package and is designed to withstand harsh environments
typical of military and aerospace applications.
Rev. 1.0
Set your site on Vicor at vicorpower.com
Page 3 of 4
Warranty
Granite Power Technologies products are guaranteed for two years from date of shipment against defects in material or workmanship
when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or
maintenance. Granite Power Technologies shall not be liable for collateral or consequential damage. This warranty is extended to the
original purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, GRANITE POWER TECHNOLOGIES MAKES NO WARRANTY,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE.
Granite Power Technologies will repair or replace defective products in accordance with its own best judgement. For service under
this warranty, the buyer must contact Granite Power Technologies to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred
in returning the product to the factory. Granite Power Technologies will pay all reshipment charges if the product was defective within
the terms of this warranty.
Information published by Granite Power Technologies has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Granite Power Technologies reserves the right to make changes to any products without further
notice to improve reliability, function, or design. Granite Power Technologies does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Granite Power
Technologies general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Granite Power Technologies Terms and Conditions of Sale, the user of Granite Power
Technologies components in life support applications assumes all risks of such use and indemnifies Granite Power Technologies
against all damages
Information furnished by Granite Power Technologies Power Systems is believed to be accurate and reliable. However, no responsibility is assumed by Granite Power Technologies Power for its use. Granite Power Technologies Power’s power supplies are not designed
to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are
subject to Granite Power Technologies Power’s Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Granite Power Technologies and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending
patent applications) relating to the products described in this data sheet. Interested parties should contact Granite Power Technologies
Intellectual Property Department.
25 Frontage Road • Andover, MA 01810-5413
Tel: 800-496-5570
Customer Service: [email protected]
Technical Support: [email protected]
Granite Power Technologies Tel: 603-623-3222
Vicor Corporation Tel: 800-735-6200, 978-470-2900
Rev. 1.0
Set your site on Vicor at vicorpower.com
04/11
Page 4 of 4