VME450 Power Supply Data Sheet

Data Sheet
AEGIS
VME450-01
Power Systems, Inc.
28 Vdc VME Power Supply
4 Outputs, 550 W
Features
• 28 Vdc per MIL-STD-704F
• 4 Output voltages, 550 W
• MIL-STD-810F environment
• MIL-STD-461E EMI
• Utilizes Vicor’s cutting edge V•I Chips
for industry leading power density
• Single slot VME power supply
Product Highlights
The single-slot VME450 power supply —
filtered 28 Vdc, four output (3.3, 5, ±12 V),
550 W — is a military COTS solution that
is compliant to the vibration requirements
of MIL-STD-810F and EMI per MIL-STD461E. When compared to VME power
supplies using conventional technology,
the one-slot VME450 provides users with
higher efficiency (85%), lower weight (2.4
pounds), and higher power (up to 550 W).
Built with Vicor V•I Chips, it uses two
M-FIAM modules, six PRMs and six VTMs.
Maximum Ratings
Parameter
Vin max range
Temperature
Rating
Unit
18 to 36
Vdc
–40 to +85
˚C
Combined output power
550
W
Input power
650
W
Max +5 V power
224
W
Max +3.3 V power
224
W
Max +12 V power
100
W
Max –12 V power
100
W
Aegis Power Systems, a subsidiary of the
Vicor Corporation, specializes in the
design, development, and manufacture of
rapid response custom switching power
supplies and power systems for the
defense industry.
Notes
Use output derating Fig. 1
@ 550 Wout
Output Power (W)
VME450 Power Derating
600
550
500
450
400
350
300
250
200
150
100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 60 65 70 75 80 85
Baseplate Temperature (˚C)
at wedgelocks
Fig. 1
Aegis Power Systems Inc. Tel: 828-837-4029
Vicor Corporation Tel: 800-735-6200, 978-470-2900
Rev. 1.4
Set your site on Vicor at vicorpower.com
Page 1 of 4
SPECIFICATIONS
(typical at 25°C, nominal line and 100% load, unless otherwise specified)
SPECIFICATIONS
Parameters
Notes
DC input voltage
Meets MIL-STD-704F normal range
22 Vdc to 29 Vdc, 28 Vdc nominal
50 Vdc 12.5 msec transient, shut down for longer automatic restart
Shuts down for abnormal range automatic restart
DC input line current
24.1 A max. @ 22 Vdc; 18.5 A typical @ 28 Vdc input (450 Wout)
29.4 A max. @ 22 Vdc; 22.6 A typical @ 28 Vdc input (550 Wout)
Input power
529 W max @ 450 Wout, 650 W max @ 550 Wout
Output power
450 to 550 W max. all outputs combined (see Fig. 1)
Output voltages
See table 1
Efficiency
85% min., 87% typical
Start up time
500 ms. max.
Voltage set point,
Line, Load regulation
+/– 2% Vout nominal (for any combination)
Temperature regulation
+/– 0.01% / °C
Output ripple
50 mV pk-pk Max. (20 MHz BW) all except; +/-12 Vdc 100 mV pk-pk Max. (20 MHz BW)
Current Limit
Short circuit protected, automatic recovery
Temperature
–40˚C to +75˚C Operating baseplate wedgelocks 550 W
–40˚C to +85˚C Operating baseplate wedgelocks 450 W
–55˚C to +100˚C Non-operating
Size / Weight
6U x 4hp x 160 mm (see mech drawing) / 2.4 lb. typical
Connector
1ea Positronics PCIH47M400A1 or equivalent (see drawing for pin assignments)
Vibration
MIL-STD-810F, Method 514.5, Procedure I
Shock
MIL-STD-810F, Method 516.5, Procedure I
Humidity
0 – 95% non-condensing
EMI
MIL-STD-461E, CE102, CS101
TABLE 1
VME450-xx
V1
V2
V3
V4
01
+5 Vdc
40 A
200 W
+3.3 Vdc
55 A
182 W
+12 Vdc
7.1 A
85 W
–12 Vdc
7.1 A
85 W
Output voltage variants are possible–contact your Vicor Sales Representative for details.
Aegis Power Systems Inc. Tel: 828-837-4029
Vicor Corporation Tel: 800-735-6200, 978-470-2900
Rev. 1.4
Set your site on Vicor at vicorpower.com
Page 2 of 4
SPECIFICATIONS
MECHANICAL DRAWING
Pins 43, 44
Pin 45
Pin 46
Pin 47
CR5 CR4
R10
R4
R22
R16
6.571
6.299
C16
C8
R89
R90
U1
R29
R30
Q1
C7
R28
R7
R8
R9
C3
C4
R11
R12
C4
R25
R26
C14
R19
R20
R21
C5
R3
R2
R14
R15
C9
R1
R13
C11
C13
5.350
U3
R27
R23
R24
C12
R5
C10
R6
C6
R17
R18
C2
U2
C29
C53
C30
C54
C31
C55
C32
C56
C33
C57
C34
C58
C35
C59
C36
C60
C37
C61
C38
C62
C39
C63
C40
C64
C41
C65
C42
C66
C43
C67
C44
C68
C45
C69
C46
C70
C47
C71
C48
C72
C49
C73
C50
C74
C51
C75
C52
C76
R65
R64
R36
R42
R63
R35
R41
R76
R66
R61
R60
R62
L15
L13
R58
R57
R56
R34
R40
C20
C28
A2
C78
C22
C21
R33
C27
R59
R55
C17
R39
R32
C26
R75
R74
R52
R53
R51
C16
A1
C25
C18
NC
Inhibit (Connect pin to
negative input to disable)
NC
Power OK,
(Open collector = Fail)
NC
Chassis Ground
Positive
Negative Input
C24
R47
R38
R31
R37
R43
R54
L9
R49
R50
R48
C16
R73
R44
R46
R45
NC
NC
NC
L11
L17
NC
C77
Pins 40, 41
Pin 42
+5 Vdc
+5 V RTN (Common)
+3.3 V RTN (Common)
+3.3 Vdc
+12 Vdc
+12 V RTN (Common)
-12 Vdc
-12 V RTN (Common)
NC
Signal RTN (Common)
L7
Pins 1, 2, 3, 4
Pins 5, 6, 7, 8
Pins 9, 10, 11, 12
Pins 13, 14, 15, 16
Pin 17
Pin 18
Pin 19
Pin 20
Pin 21
Pin 22
Pins 23, 24, 25, 26,
27, 28, 29
Pin 30
Pin 31
Pin 32
Pins 33, 34, 35, 36,
37, 38
Pin 39
4.594
Connector Positronic P/N PCIH47M400A1, OR EQ.
0.000
Table 2
0.276
0.670
Pin 47
0.595
Max Height
Pin 21
Pin 1
0.000
Recessed Removal Handle
0.000
0.595
0.510
0.124
0.670 Max Height
0.061
0.000
0.000 0.098
Aegis Power Systems Inc. Tel: 828-837-4029
Vicor Corporation Tel: 800-735-6200, 978-470-2900
9.089
Rev. 1.4
Set your site on Vicor at vicorpower.com
9.187
Page 3 of 4
Warranty
Aegis products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use
and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance.
Aegis shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, AEGIS MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING,
BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Aegis will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the buyer
must contact Aegis to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without
prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory.
Aegis will pay all reshipment charges if the product was defective within the terms of this warranty.
Information published by Aegis has been carefully checked and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Aegis reserves the right to make changes to any products without further notice to improve reliability, function, or design.
Aegis does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license
under its patent rights nor the rights of others. Aegis general policy does not recommend the use of its components in life support
applications wherein a failure or malfunction may directly threaten life or injury. Per Aegis Terms and Conditions of Sale, the user
of Aegis components in life support applications assumes all risks of such use and indemnifies Aegis against all damages.
Information furnished by Aegis Power Systems is believed to be accurate and reliable. However, no responsibility is assumed by Aegis
Power for its use. Aegis Power’s power supplies are not designed to be used in applications, such as life support systems, wherein a failure
or malfunction could result in injury or death. All sales are subject to Aegis Power’s Terms and Conditions of Sale, which are available
upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Aegis and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications)
relating to the products described in this data sheet. Interested parties should contact Aegis's Intellectual Property Department.
Aegis Power Systems, Inc.
P.O. Box 429, 805 Greenlawn road
Murphy, NC 28906-0429
email
[email protected]
Vicor Corporation
25 Frontage Road
Andover, MA 01810
email
Customer Service: [email protected]
Technical Support: apps@vicorpower
AEGIS
Power Systems, Inc.
Aegis Power Systems Inc. Tel: 828-837-4029
Vicor Corporation Tel: 800-735-6200, 978-470-2900
Rev. 1.4
Set your site on Vicor at vicorpower.com
11/08