MI-AIM Datasheet

Data Sheet
MI-AIM
AC Input Front End Module
Features
• Inputs: 115 Vac 60/400 Hz
• Output power: 250 W
• MIL-STD-704A input transient
protection
• MIL-STD-461D/E EMI compliant*
• MIL-STD-810, MIL-STD-202
environments
• Compatible with MI-x7x family
modules
• Efficiency: 95%
• Operating temperature to 100 ˚C
• Size: 2.28" x 2.4" x 0.5"
Actual size:
2.28 x 2.4 x 0.5 in
57,9 x 61,0 x 12,7 mm
(57,9 x 61,0 x 12,7 mm)
Product Highlights
The AC input module interfaces directly with
AC mains to provide line rectification, EMI
filtering, transient protection, and inrush
limiting. These front-end modules accept 115
Vac and provide 250 W of output power for
any of Vicor's MI-x7x family of standard and
junior size modules.
The MI-AIM meets CE102 conducted emissions
requirements of MIL-STD-461D/E* and the
transient and spike requirements of
MIL-STD-704A.
Fully encapsulated in Vicor’s industry
standard package, the MI-AIM meets
MIL-STD-810 Environmental testing
requirements for humidity, fungus, salt- fog,
explosive atmosphere, acceleration, vibration
and shock.
Packaging Options
Input Characteristics
Parameter
Min
AC line input
Typ
Input transient
MIL-STD-704A/
MIL-HDBK-704-1-8
Unit
85
115
140
Vac
47
60/400
440
Hz
40
A, peak
Inrush current
Conducted EMI*
Max
Notes
Operates over entire range
125 Vac
CE102 per MIL-STD-461 D/E
100 – 125 Vac; 60 Hz
TABLE SAC109-II normal
voltage transients
Performance Criteria: Nominal
output voltage may deviate but
self recovers
TABLE SAC302-II abnormal
voltage transients
Performance Criteria: Nominal
output voltage may deviate but
self recovers
*
EMI performance is subject to a wide variety of external influences such as PCB
construction, circuit layout etc. As such, external components in addition to those listed
herein may be required in specific instances to gain full compliance to the standards
specified.
Output Characteristics
Standard: Slotted baseplate
Parameter
SlimMod: Flangeless baseplate, option suffix: - S
Example: MI - AIM - M1 - S
FinMod: Finned heat sink, option suffix:
- F1, - F2, -F3 or -F4
Examples:
MI - AIM - M1 -F1, 0.25" fins, longitudinal
MI - AIM - M1 -F2, 0.50" fins, longitudinal
MI - AIM - M1 -F3, 0.25" fins, transverse
MI - AIM - M1 -F4, 0.50" fins, transverse
Min
Typ
Max
Output power
250
Hold-up time
Application specific
Efficiency
Unit
Notes
W
100 °C
A function of external
capacitance and power
95%
115 Vac; 60/400 Hz
Model Selection Chart
Model Number
MI-AIM-M1
MI-AIM-I1
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Compatible MI-Series
Converter
Operating Temp (°C)
Storage Temp (°C)
MI-27x /MI-J7x
MI-27x /MI-J7x
M–grade
I–grade
–55 to +85 /+100
–40 to +85 /+100
–65 to +100 /+125
–55 to +100/+125
MI-AIM, AC Input Front End Module
Set your site on VICOR at www.vicorpower.com
Rev. 1.4
Page 1 of 5
SPECIFICATIONS
(typical at TBP = 25 °C, nominal line and 75% load, unless otherwise specified)
SAFETY SPECIFICATIONS
Parameter
Min
Typ
Dielectric withstand
Input to output
Input/output to baseplate
Max
Unit
Notes
None
Provided by DC-DC converter
1,500
Vrms
ENVIRONMENTAL — MIL-STD-810D
Parameter
Unit
Notes
Altitude - Method 500.2
70,000
feet
Procedure II
Humidity - Method 507.2
88/ 240
%/ hours
9.0
g
Acceleration - Method 513.3
Min
Typ
Max
Procedure I, cycle 1
Procedure II
Vibration - Method 514.3
20
g
Procedure I, category 6
Shock - Method 516.3
40
g
Procedure I
RELIABILITY — MIL-HDBK-217F (MI-AIM-M1)
Parameter
Min
Typ
Max
Unit
25 °C Ground Benign: G.B.
5,545
1,000 hrs
50 °C Naval Sheltered: N.S.
998
1,000 hrs
65 °C Airborne Inhabited Cargo: A.I.C.
782
1,000 hrs
Notes
GENERAL SPECIFICATIONS
Parameter
Size
Weight
Min
Typ
Max
Unit
2.28 x 2.4 x 0.5
(57,9 x 61,0 x 12,7)
in
(mm)
3.0
(85)
Ounces
(Grams)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Notes
MI-AIM, AC Input Front End Module
Set your site on VICOR at www.vicorpower.com
Rev. 1.4
Page 2 of 5
SPECIFICATIONS (cont.)
PRODUCT GRADE SPECIFICATIONS
Parameter
I-Grade
M-Grade
Storage temperature
-55 °C to +125 °C
-65 °C to +125 °C
Operating temperature (baseplate)
-40 °C to +100 °C
-55 °C to +100 °C
12 hours, 29 cycles
96 hours, 213 cycles
12 cycles
-65 °C to +100 °C
12 cycles
-65 °C to +100 °C
-40 °C, +80 °C
-55 °C, +80 °C
2 years
2 years
MIL-STD-810
MIL-STD-810
NAVMAT P-4855-1A
NAVMAT P-4855-1A
Power cycling burn-in
Temperature cycled with power off
17°C per minute rate of change
Test data supplied at these temperatures [a]
Warranty
Environmental compliance
Derating
[a] Test data available for review or download from vicorpower.com
ENVIRONMENTAL QUALIFICATIONS
Parameter
Qualification
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40 K ft.).
Altitude
MIL-STD-810D, Method 500.2, Procedure II, 40,000 ft., 1000 – 1500 ft./ min. to 70,000 ft., unit functioning
Explosive Atmosphere
MIL-STD-810C, Method 511.1, Procedure I
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20 g
Vibration
MIL-STD-810D, Method 514.3 random: 10 – 300 Hz @ 0.02 g 2 /Hz, 2000 Hz @ 0.002 g 2 / Hz, 3.9 total G rms
3 hrs /axis. Sine: 30 Hz @ 20 g, 60 Hz @ 10 g, 90 Hz @ 6.6 g, 120 Hz @ 5.0 g, 16.0 total G rms, 3 axes
MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6 db/octave, 7.7 G rms, 1hr/axis
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40 g
MIL-STD-202F, Method 213B, 18 pulses, 60 g, 9 msec
Shock
MIL-STD-202F, Method 213B, 75 g, 11 ms saw tooth shock
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet
Acceleration
MIL-STD-810D, Method 513.3, Procedure II Operational test, 9 g for 1 minute along 3 mutually perpendicular axes
Humidity
MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity
Solder Test
MIL-STD-202, Method 208, 8 hr. aging
Fungus
MIL-STD-810C, Method 508.1
Salt-Fog
MIL-STD-810C, Method 509.1
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-AIM, AC Input Front End Module
Set your site on VICOR at www.vicorpower.com
Rev. 1.4
Page 3 of 5
MECHANICAL DRAWINGS, CONNECTION DIAGRAM
0.01 µF (Two 4700 pF)
Y-Rated Capacitors
F1
0.01 µF Ceramic
F2
L1
N/C
AC IN
GATE IN
0.47 µF
MI-27x/J7x
Driver
GATE OUT
L2/N
+S
GATE IN
C1[b]
PAR
N/C
+OUT
+IN
+OUT
TRIM
–IN
–OUT
Load
–S
GATE OUT
–OUT
0.01 µF Ceramic
MI-AIM
0.01 µF (Two 4700 pF)
Y-Rated Capacitors
[b] 1,200 µF max.
Fuse 1: 7A F03A type recommended
Fuse 2: MI-x7x-xx – Buss PC – TRON 2 – 5 A (450 V)
Figure 1 — MI-AIM Connection diagram, typical application
2.28
(57,9)
in
(mm)
.49
(12,4)
.30±.015
(7,6)±(0,38)
1.30
(33,0)
.65
(16,5)
4
9
3
2.10
(53,4)
.080 Dia (2) places
Solder plate
over copper alloy
8
VI-AIM
MI-AIM
7
2
6
1
5
1.40
1.00 (35,6)
.70 (25,4)
.40 (17,8)
(10,2)
.35± .015
(8,9)±(0,38)
FULL R
.15
(3,8)
.15
(3,8)
Pin #
1
2
3
4
5
6
7
8
9
Function
L1
NC
NC
L2/N
+Out
Gate In
Parallel
Gate Out
–Out
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
Product ID
this surface
1.90
(48,3)
2.40
(61,0)
.22
(5,6) Min.
.50
(12,7)
1.75 Max.
(44,4)
.30 Min.
(7,6)
+.030
(0,76)
-.000
(0)
.01
.12
(3,0)
Aluminum Base
Figure 2 — Mechanical diagram
Note: For alternate packaging options refer to the mechanical drawing page at vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-AIM, AC Input Front End Module
Set your site on VICOR at www.vicorpower.com
Rev. 1.4
Page 4 of 5
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls
are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of
all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR
DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY,
FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER
MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and
operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
MI-AIM, AC Input Front End Module
Set your site on VICOR at www.vicorpower.com
Rev. 1.4
5/2012