VER : A_1 update : 2015.03.16 DC-DC Brick BRH100 SERIES 72/80/96 Watts DESCRIPTION KEY FEATURES Input under Voltage Protection The BRH100 series is a new generation isolated DC-DC converter that uses Over Current Protection (Hiccup Mode) an industry standard quarter-brick structure, and features high efficiency and Short Circuit Protection (Hiccup Mode) power density, operates from an input voltage range of 36 V to 75 V, Over Voltage Protection (Hiccup Mode) provides the rated output voltage of 96V / 53.5V / 24V and the maximum output current of 1A / 1.5A / 3A. Over Temperature Protection (Self-recovery) Remote ON/OFF Control Remote Sense * BRH100-96S BRH100-53.5S BRH100-24S Output Voltage Trim UL60950-1 and CSA C22.2 No. 60950-1-07 Meet UL94V-0 Flammability Requirements Rohs6 Compliant Size: 2.28 x 1.45 x 0.38 Inches (BRH100-24S) Size: 2.28 x 1.45 x 0.5 Inches (BRH100-96S/53.5S)) 3-Years Product Warranty *BRH100-96S and BRH100-24S without this function ELECTRICAL SPECIFICATIONS Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes. Model No. Max Output Wattage (W) Voltage (V.DC.) Input Current (A) (max) No-Load Loss (W) (typ.) Voltage (V.DC.) Regulated Voltage Precision (max.) Current (A) (max.) Line Regulation (LL-HL) (typ.) Load Regulation (0-100%) (typ.) Output Ripple & Noise (peak to peak) (typ.) (Oscilloscope Bandwidth:20 MHz) Efficiency (typ.) 100% Load (Vin = 48 V; TA=25°C (77°F)) 50% Load 20% Load Over Power Protection Over Current Protection Over Voltage Protection Protection Short Circuit Protection (max.) Over Temperature Protection BRH100-24S 72W 48V (36~75V) 2.4A 4W 24V 3% 3A 3% 3% BRH100-53.5S 80W BRH100-96S 96W 3.5A 1.25W 53.5V 1.5% 1.5A 0.5 1.5% 4.0A 2.5W 96V 3% 1A 1% 1% 300 mV 200 mV 2000 mV 92.5% 92.5% 89% 91% 80% 86.5% Hiccup mode Hiccup mode 26.4~33.6V 59~66V (Hiccup mode) (Hiccup mode) Hiccup mode Threshold:100~130°C (typ.) / Hysteresis:5°C (min.) Self-recovery 87% 85% 78% 105~115V (Hiccup mode) BRH100-96S: The values are obtained by measuring the temperature of the PCB near the thermal resistor. others: The values are obtained by measuring the temperature of the hottest power component on the top surface of the converter. Isolation Environment Safety EMC Physical Other Voltage (V.DC.) Operating Temperature Storage Temperature Temperature Coefficient (max.) Humidity MTBF Agency Approvals EMI (Conducted & Radiated Emission) Dimension (L x W x H) Tolerance 0.5 mm Weight Remote Low level (V.DC.) On/Off Voltage High level (V.DC.) On/Off Current Low level (mA) (max.) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 1500 VDC (BRH100-96S: Basic Isolation / others: Functional Isolation) -40°C…+85°C -55°C…+125°C 0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F )) 95% RH 1.5 Million Hours (Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F) CE, UL, TUV UL60950-1 and CSA C22.2 No. 60950-1-07 BRH100-24S: 2.28 x 1.45 x 0.38 Inches ( 57.9 x 36.8 x 9.7 mm ) others:. 2.28 x 1.45 x 0.5 Inches ( 57.9 x 36.8 x 12.7 mm ) 33 g 50 g 38 g -0.7~1.2V 3.5~12V 1mA -1- VER : A_1 update : 2015.03.16 DC-DC Brick BRH100 SERIES 72/80/96 Watts NOTE 1. During the test of input reflected ripple current, the input terminal must be connected to a 12uH inductor and a 220uF electrolytic capacitor. 2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the Vout(+) pin. DERATING http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- VER : A_1 update : 2015.03.16 DC-DC Brick BRH100 SERIES 72/80/96 Watts MECHANICAL DIMENSION BRH100-96S / BRH100-53.5S PIN# 96S 53.5S 1 +DC IN +DC IN 2 ON / OFF CTL ON / OFF CTL 3 -DC IN -DC IN 4 -DC OUT -DC OUT 5 -DC OUT -Sense 6 TRIM TRIM 7 +DC OUT +Sense 8 +DC OUT +DC OUT Note 1. All dimensions in mm [in.] Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.] x.xx± 0.25 mm [x.xxx ± 0.010 in.] 2. Pin 1-3, 5-7 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter with 2.00 ± 0.10 mm [0.080 ± 0.004 in.] diameter standoff shoulders. Pin4 and pin8 are 1.50 ± 0.05 mm [0.060 ± 0.002 in.] diameter with 2.50 ± 0.10 mm [0.098 ± 0.004 in.] diameter standoff shoulders. 3. M3 Screw used to bolt unit’s baseplate to other surfaces (such as heatsink) must not exceed 3.00 mm (0.120 in.) depth below the surface of baseplate. http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3- VER : A_1 update : 2015.03.16 DC-DC Brick BRH100 SERIES 72/80/96 Watts MECHANICAL DIMENSION BRH100-24S PIN# 24S 1 +DC IN 2 ON / OFF CTL 3 -DC IN 4 -DC OUT 5 TRIM 6 +DC OUT Note 1. All dimensions in mm [in.] Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.] x.xx± 0.25 mm [x.xxx ± 0.010 in.] 2. Pin 1-6 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter with 2.00 ± 0.10 mm [0.080 ± 0.004 in.] diameter standoff shoulders http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -4-