BR240 - ARCH Electronics Corp.

VER : A_1
update : 2015.03.16
DC-DC Brick
BR240 SERIES
240 Watts
DESCRIPTION
KEY FEATURES
 Input under Voltage Protection
The BR240 series DC-DC converter are high-efficiency and power density 1/8
 Over Current Protection (Hiccup Mode)
brick isolation modules, rating output voltage 12V, output power 240W. This
 Short Circuit Protection (Hiccup Mode)
series provide the standard 1/8 brick version and the PMBus compatible
 Over Voltage Protection (Hiccup Mode)
version. The latter is compatible with the PMBus1.1 communication protocol,
 Over Temperature Protection (Self-recovery)
backward compatible with the I²C/SMBus protocol, and providing Pre-bias,
 Remote ON/OFF Control
output monitoring and current sharing functions. The BR240 series conform to
the RoHS6 requirement.
 Activates Hardware and Software *
 Digitally Adjusts the Voltage *
 PMBus Revision 1.1 compliant *
 Secondary ON/OFF Control *
 Pre-Bias Function *
 UL60950-1 and CSA C22.2 No. 60950-1-07
 Meet UL94V-0 Flammability Requirements
 Rohs6 Compliant
 Size: 2.3 x 0.9 x 0.5 Inches
 3-Years Product Warranty
*BR240-12S without this function
*BR240-12S without this function
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Max Output Wattage (W)
Voltage (V.DC.)
Input
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage (V.DC.)
Voltage Range (V.DC.)
Output
Protection
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
Efficiency
(Vin = 48 V; TA=25°C (77°F)) (typ.)
Over Power Protection
Over Current Protection
Over Voltage Protection
Short Circuit Protection (max.)
Over Temperature Protection
BR240-12S
240W
48V (36~75V)
10A (Vin= 36 - 75 V; Iout = 20 A)
9.6W (Vin= 36 - 75 V; Iout = 0 A)
12V (Vin= 48 V; Iout = 10 A)
BR240-12S-P
11.64~12.36V (Vin= 40 - 75 V)
11.64~12.36V
10.8~12.36V (Vin= 36 - 40 V)
10.8~12.36V
(Vin= 40 - 75 V; Adjust the voltage by PMBus)
(Vin= 36 - 40 V; Adjust the voltage by PMBus)
20A
0.2% (Vin= 40 - 75 V; Iout = 20 A) / 10% (Vin= 36 - 40 V; Iout = 20 A
3% (Vin = 48 V; Iout = 0 – 20 A)
200 mV (Oscilloscope Bandwidth:20 MHz)
100% Load:95% (Iout = 20 A)
50% Load:94.5% (Iout = 10 A)
30% Load:92.0% (Iout = 6 A)
Hiccup mode
Hiccup mode
15V (14~16V) (Hiccup mode)
5 Arms (Hiccup mode)
Threshold:130°C (typ.) / Hysteresis:15°C (typ.)
Self-recovery (The values are obtained by measuring the temperature of the hottest power
component on the top surface of the converter.)
Isolation
Environment
Safety
EMC
Physical
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity
MTBF
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Weight
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
1500 VDC (Functional Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
1.5 Million Hours
(Telcordia SR332; 80% load; TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
2.3 x 0.9 x 0.5 Inches ( 58.4 x 22.8 x 12.7 mm ) Tolerance 0.5 mm
40 g
-1-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR240 SERIES
240 Watts
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Other
On/Off Voltage
On/Off Current
Primary On/Off Voltage
Primary On/Off Current
Secondary CTL Voltage
BR240-12S
Low level (V.DC.)
High level (V.DC.)
Low level (mA) (max.)
BR240-12S-P
Low level (V.DC.)
-0.7~1.2V (The primary low electric level is effective)
2.8~8V
(The primary low electric level is effective)
1mA
0.7~1.2V
─
High level (V.DC.)
─
2.8~8V
Low level (mA) (max.)
─
Low level (V.DC.)
─
1mA
0~0.8V
High level (V.DC.) (max.)
─
(The low electric level is effective)
Logic Input and Output Pins in the Communications Port
─
Logic Input Low level (V.DC.) (max.)
─
Logic Input High Level (V.DC.) (max.)
─
Logic Output Low Level (V.DC.) (max.)
─
Logic Output High Level (V.DC.) (max.)
─
PMBus Setting-up Time (ns.) (min.)
─
PMBus Holding Time (ns.) (min.)
PMBus Detected Precision (Vin=36 - 75 V; Iout=0 - 20 A;TA = -40°C to +85°C (-40°F to +185°F ))
─
Input Voltage Detected Precision (V.DC.)
Output Voltage Detected Precision (V.DC.) ─
─
Output Current Detected Precision (A)
─
Temperature Detected Precision (°C)
(The low electric level is effective)
(The High Electric Level is Effective)
3.3~3.6V
(The High Electric Level is Effective)
1.1V
3.6V
0.25V
3.6V
100
0
1V
0.2V
1A
5°C
NOTE
1. During the test of input reflected ripple current, the input terminal must be connected to a 12 uH inductor and a 220 uF electrolytic capacitor.
2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the Vout(+) pin.
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR240 SERIES
240 Watts
MECHANICAL DIMENSION
PIN#
Single
1
+DC IN
2
ON / OFF CTL
3
-DC IN
4
-DC OUT
5
+DC OUT
6
SGND
7
SA0
8
PMBus_ALT
9
SA1
10
PMBus_CTL
11
ISHARE
12
PMBus_SCL
13
PMBus_SDA
Note
1. All dimensions in mm [in.]
Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.]
x.xx± 0.25 mm [x.xxx ± 0.010 in.]
2. Pin 1-3 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter with 2.00 ± 0.10 mm
[0.080 ± 0.004 in.] diameter standoff shoulders.
Pin4 and pin5 are 1.50 ± 0.05 mm [0.060 ± 0.002 in.] diameter with 2.50 ± 0.10
mm [0.098 ± 0.004 in.] diameter standoff shoulders.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-