Datasheet Varitector High Density Surge Protection NEW All Varitector models include high quality field connections and are grounded via the DIN-rail. A combination of gas discharge tubes, varistors and suppression diodes in single or multi-stage configuration are used to protect nominal voltages between 5 VDC and 230 VAC. Status monitoring options help ensure continued protection. VSPC modules feature local and remote signaling of arrestor status, while many of the VSSC6 models have an option for an integral LED, which signals when module replacement is required. The Varitector range complements the Weidmuller’s SPD II range of surge protectors for low voltage power distribution applications. Taken together, these products provide extensive DIN-rail mounted surge protection capability for industrial installations. Weidmuller’s Varitector range offers low-cost, highdensity surge protection options for lightning and other transient protection in industrial control equipment. UL (497B) approved, Varitector is ideally suited for signaling (I/O) applications such as analog current and voltage loops, DC and AC status signals and a wide variety of serial interface and telephone network installations. Models for hazardous area and SIL options are available. The Varitector range includes two construction formats, VSSC and VSPC. VSSC models feature 4- or 6-pole rugged, compact terminal-sized housings. VSPC models feature a two part, plug-and-base format for easy arrestor replacement without re-wiring. Both formats are DIN-rail mounted, rated for discharge currents up to 20kA (8/20μs), and provide a combination of wire-to-ground and wire-to-wire protection. Features: • T wo formats – high density terminal (VSSC), or pluggable, replaceable arrestor (VSPC) • Imax = 20kA (8/20µs) • Local or remote indication options for arrestor status • Grounding via DIN-rail or field connection • UL497B approval • Color coded line voltage identification • A ccessories include test meter and EMC Set (easy shield connector) Weidmuller, Canada Weidmuller, Mexico Weidmuller, United States 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email: [email protected] Website: www.weidmuller.ca Blvd. Hermanos Serdán 698 Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email: [email protected] Website: www.weidmuller.com.mx 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email: [email protected] Website: www.weidmuller.com Overview VARITECTOR SPC VARITECTOR SPC Pluggable surge protection for the measurement and control industry VARITECTOR SPC Weidmuller's VARITECTOR SPC pluggable surge protection is remarkable for its combination of extremely high protective functionality and compact dimensions. It is suited for use in measurement and control circuits. The size is made possible by the seletion of INSTA dimensions, with a width of 17.8 mm (1TE). Two versions are available: • VSPC: a surge protector with no monitoring function • VSPC R: a surge protector with monitoring function The base components are plugged in to form a direct earthing contact via the mounting rail. Thus you save time during the connection. The VARITECTOR SPC series is optimally designed for compact installation locations in process automation, industrial automation or building automation. The two-stage surge-protection base components are equipped with gas discharge tubes, suppressor diodes (TVS) and decoupling components. Individual protective components (such as gas-filled spark gaps, varistors and suppressor diodes) supplement this product line. IEC 62305 requires that a periodic inspection of surge protection products be conducted. The functionality of all VARITECTOR SPC modules can be tested using testing equipment (such as the V-TEST Basic) that is available separately. The VARITECTOR SPC R modules also feature an internal monitoring function. The green LED signals when the protection function is ready. The red LED signals an error. VARITECTOR SPC Up to ten modules can be wired together in series. The modules alert an evaluative module (the VSPC CONTROL UNIT) in the event of an error. VARITECTOR SPCseries surge protection is available with rated voltages of 5 V, 12 V, 24 V, 48 V and 60 V. The product's voltage level is Color-coded on the pluggable arrester. An earthing contact is established by snapping onto an earthed TS35 rail. The TS35 must be earthed in order to ensure safe power discharging via the terminals of up to 20 kA (8/20 µs) and 2.5 kA (10/350 µs). The rail must be screwed onto the earthed mounting plate for reasons of EMC. In order to optimize the protective function, a PE-contact connection should be made over the VSPC module every 60 cm for equipotential bonding. The pluggable protective element can be pulled out during operations without interrupting the measurement circuit. A testing instrument, available as a Weidmuller accessory, allows you to test the protective element in compliance with the IEC 62305-3 directive. The accessory also includes a simple mechanism for applying the wire shield. Overview of model types A VARITECTOR SPC (VSPC) consists of a pluggable component and a separate base component (VSPC BASE). Explanation of terms: CL = current loop / analog signals SL = symmetric loop - for binary signals VSPC 2CL (CL = current loop) is a twostage protective combination with a gas discharge tube and a suppressor diode located between the current paths. This VSPC 2CL limits the surge voltage within two analog signal circuits (such as for current loops). This pluggable component can be inserted into the base (VSPC BASE 2CL). The base (VSPC BASE FG 2CL) is used when working with signal circuits which are not earthed. The VSPC 2CL HF is used in order to avoid influencing high-frequency signal circuits (this also includes the VSPC RS485 and the VSPC UK0). This protective combination is also inserted into the base mentioned above. Monitoring function The VSPC 2CL R products feature monitor and alert functions. Despite the alert function, there are still two channels 2 VARITECTOR SPC available for current loops in a single housing. The special VSPC BASE 2CL R and VSPC BASE 2CL FG R bases transfer the alert function to a 2-pole screw/plug-in connection in the bases and to the VSPC CONTROL UNIT. The VSPC 1CL is a two-stage protective combination with a gas discharge tube and a suppressor diode located between the current paths. This VSPC 1CL limits the surge voltage within one analog signal circuits (such as for current loops). This pluggable component can be inserted into the base (VSPC BASE 1CL). The base (VSPC BASE FG 1CL) is used when working with signal circuits which are not earthed. Monitoring function The VSPC 1CL R products feature monitor and alert functions. All channels remain despite the alert function. The special VSPC BASE 1CL R and VSPC BASE 1CL FG R bases transfer the alert function to a 2-pole screw/plug-in connection in the bases and to the VSPC CONTROL UNIT. The VSPC 4SL is a two-stage protective combination with a gas discharge tube and a suppressor diode from the current 3 Overview path to the PE. This VSPC 4SL limits the surge voltage within four binary signal circuits (such as for alert contacts). This pluggable component can be inserted into the base (VSPC BASE 4SL). The base (VSPC BASE FG 4CL) is used when working with signal circuits which are not earthed. VSPC CONTROL UNIT. Monitoring function The VSPC 4SL R products feature monitor and alert functions. Despite the alert function, there are still channels available for the four binary signal circuits in a single housing. The special VSPC BASE 4SL R base transfers the alert function to a 2-pole screw/plug-in connection in the base and to the VSPC CONTROL UNIT. The VSPC 3/4WIRE is a two-stage protective combination with a gas discharge tube and a suppressor diode from the current path to the GND. This VSPC 3/4WIRE limits the surge voltage within four temperature-measurement circuits (such as for DMS or PT100/100 sensors). For non-earthed measurement circuits, we recommend using the base (VSPC BASE FG 4CL). The VSPC 2SL is a two-stage protective combination with a gas discharge tube and a suppressor diode from the current path to the PE. This VSPC 2SL limits the surge voltage within two binary signal circuits (such as for alert contacts). This pluggable component can be inserted into the base (VSPC BASE 2SL). The base (VSPC BASE 2CL FG) is used when working with signal circuits which are not earthed. VSPC MOV 2CH , VSPC TAZ 2CH und VSPC GDT 2CH Four cables can be protected with the 2CH modules. By wiring the connections differently, either two no-voltage signal lines or four binary signal lines can be protected. Two three-pole gas discharge tubes (GDTs) are used for the VSPC GDT 2CH. This universal protective circuitry limits the voltage between the signal lines and also between each signal line and the PE. Monitoring function The VSPC 2SL R products feature monitor and alert functions. Despite the alert function, there are still channels available for the two binary signal circuits in a single housing. The special VSPC BASE 2SL R base transfers the alert function to a 2-pole screw/plug-in connection in the base and to the Overview VARITECTOR SPC Applications RS 422/485 The VSPC RS485 is a two-stage protective combination with a gas discharge tube and a suppressor diode located between the current paths. This VSPC RS485 limits the surge voltage within two high-frequency signal circuits. This pluggable component can be inserted into the base (VSPC BASE 2CL). The base (VSPC BASE FG 2CL) is used when working with signal circuits which are not earthed. The VSPC MOV 2CH and TAZ 2CH offer one-stage protection with a varistor (MOV) or suppressor diode (TAZ or TVS) between the current paths. This makes it possible to protect a no-voltage (floating) signal circuit. Two binary signal circuits can also be protected if terminals 1 and 7 are assigned to GND / PE. These VSPC pluggable components are inserted into the base (VSPC BASE 2/4CH). The base (VSPC BASE 2/4CH FG) is used when working with signal circuits which are not earthed.. 24 V VSPC 1CL PW (power and signal 1CL) offers combined protection that is suitable for the 24 VDC power supply and the current loops within a device. This VSPC protects sensors with an additional 24 VDC. Monitoring function The VSPC RS485 R product features monitoring and alert functions. Despite the alert function, there are still two channels available for current loops in a single housing. The special VSPC BASE 2CL R and VSPC BASE 2CL FG R bases transfer the alert function to a 2-pole screw/plug-in connection in the bases and to the VSPC CONTROL UNIT. Earthing unit and test plug The earthing unit can be used during installation to short out the connected wires to earth. The earthing unit is swapped out for a VSPC pluggable component before the initial commissioning. The test plug has 2.3 mm sockets. These sockets can be used by a meter to check the connected measurement circuit.. The pluggable INSTA housing was created in compliance with DIN 43880. It consists of a lower section (the VSPC BASE) and a pluggable component (the VSPC). The VSPC BASE is made from black PA6.6 V0. The pluggable component is made from red PA6.6 V0. The temperature range is from -40 °C to + 70 °C. The VSPC series has been tested to comply with IEC 61643-21 04/2008 and EN 61643-21. Modules were tested with categories C1, C2 and C3: with quick-rising edges with up to 300 pulses. Category D1 describes high power testing (10/350 μs), so that the VSPC can be used according to IEC 62305-4. The base and pluggable components are Color coded according to the voltage level. This makes installation easier. Color coding The pluggable components transfer their coding to the base element when they are plugged in for the first time. The voltage levels are also labelled with Colored Dekafix markers applied to the VSPC pluggable component. This gives you a better overview within the electrical cabinet. Voltage level ≤ 12 V Color green 24 V Binary 24 V Analog 48 V ≥ 60 V Special function blue yellow red violet white 4 VARITECTOR SPC Remote error diagnostics Test possibility / V-TEST Because the modules are pluggable, it is possible to test the VSPC visually or by using a V-TEST BASIC testing device. The VSPC can be easily tested; the user needs only to insert the VSPC pluggable component into the V-TEST BASIC. The result is then shown on the display. The VSPC R modules also feature an internal monitoring function for the arrester. An error is the displayed at the defective module. The VSPC CONTROL UNIT can then transfer an alert to the control room. Reoccurring tests / V-TEST Monitoring The IEC 62305-3 requires testing and maintenance for lightning protection systems. This includes the testing of the arresters used in the system. Class of protection Interval for complete testing I 2 years Interval for visual inspection 1 year II III/IV 4 years 6 years 2 years 3 years Caution! These periodic inspections may be extended with stricter requirements pertaining to special applications or regions. 5 Overview When the VSPC module labelled "R" is inserted into the corresponding "R" base component, it is then possible to use the outage alert function via a two-pole plug. This screw/plug-in connection has a clamping range from 0.5 to 1.5 mm². The wire stripping length is 6 to 6.5 mm. A screwdriver with a 2 mm blade width is used to turn the screw. The VSPC Rs are connected in series to the VSPC CONTROL UNIT evaluative module. Up to ten VSPC Rs can be connected in series to the VSPC CONTROL UNIT. The evaluative module is supplied with 24 VDC. It is then responsible for the switching and for the voltage supply to the VSPC modules. A no-voltage (floating) CO contact can then be used to alert in the event of an outage. The error is also displayed directly on the module when the LED changes Color from green to red. An automatic reset is carried out by the VSPC CONTROL UNIT within one minute after the failed VSPC pluggable component is replaced. Installation The VSPC series is appropriate for protecting signal circuits. In order to achieve a complete protective strategy for the facility, the power feed must be protected against Class-II surge voltages (for example, by using the PU II series). For existing lightning protection facilities, Class-I protection must be used (for example, by using the PU I series). Class-II protection (for example, the PU II) is sufficient when there is no lightning protection facility. Fusing The VSPC surge protection modules are designed so that they are decoupled between the individual protective stages. The following must be observed when providing fuse protection externally: • Max. rated current • Deratings curve • Type of installation • Application O v e r v i e w VARITECTOR SPC Discharge capacity General technical data Accessories Testing is conducted using voltage and current pulses according to the IEC 61643-21 standard concerning surge protection in networks which process signals. Storage temperature -40 °C…+80 °C Operating temperature: -40 °C…+70 °C Air humidity 5%…96% RH with no condensation Material: V0, IP20 Markers The VSPC BASE lower section can be labelled with Dekafix-5 markers. The VSPC pluggable modules are Color coded with Dekafix-5 markers according to their rated voltage. Cate- Testing gory pulse C1 Quickrising edge Surge voltage 0.5 - 2 kV with 1.2/50 µs Surge Pulse Type current 0.25 - 1 kA 300 Surge mit voltage 8/20 µs arrester C2 Quickrising edge 2 - 10 kV 1 - 5 kA with mit 1.2/50 µs 8/20 µs C3 Quickrising edge ≥ 1 kV with 1 kV/µs 10 - 100 A 300 mit 10/10000 µs Surge voltage arrester D1 High power ≥ 1 kV 0.5 - 2.5 kA 2 mit 10/350 µs Arrester for lightning current and surge voltages 10 Surge voltage arrester Category C reflects the interference pulses with quick-rising edges and minimized power. Category D uses quick-rising edges and high power to detail the interference pulses. This energy simulates the high-power load that stems from coupled partial lightning currents. Connection: screw connection screwdriver blade: 0.6 x 3.5 DIN 5264 (for example, 0.6 x 3.5 x 200, Part No. 9010110000) rated torque: 0.5 Nm max. torque: 0.8 Nm stripping length: 7 mm solid: 0.5…4 mm² flexible: 0.5…2.5 mm² wire-end ferrule with plastic collar: 0.5...2.5 mm² Remote signalling connection: screw connection screwdriver blade: 0.4 x 2.0 DIN 5264 (for example, SD 0.4 x 2.0 x 60, Part No. 9037160000) max. torque: 0.2 Nm stripping length: 6...6.5 mm solid: 0.5...1.5 mm² Shield connection EMC SET, order number 1067470000 The EMC set consists of a connection component with shielding and a cable tie covered with shielding braid. The RT-1 cable tie tool (order number 1296000000) can be used to fasten the cable ties professionally. V-Test Testing device for functional tests of the pluggable VSPC, PU II and PU I surge protection. Dimensions length : 90 mm length with remote signalling contact: 98 mm height: 69 mm width: 17.8 mm 6 VARITECTOR SPC Choice of device depending on the interface VARITECTOR SPC – Choice of device depending on the interface Interface Pluggable arrestor Pluggable arrestor with operation message (R) VSPC 2CL 24Vdc 0,5A R VSPC 1CL 12Vdc 0,5A R VSPC 2CL 24Vdc 0,5A R VSPC 1CL 12Vdc 0,5A R Part No. Arrestor 8951480000 8951540000 8951480000 8951540000 Part No. Base 8951710000 8951730000 8951710000 8951730000 Part No. Base floating ground (FG) 8951720000 8951740000 8951720000 8951740000 0(4) … 20 mA 0(4) … 20 mA 0 … 10 V 0 … 10 V ADSL ADVANT ARCNET (Plus) ASI 8951680000 8951670000 8860350000 8860360000 8951470000 8951470000 8951540000 8951690000 8951690000 8951690000 8951690000 8951710000 8951710000 8951720000 8951720000 8924270000 8924270000 8924290000 8924270000 8924270000 8924270000 8924270000 VSPC 2CL HF 5Vdc R VSPC R485 2ch R PU III R 48Vdc PU III R 24Vdc VSPC 2CL 12Vdc 0,5A R VSPC 2CL 12Vdc 0,5A R VSPC 1CL 12Vdc 0,5A R VSPC 2CL HF 12Vdc R VSPC 2CL HF 12Vdc R VSPC 2CL HF 12Vdc R VSPC 2CL HF 12Vdc R 8951710000 8951710000 8951730000 8951710000 8951710000 8951710000 8951710000 8951720000 8951720000 8951740000 8951720000 8951720000 8951720000 8951720000 8924270000 8924270000 8924270000 8924290000 8924290000 VSPC 2CL HF 12Vdc R VSPC 2CL HF 12Vdc R VSPC 2CL HF 12Vdc R VSPC 1CL 12Vdc 0,5A R VSPC 1CL 24Vdc 0,5A R 8951690000 8951690000 8951690000 8951540000 8951550000 8951710000 8951710000 8951710000 8951730000 8951730000 8951720000 8951720000 8951720000 8951740000 8951740000 VSPC 1CL 5Vdc 0,5A 8924420000 8924730000 8924290000 VSPC 1CL 5Vdc 0,5A R 8951530000 VSPC Uko 8924660000 8924710000 8924270000 VSPC 2CL HF 5Vdc 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 FIPIO/FIPWAY VSPC 2CL HF 5Vdc 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 Genius I/O Bus VSPC 2CL 12Vdc 0,5A 8924440000 8924710000 8924270000 VSPC 2CL 12Vdc 0,5A R 8951470000 Hart VSPC 1CL 24Vdc 0,5A 892448 0000 8924730000 8924290000 VSPC 1CL 24Vac 0,5A R 8951560000 HDSL VSPC Uko 8924660000 8924710000 8924270000 IEC-BUS VSPC 2CL HF 5Vdc 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 8924660000 8924710000 8924270000 ISDN Basic connec- VSPC Uko tion (Uk0-Bus) 8924570000 8924740000 8924300000 Cathodic corrosion VSPC GDT 2ch 90V20kA prevention LON (Works) VSPC 1CL 48Vac 0,5A 8924520000 8924730000 8924290000 LRE Networks VSPC 2CL HF 5Vdc 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 LUXMATE-Bus VSPC 2CL HF 24Vdc 8924510000 8924710000 8924270000 VSPC 2CL HF 24Vdc R 8951700000 VSPC 1CL 24Vac 0,5A 8924500000 8924730000 8924290000 VSPC 1CL 24Vdc 0,5A R 8951550000 M-Bus (Remote readout of counter) MODBUS(-PLUS) VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 MPI-Bus VSPC R485 2ch 8924670000 8924710000 8924270000 N1 LAN VSPC 2CL HF 5Vdc 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 N2 Bus VSPC 2SL 5Vdc 0,5A 8924210000 8924720000 8924280000 VSPC 2SL 5Vdc 0,5A R 8951610000 P-NET VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 VSPC 1CL 12Vdc 0,5A 8924450000 8924730000 8924290000 VSPC 1CL 12Vdc 0,5A R 8951540000 Procontic CS31 VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 Procontic T200 VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 Profibus DP (FMS) VSPC 2CL HF 5Vdc VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 Process-Bus, Panel-Bus 8924550000 8924740000 8924300000 PT100 VSPC 3/4WIRE 24VDC P-Bus PU III R 24Vdc 8860360000 PU III R 24Vdc 8860360000 PSM-EG-RS422… VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 PSM-EG-RS485… VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 RACKBUS VSPC 2CL HF 5Vdc 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 RS 422A, V.11, X.27, RS 423A RS 449 VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 RS 485 VSPC R485 2ch 8924670000 8924710000 8924270000 VSPC R485 2ch R 8951670000 RS-232-C/V.24 VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 SDLC VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 SDSL VSPC Uko 8924660000 8924710000 8924270000 SecuriLan-LON-Bus VSPC 1CL 12Vdc 0,5A 8924450000 8924730000 8924290000 VSPC 1CL 12Vdc 0,5A R 8951540000 SHDSL VSPC Uko 8924660000 8924710000 8924270000 SINEC L1 VSPC 2CL HF 5Vdc 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 SINEC L2 DP VSPC 2CL HF 5Vdc 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 Profibus DP VSPC R485 2ch 8924670000 8924710000 8924270000 VSPC R485 2ch R 8951670000 T-DSL VSPC Uko 8924660000 8924710000 8924270000 Telephone analog VSPC Uko 8924660000 8924710000 8924270000 TTY, 0(4) - 20 mA VSPC 2CL 24Vdc 0,5A 8924470000 8924710000 8924270000 VSPC 2CL 24Vdc 0,5A R 8951480000 U-BUS VSPC GDT 2ch 90V20kA 8924570000 8924740000 8924300000 VDSL VSPC Uko 8924660000 8924710000 8924270000 V.35 VSPC 2CL HF 5Vdc 8924430000 8924710000 8924270000 VSPC 2CL HF 5Vdc R 8951680000 X.21/X.24 VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 X.25/X.31 VSPC 2CL HF 12Vdc 8924460000 8924710000 8924270000 VSPC 2CL HF 12Vdc R 8951690000 This tables contains recommendations for the choice of device. Our technical consultants will be glad to assist you with your individual requirements. 8951730000 8951740000 8951710000 8951710000 8951710000 8951730000 8951720000 8951720000 8951720000 8951740000 8951710000 8951720000 8951710000 8951710000 8951730000 8951720000 8951720000 8951740000 8951710000 8951710000 8951710000 8951770000 8951710000 8951730000 8951710000 8951710000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 8951780000 8951720000 8951740000 8951720000 8951720000 8951720000 8951720000 8951720000 8951710000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 8951720000 8951710000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 8951720000 8951730000 8951740000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 8951710000 8951720000 8951710000 8951710000 8951710000 8951720000 8951720000 8951720000 BITBUS BLN (Building Level Network) CAN-Bus C-BUS CC-LINK Data Highway (Plus), DH+ Datex-P DeviceNet DIN Detecting Bus System Dupline/Miniplex EIB (European Installation Bus) ET 200 E1 7 VSPC 2CL 24Vdc 0,5A VSPC 1CL 24Vdc 0,5A VSPC 2CL 24Vdc 0,5A VSPC 1CL 24Vdc 0,5A VSPC Uko VSPC 2CL HF 5Vdc VSPC R485 2ch PU III R 48Vdc PU III R 24Vdc VSPC 2CL HF 12Vdc VSPC 2CL HF 12Vdc VSPC 1CL 24Vdc 0,5A VSPC 2CL HF 12Vdc VSPC 2CL HF 12Vdc VSPC 2CL HF 12Vdc VSPC 2CL HF 12Vdc Part No. Arrestor 8924470000 8924480000 8924470000 892448 0000 8924660000 8924430000 8924670000 8860350000 8860360000 8924460000 8924460000 892448 0000 8924460000 8924460000 8924460000 8924460000 Part No. Base 8924710000 8924730000 8924710000 8924730000 8924710000 8924710000 8924710000 Part No. Base floating ground (FG) 8924270000 8924290000 8924270000 8924290000 8924270000 8924270000 8924270000 8924710000 8924710000 8924730000 8924710000 8924710000 8924710000 8924710000 VSPC 2CL HF 12Vdc VSPC 2CL HF 12Vdc VSPC 2CL HF 12Vdc VSPC 1CL 12Vdc 0,5A VSPC 1CL 24Vdc 0,5A 8924460000 8924460000 8924460000 8924450000 892448 0000 8924710000 8924710000 8924710000 8924730000 8924730000 VARITECTOR SPC 8 V VA AR RIIT TE EC CT TO OR RS SP PC C VSPC 1CL – Protection for one analog signal • O ptional monitoring function with status indicator and alert function • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Testable with V-TEST instrument • Version with non-earthed PE connection for avoiding potential differences • Usable in accordance with installations standard IEC 62305 • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC 1CL Dielectric strength with FG against PE > 500 V Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 2.2 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 1 kA 10/350 µs Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE Type of connection Storage temperature Ambient temperature (operational) Rel. humidity 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Base element, direct earthing with remote alert Base element, indirect earthing with remote alert Note: The basis elements are to be ordered separately 9 Qty. 1 Part No. 8924730000 1 1 1 8924290000 8951730000 8951740000 VARITECTOR SPC VSPC 1CL – Arrester / plug-in elements Ordering Data VSPC 1CL 5 V DC VSPC 1CL 12 V DC VSPC 1CL 24 V DC 5 V DC 12 V DC 24 V DC 6.4 V DC 15 V DC 28 V DC 450 mA 450 mA 450 mA UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 730 KHz 20 ms acc. to IEC61643-21 < 650 V 12 V / 450 V / 650 V with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 730 KHz 20 ms acc. to IEC61643-21 < 650 V 25 V / 450 V / 650 V with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 730 KHz 30 ms acc. to IEC61643-21 < 650 V 45 V / 450 V / 650 V < 12 V < 12 V < 25 V < 25 V < 45 V < 45 V < 450 V < 650 V < 450 V < 650 V < 450 V < 650 V VSPC 1CL 5VDC 0.5A VSPC 1CL 12VDC 0.5A VSPC 1CL 24VDC 0.5A 8924420000 8924450000 8924480000 VSPC 1CL 5VDC 0.5A R 8951530000 1 piece VSPC 1CL 12VDC 0.5A R 8951540000 1 piece VSPC 1CL 24VDC 0.5A R 8951550000 1 piece VSPC 1CL 24 V AC VSPC 1CL 48 V AC VSPC 1CL 60 V AC Rated voltage (DC) 24 V AC / 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC Max. continuous voltage, Uc (DC) Alternating-current strength Rated current Surge strength Signaling contact 28 V AC / 39 V DC 60 V AC / 85 V DC 72 V AC / 101 V DC 450 mA 350 mA 250 mA Rated voltage (DC) Max. continuous voltage, Uc (DC) Alternating-current strength Rated current Surge strength Signaling contact Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. Ordering data Without signaling contact/function indicatorType Part No. With signaling contact/function indicator Type Part No. Qty. Note Ordering Data UN 250 V AC 0.1 A 1CO at VSPC R Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. Ordering data Without signaling contact/function indicatorType Part No. with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 730 KHz 30 ms acc. to IEC61643-21 < 650 V 60 V / 450 V / 650 V no no green = OK; red = arrester faulty, replace 730 KHz 100 ms acc. to IEC61643-21 < 650 V 85 V / 450 V / 650 V green = OK; red = arrester faulty, replace 730 KHz 100 ms acc. to IEC61643-21 < 650 V 100 V / 450 V / 650 V < 60 V < 85 V < 100 V < 60 V < 85 V < 100 V < 450 V < 450 V < 450 V < 650 V < 650 V < 650 V VSPC 1CL 24VAC 0.5A VSPC 1CL 48VAC 0.5A VSPC 1CL 60VAC 0.5A 8924500000 8924520000 8924530000 1 piece 1 piece With signaling contact/function indicator Type Part No. VSPC 1CL 24VAC 0.5A R 8951560000 Qty. Note 1 piece 10 VARITECTOR SPC VSPC 2CL – Protection for two analog signals • O ptional monitoring function with status indicator and alert function • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Testable with V-TEST instrument • Space-saving design for two analog signals with signaling contact, without additional space requirements • Version with non-earthed PE connection for avoiding potential differences • U sable in accordance with installations standard IEC 62305 • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC 2CL Dielectric strength with FG against PE > 500 V Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 2.2 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 1 kA 10/350 µs Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE Degree of protection Type of connection Storage temperature Ambient temperature (operational) 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10kA 2.5 kA / 2.5 kA / 2.5 kA IP20 Pluggable in VSPC BASE -40 °C…+80 °C -40 °C…+70 °C Rel. humidity 5 %…96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Base element, direct earthing with remote alert Base element, indirect earthing with remote alert Note: The basis elements are to be ordered separately 11 Qty. 1 Part No. 8924710000 1 1 1 8924270000 8951710000 8951720000 VARITECTOR SPC VSPC 2CL – arrester / plug-in elements Ordering Data VSPC 2CL 5 V DC VSPC 2CL 12 V DC VSPC 2CL 24 V DC 5 V DC 12 V DC 24 V DC 6.4 V DC 15 V DC 28 V DC 450 mA 450 mA 450 mA UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 730 KHz 20 ms acc. to IEC61643-21 < 800 V 12 V / 450 V / 800 V with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 2.4 MHz 20 ms acc. to IEC61643-21 < 800 V 25 V / 450 V / 800 V with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 2.2 MHz 30 ms acc. to IEC61643-21 < 800 V 45 V / 450 V / 800 V < 12 V < 12 V < 25 V < 25 V < 45 V < 45 V < 450 V < 800 V < 450 V < 800 V < 450 V < 800 V VSPC 2CL 5VDC 0.5A VSPC 2CL 12VDC 0.5A VSPC 2CL 24VDC 0.5A 8924400000 VSPC 2CL 5VDC 0.5A R 8951460000 8924440000 VSPC 2CL 12VDC 0.5A R 8951470000 8924470000 VSPC 2CL 24VDC 0.5A R 8951480000 1 piece 1 piece 1 piece VSPC 2CL 24 V AC VSPC 2CL 48 V AC VSPC 2CL 60 V AC Rated voltage (DC) 24 V AC / 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC Max. continuous voltage, Uc (DC) Alternating-current strength Rated current Surge strength Signaling contact 28 V AC / 39 V DC 60 V AC / 85 V DC 72 V AC / 101 V DC 450 mA 350 mA 250 mA Rated voltage (DC) Max. continuous voltage, Uc (DC) Alternating-current strength Rated current Surge strength Signaling contact Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. Ordering data Without signaling contact/function indicatorType Part No. With signaling contact/function indicator Type Part No. Qty. Note Ordering Data UN 250 V AC 0.1 A 1CO at VSPC R Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. Ordering data Without signaling contact/function indicatorType Part No. With signaling contact/function indicator Type Part No. Qty. Note with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 3 MHz 450 ms acc. to IEC61643-21 < 650 V 60 V / 450 V / 800 V no no green = OK; red = arrester faulty, replace 3 MHz 500 ms acc. to IEC61643-21 < 650 V 85 V / 450 V / 650 V green = OK; red = arrester faulty, replace 7 MHz 500 ms acc. to IEC61643-21 < 650 V 100 V / 450 V / 650 V < 60 V < 60 V 500 ms < 85 V < 85 V 500 ms < 100 V < 100 V < 450 V < 800 V < 450 V < 650 V < 450 V < 650 V VSPC 2CL 24VAC 0.5A VSPC 2CL 48VAC 0.5A VSPC 2CL 60VAC 0.5A 8924490000 VSPC 2CL 24VAC 0.5A R 1093400000 8951490000 8951500000 1 piece 1 piece 1 piece 12 V A R I T E C T O R S P C VSPC 2CL HF – For high transmission rates without signal delays • O ptional monitoring function with status indicator and alert function • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Testable with V-TEST instrument • Space-saving design with optional signaling contact, without additional space requirements • High transmission rates with low attenuation values • Usable in accordance with installations standard IEC 62305 • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC 2CL HF Dielectric strength with FG against PE > 500 V Rated current Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 450 mA 2.2 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs Surge strength D1 1 kA 10/350 µs Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE Degree of protection Type of connection Storage temperature Ambient temperature (operational) Rel. humidity 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10kA 2.5 kA / 2.5 kA / 2.5 kA IP20 Pluggable in VSPC BASE -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Base element, direct earthing with remote alert Base element, indirect earthing with remote alert Note: The basis elements are to be ordered separately 13 Qty. 1 Part No. 8924710000 1 1 1 8924270000 8951710000 8951720000 VARITECTOR SPC VSPC 2CL HF – Arrester / plug-in elements Ordering Data VSPC 2CL HF 5 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 24 V DC 5 V DC 12 V DC 24 V DC 6.4 V DC 15 V DC 28 V DC UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 1.5 MHz 20 ms acc. to IEC61643-21 < 800 V 12 V / 450 V / 800 V with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 1.5 MHz 20 ms acc. to IEC61643-21 < 800 V 25 V / 450 V / 800 V with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 1.5 MHz 40 ms acc. to IEC61643-21 < 800 V 45 V / 450 V / 800 V Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. < 12 V < 12 V < 25 V < 25 V < 45 V < 45 V Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. < 450 V < 800 V < 450 V < 800 V < 450 V < 800 V VSPC 2CL HF 5VDC VSPC 2CL HF 12VDC VSPC 2CL HF 24VDC 8924430000 VSPC 2CL HF 5VDC R 8951680000 8924460000 VSPC 2CL HF 12VDC R 8951690000 8924510000 VSPC 2CLHF 24VDC R 8951700000 1 piece 1 piece 1 piece Rated voltage (DC) Max. continuous voltage, Uc (DC) Alternating-current strength Surge strength Signaling contact Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Ordering data Without signaling contact/function indicatorType Part No. With signaling contact/function indicator Type Part No. Qty. Note 14 VARITECTOR SPC VSPC 1CL PW – Combinations of current loop signal and circuit breaker • O ptional monitoring function with status indicator • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • U sable in accordance with installations standard IEC 62305 • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC 1CL PW C&I protection data Rated voltage (DC) Max. continuous voltage, Uc (DC) Dielectric strength with FG against PE Rated current Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Optical function indicator Rated voltage (AC/DC) Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 Transmission test (-3dB) Impulse reset Tested Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE Residual voltage Up Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1 kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Protection of the device Rated voltage (DC) Max. continuous voltage, Uc (DC) Combined pulse Residual voltage Up Rated current General data Type of connection Storage temperature Requirement category acc. to IEC 61643-1 Ambient temperature (operational) Rel. humidity Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 24 V AC / 34 V DC 27 V AC / 38 V DC > 500 V 450 mA 2.2 Ω Mode 2 C1; C2; C3; D1 green = OK; red = arrester faulty, replace 24 V AC / 33 V DC < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs 730 KHz 10 ms acc. to IEC61643-21, IEC61643-1 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA 800 V 60 V / 450 V / 800 V < 60 V < 60 V < 450 V < 800 V 24 V AC / 34 V DC 27 V AC / 38 V DC 6 kV 900 V 10 A Pluggable in VSPC BASE -40 °C…+80 °C Class III -40 °C…+70 °C 5 %…96 % RH IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Note: The basis elements are to be ordered separately 15 Qty. 1 Part No. 1070230000 1 1105700000 VARITECTOR SPC VSPC 1CL PW – Arrester / plug-in elements Ordering Data VSPC 1CL PW 24 V Without signaling contact/function indicatorType Part No. Qty. Note VSPC 1CL PW 24V 0.5A 8951510000 1 piece 16 VARITECTOR SPC VSPC 2SL – Protection for two binary signals • O ptional monitoring function with status indicator and alert function • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Testable with V-TEST instrument • Version with non-earthed PE connection for avoiding potential differences • U sable in accordance with installations standard IEC 62305 • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC 2SL Dielectric strength with FG against PE > 500 V Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 4.7 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE Type of connection Storage temperature Ambient temperature (operational) Rel. humidity 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Base element, direct earthing with remote alert Base element, indirect earthing with remote alert Note: The basis elements are to be ordered separately 17 Qty. 1 Part No. 8924720000 1 1 1 8924280000 8951770000 8951780000 VARITECTOR SPC VSPC 2SL – Arrester / plug-in elements Ordering Data Rated voltage UN VSPC 2SL 5 V DC VSPC 2SL 12 V DC VSPC 2SL 12 V AC VSPC 2SL 24 V DC 24 V DC 5 V DC 12 V DC 12 V AC / 16 V DC 6.4 V DC 15 V DC 13,2 V AC / 18 V DC UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 750 KHz 20 ms acc. to IEC61643-21 < 25 V 25 V / 25 V / 25 V UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 750 KHz 20 ms acc. to IEC61643-21 < 50 V 45 V / 50 V / 50 V green = OK; red = arrester faulty, replace 750 KHz 20 ms acc. to IEC61643-21 < 50 V 55 V / 50 V / 50 V UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 750 KHz 30 ms acc. to IEC61643-21 < 60 V 80 V / 60 V / 60 V Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. < 25 V < 25 V < 45 V < 45 V < 55 V < 55 V < 80 V < 80 V Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. < 12 V < 25 V < 25 V < 50 V < 30 V < 50 V < 40 V < 60 V 300 mA 300 mA 300 mA 300 mA VSPC 2SL 5VDC 0.5A VSPC 2SL 12VDC 0.5A VSPC 2SL 12VAC 0.5A VSPC 2SL 24VDC 0.5A 8924210000 VSPC 2SL 5VDC 0.5A R 8951610000 8924230000 VSPC 2SL 12VDC 0.5A R 8951620000 8924250000 8924330000 VSPC 2SL 24VDC 0.5A R 8951630000 1 piece 1 piece 1 piece 1 piece VSPC 2SL 24 V AC VSPC 2SL 48 V AC VSPC 2SL 60 V AC Rated voltage UN 24 V AC / 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC Max. continuous voltage UC Signaling contact 28 V AC / 39 V DC 60 V AC / 85 V DC 72 V AC / 101 V DC Max. continuous voltage UC Signaling contact Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Rated current Ordering data Without signaling contact/function indicatorType Part No. With signaling contact/function indicator Type Part No. Qty. Note Ordering Data no UN 250 V AC 0,1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 750 KHz 60 ms acc. to IEC61643-21 < 60 V 80 V / 60 V / 60 V no no green = OK; red = arrester faulty, replace 750 KHz 60 ms acc. to IEC61643-21 < 125 V 80 V / 125 V / 125 V green = OK; red = arrester faulty, replace 750 KHz 60 ms acc. to IEC61643-21 < 165 V 80 V / 165 V / 165 V Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. < 110 V < 80 V < 210 V < 80 V < 280 V < 80 V Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. < 60 V < 60 V < 85 V < 125 V < 100 V < 165 V 300 mA 250 mA 200 mA VSPC 2SL 24VAC 0.5A VSPC 2SL 48VAC 0.5A VSPC 2SL 60VAC 0.5A 8924350000 VSPC 2SL 24VAC 0.5A R 8951640000 8924370000 8924390000 1 piece 1 piece 1 piece Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Rated current Ordering data Without signaling contact/function indicatorType Part No. With signaling contact/function indicator Type Part No. Qty. Note 28 V DC 18 VARITECTOR SPC VSPC 4SL – Protection for four binary signals • O ptional monitoring function with status indicator and alert function • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Testable with V-TEST instrument • Space-saving design for four binary signals with signaling contact, without additional space requirements • Version with non-earthed PE connection for avoiding potential differences • U sable in accordance with installations standard IEC 62305 • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC 4SL Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 4.7 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE Type of connection Storage temperature Ambient temperature (operational) Rel. humidity 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 °C … +80 °C -40 °C … +70 °C 5 % … 96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Base element, direct earthing with remote alert Base element, indirect earthing with remote alert Note: The basis elements are to be ordered separately 19 Qty. 1 Part No. 8924700000 1 1 1 8924260000 8951750000 8951760000 VARITECTOR SPC VSPC 4SL – Arrester / plug-in elements Ordering Data Rated voltage UN VSPC 4SL 5 V DC VSPC 4SL 12 V DC VSPC 4SL 12 V AC VSPC 4SL 24 V DC 24 V DC 5 V DC 12 V DC 12 V AC / 16 V DC 6.4 V DC 15 V DC 13.2 V AC / 18 V DC UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 730 KHz 20 ms acc. to IEC61643-21 < 25 V 25 V / 25 V / 25 V UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 750 KHz 20 ms acc. to IEC61643-21 < 35 V 45 V / 20 V / 450 V green = OK; red = arrester faulty, replace 750 KHz 20 ms acc. to IEC61643-21 < 50 V 55 V / 50 V / 50 V UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 750 KHz 30 ms acc. to IEC61643-21 < 60 V 80 V / 60 V / 60 V Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. < 25 V < 25 V < 45 V < 45 V < 55 V < 55 V < 80 V < 80 V Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. < 12 V < 25 V < 25 V < 50 V < 30 V < 50 V < 40 V < 60 V 350 mA 300 mA 300 mA 300 mA VSPC 4SL 5VDC 0.5A VSPC 4SL 12VDC 0.5A VSPC 4SL 12VAC 0.5A VSPC 4SL 24VDC 0.5A 8924200000 VSPC 4SL 5VDC 0.5A R 8951570000 8924220000 VSPC 4SL 12VDC 0.5A R 8951580000 8924240000 8924320000 VSPC 4SL 24VDC 0.5A R 8951590000 1 piece 1 piece 1 piece 1 piece VSPC 4SL 24 V AC VSPC 4SL 48 V AC VSPC 4SL 60 V AC Rated voltage UN 24 V AC / 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC Max. continuous voltage UC Signaling contact 28 V AC / 39 V DC 60 V AC / 85 V DC 72 V AC / 101 V DC Max. continuous voltage UC Signaling contact Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Rated current Ordering data Without signaling contact/function indicatorType Part No. With signaling contact/function indicator Type Part No. Qty. Note no UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 750 KHz 40 ms acc. to IEC61643-21 < 60 V 80 V / 60 V / 60 V no no green = OK; red = arrester faulty, replace 750 KHz 60 ms acc. to IEC61643-21 < 125 V 80 V / 125 V / 125 V green = OK; red = arrester faulty, replace 750 KHz 60 ms acc. to IEC61643-21 < 165 V 80 V / 165 V / 165 V Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. < 110 V < 80 V < 210 V < 80 V < 280 V < 80 V Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. < 60 V < 60 V < 85 V < 125 V < 100 V < 165 V Rated current 300 mA 250 mA 200 mA VSPC 4SL 24VAC 0.5A VSPC 4SL 48VAC 0.5A VSPC 4SL 60VAC 0.5A Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Without signaling contact/function indicatorType With signaling contact/function indicator Type Part No. 8924340000 VSPC 4SL 24VAC 0.5A R 8951600000 Qty. 1 piece Part No. 28 V DC 8924380000 1 piece 1 piece 20 VARITECTOR SPC VSPC 4SL WIRE – 3/4 conductor, measurement • P luggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Protection of measuring bridge signals • Testable with V-TEST instrument • U sable in accordance with installations standard IEC 62305 • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC 4SL WIRE Rated current 450 mA Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 0.2 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE Type of connection Storage temperature Ambient temperature (operational) Rel. humidity 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 °C…+80 °C -40 °C...+70 °C 5 %...96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Note: The basis elements are to be ordered separately 21 Qty. 1 Part No. 8924740000 1 8924300000 VARITECTOR SPC VSPC 4SL WIRE – Arrester / plug-in elements Ordering Data Rated voltage (DC) VSPC 3/4WIRE 5 V DC VSPC 3/4WIRE 24 V DC 3 V DC 24 V DC 6.4 V DC < 800 V 730 KHz 28 V DC < 800 V 730 KHz < 20 ms acc. to IEC61643-21 < 800 V 35 V / 800 V / 500 V < 30 ms acc. to IEC61643-21 < 800 V 50 V / 800 V / 800 V Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. < 35 V < 35 V < 50 V < 50 V Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. < 250 V < 800 V < 270 V < 800 V VSPC 3/4WIRE 5VDC VSPC 3/4WIRE 24VDC 8924540000 8924550000 1 piece 1 piece Max. continuous voltage, Uc (DC) Residual voltage Up Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Ordering data Without signaling contact / Function indicator Type Part No. Qty. Note 22 VARITECTOR SPC VSPC GDT – with components Pluggable arrester with components: GDT • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Testable with V-TEST instrument • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC GDT Dielectric strength with FG against PE > 500 V Volume resistivity per path Overstressed fault mode Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 Type of connection < 0.2 Ω Mode 2 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs Pluggable in VSPC BASE Storage temperature Ambient temperature (operational) Rel. humidity -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Note: The basis elements are to be ordered separately 23 Qty. 1 Part No. 8924740000 1 8924300000 VARITECTOR SPC VSPC GDT – Arrester / plug-in elements Ordering Data VSPC GDT 2CH 90 V VSPC GDT 2CH 150 V AC/230 V DC Rated voltage (DC) 48 V AC / 68 V DC 110 V AC / 150 V DC Max. continuous voltage, Uc (DC) Signaling contact Rated current Transmission test (-3dB) Impulse reset Tested Rated discharge current IN (8/20 µs) 50 V AC / 72 V DC no 2000 mA 125 V AC / 180 V DC no 2000 mA 3 MHz 3 MHz in accordance with IEC61643-21 in accordance with IEC61643-21 wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) 2 x 2.5 kA / - / 2.5 kA 2 x 2.5 kA / - / 2.5 kA wire-wire / wire-PE / GND-PE Rated discharge current, Iimp. (10/350 µs) wire-wire / wire-PE / GND-PE Residual voltage Up wire-wire / wire-PE / GND-PE 2 x 10 kA / - / 10 kA 2 x 10 kA / - / 10 kA 2 x 0.2 kA / - / 0.2 kA < 1000 V 650 V / 1000 V / - 2 x 0.2 kA / - / 0.2 kA < 800 V 800 V / 800 V / - < 650 V < 1000 V < 450 V < 800 V C1; C2; C3; D1 C1; C2; C3; D1 VSPC GDT 2ch 90V20kA VSPC GDT 2CH 150Vac/230Vdc 8924570000 8924590000 1 piece 1 piece Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. Requirement category acc. to IEC 61643-21 Ordering data Without signaling contact/function indicatorType Part No. With signaling contact/function indicator Type Part No. Qty. Note 24 VARITECTOR SPC VSPC MOV – with components Pluggable arrester with components: MOV • Optional monitoring function with status display and alert function for MOV components • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Testable with V-TEST instrument • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC MOV Dielectric strength with FG against PE > 500 V Volume resistivity per path Overstressed fault mode Surge strength C1 Surge strength C2 Surge strength D1 Type of connection Storage temperature < 0.2 Ω Mode 1 < 1 kA / 8/20 µs 1.5 kA / 8/20 µs; 1 kA / 8/20 μs at VSPC R 0.5 kA 10/350 μs Pluggable in VSPC BASE -40 °C…+80 °C Ambient temperature (operational) Rel. humidity -40 °C…+70 °C 5 %…96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Base element, direct earthing with remote alert Base element, indirect earthing with remote alert Note: The basis elements are to be ordered separately 25 Qty. 1 Part No. 8924740000 1 1 1 8924300000 8951790000 8951800000 VARITECTOR SPC VSPC MOV – Arrester / plug-in elements Ordering Data VSPC MOV 2CH 24 V Rated voltage (DC) Max. continuous voltage, Uc (DC) Rated current Transmission test Tested Surge strength C3 Rated discharge current, limp (10/350 μs) wire-wire / wire-PE / GND-PE Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. Requirement category acc. to IEC 61643-21 Ordering data Without signaling contact/function indicator Type Part No. Qty. Note Ordering Data Rated voltage (DC) Max. continuous voltage, Uc (DC) Signaling contact Optical function indicator (VSPC R) Rated current Transmission test Tested Surge strength C3 Rated discharge current, limp (10/350 μs) wire-wire / wire-PE / GND-PE Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. Requirement category acc. to IEC 61643-21 Ordering data With signaling contact/function indicator Type Part No. Qty. Note VSPC MOV 2CH 230 V 24 V AC 230 V AC 30 V AC / 42 V DC 10 A 1 MHz 275 V AC / 385 V DC 10 A 1 MHz acc. to IEC61643-21 100 A / 10/1000 μs acc. to IEC61643-21 50 A / 10/1000 μs 0.2 kA / - / 0.5 kA 0.2 kA / - / 0.5 kA 1.5 kA / - / 1.5 kA 1.5 kA / - / 1.5 kA 1.5 kA / - / 1.5 kA < 95 V 80 V / - / - 1.5 kA / - / 1.5 kA < 850 V 850 V / - / - < 80 V < 95 V < 600 V < 700 V C1; C2; C3; D1 C1; C2; C3; D1 VSPC MOV 2CH 24V 8kA VSPC MOV 2ch 230V8kA 8924600000 8924610000 1 piece 1 piece VSPC MOV 2CH 24 V R VSPC MOV 2CH 230 V R 24 V AC 230 V AC 30 V AC / 42 V DC 275 V AC / 385 V DC UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 10 A 1 MHz acc. to IEC61643-21 100 A / 10/1000 μs with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 10 A 1 MHz acc. to IEC61643-21 50 A / 10/1000 μs 0.2 kA / - / 0.5 kA 0.2 kA / - / 0.5 kA 1 kA / - / 1 kA 1 kA / - / 1 kA 1 kA / - / 1 kA < 200 V 200 V / - / - 1 kA / - / 1 kA < 850 V 850 V / - / - < 80 V < 95 V < 600 V < 700 V C1; C2; C3; D1 C1; C2; C3; D1 VSPC MOV 2CH 24V R VSPC MOV 2ch 230V R 8951650000 8951660000 1 piece 1 piece 26 VARITECTOR SPC VSPC TAZ – components Pluggable arrester with components: TAZ • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Testable with V-TEST instrument • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC TAZ Dielectric strength with FG against PE > 500 V Rated current Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C3 Type of connection Storage temperature 10 A < 0.2 Ω Mode 2 C3 20 A / 10/1000 µs Pluggable in VSPC BASE -40 °C…+80 °C Ambient temperature (operational) Rel. humidity -40 °C…+70 °C 5 %…96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Note: The basis elements are to be ordered separately 27 Qty. 1 Part No. 8924740000 1 8924300000 VARITECTOR SPC VSPC TAZ – Arrester / plug-in elements Ordering Data VSPC TAZ 2 CH 24 V AC VSPC TAZ 4 CH 24 V Rated voltage (DC) 24 V AC / 34 V DC 24 V AC / 34 V DC Max. continuous voltage, Uc (DC) 28 V AC / 39 V DC 1 MHz 28 V AC / 39 V DC 1 MHz in accordance with IEC61643-21 55 V / - / - in accordance with IEC61643-21 - / 55 V / - < 50 V < 55 V < 50 V < 55 V VSPC TAZ 2ch24Vac 0.1kA VSPC TAZ 4ch24V 0.1kA 8924640000 8924650000 1 piece 1 piece Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. Ordering data Without signaling contact / Function indicator Type Part No. Qty. Note 28 VARITECTOR SPC VSPC TELE UK0 for the Uk0/S0 interface in telecommunication • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Low residual voltage • 2-wire input interface – Uk0 • Testable with V-TEST instrument • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC TELE UK0 Dielectric strength with FG against PE > 500 V Rated current Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 450 mA 2.2 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs Surge strength D1 2.5 kA 10/350 µs Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE Type of connection Storage temperature Ambient temperature (operational) Rel. humidity 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 0.2 kA / 2 x 0.2 kA / 0.2 kA Pluggable in VSPC BASE -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Note: The basis elements are to be ordered separately 29 Qty. 1 Part No. 8924710000 1 8924270000 VARITECTOR SPC VSPC TELE UK0 / VSPC RS485 – Arrester / plug-in elements Ordering Data VSPC TELE UK0 2WIRE Rated voltage (DC) 127 V AC Max. continuous voltage, Uc (DC) 180 V DC 1 MHz 60 ms Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE in accordance with IEC61643-21 800 V 250 V / 450 V / 650 V Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. < 250 V < 300 V Protection level on output side unsym.,input 1 kV/μs, typ. input 8/20 μs, typ. < 450 V < 800 V Ordering data Without signaling contact / Function indicator Type Part No. Qty. Note VSPC TELE UK0 2WIRE 8924660000 1 piece 30 VARITECTOR SPC VSPC RS485 For serial data transmission • Optional monitoring function with status indicator and alert function • Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral) • Low residual voltage • Protection for conducted serial data transmission – RS485 • Testable with V-TEST instrument • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data for all VSPC RS485 Dielectric strength with FG against PE > 500 V Rated current Volume resistivity per path Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 450 mA 2.2 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs Surge strength D1 2.5 kA 10/350 µs Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE Type of connection Storage temperature Ambient temperature (operational) Rel. humidity 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 2 x 10 kA / 10 kA 0.2 kA / 2 x 0.2 kA / 0.2 kA Pluggable in VSPC BASE -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 0.5 0.45 Current [mA] 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 10 20 30 40 50 60 70 80 90 100 Temperature [°C] Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R) Length x width x height 90 x 17.8 x 69 mm 98 x 17.8 x 69 mm Note Base elements / base to arresters Ordering Data for Base Type Base element, direct earthing Base element, indirect earthing via spark gap (FG, floating ground) Base element, direct earthing with remote alert Base element, indirect earthing with remote alert Note: The basis elements are to be ordered separately 31 Qty. 1 Part No. 8924710000 1 1 1 8924270000 8951790000 8951800000 VARITECTOR SPC VSPC RS485 – Arrester / plug-in elements Ordering Data VSPC RS485 2CH Rated voltage (DC) 5 V DC Max. continuous voltage, Uc (DC) 6,4 V DC UN 250 V AC 0,1 A 1CO at VSPC R Signaling contact Optical function indicator (VSPC R) Transmission test (-3dB) Impulse reset Tested Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym., input 1 kV/μs, typ. input 8/20 μs, typ. Protection level on output side unsym., input 1 kV/μs, typ. input 8/20 μs, typ. Ordering data Without signaling contact / Function indicator With signaling contact / Function indicator Type Part No. Type Part No. Qty. Note with VSPC CONTROL UNIT green = OK; red = arrester faulty, replace 4 MHz 20 ms acc. to IEC61643-21 35 V 15 V / 35 V / 500 V < 10 V < 15 V < 10 V < 35 V VSPC RS485 2CH 8924670000 VSPC RS485 2CH R 8951670000 1 piece 32 VARITECTOR SPC VSPC CONTROL UNIT 24 V DC • • • • • • For monitoring up to 10 protective modules Signaling module for all VSPCs with status indicator Signaling of cable breaks / signal interruptions Voltage supply from 18...31 V DC Potential-free changeover contact Function indicator (red/green LED) Technical Data 24 V 0V Input Rated voltage (DC) 18 V…24 V DC…31 V DC X2 Rated current max. 50 mA X1 Power rating Output Current loop 1.5 W Monitoring option Signal output Type 1…10 VSPC modules Max. switching voltage / continuous current Diagnostics Operating status 250 V / 1 A Defect at current loop Red LED (control unit and defective module) Wire breakage General data Terminal rail Red/green LED, flashing Design, Protection class Type of connection Storage temperature Ambient temperature (operational) Rel. humidity Insta-enclosure, IP20 BL / SL -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH Start-up time after fault correction Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 60 s 12 11 VSPC CONTROL UNIT X2 X1 X2 X1 14 X2 X1 nmax = 10 n=2 n=1 VSPC...R VSPC...R VSPC...R 8 mA bei < 51 V 1 CO contact Green LED TS35 Dimensions Dimensions incl. enclosure L x W x H Note Applikation 102 x 18 x 71.5 mm Ordering Data VSPC CONTROL UNIT 24 V DC Type Part No. Qty. Note 33 VSPC CONTROL UNIT 24Vdc 8972270000 1 piece Accessories VARITECTOR SPC VSPC Accessories V-Test • Instrument for testing the protective functions of series: PU I, PU II and VSPC • Device for realizing standard IEC 62305 (periodic testing) • Handy device with integrated battery set for local measurements • Result display via LCD display • Bilingual menu • Including protective bag and power supply • Intuitive user navigation in German and English The V-Test is a compact, portable instrument for the Varitector SPC pluggable surge protection (VSPC series) and surge protection for power distribution, PUI and II series. With this instrument, the Weidmuller surge protection can be tested for protective function in accordance with the required test periods as stipulated by IEC62305 (DIN VDE 185 Part 3). In a backlit display, the measurement result is indicated with "ok" or "not ok" for each component. Technical Data Rated voltage 100...240 V AC Accumulator set Storage temperature Ambient temperature (operational) Degree of protection Measuring range UL94 flammability class 8 NiMH with 2600 mA 0 °C ... 40 °C 0 °C ... 40 °C IP20 U < 1000 V / I = 1 mA V0 General tolerances of measurement range Gas discharge tube +/- 10% Varistor +/- 5% TVS-diode +/- 5% Note Ordering Data V-Test Dimensions Length x width x height Ordering data Type Part No. Qty. Note 230 x 122 x 65 mm V-Test 8951860000 1 34 VARITECTOR SPC Accessories VSPC Accessories V-Ground • Can be applied to unassigned wires • Usable during start-up and maintenance • Earthing of all sensor cables • Can be plugged into standard base sockets V-Test-Connector • Usable during start-up and maintenance • For circuit voltage measurements using a standard 2.3-mm test socket • Can be plugged into standard base sockets Technical Data Rated voltage (DC) 230 V AC Max. continuous voltage, Uc (DC) 255 V AC < 0.5 A < 0.2 Ω Pluggable in VSPC BASE -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH Rated current Volume resistivity per path Type of connection Storage temperature Ambient temperature (operational) Rel. humidity Degree of protection Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 IP20 Note Ordering Data Arrester / plug-in elements VSPC TEST Connector 24 DC VSPC GROUND VSPC TEST Connector 24DC VSPC GROUND 8924690000 8924680000 1 1 Type Part No. Qty. Note Ordering Data Shield connection: Complete set - cable ties and shield connection Cable ties Shield connection Cable tie tool 35 Type EMC set Qty. 1 Part No. 1067470000 EMC tie EMC connector Cable tie tool RT-1 100 50 1 1067490000 1067520000 1296000000 VARITECTOR SPC 36 VARITECTOR SPC VSPC 1CL EX – Protection for an analog signal in intrinsically safe circuits • P luggable arrester (impedance neutral plugging/ unplugging without interruption) • Can be tested with the V-TEST testing device • Space-saving design for 1 analog signal • Version with floating ground PE connection used to avoid differences in voltage potential • Can be used in compliance with the IEC 62305 installation standard • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Can be used in zone 2, 1 and 0 • Certified for IEC 61643-21:08 D1, C1, C2, C3 Technical Data Arresters / Plugs General data Dielectric strength at FG against PE > 500 V Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 2.2 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 µs) wire-wire / wire-PE / GND-PE Connection Storage temperature Ambient temperature (operational) Rel. humidity Degree of protection 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH IP20 Flammability class EX protection data Inner capacitance, max. Ci V0 Inner inductance, max. Li Temperature class T6/85 °C ( -40 °C…+60 °C) Ii Temperature class T5/100 °C ( -40 °C…+75 °C) Ii Temperature class T4/135 °C ( -40 °C…+85 °C) Ii 0 µH 250 mA 250 mA 350 mA Input power, max. Pi Failure probability λges 3W MTTF 2537 years ATEX Approval: T II 1 G EX ia IIC T4…T6 Ga T II 1 D Ex ia IIIC T135°C…T85°C Da EU-type examination certificate No.: KEMA 10ATEX0148 X 37 Note < 4 nF 45 VARITECTOR SPC VSPC 1CL EX Arresters / plugs Bases and arresters should be ordered separately Arrester / Plug Arrester / plug Base / socket VSPC 1CL 5 V DC EX VSPC 1CL 12 V DC EX VSPC 1CL 24 V DC EX Technical data Rated voltage (DC) Max. continuous voltage Uc (DC) Input voltage, max. Ui Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage Up wire-wire / wire-PE / GND-PE 5 V DC 12 V DC 24 V DC 6,4 V DC 6V 730 KHz 15 V DC 14 V 730 KHz 28 V DC 26 V 730 KHz 20 ms < 650 V 12 V / 450 V / 650 V 20 ms < 650 V 25 V / 450 V / 650 V 30 ms < 650 V 45 V / 450 V / 650 V < 12 V < 12 V < 25 V < 25 V < 45 V < 45 V < 450 V < 650 V < 450 V < 650 V < 450 V < 650 V IEC61643-21, IEC 62305, EN 60079-0.2009, EN 60079-11:2007, EN 60079-26:2007, EN 61241-11:2006 IEC61643-21, IEC 62305, EN 60079-0.2009, EN 60079-11:2007, EN 60079-26:2007, EN 61241-11:2006 IEC61643-21, IEC 62305, EN 60079-0.2009, EN 60079-11:2007, EN 60079-26:2007, EN 61241-11:2006 VSPC 1CL 5VDC ATEX VSPC 1CL 12VDC ATEX VSPC 1CL 24VDC ATEX 8953660000 8953590000 8953600000 1 1 1 VSPC BASE 1CL FG EX VSPC BASE 1CL FG EX VSPC BASE 1CL FG EX 0.5 mm² / 4 mm² 0.5 mm² / 4 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 7 mm 0.5...0.8 Nm 7 mm 0.5...0.8 Nm 7 mm 0.5...0.8 Nm VSPC BASE 1CL FG EX VSPC BASE 1CL FG EX VSPC BASE 1CL FG EX 8951810000 8951810000 8951810000 1 1 1 Protection level on output side sym. Input 1 kV/µs, typ. Input 8/20 µs, typ. Protection level on output side unsym., Input 1 kV/µs, typ. Input 8/20 µs, typ. Standards Note Ordering Data Arrester / plug Type Part No. Qty. Note Base / Socket Technical data Clamping range, Rated connection, min./max. Conductor cross section, flexible, min./max. solid, min./max. stranded, min./max. Stripping length Tightening torque Note Ordering Data Base / socket Indirect earthing via gas dischargedType tube FG, floating ground Part No. Qty. Size of complete module (arrester + base) Length x width x height Note: 90 x 17.8 x 69 mm 90 x 17.8 x 69 mm 90 x 17.8 x 69 mm Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 38 VARITECTOR SPC VSPC 2CL EX – Protection for an analog signal in intrinsically safe circuits • P luggable arrester (impedance-neutral plugging/ unplugging without interruption) • Can be tested with the V-TEST testing device • Space-saving design for 2 analog signals • Version with floating ground PE connection used to avoid differences in voltage potential • Can be used in compliance with the IEC 62305 installation standard • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Can be used in zone 2, 1 and 0 • Certified for IEC 61643-21:08 D1, C1, C2, C3 Technical Data Arresters / Plugs General data Dielectric strength at FG against PE > 500 V Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 2.2 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE 10 kA / 2 x 10 kA / 10 kA Lightning test current, Iimp. (10/350 µs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA Connection Pluggable in VSPC BASE Storage temperature -40 °C…+80 °C Ambient temperature (operational) -40 °C…+70 °C Rel. humidity 5 %…96 % RH Degree of protection IP20 Flammability class EX protection data Inner capacitance, max. Ci V0 Inner inductance, max. Li Temperature class T6/85 °C ( -40 °C…+60 °C) Ii Temperature class T5/100 °C ( -40 °C…+75 °C) Ii Temperature class T4/135 °C ( -40 °C…+85 °C) Ii 0 µH 250 mA 250 mA 350 mA Input power, max. Pi Failure probability λges 3W 45 MTTF 2537 years ATEX Approval: T II 1 G EX ia IIC T4…T6 Ga T II 1 D Ex ia IIIC T135°C…T85°C Da EU-type examination certificate No.: KEMA 10ATEX0148 X 39 Note < 4 nF VARITECTOR SPC VSPC 2CL EX Arresters / plugs Bases and arresters should be ordered separately Arrester / plug Arrester / Plug Base / socket VSPC 2CL 24 V DC EX Technical data Rated voltage (DC) 24 V DC Max. continuous voltage Uc (DC) Input voltage, max. Ui 28 V DC 26 V 2.2 MHz Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage Up wire-wire / wire-PE / GND-PE 30 ms < 800 V 45 V / 450 V / 800 V Protection level on output side sym. < 45 V < 45 V Input 1 kV/µs, typ. Input 8/20 µs, typ. Protection level on output side unsym., Input 1 kV/µs, typ. Input 8/20 µs, typ. < 450 V < 800 V IEC61643-21, IEC 62305, EN 60079-0.2009, EN 60079-11:2007, EN 60079-26:2007, EN 61241-11:2009 Standards Note Ordering Data Arrester / plug Type Part No. Qty. Note VSPC 2CL 24VDC ATEX 8953720000 1 VSPC BASE 2CL FG EX Base / Socket Technical data Clamping range, Rated connection, min./max. 0.5 mm² / 4 mm² Conductor cross section, flexible, min./max. solid, min./max. stranded, min./max. 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 7 mm 0.5...0.8 Nm Stripping length Tightening torque Note Ordering Data Base / socket Indirect earthing via gas dischargedType tube FG, floating ground Part No. Qty. Size of complete module (arrester + base) Length x width x height Note: VSPC BASE 2CL FG EX 8951820000 1 90 x 17.8 x 69 mm Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 40 VARITECTOR SPC VSPC 1CL PW EX – Combinations of current-loop signal and device protection in intrinsically safe circuits • P luggable arrester (impedance neutral plugging/ unplugging without interruption) • Can be used to comply with the IEC 62305 installation standard • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Can be used in zone 2, 1 and 0 • Certified for IEC 61643-21:08 D1, C1, C2, C3 • Certified for IEC 61643-11:09 class III Technical Data Arresters / Plugs Protection for the current loop Rated voltage (DC) Max. continuous voltage Uc (DC) Dielectric strength at FG against PE Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Rated voltage (AC/DC) Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 Signal transmission properties (-3 dB) Pulse reset capacity 27 V AC / 38 V DC > 500 V 2.2 Ω Mode 2 C1; C2; C3; D1 24 V AC / 33 V DC < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs 730 KHz 10 ms Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 µs) wire-wire / wire-PE / GND-PE Residual voltage Up Residual voltage Up wire-wire / wire-PE / GND-PE Protection level on output side sym. input 1 kV/µs, typ. Protection level on output side sym., input 8/20 µs, typ. Protection level on output side unsym., input 1 kV/µs, typ. Protection level on output side unsym., input 8/20 µs, typ. 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA 800 V 60 V / 450 V / 800 V < 60 V < 60 V < 450 V < 800 V Standards IEC 61643-21, IEC 61643-1, IEC 62305, EN 600790.2009, EN 60079-11:2007, EN 60079-26:2007, EN 61241-11:2009 Protection for Energy line III Rated voltage (DC) Max. continuous voltage UC (AC) / (DC) EU-type examination certificate No.: KEMA 10ATEX0148 X 41 24 V AC / 34 V DC Combined pulse Residual voltage Up 27 V AC / 38 V DC 6 kV 900 V Nominal current 0.35 A ATEX Approval: T II 1 G EX ia IIC T4…T6 Ga T II 1 D Ex ia IIIC T135°C…T85°C Da 24 V AC / 34 V DC Note VARITECTOR SPC VSPC 1CL PW EX Arresters / plugs Bases and arresters should be ordered separately Arrester / plug Arrester / Plug Base / socket VSPC 1CL PW 24 V EX Technical data Pluggable in VSPC BASE Type of connection Ambient temperature (operational) Storage temperature Requirement category acc. to IEC 61643-1 -40 °C…+70 °C -40 °C…+80 °C Class III 5 %…96 % RH Rel. humidity EX protection data Degree of protection IP20 Flammability class Inner capacitance, max. Ci Inner inductance, max. Li Temperature class T6/85°C (-40°C…+60°C) Ii Temperature class T5/100°C (-40°C…+75°C) Ii Temperature class T4/135°C (-40°C…+85°C) Ii Input power, max. Pi V0 < 4 nF 0 µH 250 mA 250 mA 350 mA 3W 20 V Input voltage, max. Ui Failure probability λges 45 2537 years MTTF Note Ordering Data Arrester / plug Type Part No. Qty. Note VSPC 1CL PW 24V 0,5A 8951510000 1 VSPC BASE 1CL PW FG EX Base / Socket Technical data Clamping range, Rated connection, min./max. 0.5 mm² / 4 mm² Conductor cross section, flexible, min./max. solid, min./max. stranded, min./max. 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 7 mm Stripping length 0.5...0.8 Nm Tightening torque Note Ordering Data Base / socket Indirect earthing via gas dischargedType tube FG, floating ground Part No. Qty. Size of complete module (arrester + base) Length x width x height Note: VSPC BASE 1CL PW FG EX 1070470000 1 90 x 17.8 x 69 mm Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 42 VARITECTOR SPC VSPC 2SL EX – Protection for two binary signals in intrinsically safe circuits • P luggable arrester (impedance neutral plugging/ unplugging without interruption) • Can be tested with the V-TEST testing device • Space saving design for 2 binary signals • Version with floating ground PE connection used to avoid differences in voltage potential • Can be used to comply with the IEC 62305 installation standard • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Can be used in zone 2, 1 and 0 • Certified for IEC 61643-21:08 D1, C1, C2, C3 Technical Data Arresters / Plugs General data Dielectric strength at FG against PE > 500 V Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 4.7 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 µs) wire-wire / wire-PE / GND-PE Type of connection Storage temperature Ambient temperature (operational) Rel. humidity Degree of protection 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 °C…+80 °C -40 °C…+70 °C 5 %…96 % RH IP20 Flammability class EX protection data Inner capacitance, max. Ci V0 Inner inductance, max. Li Temperature class T6/85 °C ( -40 °C…+60 °C) Ii Temperature class T5/100 °C ( -40 °C…+75 °C) Ii 0 µH 250 mA 250 mA Input power, max. Pi Failure probability λges 3W 43 MTTF 2655 years ATEX Approval: T II 1 G EX ia IIC T4…T6 Ga T II 1 D Ex ia IIIC T135°C…T85°C Da EU-type examination certificate No.: KEMA 10ATEX0148 X 43 Note < 4 nF VARITECTOR SPC VSPC 2SL EX Arresters / plugs Bases and arresters should be ordered separately Arrester / plug Arrester / Plug VSPC 2SL 12 V DC EX Base / socket VSPC 2SL 12 V AC EX VSPC 2SL 24 V DC EX VSPC 2SL 48 V AC EX 12 V DC 12 V AC / 16 V DC 24 V DC 48 V AC / 68 V DC 15 V DC 14 V 300 mA 13.2 V AC / 18 V DC 19 V 300 mA 28 V DC 26 V 300 mA 60 V AC / 85 V DC 75 V 250 mA 750 KHz 20 ms IEC 61643-21, IEC 62305, EN 60079-0.2009, EN 6007911:2007, EN 60079-26:2007, EN 61241-11:2009 < 50 V 45 V / 50 V / 50 V 750 KHz 20 ms IEC 61643-21, IEC 62305, EN 60079-0.2009, EN 6007911:2007, EN 60079-26:2007, EN 61241-11:2009 < 50 V 55 V / 50 V / 50 V 750 KHz 30 ms IEC 61643-21, IEC 62305, EN 60079-0.2009, EN 6007911:2007, EN 60079-26:2007, EN 61241-11:2009 < 60 V 80 V / 60 V / 60 V 750 KHz 60 ms IEC 61643-21, IEC 62305, EN 60079-0.2009, EN 6007911:2007, EN 60079-26:2007, EN 61241-11:2009 < 125 V 80 V / 125 V / 125 V Protection level on output side sym. Input 1 kV/µs, typ. Input 8/20 µs, typ. < 45 V < 45 V < 55 V < 55 V < 80 V < 80 V < 210 V < 80 V Protection level on output side unsym., Input 1 kV/µs, typ. Input 8/20 µs, typ. < 25 V < 50 V < 30 V < 50 V < 40 V < 60 V < 85 V < 125 V 300 mA 300 mA 300 mA 250 mA VSPC 2SL 12VDC 0.5A ATEX VSPC 2SL 12VAC 0.5A ATEX VSPC 2SL 24VDC 0.5A ATEX VSPC 2SL 48VAC 0.5A ATEX 8953620000 8953630000 8953670000 8953640000 1 1 1 1 VSPC BASE 2SL FG EX VSPC BASE 2SL FG EX VSPC BASE 2SL FG EX VSPC BASE 2SL FG EX 0.5 mm² / 4 mm² 0.5 mm² / 4 mm² 0.5 mm² / 4 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 7 mm 0.5...0.8 Nm 7 mm 0.5...0.8 Nm 7 mm 0.5...0.8 Nm 7 mm 0.5...0.8 Nm VSPC BASE 2SL FG EX VSPC BASE 2SL FG EX VSPC BASE 2SL FG EX VSPC BASE 2SL FG EX 8951830000 8951830000 8951830000 8951830000 1 1 1 1 Technical data Rated voltage UN Max. continuous voltage UC (AC) / (DC) Input voltage, max. Ui Temperature class T4/135°C (-40°C…+85°C) Ii Signal transmission properties (-3 dB) Pulse reset capacity Standards Residual voltage Up wire-wire / wire-PE / GND-PE Nominal current Note Ordering Data Arrester / plug Type Part No. Qty. Note Base / Socket Technical data Clamping range, Rated connection, min./max. Conductor cross section, flexible, min./max. solid, min./max. stranded, min./max. Stripping length Tightening torque Note Ordering Data Base / socket Indirect earthing via gas dischargedType tube FG, floating ground Part No. Qty. Size of complete module (arrester + base) Length x width x height Note: 90 x 17.8 x 69 mm 90 x 17.8 x 69 mm 90 x 17.8 x 69 mm 90 x 17.8 x 69 mm Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 44 VARITECTOR SPC VSPC 4SL EX – Protection for four binary signals in intrinsically safe circuits • P luggable arrester (impedance neutral plugging/ unplugging without interruption) • Can be tested with the V-TEST testing device • Space saving design for 4 binary signals • Version with floating ground PE connection used to avoid differences in voltage potential • Can be used to comply with the IEC 62305 installation standard • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Can be used in zone 2, 1 and 0 • Certified for IEC 61643-21:08 D1, C1, C2, C3 Technical Data Arresters / Plugs General data Volume resistivity 4.7 Ω Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 µs) wire-wire / wire-PE / GND-PE Type of connection Storage temperature Ambient temperature (operational) Rel. humidity Degree of protection 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 °C … +80 °C -40 °C … +70 °C 5 % … 96 % RH IP20 Flammability class EX protection data Inner capacitance, max. Ci V0 Inner inductance, max. Li Temperature class T6/85 °C ( -40 °C…+60 °C) Ii Temperature class T5/100 °C ( -40 °C…+75 °C) Ii Temperature class T4/135 °C ( -40 °C…+85 °C) Ii 0 µH 250 mA 250 mA 300 mA Input power, max. Pi Failure probability λges 3W 43 MTTF 2655 years ATEX Approval: T II 1 G EX ia IIC T4…T6 Ga T II 1 D Ex ia IIIC T135°C…T85°C Da EU-type examination certificate No.: KEMA 10ATEX0148 X 45 Note < 4 nF VARITECTOR SPC VSPC 4SL EX Arresters / plugs Bases and arresters should be ordered separately Arrester / plug Arrester / Plug VSPC 4SL 12 V DC EX Technical data Rated voltage UN Max. continuous voltage UC (AC) / (DC) Input voltage, max. Ui Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage Up wire-wire / wire-PE / GND-PE Base / socket VSPC 4SL 12 V AC EX VSPC 4SL 24 V DC EX VSPC 4SL 24 V AC EX 12 V DC 12 V AC / 16 V DC 24 V DC 24 V AC / 34 V DC 15 V DC 14 V 750 KHz 13.2 V AC / 18 V DC 19 V 750 KHz 28 V DC 26 V 750 KHz 28 V AC / 39 V DC 38 V 750 KHz 20 ms < 35 V 45 V / 20 V / 450 V 20 ms < 50 V 55 V / 50 V / 50 V 30 ms < 60 V 80 V / 60 V / 60 V 40 ms < 60 V 80 V / 60 V / 60 V < 45 V < 45 V < 55 V < 55 V < 80 V < 80 V < 110 V < 80 V < 25 V < 50 V 300 mA < 30 V < 50 V 300 mA < 40 V < 60 V 300 mA < 60 V < 60 V 300 mA IEC 61643-21, IEC 62305, EN 60079-0.2009, EN 6007911:2007, EN 60079-26:2007, EN 61241-11:2009 IEC 61643-21, IEC 62305, EN 60079-0.2009, EN 6007911:2007, EN 60079-26:2007, EN 61241-11:2009 IEC 61643-21, IEC 62305, EN 60079-0.2009, EN 6007911:2007, EN 60079-26:2007, EN 61241-11:2009 IEC 61643-21, IEC 62305, EN 60079-0.2009, EN 6007911:2007, EN 60079-26:2007, EN 61241-11:2009 VSPC 4SL 12VDC 0.5A ATEX VSPC 4SL 12VAC 0.5A ATEX VSPC 4SL 24VDC 0.5A ATEX VSPC 4SL 24VAC 0.5A ATEX 1161170000 1161150000 1161190000 1161180000 1 1 1 1 VSPC BASE 4SL FG EX VSPC BASE 4SL FG EX VSPC BASE 4SL FG EX VSPC BASE 4SL FG EX 0.5 mm² / 4 mm² 0.5 mm² / 4 mm² 0.5 mm² / 4 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 7 mm 0.5...0.8 Nm 7 mm 0.5...0.8 Nm 7 mm 0.5...0.8 Nm 7 mm 0.5...0.8 Nm VSPC BASE 4SL FG EX VSPC BASE 4SL FG EX VSPC BASE 4SL FG EX VSPC BASE 4SL FG EX 8951840000 8951840000 8951840000 8951840000 1 1 1 1 Protection level on output side sym. Input 1 kV/µs, typ. Input 8/20 µs, typ. Protection level on output side unsym., Input 1 kV/µs, typ. Input 8/20 µs, typ. Nominal current Standards Note Ordering Data Arrester / plug Type Part No. Qty. Note Base / Socket Technical data Clamping range, Rated connection, min./max. Conductor cross section, flexible, min./max. solid, min./max. stranded, min./max. Stripping length Tightening torque Note Ordering Data Base / socket Indirect earthing via gas dischargedType tube FG, floating ground Part No. Qty. Size of complete module (arrester + base) Length x width x height Note: 90 x 17.8 x 69 mm 90 x 17.8 x 69 mm 90 x 17.8 x 69 mm 90 x 17.8 x 69 mm Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 46 VARITECTOR SPC VSPC 3/4 WIRE EX – 3/4 wire measurements in intrinsically safe circuits • P luggable arrester (impedance neutral plugging/ unplugging without interruption) • Protection for measuring bridge signals • Can be tested with the V-TEST testing device • Can be used to comply with the IEC 62305 installation standard • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Can be used in zone 2, 1 and 0 • Certified for IEC 61643-21:08 D1, C1, C2, C3 Technical Data Arresters / Plugs General data Input voltage,max. Ui 6V Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Surge strength C1 Surge strength C2 Surge strength C3 Surge strength D1 0.2 Ω Mode 2 C1; C2; C3; D1 < 1 kA / 8/20 µs 5 kA / 8/20 µs 100 A / 10/1000 µs 2.5 kA 10/350 µs Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp. (10/350 µs) wire-wire / wire-PE / GND-PE Type of connection Storage temperature Ambient temperature (operational) Rel. humidity Degree of protection 2.5 kA / 2.5 kA / 2.5 kA 10 kA / 10 kA / 10 kA 2.5 kA / 2.5 kA / 2.5 kA Pluggable in VSPC BASE -40 °C…+80 °C -40 °C...+70 °C 5 %...96 % RH IP20 Flammability class EX protection data Inner capacitance, max. Ci V0 Inner inductance, max. Li Temperature class T6/85 °C ( -40 °C…+60 °C) Ii Temperature class T5/100 °C ( -40 °C…+75 °C) Ii Temperature class T4/135 °C ( -40 °C…+85 °C) Ii 0 µH 250 mA 250 mA 300 mA Input power, max. Pi Failure probability λges 3W 43 MTTF 2655 years ATEX Approval: T II 1 G EX ia IIC T4…T6 Ga T II 1 D Ex ia IIIC T135°C…T85°C Da EU-type examination certificate No.: KEMA 10ATEX0148 X 47 Note < 4 nF VARITECTOR SPC VSPC 3/4 WIRE EX Arresters / plugs Bases and arresters should be ordered separately Arrester / plug Arrester / Plug Base / socket VSPC 3/4WIRE 5 V DC EX Technical data 3 V DC Rated voltage (DC) Max. continuous voltage Uc (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage Up wire-wire / wire-PE / GND-PE 6.4 V DC 730 KHz 20 ms < 800 V 35 V / 800 V / 500 V Protection level on output side sym. Input 1 kV/µs, typ. Input 8/20 µs, typ. < 35 V < 35 V Protection level on output side unsym., Input 1 kV/µs, typ. Input 8/20 µs, typ. < 250 V < 800 V IEC 61643-21, IEC 62305, EN 60079-0.2009, EN 60079-11:2007, EN 60079-26:2007, EN 61241-11:2009 Standards Note Ordering Data Arrester / plug Type Part No. Qty. Note VSPC 3/4WIRE 5VDC ATEX 8953650000 1 VSPC BASE 4SL FG EX Base / Socket Technical data Clamping range, Rated connection, min./max. 0.5 mm² / 4 mm² Conductor cross section, flexible, min./max. solid, min./max. stranded, min./max. 0.5 mm² / 2.5 mm² 0.5 mm² / 4 mm² 0.5 mm² / 2.5 mm² 7 mm 0.5...0.8 Nm Stripping length Tightening torque Note Ordering Data Base / socket Indirect earthing via gas dischargedType tube FG, floating ground Part No. Qty. Size of complete module (arrester + base) Length x width x height Note: VSPC BASE 4SL FG EX 8951840000 1 90 x 17.8 x 69 mm Accessories: Screwdrivers SD 0.6x3.5x200 Part No.: 9010110000 48 VARITECTOR SSC VSSC 6AN CL and TR CL – Protection for analog signals (CL) with and without disconnect lever (TR) Two stage surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal block format • Modular width of just 6.2 mm • Space saving design: 1 analog signal • Torx® slotted screw connection • Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 standards • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current 500 mA (see derating curve) Dielectric strength at FG against PE Volume resistivity Overstressed fault mode Requirement category IEC 61643-21 Standards Surge strength C2 Surge strength C3 – 1.8 Ω ± 10 % Mode 2 C2; C3; D1 IEC 61643-21 2.5 kA 50 A Surge strength D1 Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE Storage temperature Ambient temperature (operational) Humidity Degree of protection 0.5 kA 2.5 kA / 2.5 kA / – 5 kA / 5 kA / – – / 0.5 kA / – -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. Stripping length 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² 10 mm Mounting rail Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 TS35 Dimensions Length x width x height Torx® T15 / slot 0.8 x 4 88.5 x 6.2 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 49 VARITECTOR SSC VSSC CL and TR CL Technical Data CL 12 V DC CL 24 V UC CL 48 V UC Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC 15 V DC ≤ 700 kHz ≤ 20 ms 30 V AC / 42 V DC ≤ 700 kHz ≤ 170 ms 60 V AC / 85 V DC ≤ 700 kHz ≤ 150 ms 75 V AC / 106 V DC ≤ 700 kHz ≤ 20 ms ≤ 1600 V 35 V / 900 V / - ≤ 1650 V 90 V / 900 V / - ≤ 1510 V 200 V / 770 V / - ≤ 1520 V 260 V / 780 V / - Protection level on output side sym., input 1 kV/µs, typ. 30 V 70 V 70 V 200 V Protection level on output side unsym., input 1 kV/µs, typ. 900 V 900 V 770 V 780 V VSSC6 CL 12Vdc 0.5A VSSC6 CL 24Vuc 0.5A 1064170000 VSSC6 CL 48Vuc 0.5A VSSC6 CL 60Vuc 0.5A 1064150000 1064190000 1064210000 10 pieces 10 pieces 10 pieces 10 pieces Technical Data TR CL 12 V DC TR CL 24 V UC TR CL 48 V UC TR CL 60 V UC Rated voltage AC/DC 12 V DC 24 V AC/ 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC 15 V DC ≤ 700 kHz ≤ 20 ms ≤ 1600 V 35 V / 900 V / - 30 V AC/ 42 V DC ≤ 700 kHz ≤ 170 ms ≤ 1650 V 90 V / 900 V / - 60 V AC / 85 V DC ≤ 700 kHz ≤ 150 ms ≤ 1510 V 200 V / 770 V / - 75 V AC / 106 V DC ≤ 700 kHz ≤ 20 ms ≤ 1520 V 260 V / 780 V / - Protection level on output side sym., input 1 kV/µs, typ. 30 V 70 V 150 V 200 V Protection level on output side unsym., input 1 kV/µs, typ. 900 V 900 V 770 V 780 V Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP wire-wire / wire-PE / GND-PE Ordering data Type Part No. Qty. CL 60 V UC Note Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP wire-wire / wire-PE / GND-PE Yes Disconnect lever Testing option Ordering data Type Part No. Qty. Yes Yes Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Functional screw with test plug receptacle connection 1, 2, 4, 5 Functional screw with test plug receptacle connection 1, 2, 4, 5 Functional screw with test plug receptacle connection 1, 2, 4, 5 VSSC6 TR CL 12Vdc 0.5A VSSC6 TR CL 24Vuc 0.5A VSSC6 TR CL 48Vuc 0.5A VSSC6 TR CL 60Vuc 0.5A 1064220000 1064230000 1064240000 1064250000 10 pieces 10 pieces 10 pieces 10 pieces Note 50 VARITECTOR SSC VSSC 6AN CLFG and TR CLFG – Protection for analog signals (CL) with floating ground (FG) with and without disconnect lever (TR) Two stage surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal-block format • Modular width of just 6.2 mm • Space saving design: 1 analog signal • Torx® slotted screw connection • Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 applications standards. • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Version with floating ground PE connection used to avoid differences in voltage potential Technical Data General data Nominal current 500 mA (see derating curve) Dielectric strength at FG against PE Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Standards Surge strength C2 Surge strength C3 ≥ 500 V 1.8 Ω ± 10 % Mode 2 C2; C3; D1 IEC 61643-21 2.5 kA 50 A Surge strength D1 Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE Storage temperature Ambient temperature (operational) Humidity Degree of protection 0.5 kA 2.5 kA / 2.5 kA / – 5 kA / 5 kA / – – / 0.5 kA / – -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. Stripping length 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² 10 mm Mounting rail Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 TS35 Dimensions Length x width x height Torx® screw T15 / slot 0.8 x 4 88.5 x 6.2 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 51 VARITECTOR SSC VSSC 6AN CLFG and TR CLFG Technical Data CLFG 12 V DC CLFG 24 V UC CLFG 48 V UC CLFG 60 V UC Rated voltage AC/DC 12 V DC 24 V AC/ 34 V DC 48 V AC / 68 V DC 15 V DC ≤ 700 kHz ≤ 20 ms 30 V AC / 42 V DC ≤ 700 kHz ≤ 20 ms 60 V AC / 85 V DC ≤ 700 kHz ≤ 20 ms 60 V AC / 85 V DC 75 V AC / 106 V DC ≤ 35 V 35 V / 1600 V / 800 V ≤ 85 V 90 V / 1632 V / 800 V ≤ 90 V 200 V / 1510 V / 800 V ≤ 700 kHz ≤ 20 ms ≤ 300 V 260 V / 1510 V / 800 V 30 V 70 V 150 V 200 V 1600 V 1632 V 1510 V 1510 V VSSC6 CLFG 12VDC 0.5A VSSC6 CL FG24VUC 0.5A VSSC6 CLFG 48VUC 0.5A VSSC6 CLFG 60VUC 0.5A 1064260000 1064270000 1064280000 1064290000 10 pieces 10 pieces 10 pieces 10 pieces Technical Data TR CLFG 12 V DC TR CLFG 24 V UC TR CLFG 48 V UC TR CLFG 60 V UC Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC 15 V DC ≤ 700 kHz ≤ 20 ms ≤ 35 V 35 V / 1600 V / 800 V 30 V AC / 42 V DC ≤ 700 kHz ≤ 20 ms ≤ 85 V 90 V / 1632 V / 800 V 60 V AC / 85 V dc ≤ 700 kHz ≤ 20 ms ≤ 90 V 200 V / 1510 V / 800 V 75 V AC / 106 V DC ≤ 700 kHz ≤ 20 ms ≤ 300 V 260 V / 1510 V / 800 V 30 V 70 V 150 V 200 V 1600 V 1632 V 1510 V 1510 V Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Protection level on output side unsym., Input 1 kV/µs, typ. Ordering data Type Part No. Qty. Note Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Protection level on output side unsym., Input 1 kV/µs, typ. Disconnect lever Testing option Ordering data Type Part No. Qty. Note yes yes yes Functional screw with test plug receptacle connection 1, 2, 4, 5 yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Functional screw with test plug receptacle connection 1, 2, 4, 5 Functional screw with test plug receptacle connection 1, 2, 4, 5 VSSC6 TR CLFG 12Vdc0.5 VSSC6TR CLFG 24VUC 0.5A VSSC6 TR CLFG 48VUC 0.5A VSSC6 TR CLFG 60VUC 0.5A 1064300000 1064310000 1064320000 1064330000 10 pieces 10 pieces 10 pieces 10 pieces 52 VARITECTOR SSC VSSC 6AN SL and TR SL – Protection for binary signals (SL) with and without disconnect lever (TR) and indicator (LD) Two-stage surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal-block format • Modular width of just 6.2 mm • Space saving design: 2 binary signals • Torx® slotted screw connection • Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 applications standards • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current 500 mA (see derating curve) Dielectric strength at FG against PE Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Standards Surge strength C2 Surge strength D1 – 1.8 Ω ± 10 % Mode 2 C2; C3; D1 IEC 61643-21 2.5 kA 1 kA Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE Storage temperature Ambient temperature (operational) Humidity Degree of protection – / 2.5 kA / – – / 10 kA / – – / 1 kA / – -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. Stripping length 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² 10 mm TS35 Mounting rail Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 Dimensions Length x width x height Torx® screw T15 / slot 0.8 x 4 88.5 x 6.1 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 53 VARITECTOR SSC VSSC 6AN SL and TR SL Technical Data SL LD 12 V DC SL LD 24 V UC Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC/ 68 V DC 60 V AC / 85 V DC 15 V DC ≤ 700 kHz ≤ 30 ms 30 V AC / 42 V DC ≤ 700 kHz ≤ 30 ms 60 V AC / 85 V DC ≤ 700 kHz ≤ 30 ms 75 V AC / 106 V DC ≤ 700 kHz ≤ 30 ms ≤ 40 V - / 74 V / - ≤ 100 V - / 110 V / - ≤ 220 V - / 175 V / - ≤ 330 V - / 230 V / - - - - - Protection level on output side unsym., Input 1 kV/µs, typ. 74 V 110 V 175 V 230 V Surge strength C3 10 A 50 A 50 A 50 A Status indicator Ordering data Type Yes Yes Yes Yes VSSC6 SL LD 12VDC 0.5A VSSC6 SL LD 24VUC 0.5A VSSC6 SL LD 48VUC 0.5A VSSC6 SL LD 60VUC 0.5A 1064340000 1064350000 10 pieces 10 pieces 10 pieces 10 pieces Technical Data TR SL LD 12 V DC TR SL LD 24 V UC TR SL LD 48 V UC TR SL LD 60 V UC Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC/ 68 V DC 60 V AC / 85 V DC 15 V DC ≤ 700 kHz ≤ 30 ms ≤ 40 V - / 74 V / - 30 V AC / 42 V DC ≤ 700 kHz ≤ 30 ms ≤ 100 V - / 110 V / - 60 V AC / 85 V DC ≤ 700 kHz ≤ 30 ms ≤ 220 V - / 175 V / - 75 V AC / 106 V DC ≤ 700 kHz ≤ 30 ms ≤ 330 V - / 230 V / - - - - - 74 V 110 V 175 V 230 V Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Part No. Qty. SL LD 4w8 V UC 1064360000 SL LD 60 V UC 1064370000 Note Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Protection level on output side unsym., Input 1 kV/µs, typ. Surge strength C3 Disconnect lever Testing option 10 A Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Status indicator Ordering data Type Part No. Qty. 50 A Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 50 A Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 50 A Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Yes Yes Yes Yes VSSC6 TR SL LD12Vdc0.5A VSSC6 TR SL LD 24VUC 0.5A VSSC6 TR SL LD 48VUC 0.5A VSSC6 TR SL LD 60VUC 0.5A 1064380000 1064390000 1064400000 1064410000 10 pieces 10 pieces 10 pieces 10 pieces Note 54 VARITECTOR SPC VSSC 6AN SLFG and TR SLFG – Protection for binary signals (SL) with floating ground (FG), with and without disconnect lever (TR) and indicator (LD) Two stage surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal block format • Modular width of just 6.2 mm • Space saving design: 2 binary signals • Torx® slotted screw connection • Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 applications standards • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Version with floating ground PE connection used to avoid differences in voltage potential Technical Data General data Dielectric strength at FG against PE ≥ 500 V Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Standards Surge strength C2 Surge strength C3 Surge strength D1 1.8 Ω ± 10 % Mode 2 C2; C3; D1 IEC 61643-21 2.5 kA 10 A; 50 A @ 60 V 1 kA Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE Storage temperature Ambient temperature (operational) Humidity Degree of protection – / 2.5 kA / 2.5 kA – / 10 kA / 10 kA – / 10 kA / – -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. Stripping length 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² 10 mm Mounting rail Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 TS35 Dimensions Length x width x height Torx® screw T15 / slot 0.8 x 4 88.5 x 6.2 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 55 VARITECTOR SSC VSSC 6AN SLFG and TR SLFG Technical Data SLFG LD 12 V DC SLFG LD 24 V UC SLFG LD 48 V UC Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC 15 V DC ≤ 700 kHz ≤ 20 ms 30 V AC / 42 V DC ≤ 700 kHz ≤ 20 ms 60 V AC / 85 V DC ≤ 700 kHz ≤ 20 ms 75 V AC / 106 V DC ≤ 700 kHz ≤ 20 ms ≤ 1600 V - / 74 V / 1400 V ≤ 1650 V - / 110 V / 1400 V ≤ 1550 V - / 175 V / 1200 V ≤ 1550 V - / 230 V / 1200 V 30 V 70 V 150 V 200 V Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP wire-wire / wire-PE / GND-PE SLFG LD 60 V UC Protection level on output side sym. Input 1 kV/µs, typ. Protection level on output side unsym., Input 1 kV/µs, typ. Nominal current Status indicator Ordering data Type Part No. Qty. 74 V 110 V 175 V 230 V 500 mA 200 mA (IEC 61643-21) on request on request yes yes yes yes VSSC6 SLFG 12VDC 0.5A VSSC6 SLFG 24VUC 0.5A VSSC6 SLFG 48VUC 0.5A VSSC6 SLFG 60VUC 0.5A 1064420000 1064430000 1064440000 1064470000 10 pieces 10 pieces 10 pieces 10 pieces Note Technical Data TR SLFG LD 12 V DC TR SLFG LD 24 V UC TR SLFG LD 48 V UC TR SLFG LD 60 V UC Rated voltage AC/DC Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP wire-wire / wire-PE / GND-PE 12 V DC 24 V AC / 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC 15 V DC ≤ 700 kHz ≤ 20 ms ≤ 1600 V - / 74 V / 1400 V 30 V AC / 42 V DC ≤ 700 kHz ≤ 20 ms ≤ 1650 V - / 110 V / 1400 V 60 V AC / 85 V DC ≤ 700 kHz ≤ 20 ms ≤ 1550 V - / 175 V / 1200 V 75 V AC / 106 V DC ≤ 700 kHz ≤ 20 ms ≤ 1550 V - / 230 V / 1200 V 30 V 70 V 150 V 200 V Protection level on output side sym. Input 1 kV/µs, typ. Protection level on output side unsym., Input 1 kV/µs, typ. Nominal current Disconnect lever Testing option Status indicator Ordering data Type Part No. Qty. 74 V 110 V 175 V 230 V 500 mA Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 200 mA (IEC 61643-21) Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 on request Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 on request Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Yes Yes Yes Yes VSSC6 TR SLFG LD 12VDC 0.5A VSSC6 TR SLFG LD 24VUC 0.5A VSSC6 TR SL FG LD 48VUC 0.5A VSSC6 TR SLFG LD 60VUC 0.5A 1064490000 10 pieces 1064500000 10 pieces 1064510000 10 pieces 1064520000 10 pieces Note 56 VARITECTOR SSC VSSC 6AN MOV and TR LD MOV 12 V DC and 24 V UC – with varistor, with and without disconnect lever (TR) and indicator (LD) Surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal block format • Modular width of just 6.2 mm • Space saving design: 2 analog signals • Torx® slotted screw connection • Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 applications standards • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Standards Surge strength C1 Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Storage temperature Ambient temperature (operational) Humidity Degree of protection 12 A (see derating curve) < 0.1 Ω Mode 1 C1 IEC 61643-21 (Pending) 0.25 kA – / 500 A / – – / 1 kA / – -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. Stripping length 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² 10 mm Mounting rail Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 TS35 Dimensions Length x width x height Torx® screw T15 / slot 0.8 x 4 88.5 x 6.2 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 57 VARITECTOR SSC VSSC MOV and TR LD MOV 12 V DC and 24 V UC Technical Data MOV 12 V DC MOV 24 V UC Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Residual voltage UP 15 V DC ≤ 100 kHz ≤ 50 V 30 V AC / 42 V DC ≤ 400 kHz ≤ 100 V wire-wire / wire-PE / GND-PE - / 57 V / - - / 120 V / - 50 V 150 V VSSC6 MOV 12VDC VSSC6 MOV 24VUC 1064530000 1064540000 10 pieces 10 pieces Technical Data TR LD MOV 12 V DC TR LD MOV 24 V UC Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 15 V DC ≤ 100 kHz ≤ 50 V - / 57 V / - 30 V AC / 42 V DC ≤ 400 kHz ≤ 100 V - / 120 V / - 50 V 150 V Protection level on output side sym. Input 1 kV/µs, typ. Ordering data Type Part No. Qty. Note Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Residual voltage UP wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Disconnect lever Testing option Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Status indicator Ordering data Type Part No. Qty. Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Yes Yes VSSC6 TR LD MOV 12VDC VSSC6 TR MOV 24VUC 1064800000 1064810000 10 pieces 10 pieces Note 58 VARITECTOR SSC VSSC 6AN MOV and TR LD MOV 48 V UC and 60 V UC – with varistor, with and without disconnect lever (TR) and indicator (LD) Surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal block format • Modular width of just 6.2 mm • Space saving design: 2 analog signals • Torx® slotted screw connection • Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 applications standards • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Standards Surge strength C1 Surge strength C2 Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Storage temperature Ambient temperature (operational) Humidity Degree of protection 12 A (see derating curve) < 0.1 Ω Mode 1 C1 acc. to IEC 61643-21 0.5 kA 1 kA – / 1 kA / – – / 4.5 kA / – -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. Stripping length 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² 10 mm Mounting rail Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 TS35 Dimensions Length x width x height Torx® screw T15 / slot 0.8 x 4 88.5 x 6.2 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 59 VARITECTOR SSC VSSC MOV and TR LD MOV 48 V UC and 60 V UC Technical Data MOV 48VUC Rated voltage AC/DC 48 V AC / 60 V DC 60 V AC / 85 V DC Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Residual voltage UP 60 V AC / 85 V DC ≤ 400 kHz ≤ 200 V 75 V AC / 106 V DC ≤ 600 kHz ≤ 250 V - / 213 V / - - / 269 V / - 200 V 250 V VSSC6 MOV 48VUC VSSC6 MOV 60VUC 1064570000 1064600000 10 pieces 10 pieces Technical Data TR LD MOV 48VUC TR LD MOV 60VUC Rated voltage AC/DC 48 V AC / 60 V DC 60 V AC / 85 V DC Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Residual voltage UP 60 V AC / 85 V DC ≤ 400 kHz ≤ 200 V - / 213 V / - 75 V AC / 106 V DC ≤ 600 kHz ≤ 250 V - /269 V / - 200 V 250 V wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Ordering data Type Part No. Qty. MOV 60VUC Note wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Disconnect lever Yes Testing option Status indicator Ordering data Type Part No. Qty. Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Functional screw with test plug receptacle connection 1, 2, 4, 5 VSSC6 TR LD MOV 48VUC VSSC6 TR LD MOV 60VUC 1064820000 1064830000 10 pieces 10 pieces Note 60 VARITECTOR SSC VSSC 6AN MOV and TR LD MOV 120 V UC, 150 V UC and 240 V UC – with varistor, with and without disconnect lever (TR) and indicator (LD) Surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal block format • Modular width of just 6.2 mm • Space saving design: 2 analog signals • Torx® slotted screw connection • Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 applications standards • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Standards Surge strength C1 Surge strength C2 Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Storage temperature Ambient temperature (operational) Humidity Degree of protection 12 A (see derating curve) < 0.1 Ω Mode 1 C1. C2 IEC 61643-21 (Pending) 0.5 kA 1.5 kA – / 500 A / – – / 1.5 kA / – -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. Stripping length 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² 10 mm Mounting rail Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 TS35 Dimensions Length x width x height Torx® screw T15 / slot 0.8 x 4 88.5 x 12.4 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 61 VARITECTOR SSC VSSC MOV and TR LD MOV 120 V UC, 150 V UC and 240 V UC Technical Data MOV 120VUC MOV 150VUC MOV 240VUC Rated voltage AC/DC 120 V AC / 170 V DC 150 V AC / 212 V DC 240 V AC / 339 V DC Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Residual voltage UP 150 V AC / 212 V DC ≤ 1 MHz ≤ 500 V 188 V AC / 266 V DC ≤ 1 MHz ≤ 600 V 288 V AC / 407 V DC ≤ 1.7 MHz ≤ 900 V - / 543 V / - - / 641 V / - - / 1022 V / - 500 V 600 V 1000 V VSSC6 MOV 120VUC VSSC6 MOV 150VUC VSSC6 MOV 240VUC 1064610000 1064620000 1064630000 10 pieces 10 pieces 10 pieces Technical Data TR LD MOV 120VUC TR LD MOV 150VUC TR LD MOV 240VUC Rated voltage AC/DC 120 V AC / 170 V DC 150 V AC / 212 V DC 240 V AC / 339 V DC Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Residual voltage UP 150 V AC / 212 V DC ≤ 1 MHz ≤ 500 V - / 543 V / - 188 V AC / 266 V DC ≤ 1 MHz ≤ 600 V - / 641 V / - 288 V AC / 407 V DC ≤ 1.7 MHz ≤ 900 V - / 1022 V / - 500 V 600 V 1000 V Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Yes Yes Yes VSSC6 TR LD MOV 120VUC VSSC6 TR LD MOV 150VUC VSSC6 TR LD MOV 240VUC wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Ordering data Type Part No. Qty. Note wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Disconnect lever Testing option Status indicator Ordering data Type Part No. Qty. 1064840000 10 pieces 1064850000 10 pieces 1064860000 10 pieces Note 62 VARITECTOR SSC VSSC 6AN TAZ and TR TAZ – with suppressor diode gap, with and without disconnect lever (TR) and indication (LD) Surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal block format • Modular width of just 6.2 mm • Space saving design: 2 analog signals • Torx® slotted screw connection • Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 applications standards • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current 12 A (see derating curve) Volume resistivity Overstressed fault mode Storage temperature Ambient temperature (operational) Humidity Degree of protection < 0.1 Ω Mode 1 -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. Stripping length 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² 10 mm Mounting rail Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 TS35 Dimensions Length x width x height Torx® screw T15 / slot 0.8 x 4 88.5 x 6.2 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 63 VARITECTOR SSC VSSC TAZ and TR LD TAZ Technical Data TAZ 12VDC TAZ 24VUC Rated voltage AC/DC 12 V DC 24 V UC / 34 V DC Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP 15 V DC ≤ 1 MHz ≤ 30 ms 30 V AC / 42 V DC ≤ 1 MHz ≤ 30 ms ≤ 22 V - / 26 V / - ≤ 61 V - / 62 V / - Protection level on output side sym. Input 1 kV/µs, typ. 30 V 70 V Requirement category to IEC 61643-21 Surge strength C3 Rated discharge current IN (8/20 μs) wire-PE Rated discharge current Imax (8/20 μs) wire-PE C3 50 A 200 A 500 A C3 15 A 100 A 200 A Standards Ordering data Type IEC 61643-21 IEC 61643-21 VSSC6 TAZ 12VDC VSSC6 TAZ 24VUC 1064730000 1064740000 10 pieces 10 pieces Technical Data TR LD TAZ 12VDC TR LD TAZ 24VUC Rated voltage AC/DC 12 V DC 24 V UC / 34 V DC 15 V DC ≤ 1 MHz ≤ 30 ms ≤ 22 V - / 26 V / - 30 V AC / 42 V DC ≤ 1 MHz ≤ 30 ms ≤ 61 V - / 62 V / - 30 V 70 V C3 50 A 200 A 500 A IEC 61643-21 Yes C3 15 A 100 A 200 A IEC 61643-21 Yes Functional screw with test plug receptacle connection 1, 2, 4, 5 Functional screw with test plug receptacle connection 1, 2, 4, 5 VSSC6 TR LD TAZ 12VDC VSSC6 TR LD TAZ 24VUC 1064940000 1064950000 10 pieces 10 pieces wire-wire / wire-PE / GND-PE Part No. Qty. Note Max. continuous voltage UC (AC) / (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. Requirement category to IEC 61643-21 Surge strength C3 Rated discharge current IN (8/20 μs) wire-PE Rated discharge current Imax (8/20 μs) wire-PE Standards Disconnect lever Testing option Ordering data Type Part No. Qty. Note 64 VARITECTOR SSC VSSC 6AN RS485, RS485 DP and RS232 – for interface signals Two-stage surge protection with screw connection for instrumentation, control and automation technology • • • • • Surge protection in terminal block format Modular width of just 6.2 mm Space saving design Torx® slotted screw connection Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 applications standards • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current 500 mA (see derating curve) Volume resistivity Overstressed fault mode Requirement category to IEC 61643-21 Standards Surge strength C2 Surge strength C3 Surge strength D1 1.8 Ω ±10 % Mode 2 C2, C3, D1 IEC 61643-21 2.5 kA 10 A 0.5 kA Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE Storage temperature Ambient temperature (operational) Humidity Degree of protection 2.5 kA / 2.5 kA / – 10 kA / 10 kA / – 1 kA -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² Stripping length Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 10 mm Dimensions Length x width x height Torx® screw T15 / slot 0.8 x 4 88.5 x 6.2 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 65 VARITECTOR SSC VSSC 6AN RS485, RS485 DP and RS232 Technical Data RS485 RS485 DP RS232 Rated voltage AC/DC 12 V DC 12 V DC 12 V DC Max. continuous voltage UC (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP 15 V DC ≤ 2 MHz ≤ 20 ms 15 V DC ≤ 2 MHz ≤ 20 ms 15 V DC ≤ 2 MHz ≤ 20 ms ≤ 94 V 35 V / 35 V / - ≤ 94 V 35 V / 35 V / - ≤ 80 V 70 V / 35 V / - Protection level on output side sym. Input 1 kV/µs, typ. 30 V 30 V 60 V Protection level on output side unsym., Input 1 kV/µs, typ. 94 V VSSC6 RS485 VSSC6 RS485 DP VSSC6 RS232 1064980000 1065010000 1064990000 10 pieces 10 pieces 10 pieces wire-wire / wire-PE / GND-PE Ordering data Type Part No. Qty. Note 66 VARITECTOR SSC VSSC 6AN RTD – for temperature signals Two-stage surge protection with screw connection for instrumentation, control and automation technology • • • • • Surge protection in terminal block format Modular width of just 6.2 mm Space saving design Torx® slotted screw connection Can be used to comply with the IEC 62305 installation standard and the IEC 61643-1/-22 applications standards • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current 300 mA Dielectric strength at FG against PE Volume resistivity Overstressed fault mode Requirement category acc. to IEC 61643-21 Standards Surge strength C2 Surge strength C3 – 1.8 Ω ±10 % Mode 2 C2, C3, D1 IEC 61643-21 2.5 kA 8/20 µs, 5 kV 1,2/50 µs 10 A 10/1000 µs Surge strength D1 Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE Storage temperature Ambient temperature (operational) Humidity Degree of protection 0.5 kA 10/350 µs 2.5 kA / 2.5 kA / – 10 kA / 10 kA / – 1 kA -40 °C...+80 °C -40 °C...+70 °C 5...96 % RH IP20 Flammability class Connection data Connection V0 Tightening torque Conductor cross section, flexible, ferrule (DIN 46228-1), max. Conductor cross section, flexible, ferrule (DIN 46228-1), min. Conductor cross section, solid, max. Conductor cross section, solid, min. Conductor cross section, stranded, Rated connection, max. Conductor cross section, stranded, Rated connection, min. Stripping length 0.5 Nm 4 mm² 0.5 mm² 6 mm² 0.5 mm² 4 mm² 0.5 mm² 10 mm Mounting rail Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 TS35 Dimensions Length x width x height Torx® screw T15 / slot 0.8 x 4 88.5 x 6.2 x 81 mm Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000; marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000 67 VARITECTOR SSC VSSC 6AN RTD Technical Data RTD Rated voltage AC/DC 1 V DC Max. continuous voltage UC (DC) Signal transmission properties (-3 dB) Pulse reset capacity Residual voltage UP 5 V DC ≤ 1 MHz ≤ 20 ms ≤ 126 V 15 V / 15 V / - wire-wire / wire-PE / GND-PE Protection level on output side sym. Input 1 kV/µs, typ. 10 V Protection level on output side unsym., Input 1 kV/µs, typ. 10 V Ordering data Type VSSC6 RTD Part No. 1139710000 Qty. 10 pieces Note 68 VARITECTOR SSC VARITECTOR SSC CL and CL FG Two-stage surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal-block format • Modular width of just 6.2 mm • Space-saving design: 1 analog signal • Torx slotted screw connection • Version with non-earthed PE connection for avoiding potential differences • U sable in accordance with installations standard IEC 62305 • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current IN at 25 °C Rated discharge current IN (8 / 20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8 / 20 µs) wire-wire / wire-PE / GND-PE Response time wire-wire / wire-PE / GND-PE Volume resistivity per path Discharge current Itotal Rated discharge current Iimp (10 / 350 µs) Surge strength Max. continuous voltage Overstressed fault mode Requirement category acc. to IEC 61643-21 Rel. humidity Degree of protection Ambient temperature (operational) Storage temperature Approvals Clampable conductor Connection UL, CSA pending Stripping length Tightening torque range Solid / stranded 7 mm 0.5 … 0.8 Nm 0.5 … 6 mm² / 0.5 … 4 mm² Flexible / flexible with ferrule Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 0.5 … 2.5 mm² Dimensions Length x width x height Note: end plate AP VSSC4: 1063120000 Applications 69 500 mA 2.5 kA / 2.5 kA / 5 kA / 5 kA / ≤ 1 ns / ≤ 100 ns / 1.8 Ω ± 10% 10 kA 1 kA 4 kV / 2 kA, 10 repetitions 1 A / 1 s, 5 repetitions Mode 2 C1; C2; C3; D1 5%…96% RH IP20 -40 °C…+70 °C -40 °C…+80 °C Torx screw (T15) / slot (0.8 x 4.0) 76 x 6.2 x 58.5 mm VARITECTOR SSC VARITECTOR SSC CL and CL FG Ordering Data VSSC4 CL 12 V DC 0.5 A VSSC4 CL FG 12 V DC 0.5 A VSSC4 CL 24 V UC 0.5 A Rated voltage UN 12 V DC 12 V DC 24 V AC / 34 V DC Max. continuous voltage UC Voltage GND-PE Capacitance Gas discharge tube Supressor diode Limiting frequency (-3 dB) at load resistance 15 V DC 4 nF 15 V DC > 500 V 4 nF 30 V AC / 42 V DC 650 pF 90 V 16 V 250 kHz 90 V 16 V 250 kHz 90 V 43V 1.5 MHz 35 V / 600 V / 30 V / 600 V / - 35 V / 1500 V / 30 V / 1500 V / - 90 V / 600 V / 70 V / 600 V / - VSSC4 CL 12VDC 0.5A VSSC4 CL FG 12VDC 0.5A VSSC4 CL 24VUC 0.5A 1063720000 1063760000 1063730000 10 piece 10 piece 10 piece VSSC4 CL FG 24 V UC 0.5 A VSSC4 CL 48 V UC 0.5 A VSSC4 CL FG 48 V UC 0.5 A Rated voltage UN 24 V AC / 34 V DC 48 V AC / 68 V DC 48 V AC / 68 V DC Max. continuous voltage UC Voltage GND-PE Capacitance Gas discharge tube Supressor diode Limiting frequency (-3 dB) at load resistance 30 V AC / 42 V DC > 500 V 650 pF 90 V 43V 1.5 MHz 60 V AC / 85 V DC 450 pF 150 V 91 V 2.2 MHz 60 V AC / 85 V DC > 500 V 450 pF 150 V 91 V 2.2 MHz 90 V / 1500 V / 70 V / 1500 V / - 200 V / 600 V / 150 V / 600 V / - 200 V / 1500 V / 150 V / 1500 V / - VSSC4 CL FG 24VUC 0.5A VSSC4 CL 48VUC 0.5A VSSC4 CL FG 48VUC 0.5A 1063770000 1063740000 1063780000 10 piece 10 piece 10 piece VSSC4 CL 60 V UC 0.5 A VSSC4 CL FG 60 V UC 0.5 A Protection level at IN wire-wire / wire-PE / GND-PE 1 kV / µs wire-wire / wire-PE / GND-PE Ordering data Type Part No. Qty. Note Ordering Data Protection level at IN wire-wire / wire-PE / GND-PE 1 kV / µs wire-wire / wire-PE / GND-PE Ordering data Type Part No. Qty. Note Ordering Data Rated voltage UN 60 V AC / 85 V DC 60 V AC / 85 V DC Max. continuous voltage UC Voltage GND-PE Capacitance Gas discharge tube Supressor diode Limiting frequency (-3 dB) at load resistance 75 V AC / 106 V DC 350 pF 230 V 120 V 2.8 MHz 75 V AC / 106 V DC > 500 V 350 pF 150 V 120 V 2.8 MHz 260 V / 600 V / 200 V / 600 V / - 260 V / 1500 V / 200 V / 1500 V / - VSSC4 CL 60VUC 0.5A VSSC4 CL FG 60VUC 0.5A 1063750000 1063790000 10 piece 10 piece Protection level at IN wire-wire / wire-PE / GND-PE 1 kV / µs wire-wire / wire-PE / GND-PE Ordering data Type Part No. Qty. Note 70 VARITECTOR SSC VARITECTOR SSC SL and SL FG Two-stage surge protection with screw connection for instrumentation, control and automation technology • Surge protection in terminal-block format • Modular width of just 6.2 mm • Space-saving design: 1 binary signal • Torx slotted screw connection • Version with non-earthed PE connection for avoiding potential differences • U sable in accordance with installations standard IEC 62305 • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Technical Data General data Nominal current IN at 25 °C Rated discharge current IN (8 / 20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8 / 20 µs) wire-wire / wire-PE / GND-PE Response time wire-wire / wire-PE / GND-PE Volume resistivity per path Discharge current Itotal Rated discharge current Iimp (10 / 350 µs) Surge strength Max. continuous voltage Overstressed fault mode Requirement category acc. to IEC 61643-21 Rel. humidity Degree of protection Ambient temperature (operational) Storage temperature Approvals Clampable conductor Connection UL, CSA pending Stripping length Tightening torque range Solid / stranded 7 mm 0.5 … 0.8 Nm 0.5 … 6 mm² / 0.5 … 4 mm² Flexible / flexible with ferrule Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 0.5 … 2.5 mm² Dimensions Length x width x height Note: end plate AP VSSC4: 1063120000 Applications 71 500 mA - / 2.5 kA / - / 10 kA / - / ≤ 2 ns / ≤ 100 ns 1.8 Ω ± 10% 10 kA 1 kA 4 kV / 2 kA, 10 repetitions 1 A / 1 s, 5 repetitions Mode 2 C1; C2; C3; D1 5%…96% RH IP20 -40 °C…+70 °C -40 °C…+80 °C Torx screw (T15) / slot (0.8 x 4.0) 76 x 6.2 x 58.5 mm VARITECTOR SSC VARITECTOR SSC SL and SL FG Ordering Data VSSC4 SL 12 V DC 0.5 A VSSC4 SL FG 12 V DC 0.5 A VSSC4 SL 24 V UC 0.5 A Rated voltage UN 12 V DC 12 V DC 24 V AC / 34 V DC Max. continuous voltage UC Voltage GND-PE Capacitance Gas discharge tube Supressor diode Limiting frequency (-3 dB) at load resistance 15 V DC 4 nF 15 V DC > 500 V 4 nF 30 V AC / 42 V DC 650 pF 90 V 16 V 250 KHz 90 V 16 V 250 KHz 90 V 43 V 1.5 MHz - / 35 V / - / 30 V / - - / 35 V / 1400 V - / 30 V / 1400 V - / 90 V / - / 70 V / - VSSC4 SL 12VDC 0.5A VSSC4 SL FG 12VDC 0.5A VSSC4 SL 24VUC 0.5A 1063830000 1063880000 1063840000 10 piece 10 piece 10 piece VSSC4 SL FG 24 V UC 0.5 A VSSC4 SL 48 V UC 0.5 A VSSC4 SL FG 48 V UC 0.5 A Rated voltage UN 24 V AC / 34 V DC 48 V AC / 68 V DC 48 V AC / 68 V DC Max. continuous voltage UC Voltage GND-PE Capacitance Gas discharge tube Supressor diode Limiting frequency (-3 dB) at load resistance 30 V AC / 42 V DC > 500 V 650 pF 90 V 43 V 1.5 MHz 60 V AC / 85 V DC 450 pF 150 V 91 V 2.2 MHz 60 V AC / 85 V DC > 500 V 450 pF 150 V 91 V 2.2 MHz - / 90 V / 1400 V - / 70 V / 1400 V - / 200 V / - / 150 V / - - / 200 V / 1200 V - / 150 V / 1200 V VSSC4 SL FG 24VUC 0.5A VSSC4 SL 48VUC 0.5A VSSC4 SL FG 48VUC 0.5A 1063890000 1063860000 1063910000 10 piece 10 piece 10 piece VSSC4 SL 60 V UC 0.5 A VSSC4 SL FG 60 V UC 0.5 A Protection level at IN wire-wire / wire-PE / GND-PE 1 kV / µs wire-wire / wire-PE / GND-PE Ordering data Type Part No. Qty. Note Ordering Data Protection level at IN wire-wire / wire-PE / GND-PE 1 kV / µs wire-wire / wire-PE / GND-PE Ordering data Type Part No. Qty. Note Ordering Data Rated voltage UN 60 V AC / 85 V DC 60 V AC / 85 V DC Max. continuous voltage UC Voltage GND-PE Capacitance Gas discharge tube Supressor diode Limiting frequency (-3 dB) at load resistance 75 V AC / 106 V DC 350 pF 230 V 120 V 2.8 MHz 75 V AC / 106 V DC > 500 V 350 pF 150 V 120 V 2.8 MHz - / 260 V / - / 200 V / - - / 260 V / 1200 V - / 200 V / 1200 V VSSC4 SL 60VUC 0.5A VSSC4 SL FG 60VUC 0.5A 1063870000 1063920000 10 piece 10 piece Protection level at IN wire-wire / wire-PE / GND-PE 1 kV / µs wire-wire / wire-PE / GND-PE Ordering data Type Part No. Qty. Note 72 VARITECTOR SSC VSSC4 MOV – Components Two-stage surge protection with screw connection for instrumentation, control and automation technology • Modular width of just 6.2 mm or 12.4 mm • Components built-into terminal block, such as GDT, MOV, TAZ • Torx slotted screw connection • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Accessories: end plate and extension frame Technical Data General data Nominal current IN at 25 °C Response time wire-wire / wire-PE / GND-PE Volume resistivity per path Surge strength Max. continuous voltage Combined pulse UOC Overstressed fault mode Requirement category acc. to IEC 61643-21 Rel. humidity Degree of protection Ambient temperature (operational) Storage temperature 73 - / 25 ns / < 0.1 Ω 1 kV / 100 A (10 / 1000 µs), 30 repetitions 0.25 A / 1 s, 5 repetitions 5 kV Mode 1 C1; C2; C3 5%…96% RH IP20 -40 °C…+70 °C -40 °C…+80 °C Approvals Clampable conductor Connection UL, CSA pending Stripping length Tightening torque range Solid / stranded 7 mm 0.5 … 0.8 Nm 0.5 … 6 mm² / 0.5 … 4 mm² Flexible / flexible with ferrule Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 0.5 … 2.5 mm² Note: end plate AP VSSC4: 1063120000 Applications 20 A Torx screw (T15) / slot (0.8 x 4.0) VARITECTOR SSC VSSC4 MOV – Components Ordering Data VSSC4 MOV 12 V DC VSSC4 MOV 24 V UC VSSC4 MOV 48 V UC Rated voltage UN 12 V DC 24 V AC / 34 V DC 48 V AC / 68 V DC 60 V AC / 85 V DC Max. continuous voltage UC Voltage GND-PE Capacitance Varistor Limiting frequency (-3 dB) at load resistance Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) 15 V DC 12 nF 30 V AC / 42 V DC 5 nF 60 V AC / 85 V DC 1650 pF 75 V AC / 106 V DC 1370 pF 18 V 80 kHz 47 V 200 kHz 100 V 600 kHz 120 V 700 kHz - / 500 A / - - / 500 A / - - / 2 kA / - - / 2 kA / - wire-wire / wire-PE / GND-PE Discharge current Itotal - / 1 kA / 1 kA - / 1 kA / 1 kA - / 4,5 kA / 4,5 kA - / 4,5 kA / 4,5 kA Protection level at IN wire-wire / wire-PE / GND-PE 1 kV / µs wire-wire / wire-PE / GND-PE - / 65 V / - / 50 V / - - / 180 V / - / 150 V / - - / 270 V / - / 200 V / - - / 320 V / - / 250 V / - 76 x 6.2 x 58.5 mm 76 x 6.2 x 58.5 mm 76 x 6.2 x 58.5 mm 76 x 6.2 x 58.5 mm VSSC4 MOV 12VDC VSSC4 MOV 24VUC VSSC4 MOV 48VUC VSSC4 MOV 60VUC 1063950000 1063960000 1063970000 1063980000 10 piece 10 piece 10 piece 10 piece VSSC4 MOV 120 V UC VSSC4 MOV 150 V UC VSSC4 MOV 240 V UC Rated voltage UN 120 V AC / 170 V DC 150 V AC / 212 V DC 120 V AC / 170 V DC Max. continuous voltage UC Voltage GND-PE Capacitance Varistor Limiting frequency (-3 dB) at load resistance Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE Discharge current Itotal 150 V AC / 212 V DC 2 nF 240 V 500 kHz 188 V AC / 266 V DC 1.5 nF 300 V 650 kHz 150 V AC / 212 V DC 2 nF 240 V 500 kHz - / 7.5 kA / - - / 7.5 kA / - - / 7,5 kA / - - / 15 kA / 15 kA - / 15 kA / 15 kA - / 15 kA / 15 kA - / 720 V / - / 500 V / - - / 900 V / - / 600 V / - - / 720 V / - / 500 V / - 76 x 12.4 x 58.5 mm 76 x 12.4 x 58.5 mm 76 x 12.4 x 58.5 mm VSSC4 MOV 120VUC VSSC4 MOV 150VUC VSSC4 MOV 240VUC 1063990000 1064010000 1064020000 10 piece 10 piece 10 piece Dimensions Length x width x height Ordering data Type Part No. Qty. VSSC4 MOV 60 V UC Note Ordering Data Protection level at IN wire-wire / wire-PE / GND-PE 1 kV / µs wire-wire / wire-PE / GND-PE Dimensions Length x width x height Ordering data Type Part No. Qty. Note 74 VARITECTOR SSC VSSC4 TAZ – Components Single stage surge protection with screw connection for instrumentation, control and automation technology • Modular width of just 6.2 mm or 12.4 mm • Components built-into terminal block, such as GDT, MOV, TAZ • Torx slotted screw connection • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Accessories: end plate and extension frame VSSC4 TAZ Technical Data General data Nominal current IN at 25 °C 20 A Volume resistivity per path Overstressed fault mode Rel. humidity Degree of protection Ambient temperature (operational) Storage temperature < 0.1 Ω Mode 2 5%…96% RH IP20 -40 °C…+70 °C -40 °C…+80 °C Approvals Clampable conductor Connection UL, CSA Stripping length Tightening torque range Solid / stranded 7 mm 0.5 … 0.8 Nm 0.5 … 6 mm² / 0.5 … 4 mm² Flexible / flexible with ferrule Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 0.5 … 2.5 mm² Note: end plate AP VSSC4: 1063120000 Applications 75 Torx screw (T15) / slot (0.8 x 4.0) VARITECTOR SSC VSSC4 TAZ – Components Ordering Data VSSC4 TAZ 24 V UC VSSC4 TAZ 48 V UC 24 V AC / 34 V DC 48 V AC / 75 V DC 30 V AC / 42 V DC 0.1 A / 1 s, 5 repetitions 10 A (10 / 1000 µs), 300 repetitions 60 V AC / 85 V DC 0.1 A / 1 s, 5 repetitions 5 A (10 / 1000 µs), 300 repetitions 650 pF C1; C2; C3 450 pF C1; C2; C3 51 V 1.5 MHz 100 V 2.2 MHz - / 100 A / - - / 50 A / - - / 200 A / 200 A - / 100 A / 100 A Protection level at IN wire-wire / wire-PE / GND-PE 1 kV / µs wire-wire / wire-PE / GND-PE - / 90 V / - / 70 V / - - / 200 V / - / 150 V / - Response time wire-wire / wire-PE / GND-PE - / 2 ns / - - / 2 ns / - Rated discharge current Iimp (10/350 µs) Dimensions Length x width x height Ordering data Type 76 x 6.2 x 58.5 mm 76 x 6.2 x 58.5 mm VSSC4 TAZ 24VUC VSSC4 TAZ 48VUC 1064080000 1064090000 10 piece 10 piece Rated voltage UN Max. continuous voltage UC Alternating-current strength Surge strength Capacitance Requirement category acc. to IEC 61643-21 Gas discharge tube Supressordiode Limiting frequency (-3 dB) at load resistance Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE Discharge current Itotal Part No. Qty. Note 76 VARITECTOR SSC VSSC4 RC – Components Two-stage surge protection with screw connection for instrumentation, control and automation technology • Modular width of 12.4 mm • Torx slotted screw connection • Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE • Accessories: end plate and extension frame Technical Data General data Nominal current IN at 25 °C 20 A Response time wire-wire / wire-PE / GND-PE Volume resistivity per path Surge strength Max. continuous voltage Overstressed fault mode Requirement category acc. to IEC 61643-21 Capacitance Limiting frequency (-3 dB) at load resistance Rel. humidity Degree of protection Ambient temperature (operational) Storage temperature - / 25 ns / < 0.1 Ω 1 kV / 100A (10 / 1000 µs), 30 repetitions 0.25 A / 1 s, 5 repetitions Mode 1 C1 220 nF 4 kHz 5%…96% RH IP20 -40 °C…+70 °C -40 °C…+80 °C Approvals Clampable conductor Connection UL, CSA Stripping length Tightening torque range Solid / stranded 7 mm 0.5 … 0.8 Nm 0.5 … 6 mm² / 0.5 … 4 mm² Flexible / flexible with ferrule Approvals UL Listed (USL). Assessed to UL497B. File ref. E 311081 0.5 … 2.5 mm² Dimensions Length x width x height Note: end plate AP VSSC4: 1063120000 Applications 77 Torx screw (T15) / slot (0.8 x 4.0) 76 x 12.4 x 58.5 mm VARITECTOR SSC VSSC4 RC – Components Ordering Data VSSC4 RC 24 V UC Rated voltage UN Max. continuous voltage UC Voltage GND-PE Alternating-current strength Varistor Surge strength C1 Protection level Up Rated discharge current IN (8/20 µs) wire-wire / wire-PE / GND-PE Rated discharge current Imax (8/20 µs) wire-wire / wire-PE / GND-PE VSSC4 RC 240 V UC 24 V AC 240 V AC 30 V AC / 42 V DC 0.25 A / 1 s, 30 repetitions 275 V AC / 388 V DC 0.1 A / 1 s, 5 repetitions 43 V 0.25 kA / 8/20 μs 0.5 kV / 1.2/50 μs < 500 V 430 V 0.25 kA / 8/20 μs 0.5 kV / 1.2/50 μs < 500 V - / 500 A / - - / 1 kA / - - / 1 kA / - - / 2.5 kA / - Discharge current Itotal IN wire-wire / wire-PE / GND-PE 1 kA - / 150 V / - 2.5 kA - / 1500 V / - Protection level at 1 kV / µs wire-wire / wire-PE / GND-PE - / 120 V / - - / 500 V / - VSSC4 RC 24VUC VSSC4 RC 240VUC 1064120000 1064130000 5 piece 5 piece Ordering data Type Part No. Qty. Note Subject to technical changes • 03/12 - LIT1119E 78