Switch-mode power supplies connectPower INSTAPOWER connectPower single-phase CP SNT 24 W 28 V 1 A CP SNT 24 W 24 V 1 A A L FUSE N + L − N FUSE + − Technical data Input Input voltage Input current Input frequency, max. making current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100 % load Max. capacitance at output Insulation coordination (EN 50 178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data Ambient temperature Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Length x width x height mm² mm Note 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 28 V DC 1A 28 W <2% Surge current / thermal cut-out Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0,5 % 8000 µF 24 V DC 1A 24 W <2% Surge current / thermal cut-out Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0,5 % 8000 µF 0.5 kV 1.5 kV 3 kV 4 kV 0.5 kV 1.5 kV 3 kV 4 kV -20 °C...+50 °C -40 °C...+85 °C 78 % EN 50178, EN 60950, IEC950 CSA; GOSTME25; CE EN 61000-6 /-2, -3 -20 °C...+50 °C -40 °C...+85 °C 78 % EN 50178, EN 60950, IEC950 UL508; CSA; Cl. I Div. 2; GOSTME25; CE; Class2 EN 61000-6 /-2, -3 Input/Output 4 / 0.08 / 4 62.5 / 52 / 90.5 Input/Output 4 / 0.08 / 4 62.5 / 52 / 90.5 Derating loss: 33 % @ 60 °C Derating loss: 33 % @ 60 °C Ordering data Connection system Type Screw connection Note Accessories A.40 CP SNT 24W 28V 1A Qty. 1 Order No. Type 9928890028 CP SNT 24W 24V 1A Qty. 1 Order No. 9928890024 connectPower single-phase CP SNT 24 W 15 V 1.5 A CP SNT 24 W 12 V 1.5 A Switch-mode power supplies connectPower INSTAPOWER A L FUSE N + L − N FUSE + − Technical data Input Input voltage Input current Input frequency, max. making current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100 % load Max. capacitance at output Insulation coordination (EN 50 178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data Ambient temperature Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Length x width x height mm² mm Note 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 15 V DC 1.5 A 22.5 W <2% Surge current / thermal cut-out Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0,5 % 8000 µF 12 V DC 1.5 A 18 W <2% Surge current / thermal cut-out Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0,5 % 8000 µF 0.5 kV 1.5 kV 3 kV 4 kV 0.5 kV 1.5 kV 3 kV 4 kV -20 °C...+50 °C -40 °C...+85 °C 78 % EN 50178, EN 60950, IEC950 CSA; GOSTME25; CE EN 61000-6 /-2, -3 -20 °C...+50 °C -40 °C...+85 °C 78 % EN 50178, EN 60950, IEC950 CSA; GOSTME25; CE EN 61000-6 /-2, -3 Input/Output 4 / 0.08 / 4 62.5 / 52 / 90.5 Input/Output 4 / 0.08 / 4 62.5 / 52 / 90.5 Derating loss: 33 % @ 60 °C Derating loss: 33 % @ 60 °C Ordering data Connection system Type Screw connection CP SNT 24W 15V 1.5A Qty. 1 Order No. Type 9928890015 CP SNT 24W 12V 1.5A Qty. 1 Order No. 9928890012 Note Accessories A.41 Switch-mode power supplies connectPower INSTAPOWER connectPower single-phase CP SNT 24 W 5 V 2 A L W A H L FUSE + − N Technical data Input Input voltage Input current Input frequency, max. making current limit Input fuse Surge protection Output Output voltage Output current Output power Max. residual ripple Overload protection Surge protection Mains failure bridge-over time Control at 10...100 % load Max. capacitance at output Insulation coordination (EN 50 178) electrical isolation, output-earth electrical isolation, input-earth electrical isolation, input-output electrical isolation, I/O rail General data Ambient temperature Storage temperature Degree of efficiency at max. load Standards Approvals EMC standards Dimensions Clamping range (nominal / min. / max.) Length x width x height 85...265 V AC, 120...300 V DC 460 mA @ 115 V AC; 250 mA @ 230 V AC 50/ 60 Hz Thermistor 2 A time-lag fuse (internal) Varistor 5 V DC 2A 10 W <2% Surge current / thermal cut-out Varistor 35 ms @ 115 V AC / 160 ms @ 230 V AC 0,5 % 8000 µF 0.5 kV 1.5 kV 3 kV 4 kV -20 °C...+50 °C -40 °C...+85 °C 78 % EN 50178, EN 60950, IEC950 CSA; GOSTME25; CE EN 61000-6 /-2, -3 mm² mm Note Input/Output 4 / 0.08 / 4 62.5 / 52 / 90.5 Derating loss: 33 % @ 60 °C Ordering data Connection system Type Screw connection Note Accessories A.42 CP SNT 24W 5V 2A Qty. 1 Order No. 9928890005