SP-480

SP480
4 8 0 W S i n g l e O u t put with PFC Function
series
Universal AC input
Protections:Short circuit/Over load/Over voltage/Over
temperature
Built-in active PFC function, PF >0.95
Forced air cooling by built-in DC Fan
High power density 5.18w/cubic inch
Low profile:43mm thickness
Built in remote ON-OFF control
Built-in remote sense function
Active AC surge current limiting
Model Number
Output Volts
Output Amps
OVP
3.3 Volts(DC)
5 Volts(DC)
12 Volts(DC)
15 Volts(DC)
24 Volts(DC)
48 Volts(DC)
85 Amps
85 Amps
40 Amps
32 Amps
20 Amps
10 Amps
3.8 ~ 4.45Volt(DC)
5.75 ~ 6.75Volt(DC)
13.8 ~ 16.2Volt(DC)
18 ~ 21Volt(DC)
28.8 ~ 33.6Volt(DC)
57.6~ 67.2Volt(DC)
Min Load
DC Volt Adjust
OCP
Efficiency
SINGLE OUTPUT
SP480-3.3
SP480-5
SP480-12
SP480-15
SP480-24
SP480-48
WWW.ASTRODYNE.COM
0~85Amps
0~85Amps
0~43Amps
0~35Amps
0~22Amps
0~11Amps
2.9~3.6Volt(DC)
4.5~5.5Volt(DC)
10~13.2Volt(DC
13.5~18Volt(DC)
22~27.6Volt(DC)
41~56Volt(DC)
87~103Amps
87~103Amps
45.15~58.05Amps
36.75~47.25Amps
23.1~29.7Amps
11.55~14.85Amps
73%
79%
85%
85%
87%
89%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
SP480
4 8 0 W S i n g l e O u t put with PFC Function
GENERAL SPECIFICATIONS
INPUT SPECIFICATIONS
Input Voltage Range (Note 5)
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
Min Load
Power Factor @ FL
series
90 ~ 264VAC 120~370 Volts(DC)
47-63 Hz
20Amps/115VAC; 40Amps 230VAC
6.5Amps @ 115VAC
3.5 Amps @ 230VAC
< 2mAmps / 240VAC
See Selection Chart
PF > 0.95 / 230VAC
> 0.98 / 115VAC
OUTPUT SPECIFICATIONS
Voltage and Current (Note3) See Selection Chart
Line Regulation
±0.5%: 3.3;5Volts(DC)
±0.3%: 12;15Volts(DC)
±0.2%: 24;48Volts(DC)
Load Regulation
±1.0%: 3;5Volts(DC)
±0.5%: 12~48Volts(DC)
Voltage Tolerance (Note 2)
±2.0%: 3.3;5Volts(DC)
±1.5%: 12;15Volts(DC)
±1.0%: 24;48Volts(DC)
Ripple/Noise (Note 1)
80mVpk-pk: 3.3;5Volts(DC)
120mVpk-pk: 12Volts(DC)
150mVpk-pk: 15;24Volts(DC)
240mVpk-pk: 48Volts(DC)
Hold Up Time @ FL
18mS /230VAC
18mS /115VAC
Setup, Rise Time @ FL
1000mS, 80mS /230VAC
2500mS, 80mS /115VAC
Over Voltage Protection
See Selection Chart
Shut down o/p volt,re power
Over Current Protection
See Selection Chart
Constant current limiting,auto recover
Over Temperature (Note 3)
80°C TSW1: detect on heatsink of power transistor
90°C TSW2: detect on heatsink of power diode
Shut down o/p voltage, auto recover
DC Volt Adjust
See Selection Chart
Peak Load: 10min (Note 4 ) 10% max
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
Safety
Insulation Resistance
EMI
Harmonic Current
Remote Control
Efficiency
Isolation
EMS
UL60950-1, TUV EN60950-1 Approved
≥ 100MΩ / 500Volts(DC)
Compliance to EN55022B (CISPR22B)
Compliance to EN61000-3-2,-3
RC+/RC-: 4~10Volts(DC) Power off
0 ~ 0.8Volts(DC) Power on
See Selection Chart
3000VAC Input - Output
1500VAC Input - Ground
Short Output - Ground
Compliance to EN61000-4-2,3,4,5,6,8,11
ENV50204,EN61000-6-2(EN50082-2)
light Industry Level, Criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-20°C to +60°C (See Derate Curve)
-40°C to +85°C, 10~95% RH
20~90% RH non cond
±0.03% / °C (0-50°C) 120.5KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Weight
278x127 x 43mm (10.94”x5 ”x1.69”)
59.97 oz (1700g)
Note
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
3. TSW1: Detect on heatsink of power transistor.
TSW2: Detect on heatsink of output diode.
4. 33% Duty cycle maximum within every 30 minute. Average output
power should not exceed the rated power.
5. Derating may be needed under low input voltages. Please check the
derating curve for more details.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
4 8 0 W S i n g l e O u t put with PFC Function
WWW.ASTRODYNE.COM
SP480
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
4 8 0 W S i n g l e O u t put with PFC Function
WWW.ASTRODYNE.COM
SP480
series
ASTRODYNE USA: 1-800-823-8082