EFM5 5 W U l t r a m i n i a t u re Open Frame Switchin g Power Supplies series Universal 90-264VAC Input High Efficiency Improved EMI Performance 3000V Isolation Single, Dual & Triple Outputs UL60950-1, EN60950-1 & IEC60950-1 1.6”W x 2.11”L x 0.91”H Model Number Output Voltage Output Amps(max) SINGLE OUTPUT EFM-5000 EFM-5001 EFM-5022 EFM-5002 EFM-5003 EFM-5018 EFM-5005 3.3 Volts(DC) 5 Volts(DC) 9 Volts(DC) 12 Volts(DC) 15 Volts(DC) 18 Volts(DC) 24 Volts(DC) 1.25A 1A 0.55A 0.42A 0.33A 0.27A 0.23A DUAL OUTPUT EFM-5006 EFM-5007 ±12Volts(DC) ±15Volts(DC) ±0.21A ±0.17A TRIPLE OUTPUT EFM-5009 EFM-5011 5±12Volts(DC) 5±15Volts(DC) 0.53±0.1A 0.41±0.1A WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 EFM5 5 W U l t r a m i n i a t u re Open Frame Switchin g Power Supplies INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: 90-264 VAC 47-63 Hz 20A@115VAC, 40A@230VAC OUTPUT SPECIFICATIONS Efficiency Switching Frequency Safety EMC series Single/Duals: 75%~78%, typ EFM-5009: 63% EFM-5011: 61% 100Khz, (fixed, typical) UL60950-1, EN60950-1 EN55022 PHYSICAL SPECIFICATIONS Voltage and Current See Selection Chart Load Regulation (20%-FL) Singles: ± 3%, Duals: ±3% Triple: 0.2 / ±0.3% Line Regulation Singles ±0.1~1%, typ Duals ±0.3~1%, typ Triples: 0.3/±0.1% Cross Regulation (Duals) NA / ±0.1 Preset Accuracy Single/Duals: 1% Triples: 1 /±5% DC Voltage Adjust (typ) ±6% of FS (Primary) Temperature Coefficient ±0.03%/°C Ripple/Noise Single/Dual 100mV Pk-Pk, typ Triple 35mV Pk-Pk, typ Over Voltage Protection Clamp Over Temp. Protection Latching, Auto Recov after Cooling and power restored Short Circuit Protection Continuous, self-recovering Hold Up Time 30 mS, typ DC Output Power 5Watts, max Size Construction Weight 1.6” x 2.11” x 0.91” Open Frame 1.4oz (38g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity EMC / EMI MTBF 0 to +50°C (See Derate) -25 to +71°C * 0 to + 95%, non-cond * FCC/A, VDE 0871/A , CISPRB (Mil Std 217, 25°C) 180,000 Hrs GENERAL SPECIFICATIONS Isolation 3KVAC Input/Output 2500VAC Input-Ground 1000VAC Output-Ground All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 EFM5 5 W U l t r a m i n i a t u re Open Frame Switchin g Power Supplies series OUTPUT DERATING CURVE 100 90 Load, % 80 70 60 50 40 30 20 0 10 20 30 40 50 60 70 Ambient Temperature, °C MECHANICAL DIMENSIONS - SIngle + dual outputs Pin# .91 23.1 1 2 3 4 5 .07 1.8 .04 1 Dimensions are in inches Single Outputs Dual Outputs AC Line AC Neutral +Output NC -Output AC Line AC Neutral +Output Common -Output 5 1.60 40.6 2 4 O .39 10 ACN 3 .69 17.5 .41 10.3 1 ACL .13 3.3 .11 2.8 .79 20 1.85 47 2.11 53.6 WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 5 W U l t r a m i n i a t u re Open Frame Switchin g Power Supplies EFM5 series MECHANICAL DIMENSIONS - Triple outputs WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458