ELP150 series

ELP150
1 5 0 W L E D D r i v e r with PFC
series
Ultra High Efficiency (Up to 92%)
Active Power Factor Correction (typ 0.99)
Constant Output Current
Waterproof (IP67)
All-Round Protection: OVP, SCP, OTP
Complies with Worldwide Safety & EMC Regulations
Lightning Protection
Model Number Output Voltage Range Output Amps Range
Efficiency @ 220Vin
Over Voltage Protection
ELP150-12428
ELP150-12333
ELP150-12214
ELP150-12142
ELP150-12107
ELP150-1285
ELP150-1271
ELP150-1261
ELP150-1253
ELP150-1247
ELP150-1242
ELP150-1235
ELP150-1230
ELP150-1225
92%
92%
92%
92%
91%
91%
91%
91%
91%
91%
91%
90%
90%
90%
514~642 Volts(DC)
400~500 Volts(DC)
257~321 Volts(DC)
170~213 Volts(DC)
128~161 Volts(DC)
102~128 Volts(DC)
85~107 Volts(DC)
73~92 Volts(DC)
64~80 Volts(DC)
56~71 Volts(DC)
50~63 Volts(DC)
42~53 Volts(DC)
36~45 Volts(DC)
30~38 Volts(DC)
256-428Volts(DC)
200-333Volts(DC)
128-214Volts(DC)
85-142Volts(DC)
64-107Volts(DC)
51-85Volts(DC)
42-71Volts(DC)
36-61Volts(DC)
31-53Volts(DC)
28-47Volts(DC)
25-42Volts(DC)
31-35Volts(DC)
18-30Volts(DC)
15-25Volts(DC)
WWW.ASTRODYNE.COM
0.332-0.368 Amps
0.427-0.473 Amps
0.665-0.735 Amps
0.997-1.103 Amps
1.33-1.407 Amps
1.662-1.838 Amps
1.995-2.205 Amps
2.327-2.573 Amps
2.66-2.94 Amps
2.992-3.308 Amps
3.325-3.675 Amps
3.99-4.41 Amps
4.655-5.145 Amps
5.652-6.348 Amps
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
1 5 0 W L E D D r i v e r with PFC
ELP150
INPUT SPECIFICATIONS
PHYSICAL SPECIFICATIONS
Input Voltage Range
Frequency Range
Input Current
Inrush Current
Size
Millimeters
238 x 79.5 x 46
Inches
9.37” x 3.13” x 1.81”
Weight
52.91 oz (1500g)
90-305VAC
47-63 Hz
1.8 Amps max @ 100VAC
0.9 Amps max @ 220VAC
35A @ 230Vin, 25°C cold start
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation
Load Regulation
Ripple/Noise
Turn-on Delay Time
Output Overshoot / Undershoot
Over Voltage Protection
Short Circuit Protection
Over Temperature Protection See Selection Chart
1.0%
3.0%
3% Vo pk-pk / 20MHz
0.1uF ceramic capacitor
10uF eletrolytic capacitor
2S, max.
10% When powered on or off
See Selection Chart
Latch mode. The power supply
shall return to normal operation
after re-power
No damage shall occur when any
output operating in a short
circuit condition. The power supply
shall self-recover when the fault
condition is removed 110°C, max temperature
of components inside the case
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature Storage Temperature
MTBF
Life Time
series
GENERAL SPECIFICATIONS
Safety
USA & Canada UL8750, compliance to UL1012,
UL935 CAN/CSA-C22.2 No. 0, 107.1, CSA-C22.2 No. 250.0
CE Europe
EN61347-1, EN61347-2-13
EMI
EN55015
Efficiency
See Selection Chart
EMS
EN 61000-3-2 Harmonic current emissions
EN 61000-3-3 Voltage fluctuations & flicker
EN 61000-4-2 Electrostatic Discharge (ESD): 8 kV air discharge,4 kV contact discharge
EN 61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility Test-RS
EN 61000-4-4 Electrical Fast Transient / Burst-EFT
EN 61000-4-5 Surge Immunity Test: AC Power Line: line to line 2 kV, line to earth 4 kV
EN 61000-4-6 Conducted Radio Frequency Disturbances Test-CS
EN 61000-4-8 Power Frequency Magnetic Field Test
EN 61000-4-11 Voltage Dips
EN 61547 Electromagnetic Immunity Requirements Applies To Lighting Equipment
-35°C to +70°C 10~100% RH
(See Derate Curve)
-40°C to +85°C, 5~100% RH
311KHrs min, MIL-HDBK-217F
87,000 Hrs @ 220Vin. 80% Load, 45°C
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
1 5 0 W L E D D r i v e r with PFC
ELP150
series
Mechanical Dimiension
BLACK (ACL)
WHITE (ACN)
GREEN (GND)
AC INPUT (3*AWG #18)
DC OUTPUT (2*AWG #18)
RED (V+)
BLACK (V-)
Unspecified tolerance: ±0.2
Derate Curves
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458