RT65 series WWW.ASTRODYNE.COM

RT65
6 5 W Tr i p l e O u t p ut Switching Power Supply
series
Universal AC input
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
All using 105°C long life electrolytic capacitors
High efficiency, long life and high reliability
Model Number
Output Volts
TRIPLE OUTPUT
RT65-A
RT65-B
RT65-C
RT65-D
5 Volts(DC)
12 Volts(DC)
-5 Volts(DC)
5 Volts(DC)
12 Volts(DC)
-12 Volts(DC)
5 Volts(DC)
15 Volts(DC)
-15 Volts(DC)
5 Volts(DC)
24 Volts(DC)
12 Volts(DC)
WWW.ASTRODYNE.COM
Output Amps
Ripple & Noise
6 Amps
2.8 Amps
0.5 Amps
5.0 Amps
2.8 Amps
0.5 Amps
5.0 Amps
2.2 Amps
0.5 Amps
4.0 Amps
1.5 Amps
1.0 Amps
80mV pk-pk
120mV pk-pk
80mV pk-pk
80mV pk-pk
120mV pk-pk
80mV pk-pk
80mV pk-pk
120mV pk-pk
80mV pk-pk
80mV pk-pk
150mV pk-pk
120mV pk-pk
Min Load
0.5~8Amps
0.2~3.5Amps
0~1Amps
0.5~8Amps
0.2~3.5Amps
0~1Amps
0.5~8Amps
0.2~3Amps
0~1Amps
0.5~8Amps
0.2~2Amps
0.1~1Amps
Line Reg
±0.5%
±1.5%
±0.5%
±0.5%
±1.5%
±0.5%
±0.5%
±1.5%
±0.5%
±0.5%
±1..5%
±2.0%
Load Reg
±1.0%
±3.0%
±1.0%
±1.0%
±3.0%
±1.0%
±1.0%
±3.0%
±1.0%
±1.0%
±3.0%
±4.0%
Volt Tolerance
±2.0%
±6.0%
±5.0%
±2.0%
±6.0%
±5.0%
±2.0%
+8,-4%
±5.0%
±2.0%
+4,-6%
±6.0%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
RT65
6 5 W Tr i p l e O u t p ut Switching Power Supply
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
90 ~ 264 VAC; 125~373 Volts(DC)
47-63 Hz
40Amps/230VAC
2.0 Amps. @ 115VAC
1.2 Amps. @ 230VAC
< 2mAmps /240VAC
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation (Note 3)
Load Regulation (Note 4)
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Voltage Protection
Over Current Protection
DC Volt Adjust
See Selection Chart
See Selection Chart
See Selection Chart
See Selection Chart
See Selection Chart
60mS/230VAC
14mS/115VAC
500ms, 20m/230VAC
1200mS, 30mS/115VAC
5Volts only: : 5.75 ~ 6.75VDC
Hiccup mode, auto recover
110 ~ 150% rated output power
5Volts only: 4.75 ~ 5.5V
GENERAL SPECIFICATIONS
Safety
UL60950-1, TUV EN60950-1 Approved
Insulation Resistance
≥ 100MΩ / 500Volts (DC)
EMI
Compliance to EN55022 (CISPR22)
Class B
Harmonic Current
Compliance to EN61000-3-2,-3
Efficiency
77% (RT65-A/B)
78% (RT65-C)
80% (RT65-D)
Isolation
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
EMS
series
Compliance to
EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204,EN61000-6-2(EN50082-2)
Heavy Industry Level, Criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-25°C to +70°C (See Derate Curve)
-40°C to +85°C, 10~95% RH
20~90% RH non cond
0.03% / °C (0-50°C) on +5V output
254.6KHrs min, MIL-HDBK-217F(25°C )
10~500Hz, 5G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Millimeters
129 x 98 x 38
Inches
3.90” x 3.82 ” x 1.42 ”
Weight
15.52 oz (440g)
Note
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Line regulation is measured from low line to high line at rated load.
4. Load regulation is measured from 20% to 100% rated load, and other
output at 60% rated load.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
6 5 W Tr i p l e O u t p ut Switching Power Supply
WWW.ASTRODYNE.COM
RT65
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
6 5 W Tr i p l e O u t p ut Switching Power Supply
WWW.ASTRODYNE.COM
RT65
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458