MEANWELL RSP-1500-5

RSP-1500
1500W Single Output Power Supply
series
Features :
Universal AC input/Full range
ZVS new technology
AC input active surge current limiting
High efficiency up to 91%
Built-in active PFC function,PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC ball bearing fan
Output voltage can be trimmed between 70~100% of the rated output voltage
High power density 8.3W/inch3
Current sharing up to 6000W(3+1)
Alarm signal output
Built-in 12V/0.1A auxiliary output for remote control
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
MODEL
OUTPUT
RSP-1500-5
RSP-1500-12
RSP-1500-15
RSP-1500-24
RSP-1500-27
RSP-1500-48
DC VOLTAGE
5V
12V
15V
24V
27V
48V
RATED CURRENT
240A
125A
100A
63A
56A
32A
CURRENT RANGE
0 ~ 240A
0 ~ 125A
0 ~ 100A
0 ~ 63A
0 ~ 56A
0 ~ 32A
RATED POWER
1200W
1500W
1500W
1512W
1512W
1536W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
10 ~ 13.5V
13.5 ~ 16.5V
20 ~ 26.4V
VOLTAGE TOLERANCE Note.3
INPUT
4.5 ~ 5.5V
2.0%
24 ~ 30V
43 ~ 56V
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1500ms, 100ms at full load
HOLD UP TIME (Typ.)
10ms at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47~63Hz
POWER FACTOR (Typ.)
0.95/230VAC
EFFICIENCY (Typ.)
80%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
17A/115VAC
30A/115VAC
LEAKAGE CURRENT
<2.0mA / 240VAC
14ms at full load
16ms at full load
127 ~ 370VDC
0.98/115VAC at full load
87%
87%
90%
90%
91%
8A/230VAC
60A/230VAC
105 ~135% rated output power
OVERLOAD
Note.5
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover
5.75 ~ 6.75V
13.8 ~ 16.8V
17 ~ 20.5V
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
[email protected](Only for Remote ON/OFF control)
REMOTE ON/OFF CONTROL
Please see the Function Manual
Please see the Function Manual
Please see the Function Manual
WORKING TEMP.
-20 ~ +70
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
(Refer to output load derating curve)
20~90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
57.6 ~ 67.2V
Please see the Function Manual
CURRENT SHARING
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
OTHERS
31 ~ 36.5V
AUXILIARY POWER(AUX)
FUNCTION ALARM SIGNAL OUTPUT
OUTPUT VOLTAGE TRIM
(Note 4)
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
95
5 (TSW2 ) detect on heatsink of power transistor
/ 70% RH
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
62.6K hrs min. MIL-HDBK-217F (25
278*127*83.5mm (L*W*H)
3.0Kg; 4pcs/13Kg/1.19CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:RSP-1500-SPEC 2010-10-18
RSP-1500
1500W Single Output Power Supply
Mechanical Specification
Case No.943A
series
Unit:mm
11.2
240
22.7
16 max.
16
83.5
38.1
38
8-M4 L=5(Both Sides)
278
11.2
240
4
17.5
OUTPUT
+V
4-M4 L=5
-V
CN1 CN2 CN3
86 42 86 42 64 2
75 31 75 31 53 1
I/P
LED
93
127
1
SVR
10
Air flow
direction
13
2
3
AC Input Terminal Pin No. Assignment
Pin No.
1
2
3
Control Pin No. Assignment(CN1,CN2) : HRS DF11-8DP-2DS or equivalent
Assignment
FG
AC/N
AC/L
Pin No.
1
2
3,5,7
Assignment
RCG
RC2
-S
Pin No.
4
6
8
RCG: Remote ON/OFF Ground
RC2: Remote ON/OFF
-S : -Remote Sensing
Terminal
Assignment Mating Housing
TRIM
HRS DF11-8DS HRS DF11-**SC
LS(Current Share) or equivalent or equivalent
+S
TRIM: Adjustment of Output Voltage
LS: Load Share
+S: +Remote Sensing
Control Pin No. Assignment(CN3) : HRS DF11-6DP-2DS or equivalent
Pin No.
1
2
3
Assignment
P OK GND
P OK
RCG
Pin No.
4
5
6
P OK GND: Power OK Ground
P OK: Power OK Signal
RCG: Remote ON/OFF Ground
Terminal
Assignment Mating Housing
AUXG
HRS DF11-6DS HRS DF11-**SC
RC1
or equivalent or equivalent
AUX
AUXG: Auxiliary Ground
RC1: Remote ON/OFF
AUX: Auxiliary Output
PFC fosc : 70KHz
PWM fosc : 100KHz
Block Diagram
+S
I/P
EMI
FILTER
ACTIVE
INRUSH
CURRENT
LIMITING
RECTIFIERS
&
PFC
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
-S
PFC
CONTROL
O.T.P.
O.V.P.
O.L.P.
PWM
CONTROL
LOAD
SHARING
AUX
POWER
DETECTION
CIRCUIT
P OK
REMOTE
CONTROL
RC
LS
FAN
RECTIFIERS
&
FILTER
AUX POWER
(12V/0.1A)
File Name:RSP-1500-SPEC 2010-10-18
RSP-1500
1500W Single Output Power Supply
Derating Curve
series
Static Characteristics
Ta=25
100
Others
+12V,+15V
80
100
90
50
+5V
LOAD (%)
LOAD (%)
60
40
20
-20
80
70
60
0
10
20
30
40 45 50
60
70 (HORIZONTAL)
90
100
120
140
150
160
180
200
220
240
264
INPUT VOLTAGE (V) 60Hz
AMBIENT TEMPERATURE ( )
Function Manual
1.Remote ON/OFF
(1)Remote ON/OFF control becomes available by applying voltage in CN1 & CN2 & CN3
(2)Table 1.1 shows the specification of Remote ON/OFF function
(3)Fig.1.2 shows the example to connect Remote ON/OFF control function
Table 1.1 Specification of Remote ON/OFF
Connection Method
Fig. 1.2(A)
Output on
SW Open
SW Logic
Output off
SW Close
Fig. 1.2(B)
SW Open
SW Close
Fig. 1.2(C)
SW Close
SW Open
Fig.1.2 Examples of connecting remote ON/OFF
(A)Using external voltage source
(B)Using internal 12V auxiliary output
AUX
AUX
2.2K
2.2K
RC1
150
12V typ.
5V
150
RC2
12V typ.
620
RCG
RC1
RC2
SW
RCG
SW
AUXG
AUXG
(C)Using internal 12V auxiliary output
AUX
2.2K
150
12V typ.
RC1
RC2
SW
RCG
AUXG
File Name:RSP-1500-SPEC 2010-10-18
RSP-1500
1500W Single Output Power Supply
2.Alarm Signal Output
(1)Alarm signal is sent out through "P OK" & "P OK GND" pins
(2)An external voltage source is required for this function. The maximum applied voltage
is 50V and the maximum sink current is 10mA
(3)Table 2.1 explain the alarm function built-in the power supply
Function
Description
Output of alarm(P OK)
The signal is "Low" when the power supply is above Low
65% of the rated output voltage-Power OK
(0.5V max at 10mA)
P OK
High or open
The signal turns to be "High" when the power supply
(External applied voltage
is under 65% of the rated output voltage-Power Fail
10mA max.)
series
P OK
R
0.1uF
100K
V
P OK GND
External voltage and R
(The max. Sink is 10mA and 50V)
Fig. 2.2 Internal circuit of P OK (Open collector method)
Table 2.1 Explanation of alarm
3.Output Voltage TRIM
(1)Adjustment of output voltage is possible between 70~100%(Typ.) of the rated output which is shown in Fig. 3.1
(2)Connecting a resistor externally between TRIM and-S on CN1 or CN2 that is shown in Fig. 3.2.
Vout
100%
CN1
90%
TRIM
R(0.5W)
or
80%
CN2
-S
70%
R
Fig. 3.2 Output voltage trimming
0
470
1.8K
OPEN
Fig. 3.1 External Resistor (Typical)
4.Current Sharing
(1)Parallel operation is available by connecting the units shown as below
(+S,-S and LS are connected mutually in parallel):
(2)The voltage difference among each output should be minimized that less than 2% is required
(3)The total output current must not exceed the value determined by the following equation
(Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9
(4) In parallel operation 4 units is the maximum, please consult the manufacture for other
applications
(5) When remote sensing is used in parallel operation, the sensing wire must be connected only
to the master unit
No.1(Master)
V+
+S
-S CN1
LS
V+S
-S CN2
LS
AC/L AC/N
No.2(Slave)
V+
+S
-S CN1
LS
V+S
-S CN2
LS
AC/L AC/N
+S
No.3(Slave)
V+
+S
-S CN1
LS
-S
+V
-V
Load
V+S
-S CN2
LS
AC/L AC/N
No.4(Slave)
V+
+S
-S CN1
LS
V+S
-S CN2
LS
AC/L AC/N
File Name:RSP-1500-SPEC 2010-10-18