RSP-3000 3000W Single Output Power Supply series Features : AC input active surge current limiting High efficiency up to 90% Built-in active PFC function,PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature / Fan Alarm Forced air cooling by built-in DC with fan speed control function Output voltage can be trimmed between 20~110% of the rated output voltage High power density 15.6W/inch3 Current sharing up to 2 units Alarm signal output Built-in 12V/0.1A auxiliary output for remote control Built-in remote ON-OFF control Built-in remote sense function 3 years warranty SPECIFICATION MODEL OUTPUT INPUT RSP-3000-12 RSP-3000-24 RSP-3000-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 200A 125A 62.5A CURRENT RANGE 0 ~ 200A 0 ~ 125A 0 ~ 62.5A RATED POWER 2400W 3000W 3000W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE 22 ~ 28V 43 ~ 56V 1.0% 1.0% 10.8 ~ 13.2V VOLTAGE TOLERANCE Note.3 1.0% LINE REGULATION 0.5% 0.5% 0.5% LOAD REGULATION 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 80ms at full load HOLD UP TIME (Typ.) 10ms at full load VOLTAGE RANGE 180 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.95/230VAC at full load EFFICIENCY (Typ.) 86% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 20A/180VAC 60A/230VAC LEAKAGE CURRENT <2.0mA / 240VAC OVERLOAD 254 ~ 370VDC 89% 100 ~ 110% rated output power Note.5 PROTECTION OVER VOLTAGE Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover 13.8 ~ 16.8V 28.8 ~ 33.6V 90 90 AUXILIARY POWER(AUX) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down [email protected](Only for Remote ON/OFF control) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 5 5 (12V), 110 (12V), 85 5 (24V), 105 5 (48V) (TSW1: detect on heatsink of power transistor) 5 (24V), 75 5 (48V) (TSW2 : detect on heatsink of o/p diode) Please see the Function Manual Please see the Function Manual 2.4 ~ 13.2V 4.8 ~ 28V HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING NOTE 9.6 ~ 56V Please see the Function Manual -20 ~ +70 (Refer to output load derating curve) 20~90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) OTHERS 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE REMOTE ON/OFF CONTROL FUNCTION ALARM SIGNAL OUTPUT OUTPUT VOLTAGE TRIM CURRENT SHARING (Note 4) 90% 16A/230VAC / 70% RH Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 104.5K hrs min. MIL-HDBK-217F (25 278*177.8*63.5mm (L*W*H) 4Kg; 4pcs/16Kg/1.89CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The disposition of output load line each must out of bounds to PSU with ten CM. File Name:RSP-3000-SPEC 2008-12-09 RSP-3000 3000W Single Output Power Supply Mechanical Specification Case No.982B series Unit:mm 278 236.3 40 20 38 63.5 12.5 27 8-M4(Both Sides) L=5mm 236.3 7.9 27 4-M4 L=5mm OUTPUT 4 +V -V 162 Air flow direction + SVR CN3 8 6 4 2 10 8 6 4 2 7 5 31 97 5 31 177.8 LED CN1 CN2 8 642 7 531 TB1 1 13 2 3 10 INPUT 16max. AC Input Terminal Pin No. Assignment Pin No. 1 2 3 Control Pin No. Assignment(CN1,CN2) : HRS DF11-8DP-2DS or equivalent Pin No. Assignment AC/L AC/N FG Assignment RCG RC PV PS 1 2 3 4 Pin No. 5,7 6 8 Terminal Assignment Mating Housing -S CS(Current Share) HRS DF11-8DS HRS DF11-**SC or equivalent or equivalent +S RCG: Remote ON/OFF Ground RC : Remote ON/OFF PV :Output Voltage External Control PS : Reference Voltage Terminal -S : -Remote Sensing CS: Load Share +S: +Remote Sensing Control Pin No. Assignment(CN3) : HRS DF11-10DP-2DS or equivalent Pin No. 1 2 3 Assignment P OK GND P OK P OK GND2 Pin No. 4 5 6 P OK GND: Power OK Ground P OK: Power OK Signal RCG: Remote ON/OFF Ground Assignment P OK2 RCG RC Pin No. Assignment AUXG AUX OLP 7 8 9 AUXG: Auxiliary Ground RC: Remote ON/OFF AUX: Auxiliary Output Pin No. 10 Assignment OL-SD Mating Housing Terminal HRS DF11-10DS HRS DF11-**SC or equivalent or equivalent OLP: OLP Signal OL-SD: OLP Shutdown Signal PFC fosc : 88KHz PWM fosc : 100KHz Block Diagram +S I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC RECTIFIERS & FILTER POWER SWITCHING +V -V -S PFC CONTROL O.T.P. O.V.P. O.L.P. PWM CONTROL LOAD SHARING AUX POWER DETECTION CIRCUIT P OK REMOTE CONTROL RC CS FAN RECTIFIERS & FILTER AUX POWER (12V/0.1A) File Name:RSP-3000-SPEC 2008-12-09 RSP-3000 3000W Single Output Power Supply Derating Curve series Static Characteristics Ta=25 100 80 100 90 50 LOAD (%) LOAD (%) 60 40 20 -20 80 70 60 0 10 20 30 40 50 60 70 (HORIZONTAL) 180 185 190 195 200 210 220 230 240 250 264 INPUT VOLTAGE (V) 60Hz AMBIENT TEMPERATURE ( ) Function Manual 1.Remote ON/OFF (1)Remote ON/OFF control becomes available by applying voltage in CN1 & CN2 & CN3 (2)Table 1.1 shows the specification of Remote ON/OFF function (3)Fig.1.2 shows the example to connect Remote ON/OFF control function Table 1.1 Specification of Remote ON/OFF Connection Method Fig. 1.2(A) Output on SW Open SW Logic Output off SW Close Fig. 1.2(B) SW Open SW Close Fig. 1.2(C) SW Close SW Open Fig.1.2 Examples of connecting remote ON/OFF (A)Using external voltage source (B)Using internal 12V auxiliary output AUX AUX 1K 12V 1K RC 12V typ. SW RCG RC 12V typ. RCG SW AUXG AUXG (C)Using internal 12V auxiliary output AUX 1K 12V typ. RC SW RCG AUXG File Name:RSP-3000-SPEC 2008-12-09 RSP-3000 3000W Single Output Power Supply 2.Alarm Signal Output (1)Alarm signal is sent out through "P OK" & "P OK GND" pins (2)An external voltage source is required for this function. The maximum applied voltage is 50V and the maximum sink current is 10mA (3)Table 2.1 explain the alarm function built-in the power supply Function Description Output of alarm(P OK) The signal is "Low" when the power supply is above Low 80% of the rated output voltage-Power OK (0.5V max at 500mA) P OK High or open The signal turns to be "High" when the power supply (External applied voltage is under 80% of the rated output voltage-Power Fail 500mA max.) series Output of alarm(P OK2) Low (0.5V max at 10mA) High or open (External applied voltage 10mA max.) Table 2.1 Explanation of alarm P OK2 P OK R R 0.1uF V P OK GND V P OK GND2 External voltage and R (The max. Sink is 500mA and 30V) External voltage and R (The max. Sink is 10mA and 30V) Fig. 2.3 Internal circuit of P OK2 (Open collector method) Fig. 2.2 Internal circuit of P OK (Relay, total is 10W) 3.Output Voltage TRIM (1)Adjustment of output voltage is possible between 20~110%(Typ.) of the rated output which is shown in Fig. 3.1 (2)Connecting a resistor externally between PV and-S on CN1 or CN2 that is shown in Fig. 3.2. Vout OVP >120% 120 1~6V -S 100 80 OUTPUT CURRENT (%) PV OUTPUT VOLTAGE (%) 100 Non-Linear 60 40 20 1 2 3 4 5 EXTERNAL VOLTAGE (DC) 6 V 80 60 40 20 20 40 60 80 100 120 V OUTPUT VOLTAGE (%) Fig. 3.1 External voltage (Typ.) File Name:RSP-3000-SPEC 2008-12-09 RSP-3000 3000W Single Output Power Supply series 4.Current Sharing (1)Parallel operation is available by connecting the units shown as below (+S,-S and CS are connected mutually in parallel): (2)The voltage difference among each output should be minimized that less than 2% is required (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9 (4) In parallel operation 2 units is the maximum, please consult the manufacture for other applications (5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit No.1(Master) +V CN1 +S -S CS -V +S -S CS CN2 AC/L AC/N +S No.2(Slave) +V CN1 +S -S CS -S +V -V Load -V +S -S CS CN2 AC/L AC/N File Name:RSP-3000-SPEC 2008-12-09