All the advantages at a glance j U uB BABS cFF DNV j U u c Quint Power 1˜ Input: 1-phase, 85 to 264 V AC, 90 to 350 V DC B ABS F DNV j U u c Quint Power 3˜ Input: 3-phase, 3 x 320 to 575 V AC, 450 to 800 V DC ASI EX F U u c U uc Input: 85 to 264 V AC, 90 to 350 V DC Diode DNV U u c Input: 85 to 264 V AC, 90 to 350 V DC Step Power Input: 1-phase, 85 to 264 V AC 94,5 125 125 125 125 125 125 125 125 125 125 125 125 U u c 125 84 55 Choose your power supply: 24 V / 2,5 A Worldwide use due to wide-range input and international approval package High operational reliability thanks to high MTBF > 500.000 h 24 V / 20 A 24 V / 40 A 24 V / 5 A 24 V / 10 A 24 V / 20 A 24 V / 40 A 30 V / 2,4 A 24 V / 5 A 24 V / 2 x 30 A / 1 x 60 A QUINT-PS-100-240AC/24DC/40 29 38 87 9 QUINT-PS-3x400-500AC/24DC/5 29 38 59 4 QUINT-PS-3x400-500AC/24DC/10 29 38 61 7 QUINT-PS-3x400-500AC/24DC/20 29 38 72 7 QUINT-PS-3x400-500AC/24DC/40 29 38 64 6 ASI QUINT 100-240/2.4 EFD 27 36 68 6 QUINT-PS-100-240AC/24DC/5/EX 29 38 85 3 QUINT-DIODE/40 29 38 96 3 48 V / 5 A 48 V / 10 A 48 V / 20 A 48 V / 10 A 48 V / 20 A 30 V / 4,8 A 24 V / 10 A QUINT-PS-100-240AC/48DC/5 28 66 25 5 QUINT-PS-100-240AC/48DC/10 29 38 24 8 QUINT-PS-100-240AC/48DC/20 29 38 97 6 QUINT-PS-3x400-500AC/48DC/10 29 38 21 9 QUINT-PS-3x400-500AC/48DC/20 29 38 22 2 ASI QUINT 100-240/4.8 EFD 27 36 69 9 QUINT-PS-100-240AC/24DC/10/EX 29 38 86 6 ABS F DNV U u c Active function monitoring via switching output for remote diagnostics 3 3 Reliable starting of heavy loads with power reserve POWER BOOST 3 Function monitoring via floating relay contact for remote diagnostics 231 67,5 66 24 V / 20 A 24 V / 25 A 24 V / 40 A 24 V / 40 A 24 V / 2 A 24 V / 2 A 24 V / 1 A 24 V / 10 A QUINT-DC-UPS/24DC/20 28 66 23 9 QUINT-DC-UPS/24DC/40 28 66 24 2 QUINT-DC-UPS/24DC/40 28 66 24 2 QUINT-DC-UPS/24DC/40 28 66 24 2 MINI-DC-UPS/24DC/2 2866640 MINI-DC-UPS/24DC/2 2866640 MINI-PS-12-24DC/24DC/1 28 66 28 4 QUINT-PS-24DC/24DC/10 28 66 37 8 Maintenance-free capacitor-based power buffer With integrated 1.3 Ah battery module QUINT-BAT/24DC/3.4AH 28 66 34 9 QUINT-BAT/24DC/7.2AH 28 66 35 2 QUINT-BAT/24DC/12AH 28 66 36 5 QUINT-BAT/24DC/3.4AH 28 66 34 9 QUINT-BAT/24DC/7.2AH 28 66 35 2 QUINT-BAT/24DC/12AH 28 66 36 5 MINI-BAT/24DC/0.8AH 2866666 MINI-BAT/24DC/1.3AH 2866417 MINI-PS-48-60DC/24DC/1 28 66 27 1 Trio Power 1˜ U u c Trio Power 3˜ U u c Input: 3-phase, 3 x 320 to 575 V AC 115 115 152,5 152,5 152,5 Mini Power U u c Input: 1-phase, 85 to 264 V AC, (MINI-PS... 90–350 V DC) 152,5 95 107 190 107 45 1 2 130 130 1A 2A 3A 5A 1+1 7A 1+1 10 A 1+1 15 A 1+1 1+1 20 A 1+1 1+1 25 A 1+1 1+1 30 A 1+1 1+1 35 A 1+1 1+1 1+1 = In this case, your require two battery modules of the same capacity. 107 107 107 * 3 99 30 99 20 130 10 99 24 V / 20 A QUINT-DC-UPS/24DC/20 28 66 23 9 130 9 80 22,5 52 24 V / 20 A 130 8 STEP-PS-100-240AC/5DC/4 29 38 91 8 QUINT-DC-UPS/24DC/20 28 66 23 9 130 7 5V / 4 A 24 V / 10 A 130 6 DNV QUINT-DC-UPS/24DC/10 28 66 22 6 hours 5 67,5 67,5 STEP-PS-100-240AC/15DC/2,4 29 38 93 4 130 156 156 156 130 130 164 66 F 24 V / 20 A Select your uninterruptible power supply QUINT UPS here: 3 112 66 125 107 QUINT-BUFFER/24DC/20 28 66 21 3 Input: 1-phase, 85 to 264 V AC minutes 231 66 15 V / 2,4 A Input: 18–32 V DC 107 107 STEP-PS-100-240AC/12DC/3 29 38 92 1 32 40 60 115 60 115 139 22,5 35 DIN rail bus connector ME 17,5 TBUS 1.5/ 5-ST-3,82 GN 27 09 56 1 45 99 3 164 66 107 Uuc 99 3 112 66 125 125 125 110 99 Outdoor installation possible thanks to wide temperature range 100 130 130 64 3 3 3 3 125 145 125 DC-DC-Converter Input: 10–32 V DC, 36–75 V DC 123 123 123 123 130 123 125 145 123 125 Uuc Input: 1-phase, 85 to 264 V AC, 100 to 350 V DC 156 125 MINI UPS / MINI BAT Buffered operation: 27,9–19,2 V DC 130 Output: 24 V DC (Uin –0,5 V) 130 Input: 22,5 to 30 V DC High operational reliability thanks to long mains failure bridging times > 20 ms 3 3 48 V / 0,75 A 12 V / 3 A Quint UPS / QUINT BAT Proper operation of three-phase devices even with permanent failure of one phase 3 3 STEP-PS-100-240AC/24DC/1.5 29 38 94 7 QUINT-PS-100-240AC/12DC/10 29 38 81 1 Optimum device connection with COMBICON plug connectors (up to and including 10 A) 3 24 V / 1,5 A STEP-PS-100-240AC/48DC/0.75 29 38 95 0 130 3 3 3 Compensation of voltage dips and recharging of batteries based on definable output voltage 40 A 62 85 QUINT-PS-100-240AC/24DC/20 29 38 62 0 99 Simplified Start-Up with LED-signaling 2 55 99 3 3 3 3 4 70 24 V / 10 A 99 To connect in parallel to increase power or achieve redundancy 0.2 0.5 1 55 QUINT-PS-100-240AC/24DC/10 29 38 60 4 99 3 3 3 3 seconds 240 160 85 70 12 V / 10 A 130 3 3 3 3 3 24 V / 5 A 240 71 3 3 3 3 3 157 85 55 QUINT-PS-100-240AC/24DC/2,5 QUINT-PS-100-240AC/24DC/5 29 38 57 8 29 38 58 1 TR QU IN TP OW ER IO PO W ER MI NI PO W ER ST EP PO W ER 90 130 130 145 145 130 130 130 130 130 130 130 130 130 55 45 67,5 67,5 24 V / 2,5 A 24 V / 5 A 24 V / 10 A 24 V / 20 A 24 V / 10 A 24 V / 20 A 24 V / 40 A 24 V / 1,3 A 24 V / 1,5 A 24 V / 2 A ± 15 V / 1 A 24 V / 4 A 24 V / 100 W TRIO-PS/1AC/24DC/2.5 28 66 26 8 TRIO-PS/1AC/24DC/5 28 66 31 0 TRIO-PS/1AC/24DC/10 28 66 32 3 TRIO-PS/1AC/24DC/20 28 66 38 1 TRIO-PS/3AC/24DC/10 28 66 45 9 TRIO-PS/3AC/24DC/20 28 66 39 4 TRIO-PS/3AC/24DC/40 28 66 40 4 MINI-PS-100-240AC/24DC/1,3 28 66 44 6 MINI-SYS-PS-100-240AC/24DC/1.5 28 66 98 3 MINI-PS-100-240AC/24DC/2 29 38 73 0 MINI-PS-100-240AC/2x15DC/1 29 38 74 3 MINI-PS-100-240AC/24DC/4 29 38 83 7 MINI-PS-100-240AC/24DC/C2LPS 28 66 33 6 5V / 3 A 24 V / 1,5 A MINI-PS-100-240AC/5DC/3 29 38 71 4 MINI-PS-100-240AC/24DC/1.5/EX 28 66 65 3 * Optional, for supplying further modules of the same system with a regulated 24 V DC voltage, two are required per power supply unit. 10-15 V / 2 A 10-15 V / 8 A MINI-PS-100-240AC/10-15DC/2 29 38 75 6 MINI-PS-100-240AC/10-15DC/8 28 66 29 7 INTERFACE Power Supply Units from PHOENIX CONTACT – Power for all applications Further information on the products introduced here and on the world of solutions from Phoenix Contact can be found at www.catalog.phoenixcontact.com The performance and reliability of a power supply is critical to the operation of today´s complex control systems. Phoenix Contact power supplies are designed to meet and exceed the demands of modern control systems in order to ensure optimum system Industrial Connection Technology, Marking and Mounting Material, Tools Clipline Industrial Plug Connectors Pluscon performance. Or contact us directly! • To connect in parallel to increase power or achieve redundancy • Simplified Start-Up with LED-signaling Power compact Mini Power for decentralised automation • Modular electronic housings for uniform appearance in process measuring and control technology • Flexibility due to special output voltages and special versions • Optimum device connection with COMBICON plug connectors Step Power for installation distributors and flat operator panels • Two-stage housings for building technology TRIO POWER Power pure for series applications • Basic functionality at highest level for 24 V DC • Operational reliability thanks to high voltage resistance up to 300 V AC • Reliable supply with nominal values even with high ambient temperatures up to 55°C • Comfortable secondary grounding through third minus terminal block • Compensation of voltage dips and recharging of batteries based on adjustable output voltage Power perfect for systems and special machine engineering • Universal power supply with wide product range including special versions and accessories • Reliable starting of heavy loads with high inrush currents with power reserve POWER BOOST • Worldwide use in all sectors of industry with extended approvals • High operational reliability of three-phase devices even with permanent failure of one phase • Active function monitoring with switching output and function monitoring via floating relay contact for remote diagnostics • Uninterruptible solutions DC-UPS 10, 20 and 40 A and maintenance-free buffer module Combicon Surge Protection Trabtech Signal Converters Interface Automation Systems AutomationWORX Innovative Power Supply Units PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg, Germany Phone:+49/52 35/3-00 Fax: +49/52 35/3-1 07 99 www.phoenixcontact.com Phoenix CONTACT Phoenix CONTACT © Phoenix Contact 2007 • High system reliability due to long mains failure bridging times with full load and high MTBF > 500.000 h MINI and STEP POWER PCB Connection Technology and Electronic Housings Printed in Germany • Worldwide use due to wide-range input and international approvals QUINT POWER MNR 52001658/01.04.2007-04 The following features and benefits are among the many advantages of Phoenix Contact power supplies.