TEMPERATURE HiTESTER 3441/3442/3446-01/3447-01 Environmental Measuring Instruments ● 3447-01 -01 for HACCP Temperature Recording/Management - Compatible with Platinum temperature-measurement resistors (Pt 100) (-100˚C to 300˚C) - Waterproof construction (IP67), 2-channel measurement - Accommodates a temperature probe with hand switch - Record temperature, time, and name of measurement object - Record using either interval (28,800 data items) or manual (7,200 data items) recording modes ● 3446-01 -01 For TemperatureRecording/Management in Energy Conservation Applications - 1-channel recording for use with Thermocouple (Type K) sensors (-100 C to 1000 C*) 3447 ● 3442(-03) (-03) With Water-resistant Construction for Use in Damp Environments 3442 - Use with Thermocouple (Type K) sensor with water-resistant construction (-100˚C to 1300˚C*) - Max/min temperature recording ● 3441(-02) Basic Temperature HiTESTER - Thermocouple (Type K) sensor (-100˚C to 1300˚C*) - A choice of temperature sensors for different applications * Measurable temperature range varies according to temperature sensor type. 2 Temperature Management of Food Preparation and ■ 3446-01, 3447-01 Record data and memos using either manual or interval recording mode 3447-01 has waterproof construction in both thermometer and sensor. 2-channel Class A temperature measurement using a platinum temperature-measurement resistor. Single-channel recording with 3446 -01 using type K thermocouple (-100˚C to 1000˚C). Both provide two recording modes, manual and interval, allowing recording at arbitrary times or at set intervals. Records product name and inspector name or pass/fail result along with temperature. Send data to a computer by RS-232C connection. Print recorded data (using the optional Printer 9670) Screen Display *1 Maximum recording time in interval recording mode ➀ ➄ Note that the amount of continuous recording time available may be limited by remaining battery charge. ➁ ➅ Interval 1 sec ➂ When using only interval recording, the relationship between recording interval and maximum recording time are as shown below: Recording Time Interval Recording Time Interval 8 h 15 sec 5 days 1 min 2 sec 16 h 10 sec 3 days, 8 h 5 sec 20 sec 1 days, 6 h 30 sec 6 days 16 h 2 min 10 days 5 min 10 min Recording Time Interval 20 days 15 min Recording Time 300 days 100 days 30 min 600 days 40 days 20 min 200 days 60 min 400 days ➇ ➈ ➃ 1200 days ■3447-01 Measurement Specifications Sensor type Measurement current No. of inputs Measurement range Resolution Measurement accuracy, thermometer Sampling rate Water resistance ➆ ➀REC: recording ➁INTVL: Interval recording mode, recording interval ➂ Time display ➃ Channel number being recorded (3447-01) ➄APS:auto power save function ON and battery charge remaining display ➅ITEM/ID: Product name/name of inspector ➆Memo, such as product name ➇Data number ➈ Temperature display ■3446-01 Measurement Specifications : Platinum temperature-measurement resistor Pt 100 (3 line type) : 0.5 mA : 2 channel : -100.0 to 300.0˚C : 0.1˚C : ±0.1% rdg. ±0.4˚C Sensor type Resolution : 0.1˚C (-100.0 to 300.0˚C), 1˚C (-100 to 1000˚C) : 1/second : IP67 (EN60529:1991) Sampling rate : 1/second No. of inputs : Type K thermocouple : 1 channel Measurement range : -100 to 1000˚C Measurement accuracy : ±0.1% rdg. ±0.5˚C (with 0.1˚C resolution) ±0.2% rdg. ±1˚C (with 1˚C resolution) ■ 3446-01 / 3447-01 Common Specifications Measurement Modes Manual recording : Temperature recording by key operation (Recording also possible by the key on the 9479 Probe. 3447-01 only) Data recorded : Time, temperature, item, ID, comparator test result Data items recorded : Max 7,200 (for the 3447-01: 4,800 with 2-ch recording) Interval recording : Measurement values recorded at a set interval Data recorded : Time, temperature, item, ID, comparator test result Data items recorded : Max 28,800 (with the 3447, 14,400 with 2-ch recording) Recording interval : OFF, 1, 2, 5, 10, 15, 20, or 30 seconds, 1, 2, 5, 10, 15, 20, 30, or 60 minutes Display *Manual recording when set to OFF LCD display : Measured temperature, date, time, item, ID, etc. Item display : 12 character (alphanumeric) item display, holds up to 300 entries ID display : 12 character (alphanumeric), holds up to 100 entries * Item and ID settings can be made from a computer using the 9674 PC software. Functions Comparator : Set for individual items (Hi, IN, Lo evaluation) Result output : Result display, buzzer output Clock : Real time control (year, month, day, hour, minute, second) Data read-out : Measurement data, time, data number Display hold : Holds measurement value. Auto power save : Automatically switches the power off if no key is pressed for 10 minutes. Display automatically turned off during interval recording. * Auto power save function can be disabled. Data back-up : Measurement data, Setting data Interface : RS-232C (using dedicated cable) Applicable standards : Safety, EN61010-1:2001; Measurement category I, Pollution degree 2/EMC, EN613260:1997+A1:1998+A2:2001 Ambient conditions for use : 0 to 40˚C, 80% rh or less (non-condensating) for storage : -10 to 50˚C, 80% rh or less (non-condensating) Power supply : 4 LR03 (AAA) alkaline dry cell batteries Maximum rated power : 60 mVA Continuous use time : 15 days (at 20˚C, with auto power save disabled) 1 month (at 20˚C, using auto power save, with a recording interval of 1 min) Dimensions/mass : Approx. 66 x 150 x 31.5 mm (2.6 x 5.9 x 1.25 in), approx. 240 g (8.47 ozs) Accessories : Batteries, strap band Storage, Support for Electronic Device Temperation Control ■ Settings can be made from and data transferred to a connected computer When a PC is connected to the 3446-01/3447-01, it can be used to make various settings (item, ID, comparator), or to store recorded data transferred from the Temperature HiTESTER. Computerization of temperature management can greatly increase work efficiency. The optional RS-232C Package 9674 is used for PC communications. RS-232C Package 9674 (Optional) (Package contents: RS-232C cable, PC software on CD-ROM) RS-232C cable (cable length: 2 m; Connector on PC side: Dsub-9 pin; Connector on thermometer side: Dedicated connector) PC software (Windows 95/98/Me/NT 4.0/2000/XP compatible) Functions: Item/ID setting, comparator setting, data list display, graph display, printing, file storage (in proprietary format or text format) Printer 9670 When outputting recorded data to the optional Printer 9670, use the RS-232C cable provided in the RS-232C Package 9674 and a commercially-available connector adapter (male Dsub-9 pin <-> male Dsub-25 pin). ■3441/3442 Extended Operation, Max/Min Temperature Recording, Water-resistant Construction (3442 only) Recording of maximum temperature and minimum temperature Current temperature display ▲ ▲ The 3442 has a water-resistant construction. Measurement in damp environments is possible by using the thermometer in combination with the 9472 or 9475 temperature probe. Choose from 9 different temperature sensors (optional), according to your application. MAX display MIN display The 3441 and 3442 support temperature management by recording maximum and minimum temperatures in memory. By pressing the MAX/MIN key, you can switch to display of the current maximum and minimum temperatures at any time. ■3441/3442 Specifications (accuracy at 23˚C ±5˚C, 80% rh or less) Sensor : Type K thermocouple Measurement range : -100˚C to 1300˚C (-148˚F to 2372˚F) Resolution : 0.1˚C (100 to 199. 9˚C), 1˚C (200 to 1300˚C)/ 0.1˚F (-148˚F to 392˚F), 1˚F (393˚F to 2372˚F) Measurement accuracy : ±0.1% rdg. ±0.8˚C (from -100 to 199.9˚C)/ ±0.1% rdg. ±1.5˚F (-148˚F to 392˚F) ±0.2% rdg. ±1˚C (from 200 to 1300˚C)/±0.2% rdg. ±1.8˚F (393˚F to 2372˚F) (Accuracy of temperature sensor is added.) Temperature coefficient : 0.03˚C/˚C (from -100 to 199.9˚C) / 0.054˚F/˚F (-148˚F to 392˚F) 0.05˚C/˚C (from 200 to 1300˚C) / 0.09˚F/˚F (393˚F to 2372˚F) Sampling rate : 2 / second Display : LCD display Reference contact compensation : Automatic Functions : Max/Min temperature recording and display, display data hold, sensor discontinuity display (- - - - ), over-range display (O.F, - O.F), auto power save (operates after 30 min, can be disabled), low battery warning Operating environment : Indoors, at altitude up to 2000 m Ambient conditions for use : 0 to 40˚C (32˚F to 104˚F), 80% rh or less (non-condensating) for storage : -10 to 50˚C (14˚F to 122˚F), 80% rh or less (non-condensating) Applicable standards : Safety, EN61010-1:2001; Measurement category I, Pollution degree 2/EMC, EN613260:1997+A1:1998+A2:2001 Water-resistant construction: EN60529:1991 IP54 : 4 R6P manganese dry cell batteries or 4 LR6 alkaline Power supply batteries (AAA) Maximum rated power : 35 mVA Continuous operating : 200 hours or more (using manganese batteries) Dimensions/mas : Approx. 74(W) x 155(H) x 24(D) mm (2.6 x 5.9 x 0.95 in), approx. 160g (5.6 oz) (not including batteries or sensor) : Batteries, strap band Accessories 3 4 ■ Choose from a wide range of temperature sensors for various applications (optional) ■ TEMPERATURE PROBE for 3441 / 3442 unit=mm (inch) ●:water--resistant structure 9472 / 9473 SHEATH TYPE 9474 / 9475 SHEATH TYPE 9180 / 9183 SHEATH TYPE 9182 SHEATH TYPE 9181 SURFACE TYPE 9476 SURFACE TYPE Related Products ■ TEMPERATURE PROBE for 3446-01 9472-50 / 9473-50 SHEATH TYPE 9476-50 SURFACE TYPE Management of temperature recordings The 3412 -50 produces a voltage output of 1 mV per degree Centigrade.Using the thermometer and recorder together allows recording of temperature variations. ■ TEMPERATURE PROBE for 3447-01 ●:waterproof structure 9479 SHEATH TYPE with Hand Switch 9478 SHEATH TYPE * The CE marking does not pertain to the waterproof structure. Also, the recorder, 9036 AC adapter, 9094 output cord, and temperature probes are optional. Range: –50˚C to 999˚C ( – 58 to 1830 ˚ F) , Sensor : Thermocouple K (CA), Unit accuracy: ±0.2% f.s.±1dgt. Analog output: 1mV / ˚C, Power supply: 6F22 battery TEMPERATURE HiTESTER 3412-50 waterproof structure water-resistant structure Item Thermocouple material Tolerance Response (90%)* Size of Sheath Cable Grip heat resistance Max use temperature 9472 (-50) 9473 (-50) 9474 9475 9183 9180 K type (Chromel/Almel) The greater of ±1.5˚C(2.7˚F) or ±0.4% of measured temperature About 5 sec About 10 sec About 5 sec About 10 sec About 5 sec φ2.3×150mm φ4.8×300mm φ2.3×100mm φ4.8×100mm φ3.2×150 mm General use (–20˚C to 90˚C,– 4˚F to 194˚F) 1 m 150˚C 80˚C –100~300˚C 0~800˚C –100~300˚C –100~500˚C –50~750˚C –148~572˚F 32~1472˚F –148~572˚F –148~932˚F –58~1382˚F * Sheath type: Responsiveness in ice water at 0˚C (32˚F) and in boiling water at 100˚C(212˚F) Surface type: Responsiveness on a metal surface at 0˚C (32˚F) and at 100˚C(212˚F) TEMPERATURE HiTESTER 3446-01 TEMPERATURE HiTESTER 3447-01 ■ Options for 3446-01, 3447-01 RS-232C PACKAGE (with PC Software) CARRYING CASE SHEATH TYPE TEMPERATURE PROBE SHEATH TYPE TEMPERATURE PROBE SURFACE TYPE TEMPERATURE PROBE SHEATH TYPE TEMPERATURE PROBE SHEATH TYPE TEMPERATURE PROBE PRINTER (with 1 roll of Recording Paper) AC ADAPTER for 9670 RECORDING PAPER (for 9670, 80mm × 25m, 4 rolls) 9674 9386-01 9472-50 9473-50 9476-50 9478 9479 9670 9671 9237 The greater of ±2.5˚C(4.5˚F) *2 About 3 sec φ20 mm φ15 mm 80˚C –40~500˚C –40~932˚F 150˚C –50~400˚C –58~752˚F 9182 About 5 sec φ3.2×500mm (0˚C~150˚C) 2m 90˚C –50~750˚C –58~1382˚F 9478 9479 Pt 100(3-wires)*1 ± 0.15˚C ±0.002 T*3 About 5 sec φ2.3×100 mm (– 40˚C~120˚C) 1m 80˚C –100~300˚C –148~572˚F TEMPERATURE HiTESTER 3441 ( ˚C only) TEMPERATURE HiTESTER 3441-02 ( ˚C/ ˚F selectable) TEMPERATURE HiTESTER 3442 ( ˚C only) TEMPERATURE HiTESTER 3442-03 ( ˚C/ ˚F selectable) ■ Options for 3441(-02), 3442(-03) SHEATH TYPE TEMPERATURE PROBE SURFACE TYPE TEMPERATURE PROBE SHEATH TYPE TEMPERATURE PROBE SHEATH TYPE TEMPERATURE PROBE SHEATH TYPE TEMPERATURE PROBE SHEATH TYPE TEMPERATURE PROBE SHEATH TYPE TEMPERATURE PROBE SHEATH TYPE TEMPERATURE PROBE SURFACE TYPE TEMPERATURE PROBE CARRYING CASE 1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] 9181 *1 Platinum Temperature-measurement Resistor *2 9180, 9182: The greater of ±2.5˚C(4.5˚F ) or ±0.75% of measured temperature 9476: (–0.03 ×T)˚C to + 2.5˚C at 100˚C<(T–Ts) 9181: (–0.035×T)˚C to + 2.5˚C at 100˚C<(T–Ts) T: measured temperature, Ts: environmental temperature *3 T: measured temperature HIOKI (Shanghai) Sales & Trading Co., Ltd. : HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] 9476 (-50) 9180 9181 9182 9183 9472 9473 9474 9475 9476 9386 DISTRIBUTED BY Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : Room 303, Profit Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] All information correct as of Sep. 25, 2008. All specifications are subject to change without notice. 3441-3447SE5-89E Printed in Japan