INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES Safety Standards Measuring Instruments 3159 3153 3158 3154 This electrical safety test instrument series is designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. A multitude of automation and laborsaving features are provided to ensure effective testing for a wide variety of requirements and test conditions. Select the most appropriate model for your applications. 3153 AUTOMATIC INSULATION / WITHSTANDING HiTESTER 3159 INSULATION / WITHSTANDING HiTESTER 3158 AC WITHSTANDING VOLTAGE HiTESTER 3154 DIGITAL MΩ HiTESTER 1 Model 3153 Automatic Insulation Voltage Withstand Testing Standards-Based Testing Voltage Control from a PC Full Remote Control Comparator/Timer All test parameters can be controlled by RS-232C or GP-IB, including test voltage, cut-off current, resistance threshold and timer durations. Start-stop control can be provided with the 9613 single hand remote control or 9614 twohand remote control. Includes built-in pass-fail comparator and timer functions for easy compliance testing to various safety standards such as those for Electrical Appliance Safety Regulations. Settable Ramp Up/Down Test Voltage Timing Test Status Read/Write Program Function Raising and lowering of test voltage can be set for voltage withstand testing. Test Voltage Ramp Timer Functions Rise Test Fall Test conditions can be stored and recalled to support complete automation by sequencer. Up to 32 files can be stored with up to 50 steps per file. Up to 32 files Time Fluorescent Display Tube The display uses a bright, easy-toread fluorescent tube. Analog Voltmeter The test voltage can be verified not only on the digital display but also on the analog meter. Danger Lamp The warning light flashes during testing and whenever high voltage is present at the terminals. External Switch Start/stop may be controlled with the 9613 or the 9614 . (The 9613 and 9614 are options.) Test Mode Selection Three test modes are selectable: 1. Manual test modes: ACW, DCW, I 2. Automatic test modes: W→ I, I → W 3. Programmed test modes: testing by preprogrammed functions. ● Automation Support ● Save 10 Sets of Test Conditions ● Interlock Protect Function ● Auto Discharge Feature ● Zero-V Switching ● PWM Switching Technique Automation features include programmable testing modes, EXT I/O, RS-232C, GP-IB, connection scanning and various data management functions. Any charge on the object under test is discharged by the test instrument, so there is no residual charge after testing. (DC voltage Store up to 10 sets of test conditions for voltage withstand and insulation resistance modes, so you can quickly switch among the test conditions. (Save/Load) Test voltage on/off switching can be forced to occur only at sine wave zero-crossings. (AC voltage withstand testing) To ensure safety during automatic testing, test output can be interrupted and testing inhibited by input signals from automatic sensing devices. Enhanced accuracy is obtained by preventing variations in supply voltage from affecting test voltage. 2 Wide Range of Functions for Various Conditions 1. Pass Hold Function (0: No Hold, 1: Hold) The pass state is held when it is activated.This is convenient for verifying the decision value. 2. Fail Hold Function (0: No Hold, 1: Hold) The fail state is held when it is activated.This is convenient for temporarily stopping the test process. 3. Hold State (0: No Hold, 1: Hold) This saves the state when the Stop key is pressed during a test to unconditionally end the test. 4. Momentary Out (0: Disabled, 1: Enabled) This function outputs a voltage only when the Start key is being pressed. The Start key is effective both for EXT SW and external I/O. 5. Double Action (0: Disabled, 1: Enabled) This function allows testing to start only if the Start key is pressed within a half second after the Stop key. 6. Fail Mode (0: Disabled, 1: Enabled) This function allows the Hold state to be released only by the Stop key on the instrument panel. 7. "START" Interface Command (0: Disabled, 1: Enabled) This specifies whether the "START" command is enabled. 8. Interlock Function (0: Disabled, 1: Enabled) This specifies whether the interlock terminal for external I/O is enabled. 9. Maximum Output Voltage Sets the upper limit of the test voltage. 10. Insulation Resistance Measurement Range (0: Fixed Range, 1: Automatic Range) This specifies whether the measurement range for insulation resistance testing should be fixed or automatically determined. 1 2 3 4 5 6 7 8 10111213 1415 Address specified for GP-IB control 9 (Various functions can be specified with the SHIFT + STOP keys) 11. Insulation Resistance Test End Mode 0: Test for the specified time 1: Stop when "pass" is detected 2: Stop when "fail" is detected This specifies the method of ending insulation resistance tests. 12. Ramp Time Setting 0: No judgment during ramp-up 1: Judgment during ramp-up This specifies whether the judgment is enabled during ramp-up. Valid only during voltage withstand testing. 13. PC Interface 0: RS-232C (PC, 9600 bps) 1: RS-232C (PC, 19200 bps) 2: GP-IB This specifies the type of PC interface to use. 14. Electrical Discharge Function (0: Disabled, 1: Enabled) This specifies whether the electrical discharge function is enabled at the end of testing. 15. Test Signal Output 0: ON also when TEST indicator is flashing 1: OFF when TEST indicator is flashing 2: ON only when TEST indicator is flashing (excluding ramp down time) This specifies whether the TEST signal of the external I/ O should be outputwhen the TEST indicator is flashing. Enhanced System Measurements Maximum 32-Channel Multi-Point Testing Simultaneous Protective Ground Continuity Testing Model 3930 HIGH VOLTAGE SCANNER Safety Inspection System Combine Model 3153 with the 3930 HIGH VOLTAGE SCANNER to perform insulation withstand testing easily. Single-end inputs test up to 8 points (between any 4 points) per instrument, and can connect up to 4 instruments together. Model 3930 Specifications No. of Channels Operating Voltage Multi-Mode: 4 High-Low channels Single-End Mode: 8 High-Common channels 5 kV AC, 7 kV DC Action/Recovery Time 6 ms or less Supply Voltage 24 V DC ±5% (at control signal input connector) Size & Mass Approx. 320(W) × 90(H) × 250(D) mm, 3 kg. Combine Model 3153 with the 3157-01 AC GROUNDING HiTESTER and a general-purpose sequencer for a simple safety test inspection system that includes protective ground continuity and insulation withstand testing. Model 3157-01 AC GROUNDING HiTESTER Settable current ranges: 3.0 to 31 A AC Max. output power: 130VA Resistance measurement range: 0 to 1.800 Ω 3 A Full Line-up of Models to Suit Various Needs Model 3153 AUTOMATIC INSULATION / WITHSTANDING HiTESTER ■ Insulation and AC/DC continuous voltage withstand testing ■ Safety standards compliance testing ■ Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand) ■ Zero-V Switching (voltage withstand testing) ■ Electrical Discharge function (DC voltage withstand, insulation testing) ■ Automated testing support ■ Interlock Protect function ■ Remote controllable EXT I/O GP-IB RS-232C Scanner Connector Voltage Withstand Testing Insulation Testing AC: 0.20 to 5.00 kV, 500 VA DC: 0.20 to 5.00 kV, 50 VA 0.01 to 100.0 mA DC: 50 to 1200 V 0.10 to 9999 MΩ Model 3159 INSULATION / WITHSTANDING HiTESTER Output Terminal ■ Insulation and voltage withstand testing ■ Safety standards compliance testing ■ Stores up to 10 sets of test conditions (10 each for insulation and voltage withstand) ■ Voltage comparator functions (voltage withstand testing) ■ Zero-V Switching (voltage withstand testing) ■ Electrical Discharge function (insulation testing) ■ Automated testing support ■ Interlock Protect function Status Out ■ Remote controllable Beeper Volume Adjust Output Terminal Voltage Withstand Testing Insulation Testing AC: 0 to 2.5 kV/5.0 kV, 500 VA DC: 500/1000 V 0.01 to 120.0 mA 0.5 to 2000 MΩ RS-232C Model 3158 AC WITHSTANDING VOLTAGE HiTESTER EXT I/O ■ Safety standards compliance testing ■ Stores up to 20 sets of test conditions ■ Voltage comparator functions ■ Zero-V Switching ■ Electrical Discharge function ■ Automated testing support ■ Interlock Protect function ■ Selectable remote controls Beeper Volume Adjust Voltage Withstand Testing AC: 0 to 2.5 kV/5.0 kV, 500 VA 0.01 to 120.0 mA RS-232C EXT I/O 4 EXT I/O Output Signals External control can be provided by various signals (signal lines have photocoupler isolation) Pin I/O Signal Function 1 OUT READY LO when in "ready state" 3 OUT U-FAIL LO when in "fail state" for the upper bound 2 4 5 6 7 OUT L-FAIL LO when in "fail state" for the lower bound OUT TEST LO when in "pass state" LO when in "test state" OUT H.V.ON LO when voltage is present at the output terminals IN 8 EXT-E When LO, external I/O input signals are enabled IN 9 10 PASS OUT START When LO, it functions as a "Start" key IN STOP When LO, it functions as a "Stop" key IN INT.LOCK Interlock engaged when open 11 OUT W-MODE LO during voltage withstand testing 13 OUT W-FAIL LO when in "fail state" for voltage withstand testing 12 14 15-16 OUT I-MODE LO during insulation testing OUT Pin I/O Signal Function 17-18 IN EXT.COM Common terminals for external devices 19 20 21 22 23 24 25 26 OUT STEP-END LO when at the end of a step OUT FILE-END LO when at the end of a file IN FILE-E LO when FILE 0 to 4 is in use IN FILE-1 IN IN IN IN FILE-0 File selection FILE-2 File selection FILE-3 FILE-4 File selection File selection File selection 33-34 OUT ISO.DCV Internal power 5V DC (60 mA) 35-36 IN EXT.DCV External power supply (5 to 30V DC) I-FAIL LO when in "fail state" for insulation testing IN ISO.GND Ground inputs for external devices Pin Status Out When the output conditions set by the DIP switches are satisfied (OR condition), output is provided at relay contacts. 1. H.V.ON Output voltage generation 3. PASS Passed 2. TEST 4. FAIL 5. INT.LOCK 6. READY 7. EXT.CONT. 8. POWER.ON 3 OUT U-FAIL LO when in "fail state" for the upper bound 2 4 5 6 7 8 9 Failed 12 Under external control Powers the 3159 on OUT L-FAIL LO when in "fail state" for the lower bound OUT OUT PASS TEST LO when in "pass state" LO when in "test state" OUT H.V.ON LO when voltage is present at the output terminals IN IN IN EXT-E When LO, external I/O input signals are enabled START When LO, it functions as a "Start" key STOP When LO, it functions as a "Stop" key IN INT.LOCK Interlock engaged when open 11 OUT W-MODE LO during voltage withstand testing 13 OUT W-FAIL LO when in "fail state" for voltage withstand testing 14 15-18 OUT I-MODE LO during insulation testing OUT I-FAIL LO when in "fail state" for insulation testing IN ISO.COM Ground inputs for external devices 33-36 OUT ISO.DCV Internal power 15V DC (100 mA) Pin I/O Signal OUT READY LO when in "ready state" 3 OUT U-FAIL LO when in "fail state" for the upper bound 4 5 6 7 8 9 10 15-18 OUT L-FAIL LO when in "fail state" for the lower bound OUT OUT PASS TEST LO when in "pass state" LO when in "test state" OUT H.V.ON LO when voltage is present at the output terminals IN IN IN EXT-E When LO, external I/O input signals are enabled START When LO, it functions as a "Start" key STOP 1. PASS Hold function 2. FAIL Hold function 3. Hold function 4. Momentary out 5. Double actions 6. FAIL mode 7. "START" RS command 8. Interlock function 9. Voltage Comparator position 10.Insulation Resistance measurement range 11.Insulation Resistance Test End mode Function 1 2 1. PASS Hold function 2. FAIL Hold function 3. Hold function 4. Momentary out 5. Double actions 6. FAIL mode 7. "START" interface command 8. Interlock function 9. Maximum Output Voltage 10.Insulation Resistance measurement range 11.Insulation Resistance Test End mode 12.Ramp Timer setting 13.PC Interface 14.Electrical Discharge function 15.TEST signal output Function OUT READY LO when in "ready state" 10 Ready Signal 1 Testing in progress Interlocked I/O Various Function Settings When LO, it functions as a "Stop" key IN INT.LOCK Interlock engaged when open IN ISO.COM Ground inputs for external devices 33-36 OUT ISO.DCV Internal power 15V DC (100 mA) 1. PASS Hold function 2. FAIL Hold function 3. Hold function 4. Momentary out 5. Double actions 6. FAIL mode 7. "START" RS command 8. Interlock function 9. Voltage Comparator position 5 Specifications ■ Voltage Withstand Testing Model 3153 AUTOMATIC INSULATION / WITHSTANDING HiTESTER Output voltage Voltage output method Transformer capacity Model 3159 Model 3158 INSULATION / WITHSTANDING HiTESTER AC WITHSTANDING VOLTAGE HiTESTER AC DC AC 0.20 to 5.00 kV PWM switching method (zero-switching) 0.20 to 5.00 kV Two ranges: AC 0 to 2.5 or 5.0 kV PWM switching method Zero-switching 500 VA (rated 30 minutes) ... 500 VA (rated 30 minutes) ... 50 VA (continuous) Output capacity Voltage adjustment method Output voltage accuracy ... Digital setting (0.01 kV setting resolution) Manual adjustment ±1.5% of setting voltage ±2 dgt. ... Voltage change rate ±7% or less ±16% or less (max. 5 kV at 100 mA → (max. 5 kV at10 mA → unloaded: unloaded: with resistive load)*2 with resistive load)*2 ... Voltage waveform Sine wave (5% or less distortion, unloaded) ... Power waveform Voltage frequency 50 or 60 Hz ±0.2% ... Power synchronization Output ripple voltage 6% of output voltage or less ... Output current 100 mA *1 10 mA (continuous) Average rectified effective value display Average display Voltmeter Digital: 0.00 to 5.00 kV (full scale) Accuracy: ±1.5% f.s. Analog: 0 to 5 kV (full scale) Accuracy: ±5% f.s. ... (at 5 kV DC, 10 mA, resistive load) ... Average rectified effective value display Digital: 0.00 to 5.00 kV (full scale) Accuracy: ±1.5% f.s. Analog: 0 to 5 kV (full scale) Accuracy: ±5% f.s.a Current measurement range 0.01 to 100.0 mA 0.01 to 10.0 mA 0.01 to 120.0 mA Indicated value range 10 or 100 mA 10 mA 2, 8, 32 or 120 mA Measurement resolution Current measurement accuracy 0.00 to 10.00 or 0.01 mA (10-mA range) 10.1 to 100.0 or 0.1 mA (100-mA range, AC only) ± (2% rdg. + 5 dgt.) common to each range *3 *1. Time vs. Output Voltage (at 23˚C ambient) Current Measurement Range Max. Test Time Standby Time 60 mA < 1 < 100 mA 15 minutes 15 minutes 1 < 60 mA 0.01 mA (2- or 8-mA range), 0.1 mA (32-mA range), 1 mA (120-mA range) continuous ± (3% f.s. + 20 µA) for all ranges (at 5% power distortion or less) *2. Unloaded = 40 MΩ load (instrument input impedance) *3. Plus scanner accuracy, when used. none ■ Insulation Resistance Testing Model 3153 Model 3159 Model 3158 Test voltage Output voltage: Positive polarity 50 to 1200V DC Voltage adjustment method: Digital setting (1V resolution) Output voltage accuracy: ±1.5% ±2 dgt. of setting level Rated voltage: 500 or 1000V DC Unloaded voltage: 1 to 1.2 times rated voltage ... Rated measurement current 1 mA 1 to 1.2 mA ... Short-circuit current 200 mA or less 4 to 5 mA (500V) 2 to 3 mA (1000V) ... Voltmeter Average display Digital: 0 to 1200V DC (full scale) Accuracy: ±1.5% rdg. ±2 dgt. Analog: 0 to 1200V DC Accuracy: ±5% f.s. (5 kV full scale) Measurement range/ accuracy 0.100 to 1.049 MΩ 1.05 to 10.49 MΩ*1 10.5 to 104.9 MΩ*1 105 to 9999 MΩ*1 Fundamental accuracy: ±4% rdg.*2 *1. Measurement range changes according to test voltage. *2. Plus scanner accuracy, when used. Average display Digital: 0 to 1200V DC (f.s.) ... Analog: not applicable 0.5 to 999 MΩ (500V)/±4% rdg. 1 to 999 MΩ (1000V)/±4% rdg. 1000 to 2000 MΩ /±8% rdg. ... 6 ■ Decision Function Decision method Decision results Decision processing Model 3153 Model 3159 Window comparison method (digital specification) Model 3158 UPPER-FAIL: Measured current (insulation resistance value) exceeded the specified upper bound. PASS: Measured current (insulation resistance value) was between the specified upper and lower bounds during the specified time elapsed LOWER-FAIL: Measured current (insulation resistance value) was less than the specified lower bound (Note: Model 3158 has no insulation resistance function) For each decision result, output the display portion, the beeper sound, and EXT I/O signal Specification ranges Voltage withstand testing: ACV: 0.1 to 100 mA (upper bound) / 0.1 to 99 mA (lower bound) DCV: 0.1 to 10 mA (upper bound) / 0.1 to 9.9 mA (lower bound) Insulation testing: 0.10 to 9999 MΩ (same upper/lower bounds) Voltage withstand testing: 0.1 to 120 mA (upper bound) / 0.1 to 119 mA (lower bound) Insulation testing (Model 3159 only): 0.2 to 2000 MΩ (same upper/lower bounds) Specification resolution Voltage withstand testing: 0.1 mA (0.1 to 9.9 mA), 1 mA (10 to 100 mA) Insulation testing: 0.01 MΩ (0.10 to 9.99 MΩ), 0.1 MΩ (10.0 to 99.9 MΩ), 1 MΩ (100 to 9999 MΩ) Voltage withstand testing: 0.1 mA (0.1 to 9.9 mA), 1 mA (10 to 120 mA) Insulation testing (Model 3159 only): 0.01 MΩ (0.2 to 2 MΩ), 0.1 MΩ (2.1 to 20 MΩ), 1 MΩ (21 to 200 MΩ), 10 MΩ (210 to 2000 MΩ) ■ Timers Model 3153 Testing timer Specification range: 0.3 to 999 s Specification resolution: 0.1 s (0.3 to 99.9 s), 1 s (100 to 999 s) Accuracy: ±0.5% of specified value Model 3159 Model 3158 Specification range: 0.5 to 999 s Specification resolution/accuracy: 0.1 s (0.5 to 99.9 s), ±50 ms; 1 s (100 to 999 s) ±0.5 s Action: (when ON is specificed) after starting, the countdown from the specified time is displayed. (when OFF is specified) displays the elapsed time from starting Ramp timer (withstand test time) Specification range: 0.1 to 99.9 s ramp-up and -down specified separately Specification resolution/accuracy: 0.1 s, ±0.5% of specified value Delay timer (insulation resistance test time) Specification range: 0.1 to 99.9 s Specification resolution/accuracy: 0.1 s, ±0.5% of specified value Action: specify a delay time after testing is set to begin to inhibit decisions during that time ... Non-deterministic interval: 0.5 s ... (Mask time until determination begins during insulation resistance testing) ■ Interfaces Model 3153 Model 3159 EXT I/O Open-collector outputs, active low, max. 30V DC loaded voltage, all signal lines photocoupler-isolated EXT SW START, STOP, SW.EN (panel terminal switch enabled), connection point inputs RS-232C Start-stop synchronization, full duplex, 9600 or 19200 bps GP-IB IEEE 488.2 (1987) compliant Model 3158 Start-stop synchronization, full duplex, 9600 bps ... ■ General Specifications Model 3153 Display Fluorescent display tube (digital display), analog meter Monitor functions Output voltage, detected current, measured resistance Monitor period 2 times per second minimum Model 3159 Model 3158 Output voltage, detected current Operating temperature range 0 to 40 ˚C, 80% RH maximum (non-condensating) Storage temperature range -10 to 50 ˚C, 90% RH maximum (non-condensating) Temperature and humidity range for guaranteed accuracy 23 ± 5 ˚C, 80% RH maximum (non-condensating) (after 10-min. warm-up for 3153, or 5-min. warm-up for 3158 and 3159) Operating environment Indoors, up to 2000m ASL Power supply voltage 100 to 240V AC (installed fuse depends on actual voltage, so specify 100V AC (3159), 120V AC (3159-01), supply voltage when ordering) 220V AC (3159-02), 230V AC (3159-03), 100 to 120V AC: installed fuse 250V T10AL 240V AC (3159-04) 200 to 240V AC: installed fuse 250V T5AL 120V AC (3158-01), 220V AC (3158-03), 230V AC (3158-04), 240V AC (3158-05) Power supply frequency 50 or 60 Hz Max. power consumption 1000 VA 800 VA Dimensions Approx. 320 (W) × 155 (H) × 480 (D) mm Approx. 320 (W) × 155 (H) × 330 (D) mm Approx. 320 (W) × 155 (H) × 263 (D) mm Mass Approx. 18 kg Approx. 18 kg (3159), 20.5 kg (3159-01), 21.5 kg (3159-02 to 3159-04) Approx. 16 kg (3158-01), 18 kg (3158-03 to 3159-05) Supplied accessories 9615 H.V. TEST LEADS (high voltage side and return, one each), POWER CORD, EXTRA FUSE Options 9613 REMOTE CONTROL BOX (SINGLE), 9614 REMOTE CONTROL BOX (DUAL), 9637 RS-232C CABLE (9-pin Dsub to 9-pin Dsub), 9638 RS-232C CABLE (9-pin Dsub to 25-pin Dsub), 9267 SAFETY TEST DATA MANAGEMENT SOFTWARE 3930 HIGH VOLTAGE SCANNER 9151-02 GP-IB CONNECTOR CABLE (2m) 9151-04 GP-IB CONNECTOR CABLE (4m) 9616 WARNING LAMP 7 ■ Six test voltages from 25 to 1000V ■ Stores 10 setting states ■ Easy standards testing with comparator timer function ■ Automatic electrical discharge feature ■ Minimize instability with slow sampling ■ Record changes with analog output Model 3154 DIGITAL MΩ HiTESTER [Measurement Voltage/Range (Auto/Manual range switching)] Measurement voltage Measurement range 25V 50V ±2% rdg. ±5 dgt. ±5% rdg. 19.0 to 200.0 MΩ Unloaded voltage 1000V 0 to 100.0 MΩ 19.0 to 2000 MΩ 100.1 to 2000 MΩ 0 to 999 MΩ 1000 to 4000 MΩ 0.025 MΩ 0.05 MΩ 0.1 MΩ 0.25MΩ 0.5MΩ 2MΩ Rated meas. current 1 to 1.2 mA 0.5 to 0.6 mA Short-circuit current 1.2 mA or less 0.6 mA or less ■ Options 3930 HIGH VOLTAGE SCANNER 9613 REMOTE CONTROL BOX (SINGLE) 9614 REMOTE CONTROL BOX (DUAL) 9151-02 GP-IB CONNECTOR CABLE (2m) 9151-04 GP-IB CONNECTOR CABLE (4m) 9637 RS-232C CABLE (1.8 m) (9pin-9pin/Cross) 9638 RS-232C CABLE (1.8 m) (9pin-25pin/Cross) 9267 SAFETY TEST DATA MANAGEMENT SOFTWARE WITHSTANDING WITHSTANDING WITHSTANDING WITHSTANDING 500V 2.000, 20.00, 200.0 and 4000 MΩ 1 to 1.2 times the measurement voltage 3153 AUTOMATIC INSULATION / WITHSTANDING HiTESTER 3158-01 AC 3158-03 AC 3158-04 AC 3158-05 AC 250V 2.000, 20.00 and 2000 MΩ 0 to 20.00 MΩ Accuracy Min. meas. resistance 100V 2.000, 20.00 and 200.0 MΩ 3159 INSULATION / WITHSTANDING HiTESTER (100V AC) 3159-01 INSULATION / WITHSTANDING HiTESTER (120V AC) 3159-02 INSULATION / WITHSTANDING HiTESTER (220V AC) 3159-03 INSULATION / WITHSTANDING HiTESTER (230V AC) 3159-04 INSULATION / WITHSTANDING HiTESTER (240V AC) ■ Options 9613 REMOTE CONTROL BOX (SINGLE) 9614 REMOTE CONTROL BOX (DUAL) 9616 WARNING LAMP 9637 RS-232C CABLE (1.8 m) (9pin-9pin/Cross) 9638 RS-232C CABLE (1.8 m) (9pin-25pin/Cross) 9267 SAFETY TEST DATA MANAGEMENT SOFTWARE VOLTAGE HiTESTER (120V AC) VOLTAGE HiTESTER (220V AC) VOLTAGE HiTESTER (230V AC) VOLTAGE HiTESTER (240V AC) 9613 ■ Options REMOTE CONTROL BOX (SINGLE) 9613 REMOTE CONTROL BOX (SINGLE) 9614 REMOTE CONTROL BOX (DUAL) 9637 RS-232C CABLE (1.8 m) (9pin-9pin/Cross) 9638 RS-232C CABLE (1.8 m) (9pin-25pin/Cross) 9267 SAFETY TEST DATA MANAGEMENT SOFTWARE 9616 WARNING LAMP (100V AC, 0.1A) 9615 H.V. TEST LEADS HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] 9614 REMOTE CONTROL BOX (DUAL) When using Model 9616 with Models 3153 or 3158, please contact HIOKI for specific details. DISTRIBUTED BY Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : Room 303, Profit Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] All information correct as of Jun. 29, 2007. All specifications are subject to change without notice. 3153E4-76E Printed in Japan