HIGH VOLTAGE INSULATION HiTESTER 3455

HIGH VOLTAGE INSULATION HiTESTER
3455
5KV
Field Measuring Instruments
COMPACT
PERFORMANCE
Test Voltage 250V to 5kV
Insulation Resistance Measurement Up to 5TW
Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
Automatically calculate and display PI (Polarization Index) and DAR (Dielectric
Absorption Ratio)
Step voltage testing, temperature compensation, temperature measurement,
and leakage current display
Data storage and USB interface
CAT IV 600V
2
Wide Range Test Voltage Settings
n Features
Generate Test Voltages Across a Wide Spectrum
The 3455 can generate test voltages ranging from 250 V
to 5 kV. Settings can be made in steps as fine as 25 V. Very
high insulation resistance measurement up to 5 teraohms is
possible.
Ideal for All Insulation Diagnostic Applications
Functions such as automatic calculation and display of PI
(Polarization Index) and DAR (Dielectric Absorption Ratio),
as well as step voltage test, temperature compensation,
temperature measurement, and leakage current display make
the 3455 suitable for a variety of diagnostic applications.
Data Memory Function
The 3455 provides a manual storage function for 100 data
and a logging function for 10 data (360 times). The date and
time of measurement are also recorded.
USB Interface
Easily transfer data to a PC
via the USB interface using
our free PC application
software. The software also
features a convenient report
creation function.
safety regulations for category IV measurements (600
V). A shutter mechanism prevents simultaneous use of
measurement terminals and other terminals. Other safety
features include a voltage measurement
function, high-voltage warning
indicator, and auto discharge function.
Large, Easy to Read Display
The display is backlit and features a
logarithmic bar graph as an analog
type indicator in addition to the digital
readout.
Safety Foremost
The 3455 complies with
n Primary Measurement Functions
z Insulation resistance measurement
Measurement voltage is selectable from 250 V, 500 V, 1.00
kV, 2.50 kV, and 5.00 kV. More finely graded settings are also
possible. When measurement is completed, the unit shows
the insulation resistance value, test voltage (setting and actual
output), leakage current, DAR, PI, and elapsed time.
Insulation resistance measurement display
z Leakage current display
When measuring insulation resistance, the instrument can be
switched to display leakage current. This is possible before,
during, and after measurement.
Display of leakage current during measurement
Actual output
voltage
Insulation
Actual output
voltage
resistance value
> flashes
if less than 1 nA
> flashes if
measurement
range was
exceeded
Elapsed time
leakage current value
STEP 5.0 kV step voltage test
Elapsed time
z Step voltage test
Insulation resistance value
In this type of test, the voltage is gradually raised and the insulation resistance
and leakage current change is measured. Two different step settings are
available: 500 V→ 1 kV → 1.5 kV → 2 kV → 2.5 kV and 1 kV → 2 kV → 3
kV → 4 kV →5 kV. The test time for each step can also be selected.
Measurement
completed
5kV
Step5
4kV
Step4
3kV
Step3
2kV
1kV
Step2
Step1
1
2
3
4
5 minutes
Make Complete Diagnostic Tests of Transformers, Cables, Motors and Other Equipment
z PI and DAR display
Measurement time
PI: Polarization Index
DAR: Dielectric Absorption Ratio
The PI and DAR values which are used as an evaluation standard
for insulation are automatically calculated. With the insulation
resistance measurement start point as reference, the calculation
is performed as follows, using two resistance values obtained at
a prescribed time interval.
Formulas : PI=
DAR 1min/15s =
DAR 1min/30s =
resistance value 10 min after start
resistance value 1 min after start
resistance value 1 min after start
resistance value 15 sec after start
resistance value 1 min after start
resistance value 30 sec after start
Right: first measurement
Left: second measurement
DAR value
Resistance value
Right: first measurement value
Left: second measurement value
Measurement time
First : 1 min ; Second : 10 min
PI value
Resistance value
Right: first measurement 30.0 GW
Left: second measurement 60.0 GW
n Specifications
n Measurement Items:
n Insulation Resistance
Insulation resistance, leakage current, voltage, temperature
Test voltage: 250V to 5.00kV DC
Setting: Preset test voltages: 250 V, 500 V, 1 kV, 2.5 kV, 5 kV
Fine adjustment: possible in 25 V steps between 250 V
and 1 kV and in 100 V steps between 1 and 5 kV
Applies only when the measured resistance is equal to or
higher than the value gained from dividing the test voltage
(setting voltage) by the rated measurement current. Output
voltage is not guaranteed if measured resistance is lower than
Measurement current: [test voltage/rated measurement current].
Test voltage
250V to 1.00kV
1.10kV to 2.50kV
2.60kV to 5.00kV
Measurement current
1mA
0.5mA
0.25mA
Rated measurement current tolerance: -0%, +10%
Short-circuit current: 2 mA or less
Output voltage
Monitor function: Display range: 0 to 999 V, 0.98 to 5.50 kV
Monitor accuracy: ± 5% rdg. ± 5 dgt.
Measurement range:
Test voltage
Measurement range
250 V
0.00MW to 250GW
500 V
0.00MW to 500GW
1 kV
0.00MW to 1.00TW
2.5 kV
0.00MW to 2.50TW
5 kV
0.00MW to 5.00TW
Resistance range:
(auto range)
Resistance range
10MW
100MW
1000MW
10GW
100GW
1000GW
5TW
Measurement range
0.00MW to 9.99MW
9.0MW to 99.9MW
90MW to 999MW
0.90GW to 9.99GW
9.0GW to 99.9GW
90GW to 999GW
0.90TW to 5.00TW
Resistance range accuracy
±30%rdg. ±50dgt.
Insulation resistance
500GΩ
250GΩ
[Test voltage / Resistance measurable at 100 nA]
to 500 GW
501GW to 5.00TW
Accuracy
±5%rdg.±5dgt.
±20%rdg.±5dgt.
±30%rdg.±50dgt.
(temperature and humidity range for guaranteed accuracy 0 to 28˚C, max. 90%rh, no condensation)
Response time: 15s max. (from measurement start to until guaranteed
accuracy display, no averaging)
n Leakage Current (current measurement with test voltage being generated)
Measurement range: 1.00nA to 1.20mA
Current range
and accuracy:
Current range
10nA
100nA
1000nA
10µA
100µA
1mA
Measurement range
1.00nA to 9.99nA
9.0nA to 99.9nA
90nA to 999nA
0.90µA to 9.99µA
9.0µA to 99.9µA
90µA to 999µA,
0.90mA to 1.20mA
Accuracy
±15%rdg. ±1nA
± 15%rdg. ±5dgt.
±2.5%rdg. ±5dgt.
±2.5%rdg. ±5dgt.
±2.5%rdg. ±5dgt.
±2.5%rdg. ±5dgt.
(auto range, temperature and humidity range for guaranteed accuracy 0 to 28˚C, max. 90%rh, no condensation)
Response time: 15 s max. (from measurement start to until guaranteed
accuracy display, no averaging)
(temperature and humidity range for guaranteed
n Voltage
accuracy 23±5 ˚C, max. 90%rh, no condensation)
Measurement range: DC ±50V to ±1.00kV , AC 50V to 750V
Frequency: DC/ 50Hz/ 60Hz
Accuracy: ±5%rdg. ±5dgt.
(for DC, absolute values of 1.01 kV and above are out
of guaranteed accuracy range)
Input impedance: Approx. 10 MW
Response time: 3 s or less
n Temperature
Measurement range
–10.0˚C to –0.1˚C
0.0˚C to 40.0˚C
40.1˚C to 70.0˚C
Accuracy
±1.5˚C
±1.0˚C
±1.5˚C
±20%rdg. ±5dgt.
100GΩ
50.0GΩ
When using the temperature sensor 9631-05, accuracy is
25.0GΩ
10.0GΩ
guaranteed only for 0.0 - 40.0 ˚C range
5.00GΩ
Response time: Approx. 100 s, including response of temperature
sensor models 9631-01 to 9631-05
(reference value, time until a 90% value of a
temperature change is shown)
2.50GΩ
1.00GΩ
±5%rdg. ±5dgt.
100MΩ
10.0MΩ
1.00MΩ
0.00MΩ
Measurement range
Up to [Test voltage / Resistance measurable at
100 nA]
Measurement range
and Accuracy:
5.00TΩ
2.50TΩ
1.00TΩ
Accuracy:
250V
500V
1kV
2.5kV
Test voltage (setting value)
5kV
3
4
n General Specifications
n Specifications
n Insulation Diagnosis
Temperature compensation: Result converted to insulation resistance at reference
temperature. 10 different temperature compensation
tables can be selected, according to insulation material
of measurement object. Reference temperature: 20˚C
or 40˚C by default, setting can be changed.
PI/DAR display: PI: Polarization Index
DAR: Dielectric Absorption Ratio
After insulation resistance measurement has started,
calculation is performed using two resistance values
obtained at prescribed time intervals.
Step voltage test: Measurement of insulation resistance while raising
voltage at specific intervals. Two voltage step patterns
can be selected.
STEP 2.5kV : 500V→1kV→1.5kV→2kV→2.5kV
STEP 5kV : 1kV→2kV→3kV→4kV→5kV
Voltage application time for each step: 30 s./1/2/5 m.
n Supplementary Functions
Data memory: Manual recording: store up to 100 data , Data type:
standard measurement data/ temperature compensation
data/step voltage test data, Data logging: store
measurement value at preset intervals, available for
insulation resistance measurement only, Number of
data: 10, Number of logging instances: 360 times per
data, Recording interval: 15/30 s /1/2/5m, Data content:
date, time, measurement interval, temperature, set
voltage, actual output voltage × times, resistance ×
times, Additional functions: write mode, read mode, all
clear, selective clear, overwrite
Communication: Interface: USB ver 2.0 (full speed)
PC application software: transfer of memory data from
3455 to computer, data display, create graph,
3455 items that can be set/changed from computer:
date, time, PI time, step time for step voltage test,
report function
Other items: Temperature/humidity value input, timer, elapsed time
display, clock, averaging, data hold, auto discharge,
active voltage warning indication, hot conductor
warning indication, LCD backlight, auto power-off,
buzzer
TEST LEAD 9750
ALLIGATOR CLIP 9751
BATTERY PACK 9459
TEMPERATURE SENSOR 9631-01
Molded plastic, thermistor type
Operating temp. , humidity: 0 to 40˚C, max90%rh (no condensation)
10 to 40˚C, max. 80%rh for battery pack charging
Storage temp. , humidity: -10 to 50˚C, max 90%rh (no condensation)
Guaranteed accuracy period: 1 year
Operating environment: Indoors, up to 2000 m ASL
Measurement method: DC voltage application method (insulation resistance),
average value rectification method (voltage)
A/D conversion: Double integral method
Display: LCD, with backlight
Indication: Numeric: up to 999, Bar graph: insulation resistance
only, range 0 to 1 TΩ
Display update rate: Insulation resistance/leakage current: 1 time/second
(0.25 times/second when using averaging)
Output voltage monitor: 2 times/second
Voltage measurement: 4 times/second
Temperature measurement: 1 time/second
Power supply: LR6 (AA) alkaline battery × 6
Battery pack 9459: 7.2 V DC (rechargeable, Ni-MH)
AC adapter 9753: rated input voltage 100 to 240 V
AC, rated output15VA
Max. power consumption: 15 VA (using AC adapter), 6 VA (using batteries or battery
pack) (5 kV generated, +/- terminals open, backlight off)
Continuous operation time: approx. 5 hours (with alkaline batteries)
(reference value) approx. 9 hours (with battery pack 9459 )
Max. input voltage: AC750Vrms, DC1000V
Max.rated voltage to ground: 600Vrms(CATIV) , 1000Vrms (CATIII)
Withstand voltage: 6880 V AC, 15 sec.
Dimensions & Mass: 260(W) × 250.6(H) × 119.5(D) mm, 2.8kg
Applicable standards: Safety: EN61010-1:2001, EN61010-031:2002
EMC:EN61326:1997+A1:1998+A2:2001
EN61000-3-2:2000
EN61000-3-3:1995+A1:2001
Accessories: TEST LEAD (RED) 9750-01 × 1, TEST LEAD
(BLACK) 9750-02 × 1, TEST LEAD (BLUE,
GUARD) 9750-03 × 1, ALLIGATOR CLIP (RED)
9751-01 × 1, ALLIGATOR CLIP (BLACK) 975102 × 1, ALLIGATOR CLIP (BLUE, GUARD) 975103 × 1, LR6 (size AA) battery × 6, USB CABLE × 1,
CD-R (Data Analysis Software for 3455) × 1
Options: TEMPERATURE SENSOR 9631-01
(Thermistor, Molded type, Approx. 1 m)
TEMPERATURE SENSOR 9631-05
(Thermistor, Molded type, Approx. 6 cm)
TEST LEAD 9750-11 (Red, Approx. 10 m)
TEST LEAD 9750-12 (Black, Approx. 10 m)
TEST LEAD 9750-13 (Blue, Approx. 10 m, GUARD)
BATTERY PACK 9459
AC ADAPTER 9753
TEMPERATURE SENSOR 9631-05
Molded plastic, thermistor type
AC ADAPTER 9753
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong
Road, Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: [email protected]
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: [email protected]
DISTRIBUTED BY
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
Room A-3206, Victory PlazaServices Center, No.103,
Tiyuxi Road, Guangzhou, P.R.China POSTCODE:510620
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
All information correct as of Jul. 13, 2009. All specifications are subject to change without notice.
3455E4-97M-05K
Printed in Japan