HIGH VOLTAGE INSULATION HiTESTER 3455 5KV Field Measuring Instruments COMPACT PERFORMANCE Test Voltage 250V to 5kV Insulation Resistance Measurement Up to 5TW Measure insulation of high-voltage equipment (such as transformers, cables, and motors) Automatically calculate and display PI (Polarization Index) and DAR (Dielectric Absorption Ratio) Step voltage testing, temperature compensation, temperature measurement, and leakage current display Data storage and USB interface CAT IV 600V 2 Wide Range Test Voltage Settings n Features Generate Test Voltages Across a Wide Spectrum The 3455 can generate test voltages ranging from 250 V to 5 kV. Settings can be made in steps as fine as 25 V. Very high insulation resistance measurement up to 5 teraohms is possible. Ideal for All Insulation Diagnostic Applications Functions such as automatic calculation and display of PI (Polarization Index) and DAR (Dielectric Absorption Ratio), as well as step voltage test, temperature compensation, temperature measurement, and leakage current display make the 3455 suitable for a variety of diagnostic applications. Data Memory Function The 3455 provides a manual storage function for 100 data and a logging function for 10 data (360 times). The date and time of measurement are also recorded. USB Interface Easily transfer data to a PC via the USB interface using our free PC application software. The software also features a convenient report creation function. safety regulations for category IV measurements (600 V). A shutter mechanism prevents simultaneous use of measurement terminals and other terminals. Other safety features include a voltage measurement function, high-voltage warning indicator, and auto discharge function. Large, Easy to Read Display The display is backlit and features a logarithmic bar graph as an analog type indicator in addition to the digital readout. Safety Foremost The 3455 complies with n Primary Measurement Functions z Insulation resistance measurement Measurement voltage is selectable from 250 V, 500 V, 1.00 kV, 2.50 kV, and 5.00 kV. More finely graded settings are also possible. When measurement is completed, the unit shows the insulation resistance value, test voltage (setting and actual output), leakage current, DAR, PI, and elapsed time. Insulation resistance measurement display z Leakage current display When measuring insulation resistance, the instrument can be switched to display leakage current. This is possible before, during, and after measurement. Display of leakage current during measurement Actual output voltage Insulation Actual output voltage resistance value > flashes if less than 1 nA > flashes if measurement range was exceeded Elapsed time leakage current value STEP 5.0 kV step voltage test Elapsed time z Step voltage test Insulation resistance value In this type of test, the voltage is gradually raised and the insulation resistance and leakage current change is measured. Two different step settings are available: 500 V→ 1 kV → 1.5 kV → 2 kV → 2.5 kV and 1 kV → 2 kV → 3 kV → 4 kV →5 kV. The test time for each step can also be selected. Measurement completed 5kV Step5 4kV Step4 3kV Step3 2kV 1kV Step2 Step1 1 2 3 4 5 minutes Make Complete Diagnostic Tests of Transformers, Cables, Motors and Other Equipment z PI and DAR display Measurement time PI: Polarization Index DAR: Dielectric Absorption Ratio The PI and DAR values which are used as an evaluation standard for insulation are automatically calculated. With the insulation resistance measurement start point as reference, the calculation is performed as follows, using two resistance values obtained at a prescribed time interval. Formulas : PI= DAR 1min/15s = DAR 1min/30s = resistance value 10 min after start resistance value 1 min after start resistance value 1 min after start resistance value 15 sec after start resistance value 1 min after start resistance value 30 sec after start Right: first measurement Left: second measurement DAR value Resistance value Right: first measurement value Left: second measurement value Measurement time First : 1 min ; Second : 10 min PI value Resistance value Right: first measurement 30.0 GW Left: second measurement 60.0 GW n Specifications n Measurement Items: n Insulation Resistance Insulation resistance, leakage current, voltage, temperature Test voltage: 250V to 5.00kV DC Setting: Preset test voltages: 250 V, 500 V, 1 kV, 2.5 kV, 5 kV Fine adjustment: possible in 25 V steps between 250 V and 1 kV and in 100 V steps between 1 and 5 kV Applies only when the measured resistance is equal to or higher than the value gained from dividing the test voltage (setting voltage) by the rated measurement current. Output voltage is not guaranteed if measured resistance is lower than Measurement current: [test voltage/rated measurement current]. Test voltage 250V to 1.00kV 1.10kV to 2.50kV 2.60kV to 5.00kV Measurement current 1mA 0.5mA 0.25mA Rated measurement current tolerance: -0%, +10% Short-circuit current: 2 mA or less Output voltage Monitor function: Display range: 0 to 999 V, 0.98 to 5.50 kV Monitor accuracy: ± 5% rdg. ± 5 dgt. Measurement range: Test voltage Measurement range 250 V 0.00MW to 250GW 500 V 0.00MW to 500GW 1 kV 0.00MW to 1.00TW 2.5 kV 0.00MW to 2.50TW 5 kV 0.00MW to 5.00TW Resistance range: (auto range) Resistance range 10MW 100MW 1000MW 10GW 100GW 1000GW 5TW Measurement range 0.00MW to 9.99MW 9.0MW to 99.9MW 90MW to 999MW 0.90GW to 9.99GW 9.0GW to 99.9GW 90GW to 999GW 0.90TW to 5.00TW Resistance range accuracy ±30%rdg. ±50dgt. Insulation resistance 500GΩ 250GΩ [Test voltage / Resistance measurable at 100 nA] to 500 GW 501GW to 5.00TW Accuracy ±5%rdg.±5dgt. ±20%rdg.±5dgt. ±30%rdg.±50dgt. (temperature and humidity range for guaranteed accuracy 0 to 28˚C, max. 90%rh, no condensation) Response time: 15s max. (from measurement start to until guaranteed accuracy display, no averaging) n Leakage Current (current measurement with test voltage being generated) Measurement range: 1.00nA to 1.20mA Current range and accuracy: Current range 10nA 100nA 1000nA 10µA 100µA 1mA Measurement range 1.00nA to 9.99nA 9.0nA to 99.9nA 90nA to 999nA 0.90µA to 9.99µA 9.0µA to 99.9µA 90µA to 999µA, 0.90mA to 1.20mA Accuracy ±15%rdg. ±1nA ± 15%rdg. ±5dgt. ±2.5%rdg. ±5dgt. ±2.5%rdg. ±5dgt. ±2.5%rdg. ±5dgt. ±2.5%rdg. ±5dgt. (auto range, temperature and humidity range for guaranteed accuracy 0 to 28˚C, max. 90%rh, no condensation) Response time: 15 s max. (from measurement start to until guaranteed accuracy display, no averaging) (temperature and humidity range for guaranteed n Voltage accuracy 23±5 ˚C, max. 90%rh, no condensation) Measurement range: DC ±50V to ±1.00kV , AC 50V to 750V Frequency: DC/ 50Hz/ 60Hz Accuracy: ±5%rdg. ±5dgt. (for DC, absolute values of 1.01 kV and above are out of guaranteed accuracy range) Input impedance: Approx. 10 MW Response time: 3 s or less n Temperature Measurement range –10.0˚C to –0.1˚C 0.0˚C to 40.0˚C 40.1˚C to 70.0˚C Accuracy ±1.5˚C ±1.0˚C ±1.5˚C ±20%rdg. ±5dgt. 100GΩ 50.0GΩ When using the temperature sensor 9631-05, accuracy is 25.0GΩ 10.0GΩ guaranteed only for 0.0 - 40.0 ˚C range 5.00GΩ Response time: Approx. 100 s, including response of temperature sensor models 9631-01 to 9631-05 (reference value, time until a 90% value of a temperature change is shown) 2.50GΩ 1.00GΩ ±5%rdg. ±5dgt. 100MΩ 10.0MΩ 1.00MΩ 0.00MΩ Measurement range Up to [Test voltage / Resistance measurable at 100 nA] Measurement range and Accuracy: 5.00TΩ 2.50TΩ 1.00TΩ Accuracy: 250V 500V 1kV 2.5kV Test voltage (setting value) 5kV 3 4 n General Specifications n Specifications n Insulation Diagnosis Temperature compensation: Result converted to insulation resistance at reference temperature. 10 different temperature compensation tables can be selected, according to insulation material of measurement object. Reference temperature: 20˚C or 40˚C by default, setting can be changed. PI/DAR display: PI: Polarization Index DAR: Dielectric Absorption Ratio After insulation resistance measurement has started, calculation is performed using two resistance values obtained at prescribed time intervals. Step voltage test: Measurement of insulation resistance while raising voltage at specific intervals. Two voltage step patterns can be selected. STEP 2.5kV : 500V→1kV→1.5kV→2kV→2.5kV STEP 5kV : 1kV→2kV→3kV→4kV→5kV Voltage application time for each step: 30 s./1/2/5 m. n Supplementary Functions Data memory: Manual recording: store up to 100 data , Data type: standard measurement data/ temperature compensation data/step voltage test data, Data logging: store measurement value at preset intervals, available for insulation resistance measurement only, Number of data: 10, Number of logging instances: 360 times per data, Recording interval: 15/30 s /1/2/5m, Data content: date, time, measurement interval, temperature, set voltage, actual output voltage × times, resistance × times, Additional functions: write mode, read mode, all clear, selective clear, overwrite Communication: Interface: USB ver 2.0 (full speed) PC application software: transfer of memory data from 3455 to computer, data display, create graph, 3455 items that can be set/changed from computer: date, time, PI time, step time for step voltage test, report function Other items: Temperature/humidity value input, timer, elapsed time display, clock, averaging, data hold, auto discharge, active voltage warning indication, hot conductor warning indication, LCD backlight, auto power-off, buzzer TEST LEAD 9750 ALLIGATOR CLIP 9751 BATTERY PACK 9459 TEMPERATURE SENSOR 9631-01 Molded plastic, thermistor type Operating temp. , humidity: 0 to 40˚C, max90%rh (no condensation) 10 to 40˚C, max. 80%rh for battery pack charging Storage temp. , humidity: -10 to 50˚C, max 90%rh (no condensation) Guaranteed accuracy period: 1 year Operating environment: Indoors, up to 2000 m ASL Measurement method: DC voltage application method (insulation resistance), average value rectification method (voltage) A/D conversion: Double integral method Display: LCD, with backlight Indication: Numeric: up to 999, Bar graph: insulation resistance only, range 0 to 1 TΩ Display update rate: Insulation resistance/leakage current: 1 time/second (0.25 times/second when using averaging) Output voltage monitor: 2 times/second Voltage measurement: 4 times/second Temperature measurement: 1 time/second Power supply: LR6 (AA) alkaline battery × 6 Battery pack 9459: 7.2 V DC (rechargeable, Ni-MH) AC adapter 9753: rated input voltage 100 to 240 V AC, rated output15VA Max. power consumption: 15 VA (using AC adapter), 6 VA (using batteries or battery pack) (5 kV generated, +/- terminals open, backlight off) Continuous operation time: approx. 5 hours (with alkaline batteries) (reference value) approx. 9 hours (with battery pack 9459 ) Max. input voltage: AC750Vrms, DC1000V Max.rated voltage to ground: 600Vrms(CATIV) , 1000Vrms (CATIII) Withstand voltage: 6880 V AC, 15 sec. Dimensions & Mass: 260(W) × 250.6(H) × 119.5(D) mm, 2.8kg Applicable standards: Safety: EN61010-1:2001, EN61010-031:2002 EMC:EN61326:1997+A1:1998+A2:2001 EN61000-3-2:2000 EN61000-3-3:1995+A1:2001 Accessories: TEST LEAD (RED) 9750-01 × 1, TEST LEAD (BLACK) 9750-02 × 1, TEST LEAD (BLUE, GUARD) 9750-03 × 1, ALLIGATOR CLIP (RED) 9751-01 × 1, ALLIGATOR CLIP (BLACK) 975102 × 1, ALLIGATOR CLIP (BLUE, GUARD) 975103 × 1, LR6 (size AA) battery × 6, USB CABLE × 1, CD-R (Data Analysis Software for 3455) × 1 Options: TEMPERATURE SENSOR 9631-01 (Thermistor, Molded type, Approx. 1 m) TEMPERATURE SENSOR 9631-05 (Thermistor, Molded type, Approx. 6 cm) TEST LEAD 9750-11 (Red, Approx. 10 m) TEST LEAD 9750-12 (Black, Approx. 10 m) TEST LEAD 9750-13 (Blue, Approx. 10 m, GUARD) BATTERY PACK 9459 AC ADAPTER 9753 TEMPERATURE SENSOR 9631-05 Molded plastic, thermistor type AC ADAPTER 9753 HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] DISTRIBUTED BY Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : Room A-3206, Victory PlazaServices Center, No.103, Tiyuxi Road, Guangzhou, P.R.China POSTCODE:510620 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] All information correct as of Jul. 13, 2009. All specifications are subject to change without notice. 3455E4-97M-05K Printed in Japan