CURRENT PROBE CT6700/CT6701 CURRENT PROBE CT6700/CT6701 Clamp sensor 10× the sensitivity of conventional probes CT6701 DC to 120MHz, 5A MAX CT6700 DC to 50MHz, 5A MAX Observe low current waveforms of 1 mA Connection image A separate power supply is required when using the CT6700/CT6701. Current probes are key to the successful design of electrical devices, medical instruments, and electronic parts. In combination with an oscilloscope or HIOKI MEMORY HiCORDER, probes are ideal for measuring currents with high accuracy and wide bandwidths, making them indispensable tools for evaluating current consumption and control current. In recent years, customers are seeking current probes with high sensitivity to increase the accuracy of design and verification. To further enhance our rich lineup of current probes, HIOKI now delivers two new, highly-sensitive current probes that can measure low level currents from 1 mA. 2 Analyze currents in finer detail 10x Sensitivity Clearly observe even 1 mA waveforms The output rate for the CT6700/ CT6701 is 1 V/A. When 1 mA is measured, it can output 1 mV. This is ten times the sensitivity of our legacy*1 models. Now, even 1 mA waveforms can be clearly captured.*2 CT6701 *1: *2: CURRENT PROBE 3273-50/3276 Output rate 0.1 V/A, 30 A MAX When measuring low level cur rents, in addition to noise from the current probe itself, there is also influence from external noise or noise from the connected meter. Legacy models Input: 1 mAp-p, 1 kHz, sine wave Oscilloscope: Bandwidth 2 GHz (Bandwidth limit 20 MHz), 1 mV/div Improved S/N Ratio: Measure even the extremely low current signals buried in noise CT6700 Legacy models Oscilloscope usage range: 10 mV/div Oscilloscope usage range: 1 mV/div Input: 20 mAp-p, 1 kHz, sine wave Oscilloscope: Bandwidth 2 GHz (No bandwidth limitation), 10 mV/div CT6700 Legacy models Oscilloscope usage range: 10 mV/div Oscilloscope usage range: 1 mV/div Input: 20 mAp-p, 1 kHz, square wave Oscilloscope: Bandwidth 2 GHz (No bandwidth limitation), 10 mV/div Low level currents can only be clearly captured by instruments that deliver a good S/N ratio. Because the output rate is n o w 1 V/A (10 x t h a n t h a t of legacy models), you can observe waveforms even if the oscilloscope's range is 1/10 than that of legacy products. By allowing for range selection with leeway for the S/N ratio, you can clearly observe signals that previously were buried in noise. 3 Streamlining Measurement Slim Sensor Warning Features OVERLOAD Warning JAW UNLOCKED Warning Threshold Sensor (Actual size) The sensor has been redesigned, making it more compact and easier to handle, in a form that fits perfectly in your hand. The ergonomic structure is ideal for situations with complex electrical circuit design and wiring. Automatic Zero-Adjustment and Demagnetization in One Button Current T he war ning lamp will flash if a current exceeding the rating is input. "JAW UNLOCKED" will display and the warning lamp will light up if the sensor is unlocked when clamped. One-touch Disconnection from the BNC Terminal With the CT6700/CT6701, you can automatically perform the zero-adjustment, which must be done before use, by pressing a single button. By pressing and holding the button for demagnetization, you can cancel an offset margi n of er ror af ter measuring a large current. The BNC connector does not need to be rotated when connecting to an oscilloscope or recorder. Insert the connector until it automatically locks into place. To disconnect it, just pull the unlock lever toward you. Built for Demanding Applications Measure the current of automobile electronic parts Evaluate the current characteristics of circuit components Observe control currents, which flow through automobile electronic parts such as compact motors, on the mA order. W he n t e st i ng for t he cor re ct functioning of built-in circuits, you can reliably catch noise waveforms with a wide frequency bandwidth. Compact motors Solenoid valves Relay control current Condenser current Evaluate high-speed switching elements Measure switching elements that drive devices such as LEDs and motors, including the ON/OFF response of semiconductors that operate at high speeds, ripple waveforms, and switching loss. Waveform of an inverter when switched ON Evaluation of LED light driving circuits Specifications (Product warranty period : 1 Year) CT6700 CT6701 Frequency range DC to 50 MHz (-3dB) (Refer to the frequency characteristics graph below.) DC to 120 MHz (-3dB) (Refer to the frequency characteristics graph below.) Rise time (10% to 90%) 7.0 ns or less 2.9 ns or less Maximum rated current 5 A rms (DC, and sine wave) (Refer to the frequency derating properties graph below.) Maximum peak current ±7.5 A peak (non-continuous) Diameter of measurable conductors 5 mm dia. or less Measurable conductors Insulated conductors Output voltage rate 1 V/A Amplitude accuracy ±1%rdg. typical ±1 mV, ±3.0%rdg. ±1 mV (DC, 45 to 66 Hz sine wave, 0 to 5 A rms) Output resistance 50 Ω ±10% (DC) Noise 60 μA rms typical, 75 μA rms max (for 30 MHz band measuring instrument) Temperature coefficient for sensitivity ±2%rdg. or less (After automatic zero-adjustment with 50 Hz 5 A rms input, except at 23±5°C) Maximum rated power 3.2 VA (with continuous maximum input) Supply voltage ±12 V Operating temperature and humidity range 0 to +40°C, 80% RH or less (no condensation) Storage temperature and humidity range -10 to +50°C, 80% RH or less (no condensation) Location for use Indoor, pollution degree 2, altitude up to 2000 m Effect of external magnetic fields 20 mA max - DC and 60 Hz, magnetic field of 400 A/m Effect of radiated radio-frequency electromagnetic field ±10 mA max (at 3 V/m) 5 mA max - DC and 60 Hz, magnetic field of 400 A/m Effect of conducted radio-frequency electromagnetic field ±10 mA max (at 3 V) DEMAG/AUTO ZERO function Demagnetization, automatic zero-adjustment JAW UNLOCKED detection LED lights up when the opening mechanism of the sensor head is unlocked. OVERLOAD detection LED flashes to warn that the input is in excess of ratings Accuracy warranty period 1 year (Opening/closing up to 10,000 times) Cord lengths Sensor cord: 1.5 m (4.92 ft), Power cord: 1.0 m (3.28 ft) External dimensions and mass Sensor: 155 mm (6.10 in)W × 18 mm (0.71 in)H × 26 mm (1.02 in)D, Terminator: 29 mm (1.14 in)W × 83 mm (3.27 in)H × 40 mm (1.57 in)D mm, Mass: 250 g (8.8 oz) Accessories Instruction manual, Carrying case -10 -20 -30 1 Gain [dB] 100 10k 1M 0.1 4 3 0.01 2 0 100M 1G Frequency[Hz] Frequency characteristics: CT6701 (typ.) 10 0 -10 -20 -30 -40 5 Input impedance: CT6700 (typ.) 1 1 Maximum input current [A] -40 Input impedance [Ω] 0 Frequency derating: CT6700 (typ.) 6 100 1k 10k 100k 1M 10M 100M 1G Frequency[Hz] Frequency derating: CT6701 (typ.) 6 0.001 Input impedance [Ω] Gain [dB] 10 Maximum input current [A] Frequency characteristics: CT6700 (typ.) 5 100 1k 10k 100k 1M 10M 100M 1G Frequency[Hz] Input impedance: CT6701 (typ.) 1 0.1 4 3 0.01 2 1 1 10k 1M 17 100M 1G Frequency[Hz] 0 100 1k 10k 100k 83 1M 10M 100M 1G Frequency[Hz] 0.001 100 1k 10k 100k 1M 10M 100M 1G Frequency[Hz] Lineup and options 29 Top 100 18 CURRENT PROBE CT6700 DC to 50MHz, 5A MAX 155 A separate power supply is required when using the CT6700/CT6701. 40 Side Diameter of measurable conductors: φ5 26 CURRENT PROBE CT6701 DC to 120MHz, 5A MAX Unit: mm POWER SUPPLY 3269 Supports up to 4 current probes *About the 3272 Power Supply When using CT6700/CT6701 and a different sensor simultaneously, please note that you may not be able to use two sensors at once depending on the current consumption. Please check the specifications of the corresponding sensor. POWER SUPPLY 3272 Supports 2 current probes Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. HIOKI (Shanghai) SALES & TRADING CO., LTD. TEL +86-21-63910090 FAX +86-21-63910360 http://www.hioki.cn / E-mail: [email protected] DISTRIBUTED BY HIOKI INDIA PRIVATE LIMITED TEL +91-124-6590210 FAX +91-124-6460113 HEADQUARTERS E-mail: [email protected] 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 FAX +81-268-28-0568 HIOKI SINGAPORE PTE. LTD. http://www.hioki.com / E-mail: [email protected] TEL +65-6634-7677 FAX +65-6634-7477 E-mail: [email protected] HIOKI USA CORPORATION HIOKI KOREA CO., LTD. TEL +1-609-409-9109 FAX +1-609-409-9108 TEL +82-42-936-1281 FAX +82-42-936-1284 http://www.hiokiusa.com / E-mail: [email protected] E-mail: [email protected] All information correct as of Dec. 11, 2014. All specifications are subject to change without notice. CT6700E2-4ZM Printed in Japan