Series AMEL10-MAZ

Click on Series name for product info on aimtec.com
Series AMEL10-MAZ
10 Watt | AC-DC / DC-DC Converter
FEATURES:




I/O Isolation 4000VAC
Operating Temp: -40oC to +70oC
Over load, Over Voltage, Short Circuit Protection
Up to 80% efficiency


Energy Star compliant
Ultra small package
Models
Single output
Model
CB
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max Output
wattage
(W)
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive
load
(µF)
Efficiency
(%)
AMEL10-3.3SMAZ
90-264/47-440
130-370
9.9
3.3
3.00
2200
AMEL10-5SMAZ
90-264/47-440
130-370
10
5
2.00
1000
AMEL10-12SMAZ
90-264/47-440
130-370
10
12
0.84
680
AMEL10-15SMAZ
90-264/47-440
130-370
10
15
0.67
470
AMEL10-24SMAZ
90-264/47-440
130-370
10
24
0.42
470
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL10-5SMAZ-ST)
75
77
79
80
80
Models
Asymmetric Dual output
Model
AMEL10-3.35DMAZ
AMEL10-3.312DMAZ
AMEL10-3.315DMAZ
AMEL10-3.324DMAZ
AMEL10-512DMAZ
AMEL10-515DMAZ
AMEL10-524DMAZ
AMEL10-1215DMAZ
AMEL10-1224DMAZ
AMEL10-1524DMAZ
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
130-370
130-370
130-370
130-370
130-370
130-370
130-370
130-370
130-370
130-370
(W)
Output
Voltage
(V)
Rated
Output
Current (A)
Maximum
capacitive
load
(µF)
Efficiency
(%)
7.9
8
8
8
8
8
8
8
9
9
3.3/5
3.3/12
3.3/15
3.3/24
5/12
5/15
5/24
12/15
12/24
15/24
0.9/1.0
0.9/0.41
0.9/0.33
0.9/0.2
0.6/0.41
0.6/0.33
0.6/0.2
0.25/0.33
0.25/0.25
0.2/0.25
680
680
680
680
470
470
470
330
330
330
74
77
76
75
75
77
72
76
78
79
Max Output
wattage
AMEL10-3.3N5DMAZ
90-264/47-440
130-370
7.3
-3.3/5
-0.7/1.0
680
AMEL10-3.3N12DMAZ
90-264/47-440
130-370
8
-3.3/12
-0.9/0.41
680
AMEL10-3.3N15DMAZ
90-264/47-440
130-370
8
-3.3/15
-0.9/0.33
680
AMEL10-5N5DMAZ
90-264/47-440
130-370
8
-5/5
-0.6/1
680
AMEL10-5N12DMAZ
90-264/47-440
130-370
8
-5/12
-0.6/0.41
470
AMEL10-5N15DMAZ
90-264/47-440
130-370
8
-5/15
-0.6/0.33
470
AMEL10-12N12DMAZ
90-264/47-440
130-370
8
-12/12
-0.25/0.41
470
AMEL10-12N15DMAZ
90-264/47-440
130-370
8
-12/15
-0.25/0.33
330
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL10-5SMAZ-ST)
74
75
75
74
74
74
76
75
*Output power must not exceed the listed values.
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms (cold start)
Leakage current
External fuse
www.aimtec.com
F 052e R8.U
Conditions
Typical
115VAC
230VAC
115VAC
230VAC
0.23
0.15



1
slow blow type
Tel: +1 514 620 2722
1 of 6
Maximum
10
20
0.25
Units
A
A
A
A
mA
A
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL10-MAZ
10 Watt | AC-DC / DC-DC Converter
Input Specifications (continued)
Parameters
Input dissipation
Start up time
Conditions
Typical
No Load
≤0.2
50
Conditions
Typical
Maximum
Units
W
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Load regulation (dual output)
Transient recovery time
Transient response deviation
0-100% load
Unbalanced (0-100% load)
25% load step
3.3 & 5V models
12, 15 & 24V models
115VAC
230VAC
Ripple & Noise*
Hold-up time (min)
Maximum
±2
±1
±2
±3
500
±2
75
100
10
25
Units
%
%
%
%
µs
% of Vout
mV p-p
ms
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) & 4.7µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation resistance
Isolation capacitor
Typical
60 sec, 1.2mA
Rated
Units
4000
VAC
MΩ
pF
>1000
2200
General Specifications
Parameters
Switching frequency
Protection class
Over load protection
Over voltage protection
Short circuit protection
Short circuit restart
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
100% load
Maximum
65
Class II
150
Zener Diode Clamp
Continuous
Auto recovery
-40 to +70
Auto recovery, Foldback
See derating table
Units
KHz
%
oC
100
-45 to +95
±0.02
Free air convection
Non condensing
20 ~ 95
Plastic resin + Fiberglass (flammability to UL 94V-0)
70
2.22 x 1.21 x 0.99 inches
56.48 x 30.86 x 25.10mm
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
oC
oC
% / oC
% RH
g
Environment Approval
Test
Shock
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
www.aimtec.com
F 052e R8.U
Conditions
Half sine wave
5gn
30 ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine
1mm
3g
10-100Hz, speed 0.05Hz/s
Tel: +1 514 620 2722
2 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL10-MAZ
10 Watt | AC-DC / DC-DC Converter
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Information Technology Equipment
Information Technology Equipment
Standards
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No.
601.1-M90
EN 60950-1:2006+A11:2009
EN55022, class B
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 2
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 2
IEC 61000-4-8
IEC 61000-4-11
UL 60950-1:2007
CAN/CSA-C22.2 No.60950-1-07
Additional Surge Protective Circuitry
The AMEL10-MAZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However
greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal
Oxide Varistor) device example TVR10471KSY to the N / L input lines 2KV surge protection or greater, can be achieved.
MOV PN
Vrms
V
Vdc
V
Wmax (2ms)
J
Pmax
W
TVR10471KSY
300
385
70
0.4
Pin Out Specifications
Pin
Single
Dual positive
Dual negative/positive
1
2
3
4
5
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
AC Input (N)
AC Input (L)
+V1 Output
Common
+V2 Output
AC Input (N)
AC Input (L)
+V1 Output
Common
-V2 Output
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL10-MAZ
10 Watt | AC-DC / DC-DC Converter
Dimensions
56.46
(2.22)
45.72
(1.80)
3
1
4
3
1
4
2
5
5.37
(0.21)
2
5.37
(0.21)
5
DIV: 10.00 (0.40)
5Ø 1.0 (Ø 0.04)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002)
Pin Pitch Tolerance ±0.35 (±0.014)
1.05
(0.04)
Derating
Free Air Convection
50°C
Output Power (%)
100
80
60
Safe Operating Area
40
20
70°C
0
- 40
- 20
0
20
40
60
80
100
Ambient Temperature º C
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL10-MAZ
10 Watt | AC-DC / DC-DC Converter
Derating (Dual Output Models)
Free Air Convection
40°C
Output Power (%)
100
80
60
Safe Operating Area
40
20
70°C
0
- 40
- 20
0
20
40
60
80
100
Ambient Temperature º C
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL10-MAZ
10 Watt | AC-DC / DC-DC Converter
Dimensions of Optional ST Mounting Plate Version
38.00
25.00
Pin Out Specification ST Version
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only