Click on Series name for product info on aimtec.com Series AME40-MAZ 40 Watt | AC-DC / DC-DC Converter FEATURES: • • • • 4000VAC I/O isolation Medical Switching power modules for PCB mounting Operating temperature: -40 to +85°C Universal Input: 90-264VAC, 47-440Hz, or 130-370VDC • • • • Energy star compliant RoHS compliant Low Ripple and Noise CE, cULus approvals CB Models Single output Model Input Voltage (VAC/Hz) AME40-3.3SMAZ AME40-5SMAZ AME40-12SMAZ AME40-15SMAZ AME40-24SMAZ Input Voltage (VDC) Output Voltage (V) Maximum Capacitive load (µF) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 130-370 130-370 130-370 130-370 130-370 3.3 5 12 15 24 8200 8200 2200 1500 560 Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Maximum Capacitive load (µF) Output Current max (A) 8 8 3.33 2.66 1.66 Efficiency (%) 115 230 VAC VAC 77 80 84 84 82 75 80 85 84 82 Models Dual output Model Output Current max (A) Efficiency (%) 115 230 VAC VAC AME40-5DMAZ 90-264/47-440 130-370 ±5 3300 ±4 80 80 AME40-12DMAZ 90-264/47-440 130-370 ±12 2200 ±1.66 82 80 AME40-15DMAZ 90-264/47-440 130-370 ±15 1000 ±1.33 82 81 AME40-24DMAZ 90-260/47-440 130-370 ±24 470 ±0.835 79 77 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Current Inrush current <2ms Leakage current External fuse Input dissipation Start-up time Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC Recommended slow blow type 115 / 230 VAC 3.15 ≤0.5 150 Conditions Typical (LL-HL) 0-100% load single 0-100% load dual st nd 25% load - 1 out, 100% load – 2 out 25% load Step 3.3 / 5V models 12 / 15V models 24V models 115VAC ±2 ±2 ±3 ±3 ±5 ±2 75 100 150 15 0 Maximum Units 1000 530 30 50 0.15 mA mA A A mA A W ms Maximum Units Output Specifications Parameters Voltage accuracy Line regulation Load regulation Cross regulation Transient response deviation Ripple & Noise* Hold-up time (min) Minimum Load Current *Ripple & Noise measured at 20MHz bandwidth with 0.1μF M/C and 47μF E/C www.aimtec.com F 052e R8.L Tel: +1 514 620 2722 1 of 4 % % % % % of Vout mV p-p ms % of Max Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME40-MAZ 40 Watt | AC-DC / DC-DC Converter Isolation Specifications Parameters Conditions Tested I/O voltage Isolation Resistance Typical 60 sec Rated Units 4000 VAC MΩ >1000 General Specifications Parameters Conditions Switching frequency Protection class Over current protection Over voltage protection Short circuit protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L X H X W) Typical 47 Class II 110 Zener diode clamp Auto recovery -40 - +85 Foldback With derating above 50ºC Maximum KHz 140 110 % % o C C o C o %/ C o 100 -40 to +95 0.02 Free air convection Non condensing MTBF Units 95 Plastic (flammability to UL 94V-0) 300 3.56 x 2.48 x 1.18 inches 90.5 x 63 x 30 mm o > 800,000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load > 200,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load % RH g Environment Approval Test Shock Vibration Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052e R8.L cULus, CE, CB Medical Electrical Equipment Information technology Equipment Harmonic Current Emissions EMI - Conducted and radiated emission Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90 EN 60950-1:2006+A11:2009 IEC/EN 61000-3-2, Class A EN55011, class B IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 2 IEC 61000-4-4 Level 3 IEC 61000-4-5 Level 2 IEC 61000-4-6 Level 2 IEC 61000-4-8 Level 2 IEC 61000-4-11 Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME40-MAZ 40 Watt | AC-DC / DC-DC Converter Pin Out Specifications Pin Single Dual 1 2 3 4 5 AC Input (N) AC Input (L) +V Output -V Output No pin AC Input (N) AC Input (L) +V Output Common -V Output 3.56 (0.14) 3.56 (0.14) Dimensions 90.50 (3.56) 3 Top View 4 27.94 (1.10) 55.88 (2.20) 63.00 (2.48) 27.94 (1.10) 2 5 3.56 (0.14) 3.56 (0.14) 1 81.30 (3.20) 4.60 (0.18) 5Ø 1.30 (Ø 0.05) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.30 ± 0.05 (0.05 ± 0.002) Pin Pitch Tolerance ±0.35 (±0.014) Side View 30.00 (1.18) DIV: 10.00 (0.40) 4.60 (0.18) 10.00 (0.40) 1.30 (0.05) Derating Free Air Convection 50º C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C www.aimtec.com F 052e R8.L Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME40-MAZ 40 Watt | AC-DC / DC-DC Converter Earth/Ground Connection EMC EN55022 class B compliant Application circuit L1 35mH ASE2501V-G +Vout L 90-264VAC CX1 0.6uF CX2 0.6uF AMExw40-MAZ N -Vout The Application circuit is EMC compliant for any type of Earth/Ground connection: Input Ground connection, Output Ground connection as shown or both sides, which is not recommended if the product Isolation is used as a Safety feature. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.L Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only