EN27LN1G08 EN27LN1G08 1 Gigabit (128 M x 8), 3.3 V NAND Flash Memory Features • Voltage Supply: 2.7V ~ 3.6V • Reliable CMOS Floating-Gate Technology • Organization - Memory Cell Array : (128M + 4M) x 8bit for 1Gb - Data Register : (2K + 64) x 8bit • Endurance: - 100K Program/Erase Cycles (with 1 bit/528 bytes ECC) - Data Retention: 10 Years • Automatic Program and Erase - Page Program : (2K + 64) bytes - Block Erase : (128K + 4K) bytes • Command Driven Operation • Cache Program Operation for High Performance Program • Page Read Operation - Page Size : (2K + 64) bytes - Random Read : 25µs (Max.) - Serial Access : 25ns (Min.) • Copy-Back Operation • OTP Operation • Unique ID for Copyright Protection • Memory Cell: 1bit/Memory Cell • Fast Write Cycle Time - Page Program Time : 200µs (Typ.) - Block Erase Time : 1.5ms (Typ.) • Command/Address/Data Multiplexed I/O Port • Hardware Data Protection - Program/Erase Lockout During Power Transitions This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 General Description Offered in 128Mx8 bits, this device is 1Gbit with spare 32Mbit capacity. The device is offered in 3.3V VCC. Its NAND cell provides the most cost effective solution for the solid state mass storage market. A program operation can be performed in typical 200us on the 2,112-byte page and an erase operation can be performed in typical 1.5ms on a (128K+4K) bytes block. Data in the data register can be read out at 25ns cycle time per byte. The I/O pins serve as the ports for address and data input/output as well as command input. The on-chip write controller automates all program and erase functions including pulse repetition, where required, and internal verification and margining of data. Even the write-intensive systems can take advantage of this device’s extended reliability of 100K program/erase cycles by providing ECC (Error Correcting Code) with real time mapping-out algorithm. This device is an optimum solution for large nonvolatile storage applications such as solid state file storage and other portable applications requiring non-volatility. Pin Configuration (TOP VIEW) (TSOPI 48L, 12mm X 20mm Body, 0.5mm Pin Pitch) NC NC NC NC NC NC RY/B# RE# CE# NC NC Vcc Vss NC NC CLE ALE WE# WP# NC NC NC NC NC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 Standard TSOP This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. NC NC NC NC I/O7 I/O6 I/O5 I/O4 NC NC NC Vcc Vss NC NC NC I/O3 I/O2 I/O1 I/O0 NC NC NC NC ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 (TOP VIEW) (BGA 63L, 9mm X 11mm X 1.0mm Body, 0.8mm Pin Pitch) This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Table 1. Pin Description Symbol I/O0 – I/O7 CLE ALE CE# RE# WE# WP# R/B# Pin Name Function The I/O pins are used to input command, address and data, and Data Inputs/Outputs to output data during read operations. The I/O pins float to Hi-Z when the chip is deselected or when the outputs are disabled. The CLE input controls the activating path for commands sent to Command Latch the command register. When active high, commands are latched Enable into the command register through the I/O ports on the rising edge of the WE# signal. The ALE input controls the activating path for address to the Address Latch internal address registers. Addresses are latched on the rising Enable edge of WE# with ALE high. The CE# input is the device selection control. When the device is Chip Enable in the Busy state, CE# high is ignored, and the device does not return to standby mode. The RE# input is the serial data-out control, and when active drives the data onto the I/O bus. Data is valid tREA after the falling Read Enable edge of RE# which also increments the internal column address counter by one. The WE# input controls writes to the I/O port. Commands, Write Control address and data are latched on the rising edge of the WE# pulse. The WP# pin provides inadvertent program/erase protection Write Protect during power transitions. The internal high voltage generator is reset when the WP# pin is active low. The R/B# output indicates the status of the device operation. When low, it indicates that a program, erase or random read Ready/Busy Output operation is in process and returns to high state upon completion. It is an open drain output and does not float to Hi-Z condition when the chip is deselected or when outputs are disabled. VCC Power Supply VSS Ground NC No Connection VCC is the power supply for device. Lead is not internally connected. Note: Connect all VCC and VSS pins of each device to common power supply outputs. Do not leave VCC or VSS disconnected. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Block Diagram Functional Block Diagram Array Organization This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Address Cycle Map I/O 0 I/O 1 I/O 2 I/O 3 I/O 4 I/O 5 I/O 6 I/O 7 Address 1st Cycle A0 A1 A2 A3 A4 A5 A6 A7 Column Address 2nd Cycle A8 A9 A10 A11 L* L* L* L* Column Address 3rd Cycle A12 A13 A14 A15 A16 A17 A18 A19 Row Address 4th Cycle Note: A20 A21 A22 A23 A24 A25 A26 A27 Page Address 1. Column Address : Starting Address of the Register. 2. * L must be set to “Low”. 3. * The device ignores any additional input of address cycles than required. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Ordering Information EN27LN 1G 08 - 25 T C P PACKAGING CONTENT P = RoHS, Halogen-Free and REACH compliant TEMPERATURE RANGE C = Commercial (0℃ to +70℃) I = Industrial (-40℃ to +85℃) PACKAGE T = 48-pin TSOP CE = 63L 9x11x1.0mm BGA, pitch: 0.8mm, ball: 0.45mm SPEED OPTION for BURST ACCESS TIME 25 = 25ns Data Length 08 = 8-bit width DENSITY 1G = 1Gigabit [(128M + 4M) x 8 Bit] BASE PART NUMBER EN = Eon Silicon Solution Inc. 27LN = 3.0V Operation NAND Flash This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Product Introduction This device is a 1,056Mbits (1,107,296,256 bits) memory organized as 65,539 rows (pages) by 2,112byte columns. Spare 64-byte columns are located from column address of 2,048 to 2,111. A 2,112-byte data register and 2,112-byte cache register are serially connected to each other. Those serially connected registers are connected to memory cell arrays for accommodating data transfer between the I/O buffers and memory cells during page read and page program operations. The memory array is made up of 32 cells that are serially connected to form a NAND structure. Each of the 32 cells resides in a different page. A block consists of two NAND structured strings. A NAND structure consists of 32 cells. Total 1,081,344 NAND cells reside in a block. The program and read operations are executed on a page basis, while the erase operation is executed on a block basis. The memory array consists of 1,024 separately erasable 128K-byte blocks. It indicates that the bit by bit erase operation is prohibited on the device. This device uses addresses multiplexed scheme. This scheme dramatically reduces pin counts and allows systems upgrades to future densities by maintaining consistency in system board design. Command, address and data are all written through I/O's by bringing WE# to low while CE# is low. Those are latched on the rising edge of WE#. Command Latch Enable (CLE) and Address Latch Enable (ALE) are used to multiplex command and address respectively, via the I/O pins. Some commands require one bus cycle. For example, Reset Command, Status Read Command, etc require just one cycle bus. Some other commands, like page read and block erase and page program, require two cycles: one cycle for setup and the other cycle for execution. The total physical space requires 28 addresses, thereby requiring four cycles for addressing: 2 cycle of column address, 2 cycles of row address, in that order. Page Read and Page Program need the same four address cycles following the required command input. In Block Erase operation, however, only the 2 cycles of row address are used. Device operations are selected by writing specific commands into the command register. Below table defines the specific commands of this device. The device provides cache program in a block. It is possible to write data into the cache registers while data stored in data registers are being programmed into memory cells in cache program mode. The program performance may be dramatically improved by cache program when there are lots of pages of data to be programmed. In addition to the enhanced architecture and interface, the device incorporates copy-back program feature from one page to another page without need for transporting the data to and from the external buffer memory. Since the time-consuming serial access and data-input cycles are removed, system performance for solid-state disk application is significantly increased. Command Set Function 1st Cycle 2nd Cycle Read 00h 30h Read for Copy Back 00h 35h Read ID 90h - Reset FFh - Page Program 80h 10h Cache Program 80h 15h Copy-Back Program 85h 10h Block Erase 60h D0h Random Data Input(1) 85h - Random Data Output(1) 05h E0h Read Status 70h - Acceptable Command during Busy O O Note: 1. Random Data Input / Output can be executed in a page. Caution: Any undefined command inputs are prohibited except for above command set of above table. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Absolute Maximum Ratings Parameter Voltage on any pin relative to VSS Temperature Under Bias Storage Temperature Short Circuit Current Symbol VCC VIN VI/O TBIAS TSTG IOS Rating -0.6 to +4.6 Unit V -0.6 to VCC + 0.3 (< 4.6) -40 to +125 ℃ ℃ mA -65 to +150 5 Note: 1. Minimum DC voltage is -0.6V on input/output pins. During transitions, this level may undershoot to 2.0V for periods <30ns. Maximum DC voltage on input/output pins is VCC+0.3V which, during transitions, may overshoot to VCC+2.0V for periods <20ns. 2. Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded. Functional operation should be restricted to the conditions as detailed in the operational sections of this data sheet. Exposure to absolute maximum rating conditions for extended periods may affect reliability. RECOMMENDED OPERATING CONDITIONS (Voltage reference to GND, TA = 0 to 70°C or – 40°C to 85°C) Parameter Supply Voltage Supply Voltage Symbol VCC VSS Min. 2.7 0 Typ. 3.3 0 Max. 3.6 0 Unit V V DC AND OPERATION CHARACTERISTICS (Recommended operating conditions otherwise noted) Parameter Symbol Test Conditions Min. Typ. Max. Sequential Read Operating Program Current Erase Stand-by Current (TTL) Stand-by Current (CMOS) ICC1 ICC2 ICC3 ISB1 ISB2 tRC=25ns, CE# =VIL, IOUT=0mA CE# =VIH, WP# =0V/VCC CE# = VCC -0.2, WP# =0V/ VCC - 15 15 15 10 Unit Input Leakage Current ILI VIN=0 to VCC (max) - - 30 30 30 1 50 ±10 Output Leakage Current ILO VOUT=0 to VCC (max) - - ±10 uA 0.8 x VCC -0.3 2.4 8 10 VCC +0.3 0.2 x VCC 0.4 - V V V V mA Input High Voltage Input Low Voltage, All inputs Output High Voltage Level Output Low Voltage Level Output Low Current (R/B#) VIH VIL VOH VOL IOL (R /B#) IOH=-400uA IOL=2.1mA VOL=0.4V Note: 1. VIL can undershoot to -0.4V and VIH can overshoot to VCC+0.4V for durations of 20ns or less. 2. Typical value are measured at VCC =3.3V, TA = 25℃. And not 100% tested. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 mA mA uA uA EN27LN1G08 VALID BLOCK Symbol NVB Min. 1,004 Typ. - Max. 1,024 Unit Blocks Note: 1. The device may include initial invalid blocks when first shipped. Additional invalid blocks may develop while being used. The number of valid blocks is presented as first shipped. Invalid blocks are defined as blocks that contain one or more bad bits which cause status failure during program and erase operation. Do not erase or program factory-marked bad blocks. Refer to the attached technical notes for appropriate management of initial invalid blocks. 2. The 1st block, which is placed on 00h block address, is guaranteed to be a valid block up to 1K program/erase cycles with 1 bit/528 bytes ECC. AC TEST CONDITION (TA = 0 to 70°C or – 40°C to 85°C, VCC=2.7V~3.6V, unless otherwise noted) Parameter Input Pulse Levels Input Rise and Fall Times Input and Output Timing Levels Output Load Condition 0V to VCC 5 ns VCC /2 1 TTL Gate and CL=50pF CAPACITANCE (TA = 25°C, VCC=3.3V, f =1.0MHz) Item Symbol Test Condition Input / Output Capacitance CI/O VIL = 0V Input Capacitance CIN VIN = 0V Note: Capacitance is periodically sampled and not 100% tested. Min. - Max. 8 8 Unit pF pF MODE SELECTION CLE ALE CE# WE# RE# WP# Mode H L L Rising H X Command Input Read Mode L H L Rising H X Address Input (4 clock) H L L Rising H H Command Input Write Mode L H L Rising H H Address Input (4 clock) L L L Rising H H Data Input L L L H Falling X Data Output X X X X H X During Read (Busy) X X X X X H During Program (Busy) X X X X X H During Erase (Busy) X X(1) X X X L Write Protect X X H X X 0V/VCC(2) Stand-by Note: 1. X can be VIL or VIH. 2. WP# should be biased to CMOS high or CMOS low for stand-by. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Program / Erase Characteristics Parameter Symbol Min. Typ. Max. Unit (1) Program Time tPROG 200 700 us Dummy Busy Time for Cache tCBSY(2) 3 700 us Program Number of Partial Program Cycles NOP 4 Cycle in the Same Page Block Erase Time tBERS 1.5 10 ms Note: 1. Typical program time is defined as the time within which more than 50% of the whole pages are programmed at 3.3V VCC and 25°C temperature. 2. Max. time of tCBSY depends on timing between internal program completion and data in. AC Timing Characteristics for Command / Address / Data Input Parameter Symbol Min. Max. Unit CLE Setup Time tCLS(1) 12 ns CLE Hold Time tCLH 5 ns CE# Setup Time tCS 20 ns CE# Hold Time tCH 5 ns WE# Pulse Width tWP 12 ns ALE Setup Time tALS(1) 12 ns ALE Hold Time tALH 5 ns (1) Data Setup Time tDS 12 ns Data Hold Time tDH 5 ns Write Cycle Time tWC 25 ns WE# High Hold Time tWH 10 ns (2) ALE to Data Loading Time tADL 100 ns Note: 1. The transition of the corresponding control pins must occur only once while WE# is held low. 2. tADL is the time from the WE# rising edge of final address cycle to the WE# rising edge of first data cycle. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 AC Characteristics for Operation Parameter Symbol Min. Max. Unit Data Transfer from Cell to Register tR 25 us ALE to RE# Delay tAR 10 ns CLE to RE# Delay tCLR 10 ns Ready to RE# Low tRR 20 ns RE# Pulse Width tRP 12 ns WE# High to Busy tWB 100 ns Read Cycle Time tRC 25 ns RE# Access Time tREA 20 ns CE# Access Time tCEA 25 ns RE# High to Output Hi-Z tRHZ 100 ns CE# High to Output Hi-Z tCHZ 30 ns CE# High to ALE or CLE Don’t Care tCSD 0 ns RE# High to Output Hold tRHOH 15 ns RE# Low to Output Hold tRLOH 5 ns CE# High to Output Hold tCOH 15 ns RE# High Hold Time tREH 10 ns Output Hi-Z to RE# Low tIR 0 ns RE# High to WE# Low tRHW 100 ns WE# High to RE# Low tWHR 60 ns Read 5(1) us (1) Device Resetting Program 10 us tRST Time during ... Erase 500(1) us us Ready 5(1) Note: 1. If reset command (FFh) is written at Ready state, the device goes into Busy for maximum 5us. NAND Flash Technical Notes Initial Invalid Block(s) Initial invalid blocks are defined as blocks that contain one or more initial invalid bits whose reliability is not guaranteed by Eon. Information regarding the initial invalid block(s) is so called as the initial invalid block information. Devices with initial invalid block(s) have the same quality level as devices with all valid blocks and have the same AC and DC characteristics. An initial invalid block(s) does not affect the performance of valid block(s) because it is isolated from the bit line and the common source line by a select transistor. The system design must be able to mask out the initial invalid block(s) via address mapping. The 1st block, which is placed on 00h block address, is guaranteed to be a valid block up to 1K program/erase cycles with 1 bit/528 bytes ECC. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Identifying Initial Invalid Block(s) All device locations are erased (FFh) except locations where the initial invalid block(s) information is written prior to shipping. The initial invalid block(s) status is defined by the 1st byte in the spare area. Eon makes sure that either the 1st or 2nd page of every initial invalid block has non-FFh data at the 1st byte column address in the spare area. Since the initial invalid block information is also erasable in most cases, it is impossible to recover the information once it has been erased. Therefore, the system must be able to recognize the initial invalid block(s) based on the initial invalid block information and create the initial invalid block table via the following suggested flow chart. Any intentional erasure of the initial invalid block information is prohibited. Error in write or read operation Within its life time, the additional invalid blocks may develop with NAND Flash memory. Refer to the qualification report for the block failure rate. The following possible failure modes should be considered to implement a highly reliable system. In the case of status read failure after erase or program, block replacement should be done. Because program status fail during a page program does not affect the data of the other pages in the same block, block replacement can be executed with a page-sized buffer by finding an erased empty block and reprogramming the current target data and copying the rest of the replaced block. In case of Read, ECC must be employed. To improve the efficiency of memory space, it is recommended that the read failure due to single bit error should be reclaimed by ECC without any block replacement. The block failure rate in the qualification report does not include those reclaimed blocks. Failure Write Read Detection and Countermeasure sequence Erase Failure Status Read after Erase → Block Replacement Program Failure Status Read after Program → Block Replacement Single Bit Failure Verify ECC → ECC Correction ECC: 1. Error Correcting Code --> Hamming Code etc. 2. Example) 1bit correction & 2bits detection This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Program Flow Chart This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Erase Flow Chart This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Read Flow Chart START CMD 00h Write Address CMD 30h Read Data Reclaim the Error No Verify ECC Yes Page Read Completed This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Block Replacement Addressing for program operation Within a block, the pages must be programmed consecutively from the LSB (Least Significant Bit) page of the block to MSB (Most Significant Bit) pages of the block. Random page address programming is prohibited. Page 63 (64) (64) Page 63 : Page 31 : (32) (1) Page 31 : : Page 2 (3) Page 2 (3) Page 1 (2) Page 1 (32) Page 0 (1) Page 0 (2) Data register Data register From the LSB page to MSB page Ex.) Random page program (Prohibition) DATA IN: Data (1) DATA IN: Data (1) Data (64) This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. Data (64) ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 System Interface Using CE# don’t-care For an easier system interface, CE# may be inactive during the data-loading or sequential data-reading as shown below. The internal 2,112 bytes page registers are utilized as separate buffers for this operation and the system design gets more flexible. In addition, for voice or audio applications which use slow cycle time on the order of u-seconds, de-activating CE# during the data-loading and reading would provide significant savings in power consumption. Below are the figures of Program Operation and Read Operation with CE# don’t-care respectively. Address Information I/O I/Ox I/O0~7 DATA Data In / Out ~ 2112 bytes Col. Add1 A0 ~ A7 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ADDRESS Col. Add2 Row Add1 A8 ~ A11 A12 ~ A19 Row Add2 A20 ~ A27 ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Command Latch Cycle Address Latch Cycle Input Data Latch Cycle This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Serial access Cycle after Read (CLE = L, ALE = L, WE# = H) Note: 1. Transition is measured at ±200mV from steady state voltage with load. 2. This parameter is sampled and not 100% tested. 3. tRLOH is valid when frequency is higher than 33MHz. 4. tRHOH starts to be valid when frequency is lower than 33MHz. Status Read Cycle This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Read Operation Read Operation (Intercepted by CE#) This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Random Data Output In a Page Page Program Operation Note: tADL is the time from WE# rising edge of final address cycle to the WE# rising edge of first data cycle. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Page Program Operation with Random Data Input Note: tADL is the time from WE# rising edge of final address cycle to the WE# rising edge of first data cycle. Copy-Back Program Operation with Random Data Input Note: tADL is the time from WE# rising edge of final address cycle to the WE# rising edge of first data cycle. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Cache Program Operation (available only within a block) Block Erase Operation (Erase One Block) This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Read ID Operation ID Definition Table ID Access command = 90h Maker Code 92h Device Code F1h 3rd Cycle 80h 4th Cycle 95h 5th Cycle 40h Description st 1 Byte 2nd Byte 3rd Byte 4th Byte 5th Byte Maker Code Device Code Internal Chip Number, Cell Type, Number of Simultaneously Programmed Pages, Etc. Page Size, Block Size, Redundant Area Size, Organization, Serial Access Minimum Plane Number, Plane Size 3rd ID Data Internal Chip Number Cell Type Number of Simultaneously Programmed Page Interleave Program Between multiple chips Cache Program Description 1 2 4 8 2 Level Cell 4 Level Cell 8 Level Cell 16 Level Cell 1 2 4 8 Not Support I/O7 I/O6 I/O4 0 0 1 1 I/O3 I/O2 0 0 1 1 0 1 0 1 I/O1 0 0 1 1 0 1 0 1 0 Support Not Support Support I/O5 1 0 1 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 I/O0 0 1 0 1 EN27LN1G08 4th ID Data Page Size (w/o redundant area) Block Size (w/o redundant area) Redundant Area Size (byte/512byte) Organization Serial Access Minimum Descriptio n 1KB 2KB 4KB 8KB 64KB 128KB 256KB 512KB 8 16 x8 x16 50ns / 30ns 25ns Reserved Reserved I/O7 I/O6 I/O5 I/O4 0 0 1 1 I/O3 I/O2 I/O1 I/O0 0 0 1 1 0 1 0 1 I/O1 I/O0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 5th ID Data Plane Number Plane Size (w/o redundant area) Reserved Descriptio n 1 2 4 8 64Mb 128Mb 256Mb 512Mb 1Gb 2Gb 4Gb 8Gb 50ns / 30ns I/O7 I/O6 0 0 0 0 1 1 1 1 I/O5 I/O4 0 0 1 1 0 0 1 1 I/O2 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. I/O3 ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 DEVICE OPERATION Page Read Page read is initiated by writing 00h-30h to the command register along with four address cycles. After initial power up, 00h command is latched. Therefore only four address cycles and 30h command initiates that operation after initial power up. The 2,112 bytes of data within the selected page are transferred to the data registers in less than tR. The system controller can detect the completion of this data transfer (tR) by analyzing the output of R/B# pin. Once the data in a page is loaded into the data registers, they may be read out in 25ns cycle time by sequentially pulsing RE#. The repetitive high to low transitions of the RE# clock make the device output the data starting from the selected column address up to the last column address. The device may output random data in a page instead of the consecutive sequential data by writing random data output command. The column address of next data, which is going to be out, may be changed to the address which follows random data output command. Random data output can be operated multiple times regardless of how many times it is done in a page. Read Operation This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Random Data Output In a Page This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Page Program The device is programmed basically on a page basis, but it does allow multiple partial page programming of a word or consecutive bytes up to 2,112, in a single page program cycle. The number of consecutive partial page programming operation within the same page without an intervening erase operation must not exceed 4 times for a single page. The addressing should be done in sequential order in a block. A page program cycle consists of a serial data loading period in which up to 2,112 bytes of data may be loaded into the data register, followed by a non-volatile programming period where the loaded data is programmed into the appropriate cell. The serial data loading period begins by inputting the Serial Data Input command (80h), followed by the four cycle address inputs and then serial data loading. The words other than those to be programmed do not need to be loaded. The device supports random data input in a page. The column address for the next data, which will be entered, may be changed to the address which follows random data input command (85h). Random data input may be operated multiple times regardless of how many times it is done in a page. The Page Program confirm command (10h) initiates the programming process. Writing 10h alone without previously entering the serial data will not initiate the programming process. The internal write state controller automatically executes the algorithms and timings necessary for program and verify, thereby freeing the system controller for other tasks. Once the program process starts, the Read Status Register command may be entered, with RE# and CE# low, to read the status register. The system controller can detect the completion of a program cycle by monitoring the R/B# output, or the Status bit (I/O6) of the Status Register. Only the Read Status command and Reset command are valid while programming is in progress. When the Page Program is complete, the Write Status Bit (I/O0) may be checked. The internal write verify detects only errors for "1"s that are not successfully programmed to "0"s. The command register remains in Read Status command mode until another valid command is written to the command register. Program & Read Status Operation Random Data Input In a page This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Cache Program Cache Program is an extension of Page Program, which is executed with 2,112 byte data registers, and is available only within a block. Since the device has 1 page of cache memory, serial data input may be executed while data stored in data register are programmed into memory cell. After writing the first set of data up to 2,112 bytes into the selected cache registers, Cache Program command (15h) instead of actual Page Program (10h) is inputted to make cache registers free and to start internal program operation. To transfer data from cache registers to data registers, the device remains in Busy state for a short period of time (tCBSY) and has its cache registers ready for the next data-input while the internal programming gets started with the data loaded into data registers. Read Status command (70h) may be issued to find out when cache registers become ready by polling the Cache-Busy status bit (I/O6). Pass/fail status of only the previous page is available upon the return to Ready state. When the next set of data is inputted with the Cache Program command, tCBSY is affected by the progress of pending internal programming. The programming of the cache registers is initiated only when the pending program cycle is finished and the data registers are available for the transfer of data from cache registers. The status bit (I/O5) for internal Ready/Busy may be polled to identity the completion of internal programming. If the system monitors the progress of programming only with R/B#, the last page of the target programming sequence must be programmed with actual Page Program command (10h). Cache Program (available only within a block) Note: 1. Since programming the last page does not employ caching, the program time has to be that of Page Program. However, if the previous program cycle with the cache data has not finished, the actual program cycle of the last page is initiated only after completion of the previous cycle, which can be expressed as the following formula. 2. tPROG = Program time for the last page + Program time for the (last-1)th page – (Program command cycle time + Last page data loading time) This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Copy-Back Program Copy-Back program with Read for Copy-Back is configured to quickly and efficiently rewrite data store in one page. The benefit is especially obvious when a portion of a block is updated and the rest of the block also needs to be copied to the newly assigned free block. Copy-Back operation is a sequential execution of Read for Copy-Back and of copy-back program with the destination page address. A read operation with “35h” command and the address of the source page moves the whole 2,112-byte data into the internal data buffer. A bit error is checked by sequential reading the data output. In the case where there is no bit error, the data do not need to be reloaded. Therefore Copy-Back program operation is initiated by issuing Page-Copy Data-Input command (85h) with destination page address. Actual programming operation begins after Program Confirm command (10h) is issued. Once the program process starts, the Read Status Register command (70h) may be entered to read the status register. The system controller can detect the completion of a program cycle by monitoring the R/ B output, or the Status bit (I/O6) of the Status Register. When the Copy-Back Program is completed, the Write Status Bit (I/O0) may be checked. The command register remains in Read Status command mode until another valid command is written to the command register. During coy-back program, data modification is possible using random data input command (85h). Page Copy-Back Program Operation Note: 1. This operation is allowed only within the same memory plane. 2. It’s prohibited to operate Copy-Back program from an odd address page (source page) to an even address (target page) or from an even address page (source page) to an odd address page (target page). Therefore, the Copy-Back program is permitted just between odd address pages or even address pages. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Page Copy-Back Program Operation with Random Data Input Block Erase The Erase operation is done on a block basis. Block address loading is accomplished in two cycles initiated by an Erase Setup command (60h). Only address A18 to A27 is valid while A12 to A17 is ignored. The Erase Confirm command (D0h) following the block address loading initiates the internal erasing process. This two-step sequence of setup followed by execution command ensures that memory contents are not accidentally erased due to external noise conditions. At the rising edge of WE# after the erase confirm command input, the internal write controller handles erase and erase-verify. When the erase operation is completed, the Write Status Bit (I/O0) may be checked. Block Erase Operation This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 One-Time Programmable (OTP) Operations This Eon flash device offers one-time programmable memory area. Thirty full pages of OTP data are available on the device, and the entire range is guaranteed to be good. The OTP area is accessible only through the OTP commands. The OTP area leaves the factory in an unwritten state. The OTP area cannot be erased, whether it is protected or not. Protecting the OTP area prevents further programming of that area. The OTP area is only accessible while in OTP operation mode. To set the device to OTP operation mode, issue the Set Feature (EFh-90h-01h) command. When the device is in OTP operation mode, subsequent Read and/or Page Program are applied to the OTP area. When you want to come back to normal operation, you need to use EFh-90h-00h for OTP mode release. Otherwise, device will stay in OTP mode. To program an OTP page, issue the Serial Data Input (80h) command followed by 4 address cycles. The first two address cycles are column address that must be set as 00h. For the third cycle, select a page in the range of 00h through 1Dh. The fourth and fifth cycle is fixed at 00h. Next, up to 2,112 bytes of data can be loaded into data register. The bytes other than those to be programmed do not need to be loaded. Random Data Input (85h) command in this device is prohibited. The Page Program confirms (10h) command initiates the programming process. The internal control logic automatically executes the programming algorithm, timing and verification. Please note that no partial-page program is allowed in the OTP area. In addition, the OTP pages must be programmed in the ascending order. A programmed OTP page will be automatically protected. Similarly, to read data from an OTP page, set the device to OTP operation mode and then issue the Read (00h-30h) command. The first two address cycles are column address that must be set as 00h and Random Data Output (05h-E0h) command is prohibited as well. All pages in the OTP area will be protected simultaneously by issuing the Set Feature (EFh-90h-03h) command to set the device to OTP protection mode. After the OTP area is protected, no page in the area is programmable and the whole area cannot be unprotected. The Read Status (70h) command is the only valid command for reading status in OTP operation mode. Table 2. OTP Modes and Commands Set Feature 1 Command 2 Read EFh-90h -01h 00h-30h Page Program EFh-90h-01h 80h-10h OTP Protection mode Program Protect EFh-90h-03h 80h-10h OTP Release mode Leave OTP mode EFh-90h-00h OTP Operation mode Note: 1. 90h is OTP status register address. 2. 00h, 01h, and 03h are OTP status register data values. Table 3. OTP Area Details Description Value Number of OTP pages 30 OTP pages address 00h – 1Dh Number of partial page programs for each page in the OTP area This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 1 ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Read Status The device contains a Status Register which may be read to find out whether program or erase operation is completed, and whether the program or erase operation is completed successfully. After writing 70h command to the command register, a read cycle outputs the content of the Status Register to the I/O pins on the falling edge of CE# or RE#, whichever occurs last. This two line control allows the system to poll the progress of each device in multiple memory connections even when R/B# pins are common-wired. RE# or CE# does not need to be toggled for updated status. Refer to below table for specific Status Register definitions. The command register remains in Status Read mode until further commands are issued to it. Therefore, if the status register is read during a random read cycle, the read command (00h) should be given before starting read cycles. Status Register Definition for 70h Command I/O I/O0 I/O1 Page Pass / Fail Not Use (Pass/Fail, OTP) Block Pass / Fail Read Not Use Cache Pass / Fail(N) Not Use Not Use Pass / Fail(N-1) I/O2 I/O3 I/O4 Not Use Not Use Not Use Not Use Not Use Not Use Not Use Not Use Not Use I/O5 Ready / Busy Ready / Busy Ready / Busy I/O6 Ready / Busy Ready / Busy Ready / Busy Not Use Not Use Not Use True Ready / Busy Ready / Busy I/O7 Write Protect Write Protect Write Protect Write Protect Definition Pass: ”0” Fail: ”1” Pass: ”0” Fail: ”1” Don’t cared Don’t cared Don’t cared Busy: ”0” Ready: ”1” Busy: ”0” Ready: ”1” Protected: ”0” Not Protected: ”1” Note: 1. True Ready/Busy represents internal program operation status which is being executed in cache program mode. 2. I/Os defined ’Not Use’ are recommended to be masked out when Read Status is being executed. Read ID The device contains a product identification mode, initiated by writing 90h to the command register, followed by an address input of 00h. Four read cycles sequentially output the manufacturer code (92h), and the device code and 3rd, 4th and 5th cycle ID respectively. The command register remains in Read ID mode until further commands are issued to it. Read ID Operation This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 ID Definition Table ID Access command = 90h Maker Code Device Code 3rd Cycle 4th Cycle 5th Cycle 92h F1h 80h 95h 40h Description st 1 Byte 2nd Byte 3rd Byte 4th Byte 5th Byte Maker Code Device Code Internal Chip Number, Cell Type, Number of Simultaneously Programmed Pages, Etc. Page Size, Block Size, Redundant Area Size, Organization, Serial Access Minimum Plane Number, Plane Size RESET The device offers a reset feature, executed by writing FFh to the command register. When the device is in busy state during random read, program or erase mode, the reset operation will abort these operations. The contents of memory cells being altered are no longer valid, as the data will be partially programmed or erased. The command register is cleared to wait for the next command, and the Status Register is cleared to value C0h when WP# is high. If the device is already in reset state a new reset command will be accepted by the command register. The R/B# pin changes to low for tRST after the Reset command is written. Refer to Figure below. Device Status Operation mode After Power-up 00h Command is latched This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. After Reset Waiting for next command ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 READY/BUSY# The device has an R/B# output that provides a hardware method of indicating the completion of a page program, erase and random read completion. The R/B# pin is normally high but transitions to low after program or erase command is written to the command register or random read is started after address loading. It returns to high when the internal controller has finished the operation. The pin is an opendrain driver thereby allowing two or more R/B# outputs to be Or-tied. RP vs tRHOH vs CL RP value guidance where IL is the sum of the input currents of all devices tied to the R/ B# pin. RP (max) is determined by maximum permissible limit of tr This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Data Protection & Power-up sequence The device is designed to offer protection from any involuntary program/erase during power-transitions. An internal voltage detector disables all functions whenever VCC is below about 2V. WP# pin provides hardware protection and is recommended to be kept at VIL during power-up and power-down. A recovery time of minimum 100us is required before internal circuit gets ready for any command sequences as below. The two step command sequence for program/erase provides additional software protection. AC Waveforms for Power Transition Note: During the initialization, the device consumes a maximum current of ICC1. WP# AC Timing guide Enable WP# during erase and program busy is prohibited. The erase and program operations are enabled and disable as follows. Program enable mode: This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Program disable mode: Erase enable mode: Erase disable mode: This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 PACKAGE DIMENSION 48L TSOP 12mm x 20mm package outline This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 63L 9x11x1.0mm BGA, pitch: 0.8mm, ball: 0.45mm This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03 EN27LN1G08 Revisions List Revision No Description A Initial Release 2011/11/30 1. Add I = Industrial (-40℃ to +85℃) grade temperature option. 2011/12/30 2. Add CE = 63L 9x11x1.0mm BGA, pitch: 0.8mm, ball: 0.45mm package option. 1. Update Ordering Information “ P = RoHS, Halogen-Free and REACH compliant “ on page 7. 2013/10/03 2. Add One-Time Programmable (OTP) Operations description. B C Date This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2013 Eon Silicon Solution, Inc., www.eonssi.com Rev. C, Issue Date: 2013/10/03