Standard module with 9 ATO fuses, 2 mini relays

Standard module with 9 ATO fuses, 2 mini relays
PART NUMBER: 175259
CHARACTERISTICS
• Suitable for 12 V and 24 V applications
• Power supply via power elements up to
max. 70 A
• 7 fuse sockets for ATO fuses up to max. 15 A
• 2 additional sockets for ATO fuses up to
max. 30 A for relay protection
• 2 mini relay sockets 5 pin
• Rear connector 18 pin, 3 rows – JPT and MCP
compatible
• High thermal load
• Shock and vibration resistant
• Also available with populated board (relays,
fuses resp. automatic circuit breakers supressor
diodes)
APPLICATIONS
• Power distribution within the automotive segment, such as alternators, control and indication devices,
radio, accessories etc.
• Applicable individually or modular
TECHNICAL DATA
Operational temperature
-40° C to +85° C
Max. power supply
Max. 70 A at 65° C ambient temperature
Max. 65 A at 80° C ambient temperature
Output
Connector 3 row, 18 pin, JPT/MCP compatible
Input
Power element socket M5, max. torque: 2.2 Nm
(other designs on request)
Recommended cable crosssection for connector*
Current I ≤ 15 A: 7.5 A per mm2
Current I > 15 A: 5 A per mm2
*Note derating of connector
Datasheet E 074625 10/13
Edition 1
www.erni.com
Standard module with 9 ATO fuses, 2 mini relays
PART NUMBER: 175259
DIMENSIONS
15.7 mm
18.7 mm
102 mm
Measurements
dependents on
­component size
24.3 mm
Bending radius
≈ 50 mm
60 mm
40.5 mm
2.4 mm
ELECTRIC CIRCUIT DIAGRAM
*optional
K601
85
30
F601
30 A
Mini Relay
F602
87
X601.6
15 A
+ Power
F606
X601.16
X601.18
X601.17
5A
X601.7
87 A
X601.2
X601.4
86
X601.1
X601.8
D601
X601.5
No electrical
use
*
X601.3
F604
X601.9
15 A
F608
7.5 A
F609
10 A
F606
X601.15
7.5 A
Mini Relay
F607
30
85
X602
F605
X601.12
87
X601.10
X601.13
87 A
X601.14
K602
*
86
X601.11
D602
X603
15 A
15 A
CAUTION: Note maximum supply current
Datasheet E 074625 10/13
Edition 1