Standard module with 16 ATO fuses PART NUMBER: 175261 CHARACTERISTICS • Suitable for 12 V and 24 V applications • Power supply via M5 power elements up to max. 80 A • 16 fuse sockets for ATO fuses up to max. 25 A • Rear connector 21 pin, 3 rows – JPT and MCP compatible • High thermal load • Shock and vibration resistant • Also available with populated board (relays, fuses resp. automatic circuit breakers) APPLICATIONS • Power distribution within the automotive segment, such as alternators, control and indication devices, radio, accessories etc. • Applicable individually or modular TECHNICAL DATA Operational temperature -40° C to +85° C Max. power supply Max. 80 A at 65° C ambient temperature Max. 70 A at 80° C ambient temperature Output Connector 3 row, 21 pin, JPT/MCP compatible Input Power element socket M5, max. torque: 2.2 Nm (other designs on request) Recommended cable crosssection for connector* Current I ≤ 15 A: 7.5 A per mm2 Current I > 15 A: 5 A per mm2 *Note derating of connector Datasheet E 074629 10/13 Edition 1 www.erni.com Standard module with 16 ATO fuses PART NUMBER: 175261 DIMENSIONS 15.7 mm 18.7 mm 102 mm Measurements dependents on component size 24.3 mm 60 mm Bending radius ≈ 50 mm 2.4 mm ELECTRIC CIRCUIT DIAGRAM F210 F201 F202 X201.6 7.5 A X201.8 F212 X201.4 X201.2 15 A X201.7 F203 25 A F204 X201.12 7.5 A X201.14 X201.15 F214 X201.10 15 A X201.9 X201.11 F213 X203 15 A + Power X201.5 X201.3 X201.19 15 A X201.17 X201.18 F215 15 A F205 X202 No electrical use F211 F208 7.5 A 15 A X201.1 25 A F206 X201.13 F209 X201.16 15 A 7.5 A F216 X201.21 15 A F207 X201.20 7.5 A 15 A CAUTION: Note maximum supply current Datasheet E 074629 10/13 Edition 1 www.erni.com