EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:55 Seite 1 EC axial fans - HyBlade® US-edition The engineer’s choice version 05/2011 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:55 Seite 2 The new EC axial fans - HyBlade® A new and unique hybrid blade design makes ebm-papst axial fans even quieter, more powerful and lasting longer. The novel HyBlade® fan blades use a support structure made of highly robust, corrosion-proof aluminium alloy and a coating made of special reinforced fibre plastics. Their aerodynamically optimal form results in enormous acoustic benefits at even higher efficiencies compared to conventional blades. And this, in turn, offers further benefits when used in refrigeration, heating and ventilation. A revolutionary development In refrigeration and ventilation, axial fans are frequently used, for instance to cool heat exchangers with air passing through them. For compact systems, the best tried and tested choice is the ebm-papst external-rotor motor with the axial fan blades mounted onto its rotor. Apart from compact dimensions, the fans in such applications are expected to yield high air performance at minimal noise. So far, fan blades are conventionally made of sheet steel or aluminium. In order to meet exacting requirement for optimum efficiency and acoustic behaviour, ebm-papst focused intensely on developing new blade geometries. However, the limited design possibilities of a monolithic sheet metal blade with uniform sheet thickness are obstacles engineers have to simply accept. To manage the required quantum leap and arrive at lower noise and better efficiency, new construction principles and materials, or component structures, to be more precise, are needed. This is the approach ebm-papst took with its revolutionary hybrid blade concept, using hybrid components and structures to join seemingly irreconcilable characteristic in one harmonious functional unit. The modular system consisting of motor, electronics and impeller allows for optimum configuration, making the new line of EC HyBlade® axial fans unbeatable as to combinatorics and power range. The integrated motor electronics are based on state-of-the-art EC technology and correspond to the “2nd generation”. This makes them highly efficient and they already comply with the latest standards of the defined European Efficiency Classes. 2 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:56 Seite 3 Table of contents New EC axial fans - HyBlade® 2 GreenTech: The Green Company 4 Size 500 6 Size 560 10 Size 630 14 Size 710 20 Size 800 24 Size 910 28 Size 990 32 Electrical connections 35 Technical parameters & scope 40 ebm-papst representatives & subsidiaries 44 3 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:56 Seite 4 Sustainability is at the Centre of Our Thoughts and Actions. Out of Conviction! Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:56 Seite 5 GreenTech is pro-active development. GreenTech is acknowledged and certified. Even in the design phase, the materials and processes we use are optimi- Every step in our chain of production meets the stringent standards of sed for the greatest possible eco-friendliness, energy balance and – environmental specialists and the public. The 2008 Environmental Prize wherever possible – recyclability. We continually improve the material of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency and performance of our products, as well as the flow and noise charac- Award 2009 of the dena – to give just a few examples – testify to this. teristics. At the same time, we significantly reduce energy consumption. The environmental advantage gained in the performance of the products Close cooperation with universities and scientific institutes and the pro- developed from our GreenTech philosophy can also be measured in the fessorship we endow in the area of power engineering and regenerative fulfilment of the most stringent energy and environmental standards. energies allows us to profit from the latest research findings in these In many instances, our products are already well below the thresholds fields – and at the same time ensure highly qualified young academics. energy legislation will impose a few years from now – several times over. GreenTech is ecofriendly production. Our customers profit from this every day. GreenTech also stands for maximum energy efficiency in our production The heart of GreenTech is ebm-papst EC technology. The EC technology processes. There, the intelligent use of industrial waste heat and ground- at the core of our most efficient motors and fans allows efficiency of up water cooling, photovoltaics and, of course, our own cooling and venti - to 90%, saves energy at a very high level, significantly extends service lation technology are of the utmost importance. Our most modern plant, life and makes our products maintenance-free. These values pay off not for instance, consumes 91% less energy than currently specified and only for the environment, but every cent also pays off for the user! All required. In this way, our products contribute to protecting the environ- ebm-papst products – even those for which EC technology does not (yet) ment, from their origin to their recyclable packaging. make sense from an application viewpoint – feature the greatest possible connection of economy and ecology. 5 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:56 Seite 6 EC axial fans - HyBlade® Ø 500 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Max. operative range Perm. amb. temp. Mass without attachments VAC Hz rpm kW A Pa °C kg Type Motor *3G 500 M3G 084-GF 0° A 1~ 100-130 *3G 500 M3G 112-EA 0° B *3G 500 M3G 112-GA 0° C *3G 500 M3G 112-GA 0° D subject to alterations 50/60 1080 0,38 3,30 105 -25..+60 6,2 p. 36 / K1) 1~ 200-277 50/60 1420 0,75 3,40 175 -25..+60 7,2 p. 37 / L3) 3~ 200-240 50/60 1600 0,98 3,20 200 -25..+60 9,2 p. 35 / L2) 3~ 380-480 50/60 1600 0,98 1,60 200 -25..+60 9,2 p. 39 / K3) (1) Nominal data in operating point with maximum load and 115 VAC or 230 VAC or 400 VAC [Pa] 0,80 [in H2O] Curves 200 C Air performance measured D as per: ISO 5801, 4 in ebm-papst full nozzle 0,70 and without protection against 4 accidental contact 0,60 100 1 1080 0,26 2,26 72 2 1080 0,30 2,61 68 A 3 1080 0,33 2,87 65 A 4 1080 0,38 3,30 66 B 1 1420 0,55 2,51 78 B 2 1420 0,62 2,80 75 LwA as per ISO 13347, B 3 1420 0,68 3,03 73 LpA measured at 1 m distance B 4 1420 0,75 3,40 74 C 1 1600 0,73 2,32 80 C 2 1600 0,83 2,66 77 C 3 1600 0,91 2,82 75 C 4 1600 0,98 3,20 76 D 1 1600 0,73 1,16 80 D 2 1600 0,83 1,33 77 D 3 1600 0,91 1,41 75 D 4 1600 0,98 1,60 76 0,50 A The acoustic values given are 3 4 only valid under the measur- 0,30 may vary depending on the installation situation. 2 3 60 With any deviation to the stan- 0,20 2 dard setup, the specific values 40 have to be checked and re- 2 viewed once installed or fitted! 0,10 20 For detailed information 0 1000 2000 6 LwA [dB(A)] A ment conditions listed and 80 I [A] to fan axis 0,40 120 3 P1 [kW] Suction-side noise levels: 160 140 n [rpm] A Installation category A, B 180 Technical features and electr. connections Nominal voltage range Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Pressed-on round sheet steel plate, extrusion-coated in PP plastics Rotor: Coated in black Electronics enclosure: Die-cast aluminium, B C D coated in black additionally – Number of blades: 5 – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "B" ("F" applying to the main components as per EN) – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings 2000 1 4000 3000 4000 6000 1 5000 8000 1 6000 [CFM] 10000 [m /h] 3 see page 40 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:56 Seite 7 Direction of air flow – Technical features: See electrical connections p. 36 ff. – EMC: A B Interference emission acc. to EN 61000-6-3 C D Interference emission acc. to EN 61000-6-4 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: A B D Variable – Terminal box: C Electrical connection via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standards: CE – Approvals: GOST; UL/CSA are applied for; CCC on request ❮ "V" Without attachments ❮ "V" With full square nozzle ❮ "V" With guard grille for short nozzle "V" on request W3G 500-GD09 -41 on request "V" A3G 500-AM56 -21 W3G 500-GM56 -21 S3G 500-AM56 -21 "V" on request W3G 500-GN38 -13 on request "V" A3G 500-AN33 -01 W3G 500-GN33 -01 S3G 500-AN33 -01 Direction of air flow "A" on request 7 Drawings p. 8 ff. Electr. connections p. 35 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:56 Seite 8 EC axial fans - HyBlade® Ø 500 with motor M3G084, drawings for direction of air flow "V" Type Without attachments A 111±2 104.7±3 4xM6 on request Mass [kg] 6,2 Depth of screw 8-10 mm Internal diameter of the wall ring at least 503 mm 8 85 600+2 0 4x90˚ Ø497±1 Ø178 Ø150±0.25 Ø100 45˚ 47.7 160±2 Core-end sleeve Ø164±0.35 ❮ "V" With full square nozzle A Type Mass [kg] W3G 500-GD09 -41 12,2 Type Mass [kg] Ø11 Ø529 156.5±5 16 615±1 656-3 120 ❮ "V" With guard grille for short nozzle A on request 8,7 Ø565 Ø521.4 64±4 Internal diameter of the wall ring at least 503 mm Ø9 5 96 ❮ "V" 8 71,4±3 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:56 Seite 9 EC axial fans - HyBlade® Ø 500 with motor M3G112, drawings for direction of air flow "V" Type Without attachments B C 116±3 112±2 D 5x A3G 500-AM56 -21 on request A3G 500-AN33 -01 Mass [kg] g 7,2 160,5 9,2 180,5 9,2 180,5 ˚ Ø497±2 Ø200±1 Ø165±0.5 72 8 85 800+2 0 Internal diameter of the wall ring at least 503 mm 5xM6 56.5±0.6 g±2 Core-end sleeve Ø186±0.5 Depth of screw 12-16 mm ❮ "V" With full square nozzle B 171±5 C D Type Mass [kg] W3G 500-GM56 -21 W3G 500-GN38 -13 W3G 500-GN33 -01 17,2 Type Mass [kg] t S3G 500-AM56 -21 on request S3G 500-AN33 -01 10,5 52,0 12,5 72,0 12,5 72,0 19,2 19,2 Ø528 C Ø11 Cable gland 16 615±1 656-3 120 ❮ "V" With guard grille for short nozzle B C 64±4 Ø565 Ø521 D Internal diameter of the wall ring at least 503 mm 108.5±3 7 t±3 Ø9 ❮ "V" 9 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:57 Seite 10 EC axial fans - HyBlade® Ø 560 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Max. operative range Perm. amb. temp. Mass without attachments VAC Hz rpm kW A Pa °C kg Type Motor *3G 560 M3G 112-EA -5° A 1~ 200-277 *3G 560 M3G 112-GA -5° B *3G 560 M3G 112-GA -5° C subject to alterations 50/60 1000 0,40 1,80 100 -25..+60 9,3 p. 36 / K1) 3~ 200-240 50/60 1350 0,95 3,00 180 -25..+60 9,3 p. 35 / L2) 3~ 380-480 50/60 1350 0,95 1,50 180 -25..+60 9,3 p. 39 / K3) (1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC [in H2O] Air performance measured B C as per: ISO 5801, in ebm-papst full nozzle and without protection against 160 accidental contact 3 0,40 0,29 1,29 67 1000 0,34 1,48 66 A 3 1000 0,37 1,61 66 A 4 1000 0,40 1,80 68 1350 0,67 2,22 75 2 1350 0,78 2,50 74 LwA as per ISO 13347, B 3 1350 0,86 2,74 73 LpA measured at 1 m distance B 4 1350 0,95 3,00 77 C 1 1350 0,67 1,11 75 C 2 1350 0,78 1,25 74 C 3 1350 0,86 1,37 73 C 4 1350 0,95 1,50 77 0,30 ment conditions listed and may vary depending on the installation situation. 0,20 2 With any deviation to the standard setup, the specific values 40 have to be checked and re- 2 0,10 viewed once installed or fitted! For detailed information 0 1000 2000 10 1000 2 1 The acoustic values given are 3 20 1 A to fan axis 4 60 2000 4000 3000 4000 6000 1 5000 8000 LwA [dB(A)] B only valid under the measur- 80 I [A] B A 100 P1 [kW] Suction-side noise levels: 0,60 120 0,50 140 n [rpm] A Installation category A, 4 0,70 [Pa] Curves 180 Technical features and electr. connections Nominal voltage range Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics Rotor: Coated in black Electronics enclosure: Die-cast aluminium, coated in black – Number of blades: 5 – Direction of rotation: Counter-clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "B" ("F" applying to the main components as per EN) – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings 6000 1 [CFM] 10000 [m3/h] see page 40 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:57 Seite 11 Direction of air flow – Technical features: See electrical connections p. 36 ff. – EMC: B C Interference emission acc. to EN 61000-6-3 A Interference emission acc. to EN 61000-6-4 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: A C Variable – Terminal box: B Electrical connection via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standards: CE – Approvals: GOST; UL/CSA are applied for; CCC on request ❮ "V" Without attachments ❮ "V" With full square nozzle ❮ "V" With guard grille for short nozzle S3G 560-AP68 -21 A3G 560-AP68 -21 W3G 560-GP68 -21 "V" on request W3G 560-GQ49 -13 on request "V" A3G 560-AQ41 -01 W3G 560-GQ41 -01 S3G 560-AQ41 -01 "V" Direction of air flow "A" on request 11 Drawings p. 12 Electr. connections p. 35 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:57 Seite 12 EC axial fans - HyBlade® Ø 560 with motor M3G112, drawings for direction of air flow "V" Type Without attachments A B 134±3 115±2 C 5x A3G 560-AP68 -21 on request A3G 560-AQ41 -01 Mass [kg] g 7,2 180,5 9,3 200,5 9,3 200,5 ˚ Internal diameter of the wall ring at least 559 mm 8 85 800+ 20 Ø553±2 Ø200±1 Ø165±0.5 72 56.5±0.6 5xM6 g±2 Core-end sleeve Ø186 ±0.5 ❮ "V" Depth of screw 12-16 mm With full square nozzle A 182.5±5 B C Type Mass [kg] W3G 560-GP68 -21 W3G 560-GQ49 -13 W3G 560-GQ41 -01 18,9 Type Mass [kg] t S3G 560-AP68 -21 on request S3G 560-AQ41 -01 11,8 64 13,9 84 13,9 84 21,0 21,0 Ø625 B 16 Ø11 Cable gland 675±1 725-3 125 ❮ "V" With guard grille for short nozzle A 74±4 B 7 116 Ø9 t±3 ❮ "V" 12 Internal diameter of the wall ring at least 559 mm Ø700 Ø645 C EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:57 Seite 13 13 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:57 Seite 14 EC axial fans - HyBlade® Ø 630 kW A 800 0,28 2,40 Technical features and electr. connections rpm Mass without attachments Hz Perm. amb. temp. *3G 630 VAC Max. operative range *3G 630 Max. current draw (1) M3G 084-GF Max. power input (1) *3G 630 Speed/rpm (1) Motor Frequency Type Nominal voltage range Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades (5): A B C D E Pressed-on round sheet steel plate; F G Insertion part made of sheet aluminium; Both versions extrusion-coated in PP plastics Rotor: Coated in black Electronics enclosure: Die-cast aluminium, C D E F G coated in black additionally – Direction of rotation: A B C D E counter-clockwise, F G clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: A B C D E "B" ("F" applying to the main components as per EN), F G "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings Pa °C kg 75 -25..+60 6,3 p. 36 / K1) 0° A 1~ 100-130 50/60 M3G 084-GF 0° B 1~ 200-277 50/60 800 0,28 1,20 75 -25..+60 6,3 p. 36 / K1) M3G 112-GA -5° C 1~ 200-277 50/60 1000 0,72 3,20 140 -25..+60 9,3 p. 37 / L3) *3G 630 M3G 112-IA -5° D 3~ 200-240 50/60 1140 0,97 3,20 170 -25..+60 11,3 p. 35 / L2) *3G 630 M3G 112-IA -5° E 3~ 380-480 50/60 1140 0,97 1,60 170 -25..+60 11,3 p. 39 / K3) *3G 630 M3G 150-IF 0° F 3~ 200-240 50/60 1450 2,95 8,90 270 -25..+60 24,4 p. 38 / L5) *3G 630 M3G 150-IF 0° G 3~ 380-480 50/60 1510 3,20 5,00 290 -25..+65 24,4 p. 38 / L5) subject to alterations (1) Nominal data in operating point with maximum load and 115 VAC or 230 VAC or 400 VAC [Pa] [in H2O] Curves 4 F 800 0,18 1,64 65 2 800 0,23 2,04 63 A 3 800 0,27 2,34 63 A 4 800 0,28 2,40 66 B 1 800 0,18 0,82 65 B 2 800 0,23 1,02 63 LwA as per ISO 13347, B 3 800 0,27 1,17 63 LpA measured at 1 m distance B 4 800 0,28 1,20 66 C 1 1000 0,46 2,11 71 C 2 1000 0,55 2,51 68 C 3 1000 0,64 2,88 68 C 4 1000 0,72 3,20 71 D 1 1140 0,64 2,04 74 D 2 1140 0,78 2,50 71 D 3 1140 0,89 2,84 72 D 4 1140 0,97 3,20 74 in ebm-papst full nozzle 1,00 and without protection against 240 accidental contact 0,80 Suction-side noise levels: 200 D 3 E to fan axis 3 4 160 The acoustic values given are 0,60 C only valid under the measur4 ment conditions listed and 120 may vary depending on the 3 0,40 installation situation. 2 3 B 2 A 80 With any deviation to the stan4 dard setup, the specific values 0,20 2 40 3 have to be checked and re- 2 viewed once installed or fitted! 2 For detailed information 1 0 2000 4000 14 4000 1 6000 8000 12000 1 8000 10000 16000 LwA [dB(A)] 1 Installation category A, 4 I [A] A as per: ISO 5801, 280 P1 [kW] A Air performance measured G n [rpm] 1 1 12000 [CFM] 20000 [m /h] 3 see page 40 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:57 Seite 15 Direction of air flow – Technical features: See electrical connections p. 36 ff. – EMC: A B D E F G Interference emission acc. to EN 61000-6-3 C Interference emission acc. to EN 61000-6-4 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: A B C E Variable – Terminal box: D F G Electrical connection via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standards: CE – Approvals: A B C D E GOST; UL/CSA are applied for; CCC on request F G GOST, UL/CSA; CCC on request ❮ "V" Without attachments ❮ "V" With full square nozzle ❮ "V" With guard grille for short nozzle "V" on request W3G 630-GD10 -41 on request "V" A3G 630-AD03 -A1 W3G 630-GD03 -A1 S3G 630-AD03 -A1 "V" A3G 630-AQ37 -21 W3G 630-GQ37 -21 S3G 630-AQ37 -21 "V" on request W3G 630-GR92 -13 on request "V" A3G 630-AR85 -01 W3G 630-GR85 -01 S3G 630-AR85 -01 "V" on request W3G 630-GU29 -11 on request "V" A3G 630-AU23 -01 W3G 630-GU23 -01 S3G 630-AU23 -01 Direction of air flow "A" on request n [rpm] P1 [kW] I [A] LwA [dB(A)] E 1 1140 0,64 1,02 74 E 2 1140 0,78 1,25 71 E 3 1140 0,89 1,42 72 E 4 1140 0,97 1,60 74 F 1 1450 2,24 6,80 81 F 2 1450 2,45 7,50 80 F 3 1450 2,67 8,20 80 F 4 1450 2,95 8,90 84 G 1 1510 2,49 3,77 81 G 2 1510 2,74 4,18 81 G 3 1510 2,94 4,47 81 G 4 1510 3,20 5,00 85 15 Drawings p. 16 ff. Electr. connections p. 35 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:57 Seite 16 EC axial fans - HyBlade® Ø 630 with motor M3G084, drawings for direction of air flow "V" Type Without attachments A 112.3±2 93±3 4xM6 B 4x90˚ Ø626±1 Ø178 Ø150±0.25 Ø100 45˚ Depth of screw 8-10 mm on request A3G 630-AD03 -A1 Mass [kg] 6,3 6,3 8 85 600+20 Internal diameter of the wall ring at least 634 mm (47.7) Ø164±0.35 160 ±2 Core-end sleeve ❮ "V" With full square nozzle A 215±5 Mass [kg] W3G 630-GD10 -41 W3G 630-GD03 -A1 20,4 Type Mass [kg] on request S3G 630-AD03 -A1 10,6 20,4 Ø11 Ø726 B Type 20 750±1 805-3 142 ❮ "V" With guard grille for short nozzle A ❮ "V" 16 21,4±3 10,6 Internal diameter of the wall ring at least 634 mm Ø9 5 146 B Ø750 Ø701.4 20.7±4 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:57 Seite 17 EC axial fans - HyBlade® Ø 630 with motor M3G112, drawings for direction of air flow "V" Type Without attachments C D 144±3 123±2 E 5x A3G 630-AQ37 -21 on request A3G 630-AR85 -01 Mass [kg] g 9,3 180,5 11,3 200,5 11,3 200,5 ˚ Ø627±2 Ø200±1 Ø165±0.5 72 8 85 800+ 20 Internal diameter of the wall ring at least 634 mm 56.5±0.6 5xM6 g±2 Core-end sleeve Ø186±0.5 Depth of screw 12-16 mm ❮ "V" With full square nozzle C 209±5 D E Type Mass [kg] W3G 630-GQ37 -21 W3G 630-GR92 -13 W3G 630-GR85 -01 24,3 Type Mass [kg] t S3G 630-AQ37 -21 on request S3G 630-AR85 -01 14,6 39,5 16,6 59,5 16,6 59,5 26,3 26,3 Ø726 D Ø11 Cable gland 750±1 805-3 20 142 ❮ "V" With guard grille for short nozzle C D 60±4 7 141±3 Ø750 Ø701 E Internal diameter of the wall ring at least 634 mm Ø9 t±3 ❮ "V" 17 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:58 Seite 18 EC axial fans - HyBlade® Ø 630 with motor M3G150, drawings for direction of air flow "V" Without attachments F 184±3 145±2 14xM10 Depth of screw max. 25 mm G Type Mass [kg] on request A3G 630-AU23 -01 24,4 24,4 8x ˚ 45 Ø 627±2 22.5˚ 6x6 0˚ Internal diameter of the wall ring at least 634 mm 70 Ø232-2 Ø252±0.3 Ø275 250,5±1 Cable gland ❮ "V" With full square nozzle F 250±5 Mass [kg] W3G 630-GU29 -11 W3G 630-GU23 -01 39,5 Type Mass [kg] on request S3G 630-AU23 -01 31,5 39,5 Ø11 Ø696 G Type 20 750±1 805-3 150 ❮ "V" With guard grille for short nozzle F 76±4 72,5±3 ❮ "V" 18 31,5 Internal diameter of the wall ring at least 634 mm Ø10 4 178±3 Ø750 Ø717.2 G EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:58 Seite 19 19 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:58 Seite 20 EC axial fans - HyBlade® Ø 710 Nominal voltage range Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Max. operative range Perm. amb. temp. Mass without attachments VAC Hz rpm kW A Pa °C kg 1~ 200-277 50/60 830 0,70 3,10 100 -25..+60 12,0 p. 37 / L3) B 3~ 200-240 50/60 900 0,93 3,00 125 -25..+60 12,0 p. 35 / L2) C 3~ 380-480 50/60 900 0,93 1,50 125 -25..+60 12,0 p. 39 / K3) 0° D 3~ 200-240 50/60 1230 2,65 8,10 240 -25..+60 25,3 p. 38 / L5) 0° E 3~ 380-480 50/60 1250 2,83 4,30 240 -25..+60 25,3 p. 38 / L5) Curve Blade angle Nominal data Type Motor *3G 710 M3G 112-IA 0° A *3G 710 M3G 112-IA 0° *3G 710 M3G 112-IA 0° *3G 710 M3G 150-IF *3G 710 M3G 150-IF subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC [Pa] Air performance measured E D as per: ISO 5801, 4 4 in ebm-papst full nozzle and without protection against 180 0,80 accidental contact 3 3 0,70 200 0,60 160 0,50 4 830 0,45 2,08 69 2 830 0,55 2,49 67 A 3 830 0,64 2,86 68 A 4 830 0,70 3,10 73 1 900 0,59 1,92 70 B 2 900 0,70 2,28 69 LwA as per ISO 13347, B 3 900 0,81 2,60 70 LpA measured at 1 m distance B 4 900 0,93 3,00 76 C 1 900 0,59 0,96 70 C 2 900 0,70 1,12 69 C 3 900 0,81 1,30 70 C 4 900 0,93 1,50 76 D 1 1230 2,05 6,40 79 D 2 1230 2,33 7,20 78 D 3 1230 2,56 7,80 79 D 4 1230 2,65 8,10 83 E 1 1250 2,23 3,40 79 For detailed information E 2 1250 2,44 3,71 79 see page 40 ff. E 3 1250 2,67 4,06 79 E 4 1250 2,83 4,30 83 only valid under the measur- 0,40 ment conditions listed and 4 may vary depending on the 22 installation situation. 3 3 With any deviation to the stan- 0,20 dard setup, the specific values have to be checked and re- 2 40 2 0,10 viewed once installed or fitted! 1 0 2000 4000 20 1 B The acoustic values given are 60 20 LwA [dB(A)] Suction-side noise levels: C 0,30 80 I [A] A B A 100 P1 [kW] to fan axis 140 120 n [rpm] A Installation category A, 0,90 220 [in H2O] Curves 240 Technical features and electr. connections – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics Rotor: Coated in black Electronics enclosure: Die-cast aluminium, coated in black – Number of blades: 5 – Direction of rotation: A B C counter-clockwise, D E clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: A B C "B" ("F" applying to the main components as per EN), D E "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings 4000 8000 6000 8000 12000 1 10000 16000 12000 20000 11 14000 [CFM] 24000 [m /h] 3 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:58 Seite 21 Direction of air flow – Technical features: See electrical connections p. 37 ff. – EMC: B C D E Interference emission acc. to EN 61000-6-3 A Interference emission acc. to EN 61000-6-4 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: A C Variable – Terminal box: B D E Electrical connection via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standards: CE – Approvals: A B C GOST; UL/CSA are applied for; CCC on request D E GOST, UL/CSA; CCC on request ❮ "V" Without attachments ❮ "V" With full square nozzle ❮ "V" With guard grille for short nozzle S3G 710-AO85 -21 A3G 710-AO85 -21 W3G 710-GO85 -21 "V" on request W3G 710-GO87 -13 on request "V" A3G 710-AO81 -01 W3G 710-GO81 -01 S3G 710-AO81 -01 "V" on request W3G 710-GU30 -11 on request "V" A3G 710-AU21 -01 W3G 710-GU21 -01 S3G 710-AU21 -01 "V" Direction of air flow "A" on request 21 Drawings p. 22 ff. Electr. connections p. 35 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:58 Seite 22 EC axial fans - HyBlade® Ø 710 with motor M3G112, drawings for direction of air flow "V" Without attachments A B 153±3 135±2 C 5x Type Mass [kg] A3G 710-AO85 -21 on request A3G 710-AO81 -01 12,0 12,0 12,0 Ø703±2 Ø200±1 Ø165±0.5 72 ˚ 8 85 800+20 Internal diameter of the wall ring at least 710 mm 56.5 ±0.6 5xM6 Ø186±0.5 200,5 ±2 Core-end sleeve ❮ "V" Depth of screw 12-16 mm With full square nozzle A 219,5±5 B C Type Mass [kg] W3G 710-GO85 -21 W3G 710-GO87 -13 W3G 710-GO81 -01 26,9 Type Mass [kg] S3G 710-AO85 -21 on request S3G 710-AO81 -01 18,8 26,9 26,9 Ø792 B Ø11 Cable gland 20 810±1 850-3 160 ❮ "V" With guard grille for short nozzle A 41±4 B 7 169±3 ❮ "V" 22 Ø9 31,5±3 18,8 18,8 Internal diameter of the wall ring at least 710 mm Ø853 Ø799 C EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:58 Seite 23 EC axial fans - HyBlade® Ø 710 with motor M3G150, drawings for direction of air flow "V" Without attachments D Depth of screw max. 25 mm 184±3 145±2 E Type Mass [kg] on request A3G 710-AU21 -01 25,3 25,3 14xM10 8x ˚ 45 6x6 0˚ Ø 703 ±2 22.5˚ Internal diameter of the wall ring at least 710 mm Ø232-2 Ø252±0.3 Ø275 70 250,5±1 Cable gland ❮ "V" With full square nozzle D 284,5±5 Mass [kg] W3G 710-GU30 -11 W3G 710-GU21 -01 42,4 Type Mass [kg] on request S3G 710-AU21 -01 34,5 42,4 Ø14,5 Ø772 E Type 20 810±1 850-3 170 ❮ "V" With guard grille for short nozzle D E 34,5 Internal diameter of the wall ring at least 710 mm Ø853 Ø820.2 31±4 Ø10 4 27±3 223,5±3 ❮ "V" 23 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:59 Seite 24 EC axial fans - HyBlade® Ø 800 Nominal voltage range Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Max. operative range Perm. amb. temp. Mass without attachments VAC Hz rpm kW A Pa °C kg 1~ 200-277 50/60 710 0,73 3,20 100 -25..+60 12,1 p. 37 / L3) B 3~ 200-240 50/60 735 0,84 2,80 110 -25..+60 12,1 p. 35 / L2) C 3~ 380-480 50/60 735 0,84 1,40 110 -25..+60 12,1 p. 39 / K3) 0° D 3~ 200-240 50/60 1020 2,40 7,50 210 -25..+60 25,9 p. 38 / L5) 0° E 3~ 380-480 50/60 1020 2,56 3,90 230 -25..+60 25,9 p. 38 / L5) 0° F 3~ 200-240 50/60 1090 2,98 9,00 260 -25..+65 30,4 p. 38 / L5) 0° G 3~ 380-480 50/60 1090 2,98 4,50 260 -25..+65 30,4 p. 38 / L5) Curve Blade angle Nominal data Type Motor *3G 800 M3G 112-IA 0° A *3G 800 M3G 112-IA 0° *3G 800 M3G 112-IA 0° *3G 800 M3G 150-IF *3G 800 M3G 150-IF *3G 800 M3G 150-NA *3G 800 M3G 150-NA subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC Air performance measured [in H2O] [Pa] Curves 280 as per: ISO 5801, G F 1,00 in ebm-papst full nozzle and without protection against E 240 D accidental contact 4' 0,80 4 0,60 3 B 0,40 4 66 A 3 710 0,63 2,84 64 A 4 710 0,73 3,20 69 735 0,52 1,76 70 735 0,62 2,04 66 LwA as per ISO 13347, B 3 735 0,72 2,36 64 LpA measured at 1 m distance B 4 735 0,84 2,80 70 C 1 735 0,52 0,88 70 C 2 735 0,62 1,02 66 C 3 735 0,72 1,18 64 C 4 735 0,84 1,40 70 D 1 1020 1,62 4,94 75 D 2 1020 1,88 5,76 75 D 3 1020 2,15 6,58 77 D 4 1020 2,40 7,50 85 dard setup, the specific values 0,20 have to be checked and re- 40 viewed once installed or fitted! 2 2 For detailed information 24 70 2,49 With any deviation to the stan- 2 3 5000 2,15 0,55 2 installation situation. 3 4000 0,46 710 1 2 2000 710 2 B may vary depending on the 4 0 1 A ment conditions listed and 80 6000 10000 8000 15000 1 1 10000 12000 20000 LwA [dB(A)] B The acoustic values given are C A I [A] Suction-side noise levels: only valid under the measur- 120 P1 [kW] to fan axis 3 160 n [rpm] A Installation category A, 4 200 Technical features and electr. connections – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades (5): A B C Pressed-on round sheet steel plate; D E F G Insertion part made of sheet aluminium; Both versions extrusion-coated in PP plastics Rotor: Coated in black Electronics enclosure: Die-cast aluminium, coated in black – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: A B C "B" ("F" applying to the main components as per EN), D E F G "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings 14000 25000 1 1 16000 [CFM] [m3/h] see page 40 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:59 Seite 25 Direction of air flow – Technical features: See electrical connections p. 37 ff. – EMC: B C D E F G Interference emission acc. to EN 61000-6-3 A Interference emission acc. to EN 61000-6-4 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: A C Variable – Terminal box: B D E F G Electrical connection via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standards: CE – Approvals: A B C GOST; UL/CSA are applied for; CCC on request D E F G GOST, UL/CSA; CCC on request ❮ "V" Without attachments ❮ "V" With full square nozzle ❮ "V" With guard grille for full nozzle A3G 800-AO81 -21 W3G 800-GO81 -21 "V" on request W3G 800-GO91 -13 on request "V" A3G 800-AO84 -01 W3G 800-GO84 -01 S3G 800-BO84 -01 "V" on request W3G 800-GU24 -11 on request "V" A3G 800-AU25 -01 W3G 800-GU25 -01 S3G 800-BU25 -01 "V" on request W3G 800-GV10 -11 on request A3G 800-AV01 -01 W3G 800-GV01 -01 S3G 800-BV01 -01 "V" "V" S3G 800-BO81 -21 Direction of air flow "A" on request n [rpm] P1 [kW] I [A] LwA [dB(A)] E 1 1020 1,62 2,47 75 E 2 1020 1,88 2,88 75 E 3 1020 2,15 3,29 77 E 4’ 1020 2,56 3,90 85 F 1 1090 1,87 5,68 76 F 2 1090 2,18 6,64 76 F 3 1090 2,50 7,62 78 F 4 1090 2,98 9,00 84 G 1 1090 1,87 2,84 76 G 2 1090 2,18 3,32 76 G 3 1090 2,50 3,81 78 G 4 1090 2,98 4,50 84 25 Drawings p. 26 ff. Electr. connections p. 35 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:59 Seite 26 EC axial fans - HyBlade® Ø 800 with motor M3G112, drawings for direction of air flow "V" Without attachments A B 126±3 131±2 C 5x Type Mass [kg] A3G 800-AO81 -21 on request A3G 800-AO84 -01 12,1 12,1 12,1 ˚ Ø786±2 Ø200±1 Ø165±0.5 72 8 85 800 +20 Internal diameter of the wall ring at least 795 mm 56.5±0.6 5xM6 Ø186±0.5 200,5±2 Core-end sleeve Depth of screw 12-16 mm ❮ "V" With full square nozzle A 236.5±5 B C Type Mass [kg] W3G 800-GO81 -21 W3G 800-GO91 -13 W3G 800-GO84 -01 33,3 Type Mass [kg] S3G 800-BO81 -21 on request S3G 800-BO84 -01 18,3 33,3 33,3 Ø857 B Ø14.5 Cable gland 910±1 970-3 17 190 ❮ "V" With guard grille for full nozzle A X 126±4 X 92 B 18,3 18,3 26 15 7.5 C 15.5 66 144±3 ❮ "V" 26 Ø860 Ø816+2 68 Internal diameter of the wall ring at least 795 mm EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:59 Seite 27 EC axial fans - HyBlade® Ø 800 with motor M3G150, drawings for direction of air flow "V" Without attachments D 189±3 148±2 Depth of screw max. 25 mm 14xM10 E F G Type Mass [kg] on request A3G 800-AU25 -01 on request A3G 800-AV01 -01 25,9 250,5 g 25,9 250,5 30,4 289,5 30,4 289,5 ˚ 45 8x Ø788±2 22.5˚ 6x6 0˚ Internal diameter of the wall ring at least 795 mm 70 Ø232-2 Ø252±0.3 Ø275 g ±1 Cable gland ❮ "V" Type With full square nozzle D 307±5 E F -11 -01 -11 -01 45,7 45,7 50,2 50,2 Ø14.5 Ø857 G W3G 800-GU24 W3G 800-GU25 W3G 800-GV10 W3G 800-GV01 Mass [kg] 910±1 970-3 17 190 ❮ "V" With guard grille for full nozzle D X 132±4 92 X E 15 26 7.5 F G Type Mass [kg] on request S3G 800-BU25 -01 on request S3G 800-BV01 -01 33,7 124,0 t 33,7 124,0 38,2 163,0 38,2 163,0 15.5 Ø816+2 Ø860 68 126,5±3 Internal diameter of the wall ring at least 795 mm t±3 ❮ "V" 27 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:59 Seite 28 EC axial fans - HyBlade® Ø 910 Max. operative range Perm. amb. temp. Mass without attachments 12,2 p. 37 / L3) 2,20 85 -25..+60 12,2 p. 35 / L2) 1,10 85 -25..+60 12,2 p. 39 / K3) 2,10 6,40 160 -25..+60 26,4 p. 38 / L5) 2,10 3,20 160 -25..+60 26,4 p. 38 / L5) 960 2,47 7,60 170 -25..+60 30,9 p. 38 / L5) 1000 2,88 4,40 190 -25..+65 30,9 p. 38 / L5) Max. current draw (1) -25..+60 Max. power input (1) 80 Speed/rpm (1) kg Frequency °C Nominal voltage range Pa VAC Hz rpm kW A 1~ 200-277 50/60 590 0,58 2,60 B 3~ 200-240 50/60 610 0,63 C 3~ 380-480 50/60 610 0,63 0° D 3~ 200-240 50/60 885 0° E 3~ 380-480 50/60 885 0° F 3~ 200-240 50/60 0° G 3~ 380-480 50/60 Curve Blade angle Nominal data Type Motor *3G 910 M3G 112-IA 0° A *3G 910 M3G 112-IA 0° *3G 910 M3G 112-IA 0° *3G 910 M3G 150-IF *3G 910 M3G 150-IF *3G 910 M3G 150-NA *3G 910 M3G 150-NA subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC Curves Air performance measured 4 as per: ISO 5801, F 0,70 [Pa] [in H2O] G 180 E 160 in ebm-papst full nozzle and without protection against 4 0,60 accidental contact 140 0,50 3 1 590 0,35 1,64 67 A 2 590 0,43 1,97 66 A 3 590 0,50 2,26 66 A 4 590 0,58 2,60 71 1 610 0,39 1,38 68 B 2 610 0,48 1,40 67 LwA as per ISO 13347, B 3 610 0,56 1,84 66 LpA measured at 1 m distance B 4 610 0,63 2,20 70 C 1 610 0,39 0,69 68 C 2 610 0,48 0,80 67 C 3 610 0,56 0,92 66 C 4 610 0,63 1,10 70 D 1 885 1,36 4,14 76 D 2 885 1,60 4,86 75 D 3 885 1,83 5,58 75 D 4 885 2,10 6,40 78 0,40 The acoustic values given are B C only valid under the measur4 ment conditions listed and 0,30 4 may vary depending on the 2 60 0,20 3 2 3 installation situation. 2 With any deviation to the standard setup, the specific values 40 have to be checked and re0,10 2 2 viewed once installed or fitted! For detailed information 1 1 0 5000 5000 28 LwA [dB(A)] to fan axis A 20 I [A] B 3 80 P1 [kW] Suction-side noise levels: 3 100 n [rpm] A Installation category A, 4 D 120 Technical features and electr. connections – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades (5): A B C Pressed-on round sheet steel plate; D E F G Insertion part made of sheet aluminium; Both versions extrusion-coated in PP plastics Rotor: Coated in black Electronics enclosure: Die-cast aluminium, coated in black – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: A B C "B" ("F" applying to the main components as per EN), D E F G "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings 10000 10000 15000 1 15000 20000 25000 30000 1 1 [CFM] [m3/h] see page 40 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:59 Seite 29 Direction of air flow – Technical features: See electrical connections p. 37 ff. – EMC: B C D E F G Interference emission acc. to EN 61000-6-3 A Interference emission acc. to EN 61000-6-4 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Cable exit: A C Variable – Terminal box: B D E F G Electrical connection via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standards: CE – Approvals: A B C GOST; UL/CSA are applied for; CCC on request D E F G GOST, UL/CSA; CCC on request ❮ "V" Without attachments ❮ "V" With full square nozzle ❮ "V" With guard grille for full nozzle A3G 910-AO84 -21 W3G 910-GO84 -21 "V" on request W3G 910-GO90 -13 on request "V" A3G 910-AO83 -01 W3G 910-GO83 -01 S3G 910-BO83 -01 "V" on request W3G 910-GU31 -11 on request "V" A3G 910-AU22 -01 W3G 910-GU22 -01 S3G 910-BU22 -01 "V" on request W3G 910-GV06 -11 on request A3G 910-AV02 -01 W3G 910-GV02 -01 S3G 910-BV02 -01 "V" "V" S3G 910-BO84 -21 Direction of air flow "A" on request n [rpm] P1 [kW] I [A] LwA [dB(A)] E 1 885 1,36 2,07 76 E 2 885 1,60 2,43 75 E 3 885 1,83 2,79 75 E 4 885 2,10 3,20 78 F 1 960 1,64 5,00 78 F 2 960 1,94 6,00 77 F 3 960 2,21 6,80 77 F 4 960 2,47 7,60 80 G 1 1000 1,92 2,91 79 G 2 1000 2,29 3,49 78 G 3 1000 2,60 3,97 79 G 4 1000 2,88 4,40 82 29 Drawings p. 30 ff. Electr. connections p. 35 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 09:59 Seite 30 EC axial fans - HyBlade® Ø 910 with motor M3G112, drawings for direction of air flow "V" Without attachments A 139±3 114±2 B 5x C Type Mass [kg] A3G 910-AO84 -21 on request A3G 910-AO83 -01 12,2 12,2 12,2 ˚ Internal diameter of the wall ring at least 913 mm 8 85 800 +20 Ø905±2 Ø200±1 Ø165±0.5 72 56.5±0.6 5xM6 Ø186±0.5 200,5±2 Core-end sleeve Depth of screw 12-16 mm ❮ "V" With full square nozzle A 266.5±5 B C Type Mass [kg] W3G 910-GO84 -21 W3G 910-GO90 -13 W3G 910-GO83 -01 37,0 Type Mass [kg] S3G 910-BO84 -21 on request S3G 910-BO83 -01 19,8 37,0 37,0 Ø976 B Ø14.5 Cable gland 20 205 1010±1 1070-3 ❮ "V" With guard grille for full nozzle A X 135±4 X 106 B 19,8 19,8 26 15.8 10.5 C 22 70 140±3 ❮ "V" 30 Ø976 Ø932+2 74 Internal diameter of the wall ring at least 913 mm EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 31 EC axial fans - HyBlade® Ø 910 with motor M3G150, drawings for direction of air flow "V" Without attachments D 188±3 115±2 14xM10 Depth of screw max. 25 mm E F G 8x Type Mass [kg] on request A3G 910-AU22 -01 on request A3G 910-AV02 -01 26,4 250,0 g 26,4 250,5 30,9 289,5 30,9 289,5 45 ˚ 22.5˚ 6x6 0˚ Ø905±2 Internal diameter of the wall ring at least 913 mm 70 Ø232-2 Ø252±0.3 Ø275 g±1 Cable gland ❮ "V" Type With full square nozzle D 307±5 E F -11 -01 -11 -01 51,6 51,6 56,1 56,1 Ø14.5 Ø976 G W3G 910-GU31 W3G 910-GU22 W3G 910-GV06 W3G 910-GV02 Mass [kg] 20 1010±1 1070-3 205 ❮ "V" With guard grille for full nozzle D X 137±4 X 106 E 15.8 26 10.5 F G Type Mass [kg] on request S3G 910-BU22 -01 on request S3G 910-BV02 -01 35,2 137,5 t 35,2 137,5 39,7 176,5 39,7 176,5 22 113±3 Ø983 Ø931+2 74 Internal diameter of the wall ring at least 913 mm t±3 ❮ "V" 31 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 32 EC axial fans - HyBlade® Ø 990 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Max. operative range Perm. amb. temp. Mass without attachments VAC Hz rpm kW A Pa °C kg 3~ 200-240 50/60 820 1,64 5,00 135 -25..+60 25,7 p. 38 / L5) B 3~ 380-480 50/60 820 1,64 2,50 135 -25..+60 25,7 p. 38 / L5) C 3~ 200-240 50/60 960 2,58 8,00 180 -25..+65 31,2 p. 38 / L5) D 3~ 380-480 50/60 960 2,58 4,00 180 -25..+70 31,2 p. 38 / L5) Type Motor *3G 990 M3G 150-IF -5° A *3G 990 M3G 150-IF -5° *3G 990 M3G 150-NA -5° *3G 990 M3G 150-NA -5° subject to alterations (1) Nominal data in operating point with maximum load and 400 VAC [in H2O] Air performance measured C D as per: ISO 5801, in ebm-papst full nozzle and without protection against 160 0,60 accidental contact 100 3 820 0,98 2,98 80 2 820 1,22 3,70 78 A 3 820 1,46 4,46 78 A 4 820 1,64 5,00 79 1 820 0,98 1,49 80 B 2 820 1,22 1,85 78 LwA as per ISO 13347, B 3 820 1,46 2,23 78 LpA measured at 1 m distance B 4 820 1,64 2,50 79 C 1 960 1,49 4,54 85 C 2 960 1,90 5,76 83 C 3 960 2,26 6,86 84 C 4 960 2,58 8,00 85 D 1 960 1,49 2,27 85 D 2 960 1,90 2,88 83 D 3 960 2,26 3,43 84 D 4 960 2,58 4,00 85 only valid under the measur- 0,30 ment conditions listed and may vary depending on the 60 0,20 2 With any deviation to the stan2 dard setup, the specific values 40 have to be checked and re0,10 viewed once installed or fitted! For detailed information 1 0 5000 5000 32 1 B installation situation. 20 10000 10000 15000 15000 20000 25000 LwA [dB(A)] Suction-side noise levels: The acoustic values given are 3 80 I [A] to fan axis 0,40 120 0,50 4 P1 [kW] A B A 140 n [rpm] A Installation category A, 4 0,70 [Pa] Curves 180 Technical features and electr. connections Nominal voltage range Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics Rotor: Coated in black Electronics enclosure: Die-cast aluminium, coated in black – Number of blades: 5 – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharges: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings 30000 1 [CFM] [m3/h] see page 40 ff. EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 33 Direction of air flow – Technical features: See electrical connections p. 38 – EMC: Interference emission acc. to EN 61000-6-3 Interference immunity acc. to EN 61000-6-2 Harmonics acc. to EN 61000-3-2/3 – Leakage current: < 3.5 mA acc. to EN 61800-5-1 – Terminal box: Electrical connection via terminal strip – Protection class: I (acc. to EN 61800-5-1) – Product conforming to standards: CE – Approvals: A B C D GOST; UL/CSA; CCC on request ❮ "V" Without attachments ❮ "V" With full square nozzle ❮ "V" With guard grille for full nozzle "V" on request W3G 990-GY32 -11 on request "V" A3G 990-AY28 -01 W3G 990-GY28 -01 S3G 990-BY28 -01 "V" on request W3G 990-GZ09 -11 on request "V" A3G 990-AZ02 -01 W3G 990-GZ02 -01 S3G 990-BZ02 -01 Direction of air flow "A" on request 33 Drawings p. 34 Electr. connections p. 38 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 34 EC axial fans - HyBlade® Ø 990 with motor M3G150, drawings for direction of air flow "V" Without attachments A 175±3 106±2 14xM10 Depth of screw max. 25 mm B C Mass [kg] on request A3G 990-AY28 -01 on request A3G 990-AZ02 -01 25,7 238,0 g h 57,5 25,7 238,0 57,5 31,2 289,5 70,0 31,2 289,5 70,0 45 8x D Type ˚ 6x6 0˚ Ø990±2 22,5˚ Internal diameter of the wall ring at least 1000 mm h Ø232-2 Ø252±0,3 Ø275 g±1 Cable gland ❮ "V" Type With full square nozzle A u±5 B C -11 -01 -11 -01 u 55,9 323,5 55,9 323,5 61,4 336,0 61,4 336,0 Ø14.5 Ø1063 D W3G 990-GY32 W3G 990-GY28 W3G 990-GZ09 W3G 990-GZ02 Mass [kg] 20 1110±1 1170-3 225 ❮ "V" With guard grille for full nozzle A 129±4 106 X X B 15.8 26 10.5 C D Type Mass [kg] on request S3G 990-BY28 -01 on request S3G 990-BZ02 -01 35,7 103,5 134,5 41,2 116,0 173,5 41,2 116,0 173,5 22 Ø1018+2 Ø1070 t±3 ❮ "V" 34 t 35,7 103,5 134,5 74 s±3 s Internal diameter of the wall ring at least 1000 mm EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 35 Electrical connections EC L2) Alarm relay Line undervoltage detection Phase failure detection Motor current limitation Electronics / motor overtemperature protection Locked-rotor protection Soft start L1 PE KL1 NC COM NO OUT GND +10 V 0-10 V PWM +20 V KL2 4-20 mA 0-10 V PWM GND RS A RS B RS B RS A KL3 L3 • • • • • • • L2 Technical features: • PFC (passive) • Integrated PID controller • Control input 0-10 VDC / PWM • Input for sensor 0-10 V or 4-20 mA • Slave output 0-10 V max. 3 mA • Output 20 VDC (±20 %) max. 50 mA • Output 10 VDC (+10 %) max. 10 mA • RS485 ebmBUS Connector Connection Assignment / function Connector Connection Assignment / function PE PE Protective earth KL3 OUT Master output 0-10 V max. 3 mA KL1 L3 Mains; L3 GND GND L2 Mains; L2 0-10 V / PWM Control / Actual value input (Impedance 100 kΩ) L1 Mains; L1 +10 V NC Alarm relay, break for failure COM Alarm relay, COMMON (2A, 250 VAC, AC1) NO Alarm relay, make for failure KL2 Supply for external potentiometer, 10 VDC (+10 %) max. 10 mA +20 V Supply for external sensor, 20 VDC (±20 %) max. 50 mA 4-20 mA Control / Actual value input 0-10 V / PWM Control / Actual value input GND GND RSB RS485 interface for ebmBUS; RS B RSA RS485 interface for ebmBUS; RS A RSB RS485 interface for ebmBUS; RS B RSA RS485 interface for ebmBUS; RS A 35 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 36 Electrical connections EC K1) Technical features: • Control input 0-10 VDC / PWM • Output 10 VDC max. 1.1 mA • Alarm relay • Electronics / motor overtemperature protection • Line undervoltage detection • Motor current limitation • Locked-rotor protection • Soft start Notes on various control possibilities and their applications Umin = 15 V Imax = 10 mA Mains 50/60 Hz U - 10 K + - NC white1 COM white2 Voltage output red +10 V max. 1.1 mA + PWM L black N blue PE green/yellow 12 V Alarm relay: Break for failure (2 A, 250 VAC, AC1) Lin/PWM control input yellow 0-10 VDC / PWM 1 μF GND blue Speed setting PWM 1 - 10 kHz Speed setting with variable resistance Full speed Speed setting 1 V - 10 V 100% PWM -> n=max approx. 10% PWM -> n=min < 10% PWM -> n=0 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 start up at > 14% start up at > 1.4 V Customer circuit Connection +10 V 0-10 V PWM GND green/yellow white1 COM blue Line 2 NC N black PE L Line 1 Fan white2 red yellow blue Line Connection Colour Assignment / function Line 1 L black Mains 50/60 Hz, phase 2 N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Control input (Impedance 100 kΩ) PE green/yel Protective earth GND GND NC white1 Alarm relay, break for failure COM white2 Alarm relay, COMMON 36 Connection Colour Assignment / function +10 V red blue Voltage output +10 V max. 1.1 mA EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 37 Electrical connections EC L3) Technical features: • PFC (active) • Control input 0-10 VDC / PWM • Output 10 VDC max. 10 mA • Alarm relay • Electronics / motor overtemperature protection • Line undervoltage detection • Motor current limitation • Locked-rotor protection, soft start Full speed Speed setting 8 8 PE 2 PE1 1-10 V 11 12 N AC1 P L AC2 N 3 10 V -> n = max 1 V -> n = min <1 V -> n = 0 4 COM 5 A1 11 10 A (T) 14 A2 NC 6 0-10 V 0-10 V 8 Speed setting with potentiometer 47 K 47 K 470 nF 10 V 10 V 11 11 10 Imax=10 mA GND 12 0V 8 10 K 12 Customer circuit Connection Fan N L COM NC 0-10 V +10 V GND Line 2 PE Line 1 green/yellow blue black white1 white2 yellow red blue Line Pin Connection Colour Assignment / function 1 2 PE green/yellow Protective earth 1 3 N blue Mains 50/60 Hz, neutral 1 4 L black Mains 50/60 Hz, phase 1 5 COM white1 Alarm relay, COMMON (2A, max. 250 VAC, min. 10 mA, AC1) 1 6 NC white2 Alarm relay, break for failure 2 8 0-10 V yellow Control input (Impedance 100 kΩ), SELV 2 11 +10 V red Voltage output 10 VDC (+/- 3%), max. 10 mA, supply voltage for external units (e.g. potentiometer), SELV 2 12 GND blue GND, SELV 37 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 38 Electrical connections EC L5) RS485 MODBUS Motor current limitation, alarm relay Line undervoltage / phase failure detection Electronics / motor overtemperature protection Locked-rotor protection, soft start Digital inputs for day/night switch, enabling, cooling / heating L3 L2 Aout Din1 L1 Ain2 I Ain1 I KL1 PE +20 V +10 V NO GND Ain2 U GND Din3 RS B KL2 Ain1 U Din2 RS A KL3 NC • • • • • • COM Technical features: • PFC (passive) • Integrated PID controller • Control input 0-10 VDC or 4-20 mA • Input for sensor 0-10 V or 4-20 mA • Slave output 0-10 V max. 5 mA • Output 20 VDC (+25 % / -10 %) max. 50 mA • Output 10 VDC (+3 %) max. 10 mA Connector Connection Assignment / function Connector Connection Assignment / function KL1 KL3 L3 Mains; L3 L2 Mains; L2 L1 Mains; L1 PE PE Protective earth KL2 NC Alarm relay, break for failure COM Alarm relay, COMMON (2A, 250 VAC, AC1) NO Alarm relay, make for failure Din1 Digital input 1 (enabling / disabling of electronics),, Enabling: Pin open or applied voltage 5...50 VDC Disabling: Bridge to GND or applied voltage < 1 VDC Ain1 I Analogue set value input, 4-20 mA (impedance 100 Ω), only to be used as alternative to terminal Ain1 U +10 V Supply for external potentiometer, 10 VDC (±3 %) max. 10 mA Ain1U Analogue set value input, 0-10 V (impedance 100 kΩ), GND GND RSB RS485 interface for MODBUS RTU; RS B RSA RS485 interface for MODBUS RTU; RS A Aout Analogue output 0-10 V max. 5 mA, reading of current only to be used as alternative to terminal Ain1 I motor speed / current motor control factor Ain2 I Analog. actual value input, 4-20mA (impedance 100Ω), +20 V Supply for external sensor, only to be used as alternative to terminal Ain2 U 20 VDC (+25 % / -10%) max. 40 mA Ain2 U Analog. actual value input, 0-10 V (impedance 100 kΩ), only to be used as alternative to terminal Ain2 I GND GND Din3 Digital input 3 (switch Normal / Inverse), The preset effective direction of the integrated controller can be selected via BUS or via digital input Normal/Inverse. Normal: Pin open or applied voltage 5...50 VDC Inverse: Bridge to GND or applied voltage < 1 VDC Din2 Digital input 2 (switch Day / Night), The preset set of parameters can be selected via BUS or via digital input Day/Night. Day: Pin open or applied voltage 5...50 VDC Night: Bridge to GND or applied voltage < 1 VDC 38 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 39 Electrical connections EC K3) Technical features: • PFC (passive) • Control input 0-10 VDC / PWM • Output 10 VDC (±20 %) max. 10 mA • Alarm relay • Electronics / motor overtemperature protection • Line undervoltage / phase failure detection • Motor current limitation • Locked-rotor protection, soft start Notes on various control possibilities and their applications Umin = 15 V L1 Imax = 10 mA Mains 50/60 Hz + - L2 black L3 black black PE green/yellow NC white1 COM white2 Voltage output red +10 V max. 10 mA + U PWM - 10 K 12 V Alarm relay: Break for failure (2 A, 250 VAC, AC1) Lin/PWM control input yellow 0-10 VDC / PWM 1 μF GND blue Speed setting PWM 1 - 10 kHz Speed setting with variable resistance Full speed Speed setting 1 V - 10 V 100% PWM -> n=max approx. 10% PWM -> n=min < 10% PWM -> n=0 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 start up at > 14% start up at > 1,4 V Customer circuit Connection +10 V 0-10 V PWM GND black green/yellow white1 COM NC black Line 2 PE L2 black L3 L1 Line 1 Fan white2 red yellow blue Line Connection Colour Assignment / function Line Connection Colour Assignment / function 1 L1 black Mains; L1 2 +10 V L2 black Mains; L2 0-10 V / PWM yellow Control input (Impedance 100 kΩ) L3 black Mains; L3 GND GND PE green/yel Protective earth NC white1 Alarm relay, break for failure COM white2 Alarm relay, COMMON red blue Voltage output +10 V max. 1.1 mA 39 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 40 Technical parameters & scope High standards for all ebm-papst products Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best possible product for your application. Careful monitoring of the market ensures that technical innovations are reflected in the improvements of our products. Based on the technical parameters listed below and the ambience you want our product to operate in, we here at ebm-papst can always work out the best solution for your specific application. General performance parameters Service life Any deviations from the technical data and parameters described here The service life of ebm-papst products depends on two major factors: are listed on the product-specific data sheet. – The service life of the insulation system – The service life of the bearing system Type of protection The service life of the insulation system mainly depends on voltage level, The type of protection is specified in the product-specific data sheets. temperature and ambient conditions, such as humidity and condensation. The service life of the bearing system depends mainly on the thermal load Insulation class on the bearing. The insulation class is specified in the product-specific data sheets. The majority of our products use maintenance-free ball bearings for any mounting position possible. As an option, sleeve bearings can be Mounting position used, which is indicated on the product-specific data sheet wherever The mounting position is specified in the product-specific data sheets. applicable. The service life L10 of the ball bearings can be taken as approx. 40,000 Condensate discharge holes operating hours at an ambient temperature of 40 °C, yet this estimate Information on the condensate discharge holes is provided in the can vary according to the actual ambient conditions. product-specific data sheets. We will gladly provide you with a lifetime calculation taking into account your specific operating conditions. Mode of operation The mode of operation is specified in the product-specific data sheets. Motor protection / thermal protection Information on motor protection and thermal protection is provided in the Protection class product-specific data sheets. The protection class is specified in the product-specific data sheets.. Depending on motor type and field of application, the following protective features are realised: – Thermal overload protection (TOP), either in-circuit or external – PTC with electronic diagnostics – Impedance protection – Thermal overload protection (TOP) with electronic diagnostics – Current limitation via electronics If an external TOP is connected, the customer has to make sure to connect a conventional trigger device for switching it off. Products without fitted TOP and without protection against improper use, a motor protection complying with the valid standards has to be installed. 40 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:00 Seite 41 Left: Endurance test room Middle: Shock test Right: Chamber test rig Mechanical strain / performance parameters Legal and normative directives All ebm-papst products are subjected to comprehensive tests complying The products described in this catalogue are designed, developed and with the normative specifications. In addition to this, the tests also reflect produced in keeping with the standards in place for the relevant product the vast experience and expertise of ebm-papst. and, if known, the conditions governing the relevant fields of application. Vibration test Standards Vibration tests are carried out in compliance with Information on standards is provided in the product-specific data sheets. – Vibration test in operation according to DIN IEC 68, parts 2-6 – Vibration test at standstill according to DIN IEC 68, parts 2-6 EMC Information on EMC standards is provided in the product-specific data Shock load sheets. Shock load tests are carried out in compliance with Complying with the EMC standards has to be established on the final – Shock load according to DIN IEC 68, parts 2-27 appliance, as different mounting situations can result in changed EMC properties. Balancing quality Testing the balancing quality is carried out in compliance with Leakage current – Residual imbalance according to DIN ISO 1940 Information on the leakage current is provided in the product-specific – Standard balancing quality level G 6.3 data sheets. Should you require a higher balancing quality level for your specific Measuring is according to IEC 60990. application, please let us know and specify this when ordering your product. Approvals In case you require a specific approval for your ebm-papst product Chemo-physical strain / performance parameters (VDE, UL, GOST, CCC, CSA, etc.) please let us know. Should you have questions about chemo-physical strain, please direct Most of our products can be supplied with the relevant approval. them to your ebm-papst contact. Information on existing approvals is provided in the product-specific data sheets. Fields of application, industries and applications Our products are used in various industries and applications: Air performance measurements Ventilation, air-conditioning and refrigeration technology, clean room All air performance measurements are carried out on suction side and on technology, automotive and rail technology, medical and laboratory tech- chamber test beds conforming to the specifications as per ISO 5801 and nology, electronics, computer and office technology, telecommunications, DIN 24163. The fans under test are installed in the measuring chamber at household appliances, heating, machines and plants, drive engineering. free air intake and exhaust (installation category A) and are operated at Our products are not designed for use in the aviation and aerospace nominal voltage, with AC also at nominal frequency, and without any industry! additional components such as guard grilles. As required by the standard, the air performance curves correspond to an air density of 1.2 kg/m3. 41 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:01 Seite 42 Room for precision noise measuring Measurement conditions for air and noise measurement ebm-papst products are measured under the following conditions: – Axial and diagonal fans in direction of rotation “V” in full nozzle and without guard grille – Backward curved centrifugal fans, free-running and with inlet nozzle – Forward curved single and dual inlet centrifugal fans with housing Noise measurements All noise measurements are carried out in low-reflective test rooms with reverberant floor. Thus the ebm-papst acoustic test chambers meet the requirements of precision class 1 according to DIN EN ISO 3745. For noise measurement, the fans being tested are placed in a reverberant wall and operated at nominal voltage (for AC, also at nominal frequency) without additional attachments such as the guard grille. Sound pressure level and sound level All acoustic values are established according to ISO 13347, DIN 45635 and ISO 3744/3745 to accuracy class 2 and given in A-rated form. When the sound pressure level (Lp) is measured, the microphone is on the intake side of the fan being tested, usually at a distance of 1 m on the fan axis. To measure the sound level (Lw), 10 microphones are distributed over an enveloping surface on the intake side of the fan being tested 1,5d (see graphic). The sound level measured can be roughly calculated D from the sound pressure level by adding 7 dB. Measuring configuration as per ISO 13347-3 respectively DIN 45635-38: 10 measuring points h 3d d≥D h = 1,5d ... 4,5d Measurement area S = 6d2 + 7d (h + 1,5d) 42 2d 10:01 Seite 43 Adding multiple noise sources with the same level 15 16.05.2011 [dB] EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage pressure level of a fan is approximately 75 dB(A). The level increase measured from the diagram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A). 10 9 Example: 8 A3G800 axial fans are on a condenser. According to the data sheet, the sound 5 the noise values specified in the data sheet. This is shown in the diagram opposite. 0 The noise characteristics of multiple identical fans can be determined in advance based on Increase in sound pressure / sound power level Adding 2 noise sources with the same volume results in a level increase of approx. 3 dB. 1 2 5 8 10 15 20 25 3 Adding two noise sources with different levels [dB] Number of sources of sound with identical level 4 dB. The level increase can now be read in the diagram as approx. 1.5 dB. This means that the overall sound level of the unit can be expected to be 76.5 dB(A). 2 1,5 ating point and an axial fan A3G710 with 71 dB(A) in a ventilation unit. The level difference is 1 Example: There is an axial fan A3G800 with a sound pressure level of 75 dB(A) at the oper- 0 levels given in the data sheet. This is shown in the diagram opposite. Increase in sound pressure / sound power level The acoustic performance of two different fans can be predetermined based on the sound 0 4 8 12 16 20 24 [dB] 0 Distance laws [dB] Difference in level with two sources of sound Sound power level is independent of distance to the sound source. In contrast to this, sound -10 pressure level decreases the further away the noise source is. The adjacent diagram shows the decrease in level under far sound field conditions. Far sound field conditions apply when- decreases by 6 dB. In the near field of the fan, other correlations apply and the decrease in levels can be considerably smaller. The following example only applies to far sound field conditions and can vary strongly depending on the installation effects: With an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of 1 m. According to the adjacent diagram, at a distance of 20 m we would get a reduction by -20 -26 -30 vant literature on this complex topic. Per doubling of distance, the level in the far sound field -40 wavelength to be considered. For more information on far sound field, please consult the rele- Decrease in sound pressure level ever the distance between microphone and fan is big when compared to fan diameter and 1 Distance 2 5 10 20 50 100 [m] 26 dB, i.e. a sound pressure level of 39 dB(A). 43 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage fan agent compact fan agent 16.05.2011 10:01 Seite 44 ebm-papst in Germany motor specialist motor agent Germany ebm-papst Mulfingen GmbH & Co. KG ebm-papst St. Georgen GmbH & Co. KG ebm-papst Landshut GmbH Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 [email protected] Hermann-Papst-Straße 1 D-78112 St. Georgen Phone +49 7724 81-0 Fax +49 7724 81-1309 [email protected] Hofmark-Aich-Straße 25 D-84030 Landshut Phone +49 871 707-0 Fax +49 871 707-465 [email protected] www.ebmpapst.com www.ebmpapst.com www.ebmpapst.com 44 Berlin Dipl.-Ing. (TH) Jens Duchow Händelstraße 7 D-16341 Panketal Phone +49 30 944149-62 Fax +49 30 944149-63 [email protected] Heilbronn / Heidelberg Dipl.-Ing. Mark Gartner Gehrweg 12 D-74199 Unterheinriet Phone +49 7130 404569-1 Fax +49 7130 404569-2 [email protected] Bielefeld Dipl.-Ing. (FH) Wolf-Jürgen Weber Niehausweg 13 D-33739 Bielefeld Phone +49 5206 91732-31 Fax +49 5206 91732-35 [email protected] Kassel Dipl.-Ing. (FH) Ralph Brück Hoherainstraße 3 b D-35075 Gladenbach Phone +49 6462 4071-10 Fax +49 6462 4071-11 [email protected] Dortmund Dipl.-Ing. (FH) Hans-Joachim Pundt Auf den Steinern 3 D-59519 Möhnesee-Völlinghausen Phone +49 2925 800-407 Fax +49 2925 800-408 [email protected] Koblenz Winfried Schaefer Hinter der Kirch 10 D-56767 Uersfeld Phone +49 2657 16-96 Fax +49 2657 16-76 [email protected] Frankfurt Dipl.-Ing. Christian Kleffmann Dr.-Hermann-Krause-Straße 23 D-63452 Hanau Phone +49 6181 1898-12 Fax +49 6181 1898-13 [email protected] Munich Dipl.-Wirt.-Ing. (FH) Jens Peter Uhlandstraße 6 D-74427 Fichtenberg Phone +49 7971 260-180 Fax +49 7971 260-221 [email protected] Halle Dipl.-Ing. (TU) Michael Hanning Lercheneck 4 D-06198 Salzatal / OT Lieskau Phone +49 345 55124-56 Fax +49 345 55124-57 [email protected] Nuremberg Dipl.-Wirt.-Ing. (FH) Axel Resch Steinsfeldstraße 80 D-74626 Bretzfeld Phone +49 7946 94401-02 Fax +49 7946 94401-03 [email protected] Hamburg Ingenieurbüro Breuell GmbH Ing. Dirk Kahl Elektroingenieur Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-19 Fax +49 40 538092-84 [email protected] Offenburg Dipl.-Ing. (FH) Ralf Braun Hubeneck 21 D-77704 Oberkirch Phone +49 7802 9822-52 Fax +49 7802 9822-53 [email protected] Stuttgart Dipl.-Ing. (FH) Rudi Weinmann Hindenburgstraße 100/1 D-73207 Plochingen Phone +49 7153 9289-80 Fax +49 7153 9289-81 [email protected] Ulm M.Sc. Reinhard Sommerreißer Am Silbermannpark 10 D-86161 Augsburg Phone +49 821 6610-7023 Fax +49 821 6610-7024 [email protected] Distributors Frankfurt R.E.D. Handelsgesellschaft mbH Gutenbergstraße 3 D-63110 Rodgau - Jügesheim Phone +49 6106 841-0 Fax +49 6106 841-111 [email protected] www.red-elektromechanik.de Hamburg Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 [email protected] Munich A. Schweiger GmbH Ohmstraße 1 D-82054 Sauerlach Phone +49 8104 897-0 Fax +49 8104 897-90 [email protected] www.schweiger-gmbh.com (1 to 5 pieces) North Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 [email protected] South HDS Ventilatoren Vertriebs GmbH Glaswiesenstraße 1 D-74677 Dörzbach Phone +49 7937 8033520 Fax +49 7937 8033525 [email protected] EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:01 Seite 45 ebm-papst in Europe Europe Austria ebm-papst Motoren & Ventilatoren GmbH Straubingstraße 17 A-4030 Linz Phone +43 732 321150-0 Fax +43 732 321150-20 [email protected] www.ebmpapst.at Belarus ebm-papst Bel AgmbH P.O. Box 117 BY-220138 Minsk Phone +375 17 3851556 Fax +375 17 3851556 [email protected] www.ebmpapst.by Belgium ebm-papst Benelux B.V. Sales office Belgium-Luxemburg Romeinsestraat 6/0101 Research Park Haasrode B-3001 Heverlee-Leuven Phone +32 16 396-200 Fax +32 16 396-220 [email protected] www.ebmpapst.be Bulgaria ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 RO-500327 Brasov Phone +40 268 312-805 Fax +40 268 312-805 [email protected] Croatia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] Czech Republic / Slovakia ebm-papst CZ s.r.o. Kaštanová 34a CZ-620 00 Brno Phone +420 544 502-411 Fax +420 547 232-622 [email protected] www.ebmpapst.cz Denmark ebm-papst Denmark ApS Vallensbækvej 21 DK-2605 Brøndby Phone +45 43 631111 Fax +45 43 630505 [email protected] www.ebmpapst.dk Estonia ebm-papst Oy, Eesti Filiaal Kesk tee 13 Aaviku küla, Jüri Tehnopark EST-75301 Rae Vald, Harjumaa Phone +372 65569-78 Fax +372 65569-79 www.ebmpapst.ee Finland ebm-papst Oy Puistotie 1 FIN-02760 Espoo Phone +358 9 887022-0 Fax +358 9 887022-13 [email protected] www.ebmpapst.fi France ebm-papst sarl ZI Nord - rue A. Mohler BP 62 F-67212 Obernai Cedex Phone +33 820 326266 Fax +33 3 88673883 [email protected] www.ebmpapst.fr Greece Helcoma Th. Rotas & Co OE Davaki 65 GR-17672 Kallithea-Attiki Phone +30 210 9513-705 Fax +30 210 9513-490 [email protected] www.helcoma.gr Hungary ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] Iceland RJ Engineers Stangarhyl 1a IS-110 Reykjavik Phone +354 567 8030 Fax +354 567 8015 [email protected] www.rj.is Ireland ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 [email protected] www.ebmpapst.co.uk AuBren Limited Portlaoise Business & Technology Park Mountrath Road IRL-Portlaoise, Co. Laois Phone +353 57 8664343 Fax +353 57 8664346 [email protected] www.aubren.com Italy ebm-papst Srl Via Cornaggia 108 I-22076 Mozzate (Co) Phone +39 0331 836201 Fax +39 0331 821510 [email protected] www.ebmpapst.it Macedonia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] 45 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage fan agent compact fan agent 16.05.2011 10:01 Seite 46 ebm-papst in Europe motor specialist motor agent Netherlands ebm-papst Benelux B.V. Engelseweg 127 NL-5705 AC Helmond Phone +31 492 502-900 Fax +31 492 502-950 [email protected] www.ebmpapst.nl Russia ebm-papst Ural GmbH Posadskaja-Strasse, 23(E), 3 RU-620102 Ekaterinburg Phone +7 343 2338000 Fax +7 343 2337788 [email protected] www.ebmpapst.ur.ru Switzerland ebm-papst AG Rütisbergstrasse 1 CH-8156 Oberhasli Phone +41 44 73220-70 Fax +41 44 73220-77 [email protected] www.ebmpapst.ch Norway ebm-papst AS P.B. 173 Holmlia N-1203 Oslo Phone +47 22 763340 Fax +47 22 619173 [email protected] www.ebmpapst.no ebm-papst Rus GmbH proezd 4529, vladenie 5, stroenie 1 RU-141000 Mytistschi, Oblast Moskau Phone +7 495 9807524 Fax +7 495 5140924 [email protected] www.ebmpapst.ru Turkey Akantel Elektronik San. Tic. LTD. Sti. Atatürk Organize Sanayi Bölgesi 10007 SK. No.:6 TR-35620 Cigli-Izmir Phone +90 232 3282090 Fax +90 232 3280270 [email protected] www.ebmpapst.com.tr Poland ebm-papst Polska Sp. z o.o. ul. Annopol 4A PL-03236 Warszawa Phone +48 22 6757819 Fax +48 22 6769587 [email protected] www.ebmpapst.pl Portugal ebm-papst (Portugal), Lda. Centro Empresarial de Alverca Rua de Adarse, Vale D’Ervas Corpo D / Fracção 3 P-2615-178 Alverca do Ribatejo Phone +351 218 394 880 Fax +351 218 394 759 [email protected] www.ebmpapst.pt Romania ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 RO-500327 Brasov Phone +40 268 312-805 Fax +40 268 312-805 [email protected] 46 Serbia & Montenegro ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] Spain ebm-papst Ibérica S.L. Avda. del Sistema Solar, 29 E-28830 San Fernando de Henares (Madrid) Phone +34 91 6780894 Fax +34 91 6781530 [email protected] Sweden ebm-papst AB Äggelundavägen 2 S-17562 Järfälla Phone +46 8 7619400 Fax +46 8 362306 [email protected] www.ebmpapst.se Ukraine ebm-papst Ukraine LLC Lepse Boulevard, 4, Building 47 UA-03067 Kiev Phone +38 044 2063091 Fax +38 044 2063091 [email protected] www.ebmpapst.ua United Kingdom ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 [email protected] www.ebmpapst.co.uk ebm-papst Automotive & Drives (UK) Ltd. The Smithy Fidlers Lane GB-East Ilsley, Berkshire RG20 7LG Phone +44 1635 2811-11 Fax +44 1635 2811-61 A&[email protected] www.ebmpapst-ad.com EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:01 Seite 47 ebm-papst in America and Africa America Argentina ebm-papst de Argentina S.A. Hernandarias 148 Lomas del Mirador Pcia. de Buenos Aires (1752) Phone +54 11 46576135 Fax +54 11 46572092 [email protected] www.ebmpapst.com.ar Brasil ebm-papst Motores Ventiladores Ltda. Av. José Giorgi, 301 Galpões B6+B7 Condominio Logical Center BR-06707-100 Cotia - São Paulo Phone +55 11 4613-8700 Fax +55 11 3164-8924 [email protected] www.ebmpapst.com.br USA ebm-papst Inc. P.O. Box 4009 100 Hyde Road USA-Farmington, CT 06034 Phone +1 860 674-1515 Fax +1 860 674-8536 [email protected] www.ebmpapst.us ebm-papst Automotive & Drives, Inc. 3200 Greenfield, Suite 255 USA-Dearborn, MI 48120 Phone +1 313 406-8080 Fax +1 313 406-8081 [email protected] www.ebmpapst-automotive.us Africa South Africa ebm-papst South Africa (Pty) Ltd. P.O. Box 3124 1119 Yacht Avenue ZA-2040 Honeydew Phone +27 11 794-3434 Fax +27 11 794-5020 [email protected] www.ebmpapst.co.za Canada ebm-papst Canada Inc. 1800 Ironstone Manor, Unit 2 CDN-Pickering, Ontario, L1W3J9 Phone +1 905 420-3533 Fax +1 905 420-3772 [email protected] www.ebmpapst.ca Mexico ebm Industrial S.de R.L. de C.V. Paseo de Tamarindos 400-A-5to Piso Col. Bosques de las Lomas MEX-Mexico 05120, D.F. Phone +52 55 3300-5144 Fax +52 55 3300-5243 [email protected] www.ebmpapst.com.mx 47 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage fan agent compact fan agent 16.05.2011 10:01 Seite 48 ebm-papst in Asia and Australia motor specialist motor agent Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Huajing Road WaiGaoQiao Free Trade Zone No. 2001, Yang Gao (N) Road VRC-200131 Shanghai, P.R. of China Phone +86 21 5046-0183 Fax +86 21 5046-1119 [email protected] www.ebmpapst.com.cn Hong Kong ebm-papst Hong Kong Ltd. Unit No. 13,9 / F Technology Park, 18 On Lai Street Siu Lek Yuen, Shatin N.T. Hong Kong - P.R. of China Phone +852 2145-8678 Fax +852 2145-7678 [email protected] India ebm-papst India Pvt. Ltd. 26/3, G.N.T. Road, Erukkencherry IND-Chennai-600118 Phone +91 44 25372556 Fax +91 44 25371149 [email protected] www.ebmpapst.in Indonesia ebm-papst Indonesia Representative Office German Centre, 4th Floor, Suite 4470 Jl. Kapt. Subijono Dj. Bumi Serpong Damai RI-15321 Tangerang Phone +62 21 5376250 Fax +62 21 5388305 [email protected] Israel Polak Bros. Import Agencies Ltd. 9 Hamefalsim Street IL-Kiryat Arie, Petach-Tikva 49514 Phone +972 3 9100300 Fax +972 3 5796679 [email protected] www.polak.co.il 48 Japan ebm-papst Industries Japan K.K. 12 Floor, Benex S-3 Bldg. 3-20-8 Shinyokohama, Kohoku-ku J-222-0033 Yokohama Phone +81 45 47057-51 Fax +81 45 47057-52 [email protected] www.ebmpapst.jp Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. B 6-2, Digital Media City (DMC) Sangam-Dong, Mapo-Gu ROK-Seoul 121-270 Phone +82 2 366213-24 Fax +82 2 366213-26 [email protected] www.ebmpapst.co.kr Malaysia ebm-papst Malaysia Representative Office Unit 12-2, Jalan USJ Sentral 3 Persiaran Subang, Selangor Darul Ehsan MAL-47600 Subang Jaya Phone +60 3 8024-1680 Fax +60 3 8024-8718 [email protected] Singapore ebm-papst SEA Pte. Ltd. No. 23 Ubi Road 4 #06-00 Olympia Industrial Building SGP-Singapore 408620 Phone +65 65513789 Fax +65 68428439 [email protected] Taiwan ETECO Engineering & Trading Corp. 10F-I, No. 92, Teh-Wei Str. RC-Tsow-Inn District, Kaohsiung Phone +886 7 557-4268 Fax +886 7 557-2788 [email protected] www.ebmpapst.com.tw Thailand ebm-papst Thailand Co., Ltd. 99/349 Na-Nakorn Bldg., 4th Floor Chaeng Wattana Road, Thungsonghong, THA-10210 Laksi, BKK Phone +66 2 57615-24 Fax +66 2 57615-42 [email protected] United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 UAE-Dubai Phone +971 4 88608-26 Fax +971 4 88608-27 [email protected] www.ebmpapst.ae Vietnam ebm-papst Vietnam Representative Office Room #102, 25 Nguyen Van Thu Street District 1 VN-Ho Chi Minh City Phone +84 8 39104099 Fax +84 8 39103970 [email protected] EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:01 Seite 49 Australia Australia ebm-papst A&NZ Pty Ltd. 10 Oxford Road AUS-Laverton North, Victoria, 3026 Phone +61 3 9360-6400 Fax +61 3 9360-6464 [email protected] www.ebmpapst.com.au New Zealand ebm-papst A&NZ Pty Ltd. 102 Henderson Valley Road NZ-Henderson, Auckland 1230 Phone +64 9 837-1884 Fax +64 9 837-1899 [email protected] www.ebmpapst.com.au 49 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage Notes 50 16.05.2011 10:01 Seite 50 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:01 Seite 51 51 EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage 16.05.2011 10:01 Seite 52 37845-7-8811 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 [email protected] www.ebmpapst.com