EC axial fans - HyBlade®, US-edition - ebm

EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:55
Seite 1
EC axial fans - HyBlade®
US-edition
The engineer’s choice
version 05/2011
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:55
Seite 2
The new EC axial fans - HyBlade®
A new and unique hybrid blade design makes ebm-papst axial fans even quieter, more powerful and
lasting longer. The novel HyBlade® fan blades use a support structure made of highly robust,
corrosion-proof aluminium alloy and a coating made of special reinforced fibre plastics. Their aerodynamically optimal form results in enormous acoustic benefits at even higher efficiencies
compared to conventional blades. And this, in turn, offers further benefits when used in refrigeration, heating and ventilation.
A revolutionary development
In refrigeration and ventilation, axial fans are frequently used, for
instance to cool heat exchangers with air passing through them. For
compact systems, the best tried and tested choice is the ebm-papst
external-rotor motor with the axial fan blades mounted onto its rotor.
Apart from compact dimensions, the fans in such applications are
expected to yield high air performance at minimal noise.
So far, fan blades are conventionally made of sheet steel or aluminium.
In order to meet exacting requirement for optimum efficiency and
acoustic behaviour, ebm-papst focused intensely on developing new
blade geometries. However, the limited design possibilities of a monolithic sheet metal blade with uniform sheet thickness are obstacles
engineers have to simply accept.
To manage the required quantum leap and arrive at lower noise and
better efficiency, new construction principles and materials, or component structures, to be more precise, are needed. This is the approach
ebm-papst took with its revolutionary hybrid blade concept, using hybrid components and structures to join seemingly irreconcilable characteristic in one harmonious functional unit.
The modular system consisting of motor, electronics and impeller allows for optimum configuration, making the new line of EC HyBlade® axial fans
unbeatable as to combinatorics and power range. The integrated motor electronics are based on state-of-the-art EC technology and correspond to the
“2nd generation”. This makes them highly efficient and they already comply with the latest standards of the defined European Efficiency Classes.
2
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:56
Seite 3
Table of contents
New EC axial fans - HyBlade®
2
GreenTech: The Green Company
4
Size 500
6
Size 560
10
Size 630
14
Size 710
20
Size 800
24
Size 910
28
Size 990
32
Electrical connections
35
Technical parameters & scope
40
ebm-papst representatives & subsidiaries
44
3
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:56
Seite 4
Sustainability is at the Centre of Our
Thoughts and Actions. Out of Conviction!
Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked
according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better
than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:56
Seite 5
GreenTech is pro-active development.
GreenTech is acknowledged and certified.
Even in the design phase, the materials and processes we use are optimi-
Every step in our chain of production meets the stringent standards of
sed for the greatest possible eco-friendliness, energy balance and –
environmental specialists and the public. The 2008 Environmental Prize
wherever possible – recyclability. We continually improve the material
of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency
and performance of our products, as well as the flow and noise charac-
Award 2009 of the dena – to give just a few examples – testify to this.
teristics. At the same time, we significantly reduce energy consumption.
The environmental advantage gained in the performance of the products
Close cooperation with universities and scientific institutes and the pro-
developed from our GreenTech philosophy can also be measured in the
fessorship we endow in the area of power engineering and regenerative
fulfilment of the most stringent energy and environmental standards.
energies allows us to profit from the latest research findings in these
In many instances, our products are already well below the thresholds
fields – and at the same time ensure highly qualified young academics.
energy legislation will impose a few years from now – several times over.
GreenTech is ecofriendly production.
Our customers profit from this every day.
GreenTech also stands for maximum energy efficiency in our production
The heart of GreenTech is ebm-papst EC technology. The EC technology
processes. There, the intelligent use of industrial waste heat and ground-
at the core of our most efficient motors and fans allows efficiency of up
water cooling, photovoltaics and, of course, our own cooling and venti -
to 90%, saves energy at a very high level, significantly extends service
lation technology are of the utmost importance. Our most modern plant,
life and makes our products maintenance-free. These values pay off not
for instance, consumes 91% less energy than currently specified and
only for the environment, but every cent also pays off for the user! All
required. In this way, our products contribute to protecting the environ-
ebm-papst products – even those for which EC technology does not (yet)
ment, from their origin to their recyclable packaging.
make sense from an application viewpoint – feature the greatest possible connection of economy and ecology.
5
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:56
Seite 6
EC axial fans - HyBlade®
Ø 500
Frequency
Speed/rpm (1)
Max.
power input (1)
Max.
current draw (1)
Max. operative range
Perm. amb. temp.
Mass without
attachments
VAC
Hz
rpm
kW
A
Pa
°C
kg
Type
Motor
*3G 500
M3G 084-GF
0°
A
1~ 100-130
*3G 500
M3G 112-EA
0°
B
*3G 500
M3G 112-GA
0°
C
*3G 500
M3G 112-GA
0°
D
subject to alterations
50/60
1080
0,38
3,30
105
-25..+60
6,2
p. 36 / K1)
1~ 200-277
50/60
1420
0,75
3,40
175
-25..+60
7,2
p. 37 / L3)
3~ 200-240
50/60
1600
0,98
3,20
200
-25..+60
9,2
p. 35 / L2)
3~ 380-480
50/60
1600
0,98
1,60
200
-25..+60
9,2
p. 39 / K3)
(1) Nominal data in operating point with maximum load and 115 VAC or 230 VAC or 400 VAC
[Pa]
0,80 [in H2O]
Curves
200
C
Air performance measured
D
as per: ISO 5801,
4
in ebm-papst full nozzle
0,70
and without protection against
4
accidental contact
0,60
100
1
1080
0,26
2,26
72
2
1080
0,30
2,61
68
A
3
1080
0,33
2,87
65
A
4
1080
0,38
3,30
66
B
1
1420
0,55
2,51
78
B
2
1420
0,62
2,80
75
LwA as per ISO 13347,
B
3
1420
0,68
3,03
73
LpA measured at 1 m distance
B
4
1420
0,75
3,40
74
C
1
1600
0,73
2,32
80
C
2
1600
0,83
2,66
77
C
3
1600
0,91
2,82
75
C
4
1600
0,98
3,20
76
D
1
1600
0,73
1,16
80
D
2
1600
0,83
1,33
77
D
3
1600
0,91
1,41
75
D
4
1600
0,98
1,60
76
0,50
A
The acoustic values given are
3
4
only valid under the measur-
0,30
may vary depending on the
installation situation.
2
3
60
With any deviation to the stan-
0,20
2
dard setup, the specific values
40
have to be checked and re-
2
viewed once installed or fitted!
0,10
20
For detailed information
0
1000
2000
6
LwA
[dB(A)]
A
ment conditions listed and
80
I
[A]
to fan axis
0,40
120
3
P1
[kW]
Suction-side noise levels:
160
140
n
[rpm]
A
Installation category A,
B
180
Technical features and
electr. connections
Nominal
voltage range
Nominal data
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Pressed-on round sheet steel plate, extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, B C D coated in black additionally
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "B" ("F" applying to the main components as per EN)
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
2000
1
4000
3000
4000
6000
1
5000
8000
1
6000 [CFM]
10000 [m /h]
3
see page 40 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:56
Seite 7
Direction of air flow
– Technical features: See electrical connections p. 36 ff.
– EMC: A B Interference emission acc. to EN 61000-6-3
C D Interference emission acc. to EN 61000-6-4
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A B D Variable
– Terminal box: C Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: GOST; UL/CSA are applied for; CCC on request
❮ "V"
Without
attachments
❮ "V"
With full
square nozzle
❮ "V"
With guard grille
for short nozzle
"V"
on request
W3G 500-GD09 -41
on request
"V"
A3G 500-AM56 -21
W3G 500-GM56 -21
S3G 500-AM56 -21
"V"
on request
W3G 500-GN38 -13
on request
"V"
A3G 500-AN33 -01
W3G 500-GN33 -01
S3G 500-AN33 -01
Direction of air flow "A" on request
7
Drawings
p. 8 ff.
Electr. connections
p. 35 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:56
Seite 8
EC axial fans - HyBlade®
Ø 500 with motor M3G084, drawings for direction of air flow "V"
Type
Without attachments
A
111±2
104.7±3
4xM6
on request
Mass
[kg]
6,2
Depth of screw
8-10 mm
Internal diameter of the
wall ring at least 503 mm
8
85
600+2
0
4x90˚
Ø497±1
Ø178
Ø150±0.25
Ø100
45˚
47.7
160±2
Core-end sleeve
Ø164±0.35
❮ "V"
With full square nozzle
A
Type
Mass
[kg]
W3G 500-GD09 -41
12,2
Type
Mass
[kg]
Ø11
Ø529
156.5±5
16
615±1
656-3
120
❮ "V"
With guard grille for short nozzle
A
on request
8,7
Ø565
Ø521.4
64±4
Internal diameter of the
wall ring at least 503 mm
Ø9
5
96
❮ "V"
8
71,4±3
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:56
Seite 9
EC axial fans - HyBlade®
Ø 500 with motor M3G112, drawings for direction of air flow "V"
Type
Without attachments
B
C
116±3
112±2
D
5x
A3G 500-AM56 -21
on request
A3G 500-AN33 -01
Mass
[kg]
g
7,2
160,5
9,2
180,5
9,2
180,5
˚
Ø497±2
Ø200±1
Ø165±0.5
72
8
85
800+2
0
Internal diameter of the
wall ring at least 503 mm
5xM6
56.5±0.6
g±2
Core-end sleeve
Ø186±0.5
Depth of screw
12-16 mm
❮ "V"
With full square nozzle
B
171±5
C
D
Type
Mass
[kg]
W3G 500-GM56 -21
W3G 500-GN38 -13
W3G 500-GN33 -01
17,2
Type
Mass
[kg]
t
S3G 500-AM56 -21
on request
S3G 500-AN33 -01
10,5
52,0
12,5
72,0
12,5
72,0
19,2
19,2
Ø528
C
Ø11
Cable gland
16
615±1
656-3
120
❮ "V"
With guard grille for short nozzle
B
C
64±4
Ø565
Ø521
D
Internal diameter of the
wall ring at least 503 mm
108.5±3
7
t±3
Ø9
❮ "V"
9
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:57
Seite 10
EC axial fans - HyBlade®
Ø 560
Frequency
Speed/rpm (1)
Max.
power input (1)
Max.
current draw (1)
Max. operative range
Perm. amb. temp.
Mass without
attachments
VAC
Hz
rpm
kW
A
Pa
°C
kg
Type
Motor
*3G 560
M3G 112-EA
-5°
A
1~ 200-277
*3G 560
M3G 112-GA
-5°
B
*3G 560
M3G 112-GA
-5°
C
subject to alterations
50/60
1000
0,40
1,80
100
-25..+60
9,3
p. 36 / K1)
3~ 200-240
50/60
1350
0,95
3,00
180
-25..+60
9,3
p. 35 / L2)
3~ 380-480
50/60
1350
0,95
1,50
180
-25..+60
9,3
p. 39 / K3)
(1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC
[in H2O]
Air performance measured
B C
as per: ISO 5801,
in ebm-papst full nozzle
and without protection against
160
accidental contact
3
0,40
0,29
1,29
67
1000
0,34
1,48
66
A
3
1000
0,37
1,61
66
A
4
1000
0,40
1,80
68
1350
0,67
2,22
75
2
1350
0,78
2,50
74
LwA as per ISO 13347,
B
3
1350
0,86
2,74
73
LpA measured at 1 m distance
B
4
1350
0,95
3,00
77
C
1
1350
0,67
1,11
75
C
2
1350
0,78
1,25
74
C
3
1350
0,86
1,37
73
C
4
1350
0,95
1,50
77
0,30
ment conditions listed and
may vary depending on the
installation situation.
0,20
2
With any deviation to the standard setup, the specific values
40
have to be checked and re-
2
0,10
viewed once installed or fitted!
For detailed information
0
1000
2000
10
1000
2
1
The acoustic values given are
3
20
1
A
to fan axis
4
60
2000
4000
3000
4000
6000
1
5000
8000
LwA
[dB(A)]
B
only valid under the measur-
80
I
[A]
B
A
100
P1
[kW]
Suction-side noise levels:
0,60
120
0,50
140
n
[rpm]
A
Installation category A,
4
0,70
[Pa]
Curves
180
Technical features and
electr. connections
Nominal
voltage range
Nominal data
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "B" ("F" applying to the main components as per EN)
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
6000
1
[CFM]
10000
[m3/h]
see page 40 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:57
Seite 11
Direction of air flow
– Technical features: See electrical connections p. 36 ff.
– EMC: B C Interference emission acc. to EN 61000-6-3
A Interference emission acc. to EN 61000-6-4
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A C Variable
– Terminal box: B Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: GOST; UL/CSA are applied for; CCC on request
❮ "V"
Without
attachments
❮ "V"
With full
square nozzle
❮ "V"
With guard grille
for short nozzle
S3G 560-AP68 -21
A3G 560-AP68 -21
W3G 560-GP68 -21
"V"
on request
W3G 560-GQ49 -13
on request
"V"
A3G 560-AQ41 -01
W3G 560-GQ41 -01
S3G 560-AQ41 -01
"V"
Direction of air flow "A" on request
11
Drawings
p. 12
Electr. connections
p. 35 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:57
Seite 12
EC axial fans - HyBlade®
Ø 560 with motor M3G112, drawings for direction of air flow "V"
Type
Without attachments
A
B
134±3
115±2
C
5x
A3G 560-AP68 -21
on request
A3G 560-AQ41 -01
Mass
[kg]
g
7,2
180,5
9,3
200,5
9,3
200,5
˚
Internal diameter of the
wall ring at least 559 mm
8
85
800+
20
Ø553±2
Ø200±1
Ø165±0.5
72
56.5±0.6
5xM6
g±2
Core-end sleeve
Ø186 ±0.5
❮ "V"
Depth of screw
12-16 mm
With full square nozzle
A
182.5±5
B
C
Type
Mass
[kg]
W3G 560-GP68 -21
W3G 560-GQ49 -13
W3G 560-GQ41 -01
18,9
Type
Mass
[kg]
t
S3G 560-AP68 -21
on request
S3G 560-AQ41 -01
11,8
64
13,9
84
13,9
84
21,0
21,0
Ø625
B
16
Ø11
Cable gland
675±1
725-3
125
❮ "V"
With guard grille for short nozzle
A
74±4
B
7
116
Ø9
t±3
❮ "V"
12
Internal diameter of the
wall ring at least 559 mm
Ø700
Ø645
C
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:57
Seite 13
13
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:57
Seite 14
EC axial fans - HyBlade®
Ø 630
kW
A
800
0,28
2,40
Technical features and
electr. connections
rpm
Mass without
attachments
Hz
Perm. amb. temp.
*3G 630
VAC
Max. operative range
*3G 630
Max.
current draw (1)
M3G 084-GF
Max.
power input (1)
*3G 630
Speed/rpm (1)
Motor
Frequency
Type
Nominal
voltage range
Nominal data
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades (5): A B C D E Pressed-on round sheet steel plate; F G Insertion part
made of sheet aluminium; Both versions extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, C D E F G coated in black additionally
– Direction of rotation: A B C D E counter-clockwise, F G clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: A B C D E "B" ("F" applying to the main components as per EN), F G "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Pa
°C
kg
75
-25..+60
6,3
p. 36 / K1)
0°
A
1~ 100-130
50/60
M3G 084-GF
0°
B
1~ 200-277
50/60
800
0,28
1,20
75
-25..+60
6,3
p. 36 / K1)
M3G 112-GA
-5°
C
1~ 200-277
50/60
1000
0,72
3,20
140
-25..+60
9,3
p. 37 / L3)
*3G 630
M3G 112-IA
-5°
D
3~ 200-240
50/60
1140
0,97
3,20
170
-25..+60
11,3
p. 35 / L2)
*3G 630
M3G 112-IA
-5°
E
3~ 380-480
50/60
1140
0,97
1,60
170
-25..+60
11,3
p. 39 / K3)
*3G 630
M3G 150-IF
0°
F
3~ 200-240
50/60
1450
2,95
8,90
270
-25..+60
24,4
p. 38 / L5)
*3G 630
M3G 150-IF
0°
G
3~ 380-480
50/60
1510
3,20
5,00
290
-25..+65
24,4
p. 38 / L5)
subject to alterations
(1) Nominal data in operating point with maximum load and 115 VAC or 230 VAC or 400 VAC
[Pa]
[in H2O]
Curves
4
F
800
0,18
1,64
65
2
800
0,23
2,04
63
A
3
800
0,27
2,34
63
A
4
800
0,28
2,40
66
B
1
800
0,18
0,82
65
B
2
800
0,23
1,02
63
LwA as per ISO 13347,
B
3
800
0,27
1,17
63
LpA measured at 1 m distance
B
4
800
0,28
1,20
66
C
1
1000
0,46
2,11
71
C
2
1000
0,55
2,51
68
C
3
1000
0,64
2,88
68
C
4
1000
0,72
3,20
71
D
1
1140
0,64
2,04
74
D
2
1140
0,78
2,50
71
D
3
1140
0,89
2,84
72
D
4
1140
0,97
3,20
74
in ebm-papst full nozzle
1,00
and without protection against
240
accidental contact
0,80
Suction-side noise levels:
200
D
3
E
to fan axis
3
4
160
The acoustic values given are
0,60
C
only valid under the measur4
ment conditions listed and
120
may vary depending on the
3
0,40
installation situation.
2
3
B
2
A
80
With any deviation to the stan4
dard setup, the specific values
0,20
2
40
3
have to be checked and re-
2
viewed once installed or fitted!
2
For detailed information
1
0
2000
4000
14
4000
1
6000
8000
12000
1
8000
10000
16000
LwA
[dB(A)]
1
Installation category A,
4
I
[A]
A
as per: ISO 5801,
280
P1
[kW]
A
Air performance measured
G
n
[rpm]
1 1
12000 [CFM]
20000 [m /h]
3
see page 40 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:57
Seite 15
Direction of air flow
– Technical features: See electrical connections p. 36 ff.
– EMC: A B D E F G Interference emission acc. to EN 61000-6-3
C Interference emission acc. to EN 61000-6-4
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A B C E Variable
– Terminal box: D F G Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A B C D E GOST; UL/CSA are applied for; CCC on request
F G GOST, UL/CSA; CCC on request
❮ "V"
Without
attachments
❮ "V"
With full
square nozzle
❮ "V"
With guard grille
for short nozzle
"V"
on request
W3G 630-GD10 -41
on request
"V"
A3G 630-AD03 -A1
W3G 630-GD03 -A1
S3G 630-AD03 -A1
"V"
A3G 630-AQ37 -21
W3G 630-GQ37 -21
S3G 630-AQ37 -21
"V"
on request
W3G 630-GR92 -13
on request
"V"
A3G 630-AR85 -01
W3G 630-GR85 -01
S3G 630-AR85 -01
"V"
on request
W3G 630-GU29 -11
on request
"V"
A3G 630-AU23 -01
W3G 630-GU23 -01
S3G 630-AU23 -01
Direction of air flow "A" on request
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
E
1
1140
0,64
1,02
74
E
2
1140
0,78
1,25
71
E
3
1140
0,89
1,42
72
E
4
1140
0,97
1,60
74
F
1
1450
2,24
6,80
81
F
2
1450
2,45
7,50
80
F
3
1450
2,67
8,20
80
F
4
1450
2,95
8,90
84
G
1
1510
2,49
3,77
81
G
2
1510
2,74
4,18
81
G
3
1510
2,94
4,47
81
G
4
1510
3,20
5,00
85
15
Drawings
p. 16 ff.
Electr. connections
p. 35 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:57
Seite 16
EC axial fans - HyBlade®
Ø 630 with motor M3G084, drawings for direction of air flow "V"
Type
Without attachments
A
112.3±2
93±3
4xM6
B
4x90˚
Ø626±1
Ø178
Ø150±0.25
Ø100
45˚
Depth of screw
8-10 mm
on request
A3G 630-AD03 -A1
Mass
[kg]
6,3
6,3
8
85
600+20
Internal diameter of the
wall ring at least 634 mm
(47.7)
Ø164±0.35
160 ±2
Core-end sleeve
❮ "V"
With full square nozzle
A
215±5
Mass
[kg]
W3G 630-GD10 -41
W3G 630-GD03 -A1
20,4
Type
Mass
[kg]
on request
S3G 630-AD03 -A1
10,6
20,4
Ø11
Ø726
B
Type
20
750±1
805-3
142
❮ "V"
With guard grille for short nozzle
A
❮ "V"
16
21,4±3
10,6
Internal diameter of the
wall ring at least 634 mm
Ø9
5
146
B
Ø750
Ø701.4
20.7±4
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:57
Seite 17
EC axial fans - HyBlade®
Ø 630 with motor M3G112, drawings for direction of air flow "V"
Type
Without attachments
C
D
144±3
123±2
E
5x
A3G 630-AQ37 -21
on request
A3G 630-AR85 -01
Mass
[kg]
g
9,3
180,5
11,3 200,5
11,3 200,5
˚
Ø627±2
Ø200±1
Ø165±0.5
72
8
85
800+
20
Internal diameter of the
wall ring at least 634 mm
56.5±0.6
5xM6
g±2
Core-end sleeve
Ø186±0.5
Depth of screw
12-16 mm
❮ "V"
With full square nozzle
C
209±5
D
E
Type
Mass
[kg]
W3G 630-GQ37 -21
W3G 630-GR92 -13
W3G 630-GR85 -01
24,3
Type
Mass
[kg]
t
S3G 630-AQ37 -21
on request
S3G 630-AR85 -01
14,6
39,5
16,6
59,5
16,6
59,5
26,3
26,3
Ø726
D
Ø11
Cable gland
750±1
805-3
20
142
❮ "V"
With guard grille for short nozzle
C
D
60±4
7
141±3
Ø750
Ø701
E
Internal diameter of the
wall ring at least 634 mm
Ø9
t±3
❮ "V"
17
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:58
Seite 18
EC axial fans - HyBlade®
Ø 630 with motor M3G150, drawings for direction of air flow "V"
Without attachments
F
184±3
145±2
14xM10
Depth of screw
max. 25 mm
G
Type
Mass
[kg]
on request
A3G 630-AU23 -01
24,4
24,4
8x
˚
45
Ø 627±2
22.5˚
6x6
0˚
Internal diameter of the
wall ring at least 634 mm
70
Ø232-2
Ø252±0.3
Ø275
250,5±1
Cable gland
❮ "V"
With full square nozzle
F
250±5
Mass
[kg]
W3G 630-GU29 -11
W3G 630-GU23 -01
39,5
Type
Mass
[kg]
on request
S3G 630-AU23 -01
31,5
39,5
Ø11
Ø696
G
Type
20
750±1
805-3
150
❮ "V"
With guard grille for short nozzle
F
76±4
72,5±3
❮ "V"
18
31,5
Internal diameter of the
wall ring at least 634 mm
Ø10
4
178±3
Ø750
Ø717.2
G
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:58
Seite 19
19
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:58
Seite 20
EC axial fans - HyBlade®
Ø 710
Nominal
voltage range
Frequency
Speed/rpm (1)
Max.
power input (1)
Max.
current draw (1)
Max. operative range
Perm. amb. temp.
Mass without
attachments
VAC
Hz
rpm
kW
A
Pa
°C
kg
1~ 200-277
50/60
830
0,70
3,10
100
-25..+60
12,0
p. 37 / L3)
B
3~ 200-240
50/60
900
0,93
3,00
125
-25..+60
12,0
p. 35 / L2)
C
3~ 380-480
50/60
900
0,93
1,50
125
-25..+60
12,0
p. 39 / K3)
0°
D
3~ 200-240
50/60
1230
2,65
8,10
240
-25..+60
25,3
p. 38 / L5)
0°
E
3~ 380-480
50/60
1250
2,83
4,30
240
-25..+60
25,3
p. 38 / L5)
Curve
Blade angle
Nominal data
Type
Motor
*3G 710
M3G 112-IA
0°
A
*3G 710
M3G 112-IA
0°
*3G 710
M3G 112-IA
0°
*3G 710
M3G 150-IF
*3G 710
M3G 150-IF
subject to alterations
(1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC
[Pa]
Air performance measured
E
D
as per: ISO 5801,
4 4
in ebm-papst full nozzle
and without protection against
180
0,80
accidental contact
3 3
0,70
200
0,60
160
0,50
4
830
0,45
2,08
69
2
830
0,55
2,49
67
A
3
830
0,64
2,86
68
A
4
830
0,70
3,10
73
1
900
0,59
1,92
70
B
2
900
0,70
2,28
69
LwA as per ISO 13347,
B
3
900
0,81
2,60
70
LpA measured at 1 m distance
B
4
900
0,93
3,00
76
C
1
900
0,59
0,96
70
C
2
900
0,70
1,12
69
C
3
900
0,81
1,30
70
C
4
900
0,93
1,50
76
D
1
1230
2,05
6,40
79
D
2
1230
2,33
7,20
78
D
3
1230
2,56
7,80
79
D
4
1230
2,65
8,10
83
E
1
1250
2,23
3,40
79
For detailed information
E
2
1250
2,44
3,71
79
see page 40 ff.
E
3
1250
2,67
4,06
79
E
4
1250
2,83
4,30
83
only valid under the measur-
0,40
ment conditions listed and
4
may vary depending on the
22
installation situation.
3
3
With any deviation to the stan-
0,20
dard setup, the specific values
have to be checked and re-
2
40
2
0,10
viewed once installed or fitted!
1
0
2000
4000
20
1
B
The acoustic values given are
60
20
LwA
[dB(A)]
Suction-side noise levels:
C
0,30
80
I
[A]
A
B
A
100
P1
[kW]
to fan axis
140
120
n
[rpm]
A
Installation category A,
0,90
220
[in H2O]
Curves
240
Technical features and
electr. connections
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: A B C counter-clockwise, D E clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: A B C "B" ("F" applying to the main components as per EN), D E "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
4000
8000
6000
8000
12000
1
10000
16000
12000
20000
11
14000 [CFM]
24000 [m /h]
3
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:58
Seite 21
Direction of air flow
– Technical features: See electrical connections p. 37 ff.
– EMC: B C D E Interference emission acc. to EN 61000-6-3
A Interference emission acc. to EN 61000-6-4
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A C Variable
– Terminal box: B D E Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A B C GOST; UL/CSA are applied for; CCC on request
D E GOST, UL/CSA; CCC on request
❮ "V"
Without
attachments
❮ "V"
With full
square nozzle
❮ "V"
With guard grille
for short nozzle
S3G 710-AO85 -21
A3G 710-AO85 -21
W3G 710-GO85 -21
"V"
on request
W3G 710-GO87 -13
on request
"V"
A3G 710-AO81 -01
W3G 710-GO81 -01
S3G 710-AO81 -01
"V"
on request
W3G 710-GU30 -11
on request
"V"
A3G 710-AU21 -01
W3G 710-GU21 -01
S3G 710-AU21 -01
"V"
Direction of air flow "A" on request
21
Drawings
p. 22 ff.
Electr. connections
p. 35 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:58
Seite 22
EC axial fans - HyBlade®
Ø 710 with motor M3G112, drawings for direction of air flow "V"
Without attachments
A
B
153±3
135±2
C
5x
Type
Mass
[kg]
A3G 710-AO85 -21
on request
A3G 710-AO81 -01
12,0
12,0
12,0
Ø703±2
Ø200±1
Ø165±0.5
72
˚
8
85
800+20
Internal diameter of the
wall ring at least 710 mm
56.5 ±0.6
5xM6
Ø186±0.5
200,5 ±2
Core-end sleeve
❮ "V"
Depth of screw
12-16 mm
With full square nozzle
A
219,5±5
B
C
Type
Mass
[kg]
W3G 710-GO85 -21
W3G 710-GO87 -13
W3G 710-GO81 -01
26,9
Type
Mass
[kg]
S3G 710-AO85 -21
on request
S3G 710-AO81 -01
18,8
26,9
26,9
Ø792
B
Ø11
Cable gland
20
810±1
850-3
160
❮ "V"
With guard grille for short nozzle
A
41±4
B
7
169±3
❮ "V"
22
Ø9
31,5±3
18,8
18,8
Internal diameter of the
wall ring at least 710 mm
Ø853
Ø799
C
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:58
Seite 23
EC axial fans - HyBlade®
Ø 710 with motor M3G150, drawings for direction of air flow "V"
Without attachments
D
Depth of screw
max. 25 mm
184±3
145±2
E
Type
Mass
[kg]
on request
A3G 710-AU21 -01
25,3
25,3
14xM10
8x
˚
45
6x6
0˚
Ø 703 ±2
22.5˚
Internal diameter of the
wall ring at least 710 mm
Ø232-2
Ø252±0.3
Ø275
70
250,5±1
Cable
gland
❮ "V"
With full square nozzle
D
284,5±5
Mass
[kg]
W3G 710-GU30 -11
W3G 710-GU21 -01
42,4
Type
Mass
[kg]
on request
S3G 710-AU21 -01
34,5
42,4
Ø14,5
Ø772
E
Type
20
810±1
850-3
170
❮ "V"
With guard grille for short nozzle
D
E
34,5
Internal diameter of the
wall ring at least 710 mm
Ø853
Ø820.2
31±4
Ø10
4
27±3
223,5±3
❮ "V"
23
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:59
Seite 24
EC axial fans - HyBlade®
Ø 800
Nominal
voltage range
Frequency
Speed/rpm (1)
Max.
power input (1)
Max.
current draw (1)
Max. operative range
Perm. amb. temp.
Mass without
attachments
VAC
Hz
rpm
kW
A
Pa
°C
kg
1~ 200-277
50/60
710
0,73
3,20
100
-25..+60
12,1
p. 37 / L3)
B
3~ 200-240
50/60
735
0,84
2,80
110
-25..+60
12,1
p. 35 / L2)
C
3~ 380-480
50/60
735
0,84
1,40
110
-25..+60
12,1
p. 39 / K3)
0°
D
3~ 200-240
50/60
1020
2,40
7,50
210
-25..+60
25,9
p. 38 / L5)
0°
E
3~ 380-480
50/60
1020
2,56
3,90
230
-25..+60
25,9
p. 38 / L5)
0°
F
3~ 200-240
50/60
1090
2,98
9,00
260
-25..+65
30,4
p. 38 / L5)
0°
G
3~ 380-480
50/60
1090
2,98
4,50
260
-25..+65
30,4
p. 38 / L5)
Curve
Blade angle
Nominal data
Type
Motor
*3G 800
M3G 112-IA
0°
A
*3G 800
M3G 112-IA
0°
*3G 800
M3G 112-IA
0°
*3G 800
M3G 150-IF
*3G 800
M3G 150-IF
*3G 800
M3G 150-NA
*3G 800
M3G 150-NA
subject to alterations
(1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC
Air performance measured
[in H2O]
[Pa]
Curves
280
as per: ISO 5801,
G
F
1,00
in ebm-papst full nozzle
and without protection against
E
240
D
accidental contact
4'
0,80
4
0,60
3
B
0,40
4
66
A
3
710
0,63
2,84
64
A
4
710
0,73
3,20
69
735
0,52
1,76
70
735
0,62
2,04
66
LwA as per ISO 13347,
B
3
735
0,72
2,36
64
LpA measured at 1 m distance
B
4
735
0,84
2,80
70
C
1
735
0,52
0,88
70
C
2
735
0,62
1,02
66
C
3
735
0,72
1,18
64
C
4
735
0,84
1,40
70
D
1
1020
1,62
4,94
75
D
2
1020
1,88
5,76
75
D
3
1020
2,15
6,58
77
D
4
1020
2,40
7,50
85
dard setup, the specific values
0,20
have to be checked and re-
40
viewed once installed or fitted!
2 2
For detailed information
24
70
2,49
With any deviation to the stan-
2
3
5000
2,15
0,55
2
installation situation.
3
4000
0,46
710
1
2
2000
710
2
B
may vary depending on the
4
0
1
A
ment conditions listed and
80
6000
10000
8000
15000
1 1
10000
12000
20000
LwA
[dB(A)]
B
The acoustic values given are
C
A
I
[A]
Suction-side noise levels:
only valid under the measur-
120
P1
[kW]
to fan axis
3
160
n
[rpm]
A
Installation category A,
4
200
Technical features and
electr. connections
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades (5): A B C Pressed-on round sheet steel plate; D E F G Insertion part
made of sheet aluminium; Both versions extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Direction of rotation: clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: A B C "B" ("F" applying to the main components as per EN), D E F G "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
14000
25000
1
1
16000 [CFM]
[m3/h]
see page 40 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:59
Seite 25
Direction of air flow
– Technical features: See electrical connections p. 37 ff.
– EMC: B C D E F G Interference emission acc. to EN 61000-6-3
A Interference emission acc. to EN 61000-6-4
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A C Variable
– Terminal box: B D E F G Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A B C GOST; UL/CSA are applied for; CCC on request
D E F G GOST, UL/CSA; CCC on request
❮ "V"
Without
attachments
❮ "V"
With full
square nozzle
❮ "V"
With guard grille
for full nozzle
A3G 800-AO81 -21
W3G 800-GO81 -21
"V"
on request
W3G 800-GO91 -13
on request
"V"
A3G 800-AO84 -01
W3G 800-GO84 -01
S3G 800-BO84 -01
"V"
on request
W3G 800-GU24 -11
on request
"V"
A3G 800-AU25 -01
W3G 800-GU25 -01
S3G 800-BU25 -01
"V"
on request
W3G 800-GV10 -11
on request
A3G 800-AV01 -01
W3G 800-GV01 -01
S3G 800-BV01 -01
"V"
"V"
S3G 800-BO81 -21
Direction of air flow "A" on request
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
E
1
1020
1,62
2,47
75
E
2
1020
1,88
2,88
75
E
3
1020
2,15
3,29
77
E
4’
1020
2,56
3,90
85
F
1
1090
1,87
5,68
76
F
2
1090
2,18
6,64
76
F
3
1090
2,50
7,62
78
F
4
1090
2,98
9,00
84
G
1
1090
1,87
2,84
76
G
2
1090
2,18
3,32
76
G
3
1090
2,50
3,81
78
G
4
1090
2,98
4,50
84
25
Drawings
p. 26 ff.
Electr. connections
p. 35 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:59
Seite 26
EC axial fans - HyBlade®
Ø 800 with motor M3G112, drawings for direction of air flow "V"
Without attachments
A
B
126±3
131±2
C
5x
Type
Mass
[kg]
A3G 800-AO81 -21
on request
A3G 800-AO84 -01
12,1
12,1
12,1
˚
Ø786±2
Ø200±1
Ø165±0.5
72
8
85
800 +20
Internal diameter of the
wall ring at least 795 mm
56.5±0.6
5xM6
Ø186±0.5
200,5±2
Core-end sleeve
Depth of screw
12-16 mm
❮ "V"
With full square nozzle
A
236.5±5
B
C
Type
Mass
[kg]
W3G 800-GO81 -21
W3G 800-GO91 -13
W3G 800-GO84 -01
33,3
Type
Mass
[kg]
S3G 800-BO81 -21
on request
S3G 800-BO84 -01
18,3
33,3
33,3
Ø857
B
Ø14.5
Cable gland
910±1
970-3
17
190
❮ "V"
With guard grille for full nozzle
A
X
126±4
X
92
B
18,3
18,3
26
15
7.5
C
15.5
66
144±3
❮ "V"
26
Ø860
Ø816+2
68
Internal diameter of the
wall ring at least 795 mm
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:59
Seite 27
EC axial fans - HyBlade®
Ø 800 with motor M3G150, drawings for direction of air flow "V"
Without attachments
D
189±3
148±2
Depth of screw
max. 25 mm
14xM10
E
F
G
Type
Mass
[kg]
on request
A3G 800-AU25 -01
on request
A3G 800-AV01 -01
25,9 250,5
g
25,9 250,5
30,4 289,5
30,4 289,5
˚
45
8x
Ø788±2
22.5˚
6x6
0˚
Internal diameter of the
wall ring at least 795 mm
70
Ø232-2
Ø252±0.3
Ø275
g ±1
Cable
gland
❮ "V"
Type
With full square nozzle
D
307±5
E
F
-11
-01
-11
-01
45,7
45,7
50,2
50,2
Ø14.5
Ø857
G
W3G 800-GU24
W3G 800-GU25
W3G 800-GV10
W3G 800-GV01
Mass
[kg]
910±1
970-3
17
190
❮ "V"
With guard grille for full nozzle
D
X
132±4
92
X
E
15
26
7.5
F
G
Type
Mass
[kg]
on request
S3G 800-BU25 -01
on request
S3G 800-BV01 -01
33,7 124,0
t
33,7 124,0
38,2 163,0
38,2 163,0
15.5
Ø816+2
Ø860
68
126,5±3
Internal diameter of the
wall ring at least 795 mm
t±3
❮ "V"
27
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:59
Seite 28
EC axial fans - HyBlade®
Ø 910
Max. operative range
Perm. amb. temp.
Mass without
attachments
12,2
p. 37 / L3)
2,20
85
-25..+60
12,2
p. 35 / L2)
1,10
85
-25..+60
12,2
p. 39 / K3)
2,10
6,40
160
-25..+60
26,4
p. 38 / L5)
2,10
3,20
160
-25..+60
26,4
p. 38 / L5)
960
2,47
7,60
170
-25..+60
30,9
p. 38 / L5)
1000
2,88
4,40
190
-25..+65
30,9
p. 38 / L5)
Max.
current draw (1)
-25..+60
Max.
power input (1)
80
Speed/rpm (1)
kg
Frequency
°C
Nominal
voltage range
Pa
VAC
Hz
rpm
kW
A
1~ 200-277
50/60
590
0,58
2,60
B
3~ 200-240
50/60
610
0,63
C
3~ 380-480
50/60
610
0,63
0°
D
3~ 200-240
50/60
885
0°
E
3~ 380-480
50/60
885
0°
F
3~ 200-240
50/60
0°
G
3~ 380-480
50/60
Curve
Blade angle
Nominal data
Type
Motor
*3G 910
M3G 112-IA
0°
A
*3G 910
M3G 112-IA
0°
*3G 910
M3G 112-IA
0°
*3G 910
M3G 150-IF
*3G 910
M3G 150-IF
*3G 910
M3G 150-NA
*3G 910
M3G 150-NA
subject to alterations
(1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC
Curves
Air performance measured
4
as per: ISO 5801,
F
0,70
[Pa]
[in H2O]
G
180
E
160
in ebm-papst full nozzle
and without protection against
4
0,60
accidental contact
140
0,50
3
1
590
0,35
1,64
67
A
2
590
0,43
1,97
66
A
3
590
0,50
2,26
66
A
4
590
0,58
2,60
71
1
610
0,39
1,38
68
B
2
610
0,48
1,40
67
LwA as per ISO 13347,
B
3
610
0,56
1,84
66
LpA measured at 1 m distance
B
4
610
0,63
2,20
70
C
1
610
0,39
0,69
68
C
2
610
0,48
0,80
67
C
3
610
0,56
0,92
66
C
4
610
0,63
1,10
70
D
1
885
1,36
4,14
76
D
2
885
1,60
4,86
75
D
3
885
1,83
5,58
75
D
4
885
2,10
6,40
78
0,40
The acoustic values given are
B
C
only valid under the measur4
ment conditions listed and
0,30
4
may vary depending on the
2
60
0,20
3
2
3
installation situation.
2
With any deviation to the standard setup, the specific values
40
have to be checked and re0,10
2 2
viewed once installed or fitted!
For detailed information
1 1
0
5000
5000
28
LwA
[dB(A)]
to fan axis
A
20
I
[A]
B
3
80
P1
[kW]
Suction-side noise levels:
3
100
n
[rpm]
A
Installation category A,
4
D
120
Technical features and
electr. connections
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades (5): A B C Pressed-on round sheet steel plate; D E F G Insertion part
made of sheet aluminium; Both versions extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Direction of rotation: clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: A B C "B" ("F" applying to the main components as per EN), D E F G "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
10000
10000
15000
1
15000
20000
25000
30000
1
1
[CFM]
[m3/h]
see page 40 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:59
Seite 29
Direction of air flow
– Technical features: See electrical connections p. 37 ff.
– EMC: B C D E F G Interference emission acc. to EN 61000-6-3
A Interference emission acc. to EN 61000-6-4
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A C Variable
– Terminal box: B D E F G Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A B C GOST; UL/CSA are applied for; CCC on request
D E F G GOST, UL/CSA; CCC on request
❮ "V"
Without
attachments
❮ "V"
With full
square nozzle
❮ "V"
With guard grille
for full nozzle
A3G 910-AO84 -21
W3G 910-GO84 -21
"V"
on request
W3G 910-GO90 -13
on request
"V"
A3G 910-AO83 -01
W3G 910-GO83 -01
S3G 910-BO83 -01
"V"
on request
W3G 910-GU31 -11
on request
"V"
A3G 910-AU22 -01
W3G 910-GU22 -01
S3G 910-BU22 -01
"V"
on request
W3G 910-GV06 -11
on request
A3G 910-AV02 -01
W3G 910-GV02 -01
S3G 910-BV02 -01
"V"
"V"
S3G 910-BO84 -21
Direction of air flow "A" on request
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
E
1
885
1,36
2,07
76
E
2
885
1,60
2,43
75
E
3
885
1,83
2,79
75
E
4
885
2,10
3,20
78
F
1
960
1,64
5,00
78
F
2
960
1,94
6,00
77
F
3
960
2,21
6,80
77
F
4
960
2,47
7,60
80
G
1
1000
1,92
2,91
79
G
2
1000
2,29
3,49
78
G
3
1000
2,60
3,97
79
G
4
1000
2,88
4,40
82
29
Drawings
p. 30 ff.
Electr. connections
p. 35 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
09:59
Seite 30
EC axial fans - HyBlade®
Ø 910 with motor M3G112, drawings for direction of air flow "V"
Without attachments
A
139±3
114±2
B
5x
C
Type
Mass
[kg]
A3G 910-AO84 -21
on request
A3G 910-AO83 -01
12,2
12,2
12,2
˚
Internal diameter of the
wall ring at least 913 mm
8
85
800 +20
Ø905±2
Ø200±1
Ø165±0.5
72
56.5±0.6
5xM6
Ø186±0.5
200,5±2
Core-end sleeve
Depth of screw
12-16 mm
❮ "V"
With full square nozzle
A
266.5±5
B
C
Type
Mass
[kg]
W3G 910-GO84 -21
W3G 910-GO90 -13
W3G 910-GO83 -01
37,0
Type
Mass
[kg]
S3G 910-BO84 -21
on request
S3G 910-BO83 -01
19,8
37,0
37,0
Ø976
B
Ø14.5
Cable gland
20
205
1010±1
1070-3
❮ "V"
With guard grille for full nozzle
A
X
135±4
X
106
B
19,8
19,8
26
15.8
10.5
C
22
70
140±3
❮ "V"
30
Ø976
Ø932+2
74
Internal diameter of the
wall ring at least 913 mm
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 31
EC axial fans - HyBlade®
Ø 910 with motor M3G150, drawings for direction of air flow "V"
Without attachments
D
188±3
115±2
14xM10
Depth of screw
max. 25 mm
E
F
G
8x
Type
Mass
[kg]
on request
A3G 910-AU22 -01
on request
A3G 910-AV02 -01
26,4 250,0
g
26,4 250,5
30,9 289,5
30,9 289,5
45
˚
22.5˚
6x6
0˚
Ø905±2
Internal diameter of the
wall ring at least 913 mm
70
Ø232-2
Ø252±0.3
Ø275
g±1
Cable
gland
❮ "V"
Type
With full square nozzle
D
307±5
E
F
-11
-01
-11
-01
51,6
51,6
56,1
56,1
Ø14.5
Ø976
G
W3G 910-GU31
W3G 910-GU22
W3G 910-GV06
W3G 910-GV02
Mass
[kg]
20
1010±1
1070-3
205
❮ "V"
With guard grille for full nozzle
D
X
137±4
X
106
E
15.8
26
10.5
F
G
Type
Mass
[kg]
on request
S3G 910-BU22 -01
on request
S3G 910-BV02 -01
35,2 137,5
t
35,2 137,5
39,7 176,5
39,7 176,5
22
113±3
Ø983
Ø931+2
74
Internal diameter of the
wall ring at least 913 mm
t±3
❮ "V"
31
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 32
EC axial fans - HyBlade®
Ø 990
Frequency
Speed/rpm (1)
Max.
power input (1)
Max.
current draw (1)
Max. operative range
Perm. amb. temp.
Mass without
attachments
VAC
Hz
rpm
kW
A
Pa
°C
kg
3~ 200-240
50/60
820
1,64
5,00
135
-25..+60
25,7
p. 38 / L5)
B
3~ 380-480
50/60
820
1,64
2,50
135
-25..+60
25,7
p. 38 / L5)
C
3~ 200-240
50/60
960
2,58
8,00
180
-25..+65
31,2
p. 38 / L5)
D
3~ 380-480
50/60
960
2,58
4,00
180
-25..+70
31,2
p. 38 / L5)
Type
Motor
*3G 990
M3G 150-IF
-5°
A
*3G 990
M3G 150-IF
-5°
*3G 990
M3G 150-NA
-5°
*3G 990
M3G 150-NA
-5°
subject to alterations
(1) Nominal data in operating point with maximum load and 400 VAC
[in H2O]
Air performance measured
C
D
as per: ISO 5801,
in ebm-papst full nozzle
and without protection against
160
0,60
accidental contact
100
3
820
0,98
2,98
80
2
820
1,22
3,70
78
A
3
820
1,46
4,46
78
A
4
820
1,64
5,00
79
1
820
0,98
1,49
80
B
2
820
1,22
1,85
78
LwA as per ISO 13347,
B
3
820
1,46
2,23
78
LpA measured at 1 m distance
B
4
820
1,64
2,50
79
C
1
960
1,49
4,54
85
C
2
960
1,90
5,76
83
C
3
960
2,26
6,86
84
C
4
960
2,58
8,00
85
D
1
960
1,49
2,27
85
D
2
960
1,90
2,88
83
D
3
960
2,26
3,43
84
D
4
960
2,58
4,00
85
only valid under the measur-
0,30
ment conditions listed and
may vary depending on the
60
0,20
2
With any deviation to the stan2
dard setup, the specific values
40
have to be checked and re0,10
viewed once installed or fitted!
For detailed information
1
0
5000
5000
32
1
B
installation situation.
20
10000
10000
15000
15000
20000
25000
LwA
[dB(A)]
Suction-side noise levels:
The acoustic values given are
3
80
I
[A]
to fan axis
0,40
120
0,50
4
P1
[kW]
A
B
A
140
n
[rpm]
A
Installation category A,
4
0,70
[Pa]
Curves
180
Technical features and
electr. connections
Nominal
voltage range
Nominal data
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
30000
1
[CFM]
[m3/h]
see page 40 ff.
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 33
Direction of air flow
– Technical features: See electrical connections p. 38
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Terminal box: Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A B C D GOST; UL/CSA; CCC on request
❮ "V"
Without
attachments
❮ "V"
With full
square nozzle
❮ "V"
With guard grille
for full nozzle
"V"
on request
W3G 990-GY32 -11
on request
"V"
A3G 990-AY28 -01
W3G 990-GY28 -01
S3G 990-BY28 -01
"V"
on request
W3G 990-GZ09 -11
on request
"V"
A3G 990-AZ02 -01
W3G 990-GZ02 -01
S3G 990-BZ02 -01
Direction of air flow "A" on request
33
Drawings
p. 34
Electr. connections
p. 38
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 34
EC axial fans - HyBlade®
Ø 990 with motor M3G150, drawings for direction of air flow "V"
Without attachments
A
175±3
106±2
14xM10
Depth of screw
max. 25 mm
B
C
Mass
[kg]
on request
A3G 990-AY28 -01
on request
A3G 990-AZ02 -01
25,7 238,0
g
h
57,5
25,7 238,0
57,5
31,2 289,5
70,0
31,2 289,5
70,0
45
8x
D
Type
˚
6x6
0˚
Ø990±2
22,5˚
Internal diameter of the
wall ring at least 1000 mm
h
Ø232-2
Ø252±0,3
Ø275
g±1
Cable gland
❮ "V"
Type
With full square nozzle
A
u±5
B
C
-11
-01
-11
-01
u
55,9 323,5
55,9 323,5
61,4 336,0
61,4 336,0
Ø14.5
Ø1063
D
W3G 990-GY32
W3G 990-GY28
W3G 990-GZ09
W3G 990-GZ02
Mass
[kg]
20
1110±1
1170-3
225
❮ "V"
With guard grille for full nozzle
A
129±4
106
X
X
B
15.8
26
10.5
C
D
Type
Mass
[kg]
on request
S3G 990-BY28 -01
on request
S3G 990-BZ02 -01
35,7 103,5 134,5
41,2 116,0 173,5
41,2 116,0 173,5
22
Ø1018+2
Ø1070
t±3
❮ "V"
34
t
35,7 103,5 134,5
74
s±3
s
Internal diameter of the
wall ring at least 1000 mm
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 35
Electrical connections EC
L2)
Alarm relay
Line undervoltage detection
Phase failure detection
Motor current limitation
Electronics / motor overtemperature protection
Locked-rotor protection
Soft start
L1
PE
KL1
NC
COM
NO
OUT
GND
+10 V
0-10 V
PWM
+20 V
KL2
4-20 mA
0-10 V
PWM
GND
RS A
RS B
RS B
RS A
KL3
L3
•
•
•
•
•
•
•
L2
Technical features:
• PFC (passive)
• Integrated PID controller
• Control input 0-10 VDC / PWM
• Input for sensor 0-10 V or 4-20 mA
• Slave output 0-10 V max. 3 mA
• Output 20 VDC (±20 %) max. 50 mA
• Output 10 VDC (+10 %) max. 10 mA
• RS485 ebmBUS
Connector Connection Assignment / function
Connector Connection Assignment / function
PE
PE
Protective earth
KL3
OUT
Master output 0-10 V max. 3 mA
KL1
L3
Mains; L3
GND
GND
L2
Mains; L2
0-10 V / PWM Control / Actual value input (Impedance 100 kΩ)
L1
Mains; L1
+10 V
NC
Alarm relay, break for failure
COM
Alarm relay, COMMON (2A, 250 VAC, AC1)
NO
Alarm relay, make for failure
KL2
Supply for external potentiometer,
10 VDC (+10 %) max. 10 mA
+20 V
Supply for external sensor,
20 VDC (±20 %) max. 50 mA
4-20 mA
Control / Actual value input
0-10 V / PWM Control / Actual value input
GND
GND
RSB
RS485 interface for ebmBUS; RS B
RSA
RS485 interface for ebmBUS; RS A
RSB
RS485 interface for ebmBUS; RS B
RSA
RS485 interface for ebmBUS; RS A
35
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 36
Electrical connections EC
K1)
Technical features:
• Control input 0-10 VDC / PWM
• Output 10 VDC max. 1.1 mA
• Alarm relay
• Electronics / motor overtemperature protection
• Line undervoltage detection
• Motor current limitation
• Locked-rotor protection
• Soft start
Notes on various control possibilities and their applications
Umin = 15 V
Imax =
10 mA
Mains
50/60 Hz
U
-
10 K
+
-
NC
white1
COM
white2
Voltage output
red
+10 V
max. 1.1 mA
+
PWM
L
black
N
blue
PE
green/yellow
12 V
Alarm relay:
Break for failure
(2 A, 250 VAC, AC1)
Lin/PWM control input
yellow
0-10 VDC /
PWM
1 μF
GND
blue
Speed setting
PWM 1 - 10 kHz
Speed setting
with variable
resistance
Full speed
Speed setting
1 V - 10 V
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 14%
start up at > 1.4 V
Customer circuit
Connection
+10 V
0-10 V
PWM
GND
green/yellow white1
COM
blue
Line 2
NC
N
black
PE
L
Line 1
Fan
white2
red
yellow
blue
Line
Connection Colour Assignment / function
Line
1
L
black
Mains 50/60 Hz, phase
2
N
blue
Mains 50/60 Hz, neutral
0-10 V / PWM yellow
Control input (Impedance 100 kΩ)
PE
green/yel
Protective earth
GND
GND
NC
white1
Alarm relay, break for failure
COM
white2
Alarm relay, COMMON
36
Connection Colour Assignment / function
+10 V
red
blue
Voltage output +10 V max. 1.1 mA
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 37
Electrical connections EC
L3)
Technical features:
• PFC (active)
• Control input 0-10 VDC / PWM
• Output 10 VDC max. 10 mA
• Alarm relay
• Electronics / motor overtemperature protection
• Line undervoltage detection
• Motor current limitation
• Locked-rotor protection, soft start
Full
speed
Speed
setting
8
8
PE
2
PE1
1-10 V
11
12
N
AC1
P
L
AC2
N
3
10 V -> n = max
1 V -> n = min
<1 V -> n = 0
4
COM
5
A1
11
10 A (T)
14
A2
NC
6
0-10 V
0-10 V
8
Speed setting
with
potentiometer
47 K
47 K
470 nF
10 V
10 V
11
11
10
Imax=10 mA
GND
12
0V
8
10 K
12
Customer circuit
Connection
Fan
N
L
COM
NC
0-10 V
+10 V
GND
Line 2
PE
Line 1
green/yellow
blue
black
white1
white2
yellow
red
blue
Line
Pin
Connection Colour
Assignment / function
1
2
PE
green/yellow
Protective earth
1
3
N
blue
Mains 50/60 Hz, neutral
1
4
L
black
Mains 50/60 Hz, phase
1
5
COM
white1
Alarm relay, COMMON (2A, max. 250 VAC, min. 10 mA, AC1)
1
6
NC
white2
Alarm relay, break for failure
2
8
0-10 V
yellow
Control input (Impedance 100 kΩ), SELV
2
11
+10 V
red
Voltage output 10 VDC (+/- 3%), max. 10 mA, supply voltage for external units (e.g. potentiometer), SELV
2
12
GND
blue
GND, SELV
37
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 38
Electrical connections EC
L5)
RS485 MODBUS
Motor current limitation, alarm relay
Line undervoltage / phase failure detection
Electronics / motor overtemperature protection
Locked-rotor protection, soft start
Digital inputs for day/night switch,
enabling, cooling / heating
L3
L2
Aout
Din1
L1
Ain2 I
Ain1 I
KL1
PE
+20 V
+10 V
NO
GND
Ain2 U
GND
Din3
RS B
KL2
Ain1 U
Din2
RS A
KL3
NC
•
•
•
•
•
•
COM
Technical features:
• PFC (passive)
• Integrated PID controller
• Control input 0-10 VDC or 4-20 mA
• Input for sensor 0-10 V or 4-20 mA
• Slave output 0-10 V max. 5 mA
• Output 20 VDC (+25 % / -10 %) max. 50 mA
• Output 10 VDC (+3 %) max. 10 mA
Connector Connection Assignment / function
Connector Connection Assignment / function
KL1
KL3
L3
Mains; L3
L2
Mains; L2
L1
Mains; L1
PE
PE
Protective earth
KL2
NC
Alarm relay, break for failure
COM
Alarm relay, COMMON (2A, 250 VAC, AC1)
NO
Alarm relay, make for failure
Din1
Digital input 1 (enabling / disabling of electronics),,
Enabling: Pin open or applied voltage 5...50 VDC
Disabling: Bridge to GND or applied voltage < 1 VDC
Ain1 I
Analogue set value input, 4-20 mA (impedance 100 Ω),
only to be used as alternative to terminal Ain1 U
+10 V
Supply for external potentiometer,
10 VDC (±3 %) max. 10 mA
Ain1U
Analogue set value input, 0-10 V (impedance 100 kΩ),
GND
GND
RSB
RS485 interface for MODBUS RTU; RS B
RSA
RS485 interface for MODBUS RTU; RS A
Aout
Analogue output 0-10 V max. 5 mA, reading of current
only to be used as alternative to terminal Ain1 I
motor speed / current motor control factor
Ain2 I
Analog. actual value input, 4-20mA (impedance 100Ω),
+20 V
Supply for external sensor,
only to be used as alternative to terminal Ain2 U
20 VDC (+25 % / -10%) max. 40 mA
Ain2 U
Analog. actual value input, 0-10 V (impedance 100 kΩ),
only to be used as alternative to terminal Ain2 I
GND
GND
Din3
Digital input 3 (switch Normal / Inverse),
The preset effective direction of the integrated
controller can be selected via BUS or via digital input
Normal/Inverse.
Normal: Pin open or applied voltage 5...50 VDC
Inverse: Bridge to GND or applied voltage < 1 VDC
Din2
Digital input 2 (switch Day / Night),
The preset set of parameters can be selected via BUS
or via digital input Day/Night.
Day: Pin open or applied voltage 5...50 VDC
Night: Bridge to GND or applied voltage < 1 VDC
38
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 39
Electrical connections EC
K3)
Technical features:
• PFC (passive)
• Control input 0-10 VDC / PWM
• Output 10 VDC (±20 %) max. 10 mA
• Alarm relay
• Electronics / motor overtemperature protection
• Line undervoltage / phase failure detection
• Motor current limitation
• Locked-rotor protection, soft start
Notes on various control possibilities and their applications
Umin = 15 V
L1
Imax =
10 mA
Mains
50/60 Hz
+
-
L2 black
L3 black
black
PE
green/yellow
NC
white1
COM
white2
Voltage output
red
+10 V
max. 10 mA
+
U
PWM
-
10 K
12 V
Alarm relay:
Break for failure
(2 A, 250 VAC, AC1)
Lin/PWM control input
yellow
0-10 VDC /
PWM
1 μF
GND
blue
Speed setting
PWM 1 - 10 kHz
Speed setting
with variable
resistance
Full speed
Speed setting
1 V - 10 V
100% PWM -> n=max
approx. 10% PWM -> n=min
< 10% PWM -> n=0
10 V -> n=max
approx. 1 V -> n=min
< 1 V -> n=0
start up at > 14%
start up at > 1,4 V
Customer circuit
Connection
+10 V
0-10 V
PWM
GND
black green/yellow white1
COM
NC
black
Line 2
PE
L2
black
L3
L1
Line 1
Fan
white2
red
yellow
blue
Line
Connection Colour Assignment / function
Line
Connection Colour Assignment / function
1
L1
black
Mains; L1
2
+10 V
L2
black
Mains; L2
0-10 V / PWM yellow
Control input (Impedance 100 kΩ)
L3
black
Mains; L3
GND
GND
PE
green/yel
Protective earth
NC
white1
Alarm relay, break for failure
COM
white2
Alarm relay, COMMON
red
blue
Voltage output +10 V max. 1.1 mA
39
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 40
Technical parameters & scope
High standards for all ebm-papst products
Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best
possible product for your application. Careful monitoring of the market ensures that technical innovations are
reflected in the improvements of our products.
Based on the technical parameters listed below and the ambience you want our product to operate in,
we here at ebm-papst can always work out the best solution for your specific application.
General performance parameters
Service life
Any deviations from the technical data and parameters described here
The service life of ebm-papst products depends on two major factors:
are listed on the product-specific data sheet.
– The service life of the insulation system
– The service life of the bearing system
Type of protection
The service life of the insulation system mainly depends on voltage level,
The type of protection is specified in the product-specific data sheets.
temperature and ambient conditions, such as humidity and condensation.
The service life of the bearing system depends mainly on the thermal load
Insulation class
on the bearing.
The insulation class is specified in the product-specific data sheets.
The majority of our products use maintenance-free ball bearings for
any mounting position possible. As an option, sleeve bearings can be
Mounting position
used, which is indicated on the product-specific data sheet wherever
The mounting position is specified in the product-specific data sheets.
applicable.
The service life L10 of the ball bearings can be taken as approx. 40,000
Condensate discharge holes
operating hours at an ambient temperature of 40 °C, yet this estimate
Information on the condensate discharge holes is provided in the
can vary according to the actual ambient conditions.
product-specific data sheets.
We will gladly provide you with a lifetime calculation taking into account
your specific operating conditions.
Mode of operation
The mode of operation is specified in the product-specific data sheets.
Motor protection / thermal protection
Information on motor protection and thermal protection is provided in the
Protection class
product-specific data sheets.
The protection class is specified in the product-specific data sheets..
Depending on motor type and field of application, the following protective
features are realised:
– Thermal overload protection (TOP), either in-circuit or external
– PTC with electronic diagnostics
– Impedance protection
– Thermal overload protection (TOP) with electronic diagnostics
– Current limitation via electronics
If an external TOP is connected, the customer has to make sure to
connect a conventional trigger device for switching it off.
Products without fitted TOP and without protection against improper use,
a motor protection complying with the valid standards has to be installed.
40
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:00
Seite 41
Left: Endurance test room
Middle: Shock test
Right: Chamber test rig
Mechanical strain / performance parameters
Legal and normative directives
All ebm-papst products are subjected to comprehensive tests complying
The products described in this catalogue are designed, developed and
with the normative specifications. In addition to this, the tests also reflect
produced in keeping with the standards in place for the relevant product
the vast experience and expertise of ebm-papst.
and, if known, the conditions governing the relevant fields of application.
Vibration test
Standards
Vibration tests are carried out in compliance with
Information on standards is provided in the product-specific data sheets.
– Vibration test in operation according to DIN IEC 68, parts 2-6
– Vibration test at standstill according to DIN IEC 68, parts 2-6
EMC
Information on EMC standards is provided in the product-specific data
Shock load
sheets.
Shock load tests are carried out in compliance with
Complying with the EMC standards has to be established on the final
– Shock load according to DIN IEC 68, parts 2-27
appliance, as different mounting situations can result in changed EMC
properties.
Balancing quality
Testing the balancing quality is carried out in compliance with
Leakage current
– Residual imbalance according to DIN ISO 1940
Information on the leakage current is provided in the product-specific
– Standard balancing quality level G 6.3
data sheets.
Should you require a higher balancing quality level for your specific
Measuring is according to IEC 60990.
application, please let us know and specify this when ordering your
product.
Approvals
In case you require a specific approval for your ebm-papst product
Chemo-physical strain / performance parameters
(VDE, UL, GOST, CCC, CSA, etc.) please let us know.
Should you have questions about chemo-physical strain, please direct
Most of our products can be supplied with the relevant approval.
them to your ebm-papst contact.
Information on existing approvals is provided in the product-specific
data sheets.
Fields of application, industries and applications
Our products are used in various industries and applications:
Air performance measurements
Ventilation, air-conditioning and refrigeration technology, clean room
All air performance measurements are carried out on suction side and on
technology, automotive and rail technology, medical and laboratory tech-
chamber test beds conforming to the specifications as per ISO 5801 and
nology, electronics, computer and office technology, telecommunications,
DIN 24163. The fans under test are installed in the measuring chamber at
household appliances, heating, machines and plants, drive engineering.
free air intake and exhaust (installation category A) and are operated at
Our products are not designed for use in the aviation and aerospace
nominal voltage, with AC also at nominal frequency, and without any
industry!
additional components such as guard grilles.
As required by the standard, the air performance curves correspond to
an air density of 1.2 kg/m3.
41
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:01
Seite 42
Room for precision noise measuring
Measurement conditions for air and noise measurement
ebm-papst products are measured under the following conditions:
– Axial and diagonal fans in direction of rotation “V” in full nozzle and
without guard grille
– Backward curved centrifugal fans, free-running and with inlet nozzle
– Forward curved single and dual inlet centrifugal fans with housing
Noise measurements
All noise measurements are carried out in low-reflective test rooms with
reverberant floor. Thus the ebm-papst acoustic test chambers meet the
requirements of precision class 1 according to DIN EN ISO 3745. For noise
measurement, the fans being tested are placed in a reverberant wall and
operated at nominal voltage (for AC, also at nominal frequency) without
additional attachments such as the guard grille.
Sound pressure level and sound level
All acoustic values are established according to ISO 13347, DIN 45635
and ISO 3744/3745 to accuracy class 2 and given in A-rated form.
When the sound pressure level (Lp) is measured, the microphone is on
the intake side of the fan being tested, usually at a distance of 1 m on
the fan axis.
To measure the sound level (Lw), 10 microphones are distributed over
an enveloping surface on the intake side of the fan being tested
1,5d
(see graphic). The sound level measured can be roughly calculated
D
from the sound pressure level by adding 7 dB.
Measuring configuration as per ISO 13347-3 respectively DIN 45635-38:
10 measuring points
h
3d
d≥D
h = 1,5d ... 4,5d
Measurement area S = 6d2 + 7d (h + 1,5d)
42
2d
10:01
Seite 43
Adding multiple noise sources with the same level
15
16.05.2011
[dB]
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
pressure level of a fan is approximately 75 dB(A). The level increase measured from the diagram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A).
10
9
Example: 8 A3G800 axial fans are on a condenser. According to the data sheet, the sound
5
the noise values specified in the data sheet. This is shown in the diagram opposite.
0
The noise characteristics of multiple identical fans can be determined in advance based on
Increase in sound pressure / sound power level
Adding 2 noise sources with the same volume results in a level increase of approx. 3 dB.
1
2
5
8
10
15
20 25
3
Adding two noise sources with different levels
[dB]
Number of sources of sound with identical level
4 dB. The level increase can now be read in the diagram as approx. 1.5 dB. This means that
the overall sound level of the unit can be expected to be 76.5 dB(A).
2
1,5
ating point and an axial fan A3G710 with 71 dB(A) in a ventilation unit. The level difference is
1
Example: There is an axial fan A3G800 with a sound pressure level of 75 dB(A) at the oper-
0
levels given in the data sheet. This is shown in the diagram opposite.
Increase in sound pressure / sound power level
The acoustic performance of two different fans can be predetermined based on the sound
0
4
8
12
16
20
24
[dB]
0
Distance laws
[dB]
Difference in level with two sources of sound
Sound power level is independent of distance to the sound source. In contrast to this, sound
-10
pressure level decreases the further away the noise source is. The adjacent diagram shows
the decrease in level under far sound field conditions. Far sound field conditions apply when-
decreases by 6 dB. In the near field of the fan, other correlations apply and the decrease in
levels can be considerably smaller. The following example only applies to far sound field
conditions and can vary strongly depending on the installation effects:
With an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of
1 m. According to the adjacent diagram, at a distance of 20 m we would get a reduction by
-20
-26
-30
vant literature on this complex topic. Per doubling of distance, the level in the far sound field
-40
wavelength to be considered. For more information on far sound field, please consult the rele-
Decrease in sound pressure level
ever the distance between microphone and fan is big when compared to fan diameter and
1
Distance
2
5
10
20
50
100
[m]
26 dB, i.e. a sound pressure level of 39 dB(A).
43
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
fan agent
compact fan agent
16.05.2011
10:01
Seite 44
ebm-papst in Germany
motor specialist
motor agent
Germany
ebm-papst
Mulfingen GmbH & Co. KG
ebm-papst
St. Georgen GmbH & Co. KG
ebm-papst
Landshut GmbH
Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
[email protected]
Hermann-Papst-Straße 1
D-78112 St. Georgen
Phone +49 7724 81-0
Fax +49 7724 81-1309
[email protected]
Hofmark-Aich-Straße 25
D-84030 Landshut
Phone +49 871 707-0
Fax +49 871 707-465
[email protected]
www.ebmpapst.com
www.ebmpapst.com
www.ebmpapst.com
44
Berlin
Dipl.-Ing. (TH) Jens Duchow
Händelstraße 7
D-16341 Panketal
Phone +49 30 944149-62
Fax +49 30 944149-63
[email protected]
Heilbronn / Heidelberg
Dipl.-Ing. Mark Gartner
Gehrweg 12
D-74199 Unterheinriet
Phone +49 7130 404569-1
Fax +49 7130 404569-2
[email protected]
Bielefeld
Dipl.-Ing. (FH) Wolf-Jürgen Weber
Niehausweg 13
D-33739 Bielefeld
Phone +49 5206 91732-31
Fax +49 5206 91732-35
[email protected]
Kassel
Dipl.-Ing. (FH) Ralph Brück
Hoherainstraße 3 b
D-35075 Gladenbach
Phone +49 6462 4071-10
Fax +49 6462 4071-11
[email protected]
Dortmund
Dipl.-Ing. (FH) Hans-Joachim Pundt
Auf den Steinern 3
D-59519 Möhnesee-Völlinghausen
Phone +49 2925 800-407
Fax +49 2925 800-408
[email protected]
Koblenz
Winfried Schaefer
Hinter der Kirch 10
D-56767 Uersfeld
Phone +49 2657 16-96
Fax +49 2657 16-76
[email protected]
Frankfurt
Dipl.-Ing. Christian Kleffmann
Dr.-Hermann-Krause-Straße 23
D-63452 Hanau
Phone +49 6181 1898-12
Fax +49 6181 1898-13
[email protected]
Munich
Dipl.-Wirt.-Ing. (FH) Jens Peter
Uhlandstraße 6
D-74427 Fichtenberg
Phone +49 7971 260-180
Fax +49 7971 260-221
[email protected]
Halle
Dipl.-Ing. (TU) Michael Hanning
Lercheneck 4
D-06198 Salzatal / OT Lieskau
Phone +49 345 55124-56
Fax +49 345 55124-57
[email protected]
Nuremberg
Dipl.-Wirt.-Ing. (FH) Axel Resch
Steinsfeldstraße 80
D-74626 Bretzfeld
Phone +49 7946 94401-02
Fax +49 7946 94401-03
[email protected]
Hamburg
Ingenieurbüro Breuell GmbH
Ing. Dirk Kahl
Elektroingenieur
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 40 538092-19
Fax +49 40 538092-84
[email protected]
Offenburg
Dipl.-Ing. (FH) Ralf Braun
Hubeneck 21
D-77704 Oberkirch
Phone +49 7802 9822-52
Fax +49 7802 9822-53
[email protected]
Stuttgart
Dipl.-Ing. (FH) Rudi Weinmann
Hindenburgstraße 100/1
D-73207 Plochingen
Phone +49 7153 9289-80
Fax +49 7153 9289-81
[email protected]
Ulm
M.Sc. Reinhard Sommerreißer
Am Silbermannpark 10
D-86161 Augsburg
Phone +49 821 6610-7023
Fax +49 821 6610-7024
[email protected]
Distributors
Frankfurt
R.E.D. Handelsgesellschaft mbH
Gutenbergstraße 3
D-63110 Rodgau - Jügesheim
Phone +49 6106 841-0
Fax +49 6106 841-111
[email protected]
www.red-elektromechanik.de
Hamburg
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 40 538092-20
Fax +49 40 538092-84
[email protected]
Munich
A. Schweiger GmbH
Ohmstraße 1
D-82054 Sauerlach
Phone +49 8104 897-0
Fax +49 8104 897-90
[email protected]
www.schweiger-gmbh.com
(1 to 5 pieces)
North
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 40 538092-20
Fax +49 40 538092-84
[email protected]
South
HDS Ventilatoren Vertriebs GmbH
Glaswiesenstraße 1
D-74677 Dörzbach
Phone +49 7937 8033520
Fax +49 7937 8033525
[email protected]
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:01
Seite 45
ebm-papst in Europe
Europe
Austria
ebm-papst Motoren & Ventilatoren GmbH
Straubingstraße 17
A-4030 Linz
Phone +43 732 321150-0
Fax +43 732 321150-20
[email protected]
www.ebmpapst.at
Belarus
ebm-papst Bel AgmbH
P.O. Box 117
BY-220138 Minsk
Phone +375 17 3851556
Fax +375 17 3851556
[email protected]
www.ebmpapst.by
Belgium
ebm-papst Benelux B.V.
Sales office Belgium-Luxemburg
Romeinsestraat 6/0101
Research Park Haasrode
B-3001 Heverlee-Leuven
Phone +32 16 396-200
Fax +32 16 396-220
[email protected]
www.ebmpapst.be
Bulgaria
ebm-papst Romania S.R.L.
Str. Tarnavei Nr. 20
RO-500327 Brasov
Phone +40 268 312-805
Fax +40 268 312-805
[email protected]
Croatia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
[email protected]
Czech Republic / Slovakia
ebm-papst CZ s.r.o.
Kaštanová 34a
CZ-620 00 Brno
Phone +420 544 502-411
Fax +420 547 232-622
[email protected]
www.ebmpapst.cz
Denmark
ebm-papst Denmark ApS
Vallensbækvej 21
DK-2605 Brøndby
Phone +45 43 631111
Fax +45 43 630505
[email protected]
www.ebmpapst.dk
Estonia
ebm-papst Oy, Eesti Filiaal
Kesk tee 13
Aaviku küla, Jüri Tehnopark
EST-75301 Rae Vald, Harjumaa
Phone +372 65569-78
Fax +372 65569-79
www.ebmpapst.ee
Finland
ebm-papst Oy
Puistotie 1
FIN-02760 Espoo
Phone +358 9 887022-0
Fax +358 9 887022-13
[email protected]
www.ebmpapst.fi
France
ebm-papst sarl
ZI Nord - rue A. Mohler
BP 62
F-67212 Obernai Cedex
Phone +33 820 326266
Fax +33 3 88673883
[email protected]
www.ebmpapst.fr
Greece
Helcoma
Th. Rotas & Co OE
Davaki 65
GR-17672 Kallithea-Attiki
Phone +30 210 9513-705
Fax +30 210 9513-490
[email protected]
www.helcoma.gr
Hungary
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
[email protected]
Iceland
RJ Engineers
Stangarhyl 1a
IS-110 Reykjavik
Phone +354 567 8030
Fax +354 567 8015
[email protected]
www.rj.is
Ireland
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 1245 468555
Fax +44 1245 466336
[email protected]
www.ebmpapst.co.uk
AuBren Limited
Portlaoise Business & Technology Park
Mountrath Road
IRL-Portlaoise, Co. Laois
Phone +353 57 8664343
Fax +353 57 8664346
[email protected]
www.aubren.com
Italy
ebm-papst Srl
Via Cornaggia 108
I-22076 Mozzate (Co)
Phone +39 0331 836201
Fax +39 0331 821510
[email protected]
www.ebmpapst.it
Macedonia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
[email protected]
45
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
fan agent
compact fan agent
16.05.2011
10:01
Seite 46
ebm-papst in Europe
motor specialist
motor agent
Netherlands
ebm-papst Benelux B.V.
Engelseweg 127
NL-5705 AC Helmond
Phone +31 492 502-900
Fax +31 492 502-950
[email protected]
www.ebmpapst.nl
Russia
ebm-papst Ural GmbH
Posadskaja-Strasse, 23(E), 3
RU-620102 Ekaterinburg
Phone +7 343 2338000
Fax +7 343 2337788
[email protected]
www.ebmpapst.ur.ru
Switzerland
ebm-papst AG
Rütisbergstrasse 1
CH-8156 Oberhasli
Phone +41 44 73220-70
Fax +41 44 73220-77
[email protected]
www.ebmpapst.ch
Norway
ebm-papst AS
P.B. 173 Holmlia
N-1203 Oslo
Phone +47 22 763340
Fax +47 22 619173
[email protected]
www.ebmpapst.no
ebm-papst Rus GmbH
proezd 4529, vladenie 5, stroenie 1
RU-141000 Mytistschi, Oblast Moskau
Phone +7 495 9807524
Fax +7 495 5140924
[email protected]
www.ebmpapst.ru
Turkey
Akantel Elektronik San. Tic. LTD. Sti.
Atatürk Organize Sanayi
Bölgesi 10007 SK. No.:6
TR-35620 Cigli-Izmir
Phone +90 232 3282090
Fax +90 232 3280270
[email protected]
www.ebmpapst.com.tr
Poland
ebm-papst Polska Sp. z o.o.
ul. Annopol 4A
PL-03236 Warszawa
Phone +48 22 6757819
Fax +48 22 6769587
[email protected]
www.ebmpapst.pl
Portugal
ebm-papst (Portugal), Lda.
Centro Empresarial de Alverca
Rua de Adarse, Vale D’Ervas
Corpo D / Fracção 3
P-2615-178 Alverca do Ribatejo
Phone +351 218 394 880
Fax +351 218 394 759
[email protected]
www.ebmpapst.pt
Romania
ebm-papst Romania S.R.L.
Str. Tarnavei Nr. 20
RO-500327 Brasov
Phone +40 268 312-805
Fax +40 268 312-805
[email protected]
46
Serbia & Montenegro
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
[email protected]
Spain
ebm-papst Ibérica S.L.
Avda. del Sistema Solar, 29
E-28830 San Fernando de Henares (Madrid)
Phone +34 91 6780894
Fax +34 91 6781530
[email protected]
Sweden
ebm-papst AB
Äggelundavägen 2
S-17562 Järfälla
Phone +46 8 7619400
Fax +46 8 362306
[email protected]
www.ebmpapst.se
Ukraine
ebm-papst Ukraine LLC
Lepse Boulevard, 4, Building 47
UA-03067 Kiev
Phone +38 044 2063091
Fax +38 044 2063091
[email protected]
www.ebmpapst.ua
United Kingdom
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 1245 468555
Fax +44 1245 466336
[email protected]
www.ebmpapst.co.uk
ebm-papst Automotive & Drives (UK) Ltd.
The Smithy
Fidlers Lane
GB-East Ilsley, Berkshire RG20 7LG
Phone +44 1635 2811-11
Fax +44 1635 2811-61
A&[email protected]
www.ebmpapst-ad.com
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:01
Seite 47
ebm-papst in America and Africa
America
Argentina
ebm-papst de Argentina S.A.
Hernandarias 148 Lomas del Mirador
Pcia. de Buenos Aires (1752)
Phone +54 11 46576135
Fax +54 11 46572092
[email protected]
www.ebmpapst.com.ar
Brasil
ebm-papst Motores Ventiladores Ltda.
Av. José Giorgi, 301 Galpões B6+B7
Condominio Logical Center
BR-06707-100 Cotia - São Paulo
Phone +55 11 4613-8700
Fax +55 11 3164-8924
[email protected]
www.ebmpapst.com.br
USA
ebm-papst Inc.
P.O. Box 4009
100 Hyde Road
USA-Farmington, CT 06034
Phone +1 860 674-1515
Fax +1 860 674-8536
[email protected]
www.ebmpapst.us
ebm-papst Automotive & Drives, Inc.
3200 Greenfield, Suite 255
USA-Dearborn, MI 48120
Phone +1 313 406-8080
Fax +1 313 406-8081
[email protected]
www.ebmpapst-automotive.us
Africa
South Africa
ebm-papst South Africa (Pty) Ltd.
P.O. Box 3124
1119 Yacht Avenue
ZA-2040 Honeydew
Phone +27 11 794-3434
Fax +27 11 794-5020
[email protected]
www.ebmpapst.co.za
Canada
ebm-papst Canada Inc.
1800 Ironstone Manor, Unit 2
CDN-Pickering, Ontario, L1W3J9
Phone +1 905 420-3533
Fax +1 905 420-3772
[email protected]
www.ebmpapst.ca
Mexico
ebm Industrial S.de R.L. de C.V.
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
MEX-Mexico 05120, D.F.
Phone +52 55 3300-5144
Fax +52 55 3300-5243
[email protected]
www.ebmpapst.com.mx
47
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
fan agent
compact fan agent
16.05.2011
10:01
Seite 48
ebm-papst in Asia and Australia
motor specialist
motor agent
Asia
China
ebm-papst Ventilator (Shanghai) Co., Ltd.
No. 418, Huajing Road
WaiGaoQiao Free Trade Zone
No. 2001, Yang Gao (N) Road
VRC-200131 Shanghai, P.R. of China
Phone +86 21 5046-0183
Fax +86 21 5046-1119
[email protected]
www.ebmpapst.com.cn
Hong Kong
ebm-papst Hong Kong Ltd.
Unit No. 13,9 / F
Technology Park, 18 On Lai Street
Siu Lek Yuen, Shatin N.T.
Hong Kong - P.R. of China
Phone +852 2145-8678
Fax +852 2145-7678
[email protected]
India
ebm-papst India Pvt. Ltd.
26/3, G.N.T. Road, Erukkencherry
IND-Chennai-600118
Phone +91 44 25372556
Fax +91 44 25371149
[email protected]
www.ebmpapst.in
Indonesia
ebm-papst Indonesia
Representative Office
German Centre, 4th Floor, Suite 4470
Jl. Kapt. Subijono Dj. Bumi Serpong Damai
RI-15321 Tangerang
Phone +62 21 5376250
Fax +62 21 5388305
[email protected]
Israel
Polak Bros. Import Agencies Ltd.
9 Hamefalsim Street
IL-Kiryat Arie, Petach-Tikva 49514
Phone +972 3 9100300
Fax +972 3 5796679
[email protected]
www.polak.co.il
48
Japan
ebm-papst Industries Japan K.K.
12 Floor, Benex S-3 Bldg.
3-20-8 Shinyokohama, Kohoku-ku
J-222-0033 Yokohama
Phone +81 45 47057-51
Fax +81 45 47057-52
[email protected]
www.ebmpapst.jp
Korea
ebm-papst Korea Co. Ltd.
6F, Trutec Bldg.
B 6-2, Digital Media City (DMC)
Sangam-Dong, Mapo-Gu
ROK-Seoul 121-270
Phone +82 2 366213-24
Fax +82 2 366213-26
[email protected]
www.ebmpapst.co.kr
Malaysia
ebm-papst Malaysia
Representative Office
Unit 12-2, Jalan USJ Sentral 3
Persiaran Subang, Selangor Darul Ehsan
MAL-47600 Subang Jaya
Phone +60 3 8024-1680
Fax +60 3 8024-8718
[email protected]
Singapore
ebm-papst SEA Pte. Ltd.
No. 23 Ubi Road 4
#06-00 Olympia Industrial Building
SGP-Singapore 408620
Phone +65 65513789
Fax +65 68428439
[email protected]
Taiwan
ETECO Engineering & Trading Corp.
10F-I, No. 92, Teh-Wei Str.
RC-Tsow-Inn District, Kaohsiung
Phone +886 7 557-4268
Fax +886 7 557-2788
[email protected]
www.ebmpapst.com.tw
Thailand
ebm-papst Thailand Co., Ltd.
99/349 Na-Nakorn Bldg., 4th Floor
Chaeng Wattana Road, Thungsonghong,
THA-10210 Laksi, BKK
Phone +66 2 57615-24
Fax +66 2 57615-42
[email protected]
United Arab Emirates
ebm-papst Middle East FZE
PO Box 17755
Jebel Ali Free Zone / FZS1 / AP05
UAE-Dubai
Phone +971 4 88608-26
Fax +971 4 88608-27
[email protected]
www.ebmpapst.ae
Vietnam
ebm-papst Vietnam
Representative Office
Room #102, 25 Nguyen Van Thu Street
District 1
VN-Ho Chi Minh City
Phone +84 8 39104099
Fax +84 8 39103970
[email protected]
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:01
Seite 49
Australia
Australia
ebm-papst A&NZ Pty Ltd.
10 Oxford Road
AUS-Laverton North, Victoria, 3026
Phone +61 3 9360-6400
Fax +61 3 9360-6464
[email protected]
www.ebmpapst.com.au
New Zealand
ebm-papst A&NZ Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 9 837-1884
Fax +64 9 837-1899
[email protected]
www.ebmpapst.com.au
49
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
Notes
50
16.05.2011
10:01
Seite 50
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:01
Seite 51
51
EC_HyBlade_US_Edition_16_05_2011_EN:Vorlage
16.05.2011
10:01
Seite 52
37845-7-8811
ebm-papst
Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
[email protected]
www.ebmpapst.com