AC axial fan overview
AC axial fans
2016-01
DC axial fans
Information
AC axial fans
205
206
AC axial fans
Technical information
Product line
Bearings
The renowned ebm-papst AC fans are used when DC voltage is not
AC fans with sleeve bearings are powered by Class E insulated motors.
available. The AC range of fans is based on experience gained from
Fans with ball bearings are equipped with Class B, E or F insulated
decades of development activity, millions of units in series production
motors.
and competence in innovation of a world-wide technological leader.
Degree of protection
A wide range of fans for AC operation is presented in this catalogue. In
All fans are equipped with degree of protection IP 20 as standard.
addition to complete device fans, you will also find fans without external
IP 54 / IP 68 and further degrees of protection are available on request.
housing, providing a particularly economical advantage when the air duct
can be integrated in the respective device.
AC voltage
The line of AC fans for Euro voltage according
Variety of sizes
to IEC 60038 (230 V + 6 %, -10 %) is basically also available for 115 V.
AC fans are available in a variety of sizes with either air exhaust or air
intake over struts. Silent running models with sleeve bearings.
Frequencies
Electrical connection with plug connection or external leads are available.
AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their
technical data then changes accordingly.
Shaded-pole or capacitor motors
Fan drives by shaded-pole or capacitor motors, most of which incorporate
Capacitor
the world-famous ebm-papst external rotor principle: The fan blades are
Fans driven by capacitor external motors
directly attached to the external rotor of the external rotor motor, thus
provide particularly high operating efficiency. Generally, the required
combining both high performance and profitability.
operating capacitor is already integrated in the fan housing.
Flat built AC fans
Overloading
ebm-papst also has particularly flat built AC fans with internal rotor motor.
Almost all AC fans are protected against overloading (e.g. due to locked
Their advantage: quick start to full speed. A plastic impeller and the both
rotor) the drive motors are either impedance protected (marked
smaller and lighter internal rotor motor lead to a lower moment of inertia.
“Impedance protected”, and/or “Z.P.”) or are equipped with a thermal
switch (marked “Thermally protected” or “Th.P.”). The model designation
2016-01
of these fans ends with “S”.
204
Information
DC axial fans
Axial fans for AC operation
Page
Air flow
20
30
40
50
60
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000
3000
c
80 x 38
8000 N
30...61
Ø
76 x 37
8000 TV
24...47
207
92 x 25
3900
31...70
208
92 x 38
3000
49...89
209
9900
84...135
210
4000 N
80...180
211
212
c
c 119 x 25
c 119 x 38
c 119 x 38
Ø 108 x 37
c 127 x 38
c 135 x 38
4000 Z
100...180
4600 TZ
125...140
5900
150...206
206
213
129
214
5600
235...270
215
150 x 172 x 38
7000
320...380
216
Ø 150 x 55
7800
325...380
217
Ø 150 x 55
7400
380...425
218
Ø 172 x 51
6000
375...500
219
W2E 200
880...1030
220
W2E 250
1865
222
c 225 x 80
c 280 x 80
Ø
200
K2E 200
765...840
224
Ø
200
K2E 200
765...850
226
Ø
200
K2D 200
780...880
228
DC fans - specials
c
DC centrifugal fans
10
m3/h
mm
ACmaxx / EC fans
Series
Dimension
Overview of air performance
Subject to alterations
tion
Salt
Page
•
•
•
•
206
–
–
–
208
•
•
•
209
–
–
–
210
•
•
•
•
•
•
•
•
•
211
–
–
–
214
Axial fan
OPTIONAL
p.
5600
ja
–
•
•
•
•
•
•
•
•
•
•
•
–
•
215
150 x 172 x 38
7000
ja
–
–
–
–
–
216
Ø 150 x 55
7800
ja
•
–
–
–
–
217
Ø 150 x 55
7400
ja
–
–
–
–
–
218
Ø 172 x 51
6000
ja
–
–
–
–
–
219
Ø 76 x 37
c 92 x 25
c 92 x 38
c 119 x 25
c 119 x 38
c 119 x 38
Ø 108 x 37
c 127 x 38
c 135 x 38
8000 N
ja
/
–
8000 TV
ja
/
–
3900
ja
/
–
3000
ja
/
–
9900
ja
/
–
4000 N
ja
/
4000 Z
ja
/
•
•
4600 TZ
ja
/
–
5900
ja
/
–
207
AC centrifugal fans
Series
c 80 x 38
212
213
Accessories
mm
Subject to alterations
– not yet available
Sleeve bearings
Ball bearings
205
2016-01
• available
Representatives
fog p
IP 68
•
•
AC axial fans
rotec
ectio
prot
= 54
IP >
nal
idity
d sig
Hum
Spee
Sinte
c
ball sleeve b
bear earing
ings
s/
Dim
VDE
,
ensio
UL, C
n
SA
n
Overview of technically feasible designs
61 m /h
AC axial fans
3
 80 x 38 mm
– Material:
–
–
–
Nominal voltage
Frequency
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Input power
Nominal speed
Temperature range
Service life L10
at 40 °C
m3/h
cfm
VAC
Hz
dB(A)
Bel(A)
/
Watts
rpm
°C
Hours
8880 N
30
17,7
230
50
18
3,3
9,0
1 750
-10...+80
60 000 / 25 000
8850 N
37
21,8
230
50
24
3,9
12,5
2 150
-10...+70
52 500 / 25 000
8550 N
50
29,4
230
50
30
4,4
12,0
2 700
-10...+70
52 500 / 25 000
8556 N
50
29,4
230
50
31
4,5
12,0
2 800
-40...+90
52 500 / 15 000
8830 N
36
21,2
115
60
21
3,7
8,0
1 950
-10...+80
62 500 / 25 000
8800 N
47
27,7
115
60
28
4,3
11,0
2 500
-10...+70
55 000 / 27 500
8500 N
61
35,9
115
60
34
4,8
11,0
3 200
-10...+75
55 000 / 25 000
8506 N
61
35,9
115
60
35
5,0
11,0
3 300
-40...+95
55 000 / 15 000
Series 8000 N
Nominal data
Type
at T max
Air flow
– Possible special versions:
(See page 12)
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
Air flow
–
–
Housing: Die-cast aluminium
Impeller: Painted sheet steel
Direction of air flow: Exhaust over struts
Direction of rotation: Clockwise, seen on rotor
Connection:
Via 2 single wires
grounding lug for M4 x 8
Mass:
490 g
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 188.
Hours
Subject to alterations
Fan type
8880 N
8830 N
8556 N
8506 N
8800 N
8550 N
8500 N
8850 N
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
206
Guard grilles
from p. 242
tin-pla
ted
Curve
max.
Length “L”
Lead wires
310 mm long
AWG 18, TR 64
310 mm long
AWG 22
440 mm long
AWG 18, TR 64
➀
➁
➂
➂
➃
➄
➅
➅
47 m /h
Information
max.
AC axial fans
3
Ø 76 x 37 mm
– Possible special versions:
Impeller: Die-cast aluminium
(See page 12)
Mounting bracket: Metal
- Humidity protection
Direction of air flow: Exhaust over mounting bracket
- Salt fog protection
Direction of rotation: Clockwise, seen on rotor
- Degree of protection: IP 54 / IP 68
Connection:
Via 2 single wires
Mass:
370 g
Temperature range
Service life L10
at 40 °C
9,0
1 650
-10...+80
60 000 / 25 000
20
12,0
2 100
-10...+70
52 500 / 25 000
50
27
12,0
2 650
-10...+70
52 500 / 25 000
50
28
12,0
2 750
-40...+90
52 500 / 15 000
115
60
18
8,0
1 850
-10...+80
62 500 / 25 000
21,2
115
60
24
11,0
2 450
-10...+70
55 000 / 27 500
27,7
115
60
32
11,0
3 150
-10...+75
55 000 / 25 000
27,7
115
60
33
11,0
3 250
-40...+95
55 000 / 15 000
dB(A)
8880 TV
24
14,1
230
50
8850 TV
31
18,2
230
50
8550 TV
40
23,5
230
8556 TV
40
23,5
230
8830 TV
27
15,9
8800 TV
36
8500 TV
47
8506 TV
47
DC fans - specials
Hz
Hours
ACmaxx / EC fans
VAC
Type
Subject to alterations
Lead wires
325 mm long
AWG 18, TR 64
8506 TV
325 mm long
AWG 18
3
37 +1
AC centrifugal fans
AWG 18, TR 64
8500 TV
3,7 + 0,15
325 mm long
10
R4
101 + 0,2
0,3
tin-plated
90°
207
2016-01
8556 TV
8800 TV
ø75,8
8550 TV
8830 TV
6 +1
8850 TV
AC axial fans
Length “L”
8880 TV
Accessories
Fan type
325 +10
The air flow and noise level of fans without external
housing depends on the installation conditions. The
stated air flow and noise has been measured with an
orifice 76.5 mm Ø at a distance of approx. 17 mm from
the mounting bracket. Under exceptionally favourable
mounting conditions, the air flow of fan series 8000 N
is achievable. The noise in the optimal operating range
can only be measured for these fans in a specific
application.
Representatives
cfm
Nominal data
DC centrifugal fans
Nominal speed
15
m3/h
Series 8000 TV
at T max
Input power
Hours
Sound pressure level
°C
Frequency
rpm
Nominal voltage
Watts
Air flow
/
Air flow
Sintec sleeve bearings
Ball bearings
–
–
–
–
DC axial fans
– Material:
70 m /h
AC axial fans
3
 92 x 25 mm
– Material:
–
–
–
Nominal speed
Temperature range
Service life L10
at 40 °C
1 550
-10...+80
70 000 / 27 500
6,0
1 550
-40...+80
70 000 / 27 500
29
4,2
6,0
2 150
-10...+80
70 000 / 27 500
29
4,2
6,0
2 150
-40...+80
70 000 / 27 500
50
35
4,7
11,0
2 650
-20...+80
55 000 / 20 000
230
50
35
4,7
11,0
2 650
-40...+80
55 000 / 20 000
23,0
115
60
27
4,0
5,0
1 850
-10...+80
70 000 / 27 500
23,0
115
60
27
4,0
5,0
1 850
-40...+80
70 000 / 27 500
53
31,2
115
60
34
4,6
5,0
2 600
-10...+80
70 000 / 27 500
53
31,2
115
60
34
4,6
5,0
2 600
-40...+80
70 000 / 27 500
3900
70
41,2
115
60
40
5,1
9,0
3 150
-20...+80
60 000 / 22 500
3906
70
41,2
115
60
40
5,1
9,0
3 150
-40...+80
60 000 / 22 500
cfm
VAC
Hz
dB(A)
Bel(A)
3950 L
31
18,2
230
50
24
3956 L
31
18,2
230
50
24
3950 M
45
26,5
230
50
3956 M
45
26,5
230
50
3950
59
34,7
230
3956
59
34,7
3900 L
39
3906 L
39
3900 M
3906 M
Nominal data
Type
Subject to alterations
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
208
Guard grilles
from p. 242
Connection cables
p. 255
at T max
Input power
6,0
3,8
Sound power level
3,8
Sound pressure level
Hours
Frequency
°C
Nominal voltage
rpm
Air flow
Watts
Air flow
/
m3/h
Series 3900
2016-01
– Possible special versions:
(See page 12)
- Humidity protection
Sintec sleeve bearings
Ball bearings
–
–
Housing: Die-cast aluminium
Impeller: Mineral-reinforced
plastic PA
Direction of air flow: Exhaust over struts
Direction of rotation: Counter-clockwise, seen
on rotor
Connection:
Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4
Mass:
280 g
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 189.
Curve
max.
Hours
➀
➀
➁
➁
➂
➂
➃
➃
➄
➄
➅
➅
Information
AC axial fans
3
 92 x 38 mm
Service life L10
at 40 °C
DC centrifugal fans
Temperature range
1 750
-10...+75
60 000 / 27 500
9,0
1 950
-40...+90
60 000 / 20 000
32
4,4
8,5
2 300
-10...+80
60 000 / 25 000
33
4,5
8,5
2 400
-40...+90
60 000 / 20 000
50
36
4,8
12,0
2 650
-10...+55
52 500 / 37 500
230
50
37
4,9
12,0
2 700
-40...+75
52 500 / 22 500
31,8
115
60
26
3,9
8,0
1 900
-10...+80
62 500 / 25 000
35,3
115
60
29
4,2
8,0
2 150
-40...+95
62 500 / 17 500
73
43,0
115
60
35
4,6
8,0
2 500
-10...+80
62 500 / 25 000
73
43,0
115
60
36
4,7
8,0
2 600
-40...+95
62 500 / 17 500
3600
89
52,4
115
60
41
5,1
11,0
3 100
-10...+65
55 000 / 30 000
3606
89
52,4
115
60
42
5,2
11,0
3 200
-40...+75
55 000 / 25 000
m3/h
cfm
VAC
Hz
dB(A)
Bel(A)
3850
49
28,8
230
50
24
3856
54
31,8
230
50
26
3550
67
39,4
230
50
3556
67
39,4
230
50
3650
75
44,1
230
3656
75
44,1
3800
54
3806
60
3500
3506
Hours
➀
➁
➂
➂
➃
➃
➄
➅
➆
➆
➇
➇
Subject to alterations
Length “L”
With sleeve bearings
310 mm long
Lead wires
AWG 18, TR 64
With ball bearings
310 mm long
AWG 18
Guard grilles
from p. 242
tin-pla
ted
209
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
AC centrifugal fans
Fan type
Representatives
Nominal data
DC fans - specials
Nominal speed
9,0
3,9
Type
Series 3000
at T max
Input power
3,7
Sound power level
Hours
Sound pressure level
°C
Frequency
rpm
Nominal voltage
Watts
Air flow
/
Air flow
Sintec sleeve bearings
Ball bearings
–
–
– Possible special versions:
(See page 12)
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
ACmaxx / EC fans
–
–
–
Housing: Die-cast aluminium
Impeller: Painted sheet steel
Direction of air flow: Exhaust over struts
Direction of rotation: Clockwise, seen on rotor
Connection:
Via 2 single wires
grounding lug for M4 x 8
Mass:
420 g
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 189.
AC axial fans
– Material:
DC axial fans
89 m /h
Curve
max.
135 m /h
AC axial fans
3
 119 x 25 mm
– Material:
–
–
–
Nominal voltage
Frequency
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Input power
Nominal speed
Temperature range
Service life L10
at 40 °C
cfm
VAC
Hz
dB(A)
Bel(A)
/
Watts
rpm
°C
Hours
9956 L
84
49,4
230
50
29
4,4
9,5
1 850
-40...+80
57 500 / 22 500
9956 M
104
61,2
230
50
35
4,7
10,0
2 250
-40...+80
57 500 / 22 500
9950
117
68,9
230
50
37
5,0
14,0
2 450
-20...+70
47 500 / 22 500
9956
117
68,9
230
50
37
5,0
14,0
2 450
-40...+70
47 500 / 22 500
9906 L
100
58,9
115
60
34
4,6
8,0
2 100
-40...+80
62 500 / 25 000
Nominal data
Type
at T max
Air flow
m3/h
Series 9900
Hours
9906 M
111
65,3
115
60
37
5,0
8,0
2 450
-40...+80
62 500 / 25 000
9900
135
79,5
115
60
42
5,4
12,0
2 850
-20...+70
52 500 / 25 000
9906
135
79,5
115
60
42
5,4
12,0
2 850
-40...+70
52 500 / 25 000
Subject to alterations
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
2016-01
– Possible special versions:
(See page 12)
- Humidity protection
Air flow
–
–
Housing: Die-cast aluminium
Impeller: Mineral-reinforced
plastic PA
Direction of air flow: Exhaust over struts
Direction of rotation: Counter-clockwise, seen
on rotor
Connection:
Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4
Mass:
320 g
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 192.
210
Guard grilles
from p. 242
Connection cables
p. 255
Curve
max.
➀
➁
➂
➂
➃
➄
➅
➅
Information
 119 x 38 mm
Nominal speed
Temperature range
Service life L10
at 40 °C
11,0
1 550
-10...+70
55 000 / 27 500
4,4
10,0
1 800
-10...+70
57 500 / 27 500
41
5,2
18,0
2 350
-10...+55
40 000 / 27 500
44
5,4
16,5
2 550
-10...+55
42 500 / 30 000
50
46
5,4
19,0
2 650
-10...+55
37 500 / 27 500
230
50
47
5,5
19,0
2 650
-40...+85
37 500 / 15 000
50
115
60
26
4,1
10,0
1 650
-10...+75
57 500 / 25 000
57
115
60
32
4,3
9,0
1 750
-10...+75
60 000 / 27 500
151
89
115
60
45
5,4
16,0
2 700
-10...+65
42 500 / 25 000
169
100
115
60
48
5,7
15,0
3 000
-10...+65
47 500 / 25 000
4600 N
180
106
115
60
50
5,7
18,0
3 100
-10...+60
40 000 / 25 000
4606 N
180
106
115
60
51
5,8
18,0
3 100
-40...+90
40 000 / 15 000
m3/h
cfm
VAC
Hz
dB(A)
Bel(A)
4890 N
80
47
230
50
25
4850 N*
100
59
230
50
32
4580 N*
123
72
230
50
4550 N*
145
85
230
50
4650 N
160
94
230
4656 N
160
94
4840 N
85
4800 N*
97
4530 N*
4500 N*
Series 4000 N
Type
Hours
➀
➁
➂
➃
➄
➄
➅
➆
➇
➈
➉
➉
Subject to alterations
Accessories
AC centrifugal fans
* Fan with 3 blades.
Guard grilles
from p. 242
Connection cables
p. 255
211
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
Representatives
Nominal data
at T max
Input power
4,0
Sound power level
Hours
Sound pressure level
°C
Frequency
rpm
Nominal voltage
Watts
Air flow
/
Air flow
Sintec sleeve bearings
Ball bearings
–
–
– Possible special versions:
(See page 12)
- Speed signal
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
DC fans - specials
–
–
– Optionally available:
Variants with strengthened mounting
flanges and customizable single
strands
ACmaxx / EC fans
–
Housing: Die-cast aluminium
Impeller: Painted sheet steel
Direction of air flow: Intake over struts
Types 4890 N and 4840 N
exhaust over struts
Direction of rotation: Clockwise, seen on rotor
Connection:
Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4
Mass:
550 g
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 192.
AC axial fans
– Material:
DC axial fans
AC axial fans
3
DC centrifugal fans
180 m /h
Curve
max.
180 m /h
AC axial fans
3
 119 x 38 mm
– Material:
–
–
–
Nominal speed
Temperature range
Service life L10
at 40 °C
1 700
-10...+65
50 000 / 27 500
13,0
1 700
-40...+75
50 000 / 20 000
30
4,3
13,0
1 900
-10...+65
50 000 / 27 500
30
4,3
13,0
1 900
-40...+75
50 000 / 20 000
50
40
5,3
19,0
2 650
-10...+50
37 500 / 30 000
230
50
40
5,3
19,0
2 650
-40...+75
37 500 / 17 500
62
115
60
28
4,1
12,0
1 800
-10...+70
52 500 / 25 000
62
115
60
28
4,1
12,0
1 800
-40...+75
52 500 / 17 500
120
71
115
60
32
4,4
12,0
2 000
-10...+70
52 500 / 25 000
120
71
115
60
32
4,4
12,0
2 000
-40...+75
52 500 / 17 500
4600 Z
180
106
115
60
45
5,6
18,0
3 100
-10...+60
40 000 / 25 000
4606 Z
180
106
115
60
45
5,6
18,0
3 100
-40...+85
40 000 / 15 000
cfm
VAC
Hz
dB(A)
Bel(A)
100
59
230
50
26
100
59
230
50
26
4580 Z
115
68
230
50
4586 Z
115
68
230
50
4650 Z
160
94
230
4656 Z
160
94
4800 Z
105
4806 Z
105
4530 Z
4536 Z
Nominal data
Type
4850 Z
4856 Z
Subject to alterations
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
212
Guard grilles
from p. 242
Connection cables
p. 255
at T max
Input power
13,0
4,0
Sound power level
4,0
Sound pressure level
Hours
Frequency
°C
Nominal voltage
rpm
Air flow
Watts
Air flow
/
m3/h
Series 4000 Z
2016-01
– Possible special versions:
(See page 12)
- Speed signal
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
Sintec sleeve bearings
Ball bearings
–
–
Housing: Die-cast aluminium
Impeller: Painted sheet steel
Direction of air flow: Exhaust over struts
Direction of rotation: Clockwise, seen on rotor
Connection:
Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4 x 8
Mass:
540 g
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 192.
Curve
max.
Hours
➀
➀
➁
➁
➂
➂
➃
➃
➄
➄
➅
➅
140 m /h
Information
max.
AC axial fans
3
Ø 108 x 37 mm
– Possible special versions:
Impeller: Die-cast aluminium
(See page 12)
Mounting bracket: Metal
- Humidity protection
Direction of air flow: Exhaust over mounting bracket
- Salt fog protection
Direction of rotation: Clockwise, seen on rotor
- Degree of protection: IP 54 / IP 68
Connection:
Via 2 single wires
Mass:
430 g
4650 TZ
125
73,6
230
50
42
4656 TZ
125
73,6
230
50
42
4600 TZ
140
82,4
115
60
4606 TZ
140
82,4
115
60
DC centrifugal fans
/
rpm
°C
Hours
19,0
2 600
-10...+50
37 500 / 30 000
19,0
2 600
-40...+65
37 500 / 20 000
45
18,0
2 950
-10...+50
40 000 / 32 500
45
18,0
2 950
-40...+75
40 000 / 17 500
at T max
Watts
DC fans - specials
dB(A)
Hours
ACmaxx / EC fans
Sintec sleeve bearings
Ball bearings
Hz
Subject to alterations
Fan type
Lead wires
4650 TZ
4600 TZ
AWG 22, TR 32
4656 TZ
4606 TZ
AWG 18
AC centrifugal fans
37 + 1
3
Accessories
0,5 + 0,3
375 +10
6 +1
148,2 + 0,2
ø108 + 0,3
R4
16
4,3 + 0,15
AC axial fans
The air flow and noise level of fans without external
housing depends on the installation conditions. The
stated air flow and noise has been measured with an
orifice 109 mm Ø at a distance of approx. 17 mm from
the mounting bracket. Under exceptionally favourable
mounting conditions, the air flow of fan series 4000 Z
is achievable. The noise in the optimal operating range
can only be measured for these fans in a specific
application.
tin-plated
213
2016-01
90°
Representatives
Sound pressure level
VAC
Service life L10
at 40 °C
Frequency
cfm
Temperature range
Nominal voltage
m3/h
Nominal data
Nominal speed
Air flow
Type
Series 4600 TZ
Input power
Air flow
–
–
–
–
DC axial fans
– Material:
max.
206 m /h
AC axial fans
3
 127 x 38 mm
– Material:
–
–
–
–
Housing: Die-cast aluminium
Impeller: GRP1) (PA)
Direction of air flow: Exhaust over struts
Direction of rotation: Counter-clockwise, seen
on rotor
Connection:
Via 2 flat plugs 2,8 x 0,8 mm
grounding lug for M4 x 6
Mass:
570 g
– Possible special versions:
(See page 12)
- Humidity protection
Temperature range
Service life L10
at 40 °C
2 250
-30...+55
35 000 / 20 000
18,0
2 700
-20...+50
40 000 / 32 500
44
5,5
18,0
2 750
-30...+60
40 000 / 25 000
60
40
4,9
12,0
2 500
-30...+55
35 000 / 20 000
60
46
5,7
17,0
3 050
-20...+55
42 500 / 30 000
60
47
5,8
17,0
3 100
-30...+75
42 500 / 20 000
cfm
VAC
Hz
dB(A)
Bel(A)
150
88
230
50
37
180
106
230
50
43
5958
180
106
230
50
5938
162
95
115
5900
206
121
115
5908
206
121
115
Nominal data
Type
5988
5950
Subject to alterations
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
214
Guard grilles
from p. 242
Connection cables
p. 255
Curve
Nominal speed
13,0
5,4
m3/h
Series 5900
at T max
Input power
4,9
Sound power level
Hours
Sound pressure level
°C
Frequency
rpm
Nominal voltage
Watts
Air flow
/
Air flow
Sintec sleeve bearings
Ball bearings
1) Fibreglass-reinforced plastic
Hours
➀
➂
➂
➁
➃
➃
Information
270 m /h
AC axial fans
3
 135 x 38 mm
DC axial fans
2 700
-35...+70
45 000 / 20 000
➀
6,2
26,0
3 100
-35...+80
47 500 / 20 000
➁
cfm
VAC
Hz
dB(A)
Bel(A)
5656 S
235
138
230
50
46
5606 S
270
159
115
60
50
DC fans - specials
m3/h
Nominal data
DC centrifugal fans
Service life L10
at 40 °C
30,0
Type
Series 5600
Curve
Temperature range
5,9
Sound power level
Hours
Sound pressure level
°C
Frequency
rpm
Nominal voltage
Watts
Air flow
/
Air flow
–
Nominal speed
–
– Possible special versions:
(See page 12)
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54
Input power
–
–
Housing: Die-cast aluminium
Impeller: Painted sheet steel
Direction of air flow: Exhaust over struts
Direction of rotation: Counter-clockwise, seen
on rotor
Connection:
Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4 x 8
Mass:
800 g
Sintec sleeve bearings
Ball bearings
– Material:
at T max
max.
Hours
Guard grilles
from p. 242
Connection cables
p. 255
215
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
Representatives
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
Subject to alterations
max.
380 m /h
AC axial fans
3
150 x 172 x 38 mm
2 800
-25...+55
60 000 / 32 000
➀
6,8
28,0
3 350
-25...+65
55 000 / 18 000
➁
m3/h
cfm
VAC
Hz
dB(A)
Bel(A)
7056 ES
320
188
230
50
51
7006 ES
380
224
115
60
56
Nominal data
Subject to alterations
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
216
Guard grilles
from p. 242
Connection cables
p. 255
Curve
Service life L10
at 40 °C
27,0
Type
Series 7000
at T max
Temperature range
6,4
Sound power level
Hours
Sound pressure level
°C
Frequency
rpm
Nominal voltage
Watts
Air flow
/
Air flow
–
–
Nominal speed
–
Input power
–
–
Housing: Die-cast aluminium
Impeller: Painted sheet steel
Direction of air flow: Exhaust over struts
Direction of rotation: Counter-clockwise, seen
on rotor
Connection:
Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4 x 8
Mass:
900 g
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency.
See page 194, 196, 198.
Sintec sleeve bearings
Ball bearings
– Material:
Hours
380 m /h
Information
max.
AC axial fans
3
Ø 150 x 55 mm
DC centrifugal fans
-25...+50
60 000 / 47 500
2 800
-25...+70
60 000 / 30 000
53
6,4
38,0
3 250
-25...+70
60 000 / 47 500
53
6,4
38,0
3 250
-25...+90
60 000 / 15 000
VAC
Hz
dB(A)
Bel(A)
7855 ES
325
191
230
50
49
7856 ES
325
191
230
50
49
7805 ES
380
224
115
60
7806 ES
380
224
115
60
Hours
➀
➀
➁
➁
ACmaxx / EC fans
cfm
DC fans - specials
Service life L10
at 40 °C
2 800
45,0
m3/h
Guard grilles
from p. 242
tin-pla
ted
217
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
AC centrifugal fans
AC axial fans
Subject to alterations
Representatives
Nominal data
Curve
Temperature range
45,0
6,0
Type
Series 7800
at T max
Nominal speed
6,0
Sound power level
Hours
Sound pressure level
°C
Frequency
rpm
Nominal voltage
Watts
Air flow
/
Air flow
–
–
Input power
–
Sintec sleeve bearings
Ball bearings
–
–
Housing: Die-cast aluminium
Impeller: Painted sheet steel
Direction of air flow: Exhaust over struts
Direction of rotation: Counter-clockwise, seen
on rotor
Connection:
Via 2 single wires, wire
ends with brass lead tips
grounding lug for M4 x 8
Mass:
1,1 kg
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 194.
DC axial fans
– Material:
max.
425 m /h
AC axial fans
3
Ø 150 x 55 mm
2 700
-25...+50
63 000 / 50 000
➀
6,9
46,0
3 050
-25...+70
50 000 / 24 000
➁
m3/h
cfm
VAC
Hz
dB(A)
Bel(A)
7450 ES
380
224
230
50
60
7400 ES
425
250
115
60
62
Nominal data
Subject to alterations
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
218
Guard grilles
from p. 242
tin-pla
ted
Curve
Service life L10
at 40 °C
47,0
Type
Series 7400
at T max
Temperature range
6,8
Sound power level
Hours
Sound pressure level
°C
Frequency
rpm
Nominal voltage
Watts
Air flow
/
Air flow
–
–
Nominal speed
–
Input power
–
–
Housing: Die-cast aluminium
Impeller: Painted sheet steel
Direction of air flow: Intake over struts
Direction of rotation: Counter-clockwise, seen
on rotor
Connection:
Via 2 single wires, wire
ends with brass lead tips
grounding lug for M4 x 8
Mass:
1,1 kg
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 194.
Sintec sleeve bearings
Ball bearings
– Material:
Hours
500 m /h
Information
max.
AC axial fans
3
Ø 172 x 51 mm
DC centrifugal fans
-25...+70
62 000 / 31 000
2 800
-25...+60
62 000 / 39 000
60
6,4
26,0
3 300
-25...+70
57 000 / 28 000
58
6,7
29,0
3 300
-25...+75
57 000 / 22 000
VAC
Hz
dB(A)
Bel(A)
6058 ES
375
221
230
50
55
6078 ES
420
247
230
50
54
6008 ES
440
259
115
60
6028 ES
500
284
115
60
Hours
➀
➁
➂
➃
ACmaxx / EC fans
cfm
DC fans - specials
Service life L10
at 40 °C
2 800
26,0
m3/h
Accessories
AC centrifugal fans
AC axial fans
Subject to alterations
Guard grilles
from p. 242
219
2016-01
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
Representatives
Nominal data
Curve
Temperature range
24,0
6,3
Type
Series 6000
at T max
Nominal speed
5,9
Sound power level
Hours
Sound pressure level
°C
Frequency
rpm
Nominal voltage
Watts
Air flow
/
Air flow
–
–
Input power
–
Sintec sleeve bearings
Ball bearings
–
–
Housing: Die-cast aluminium
Impeller: Painted sheet steel
Direction of air flow: Exhaust over struts
Direction of rotation: Counter-clockwise, seen
on rotor
Connection:
Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4 x 6
Mass:
1,0 kg
Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 196,198.
DC axial fans
– Material:
1 000 m /h
AC axial fans
3
 225 x 80 mm
– Material:
Max. back-pressure
Perm. amb. temp.
Mass
C
D
Sound power level
M2E 068-BF
B
Capacitor
W2E 200-HK38-01
A
Input current
M2E 068-BF
Input power
W2E 200-HK86-01
Speed / rpm
Motor
Air flow
Type
Frequency
Nominal data
Number of blades:
Direction of air flow:
Direction of rotation:
Degree of protection:
Insulation class:
Mounting position:
Condensate discharges:
Mode of operation:
Bearings:
Nominal voltage
Curve
–
–
–
–
–
–
–
–
–
Housing: Die-cast-aluminium
Impeller: Sheet steel, coated in black
Rotor: Coated in black
7
"V"
Counter-clockwise, seen on rotor
IP 44, depending on installation and position
"B"
Any
None
Continuous operation (S1)
Maintenance-free ball bearings
Electrical connection
max.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
kg
1~115
1~115
50
60
880
1 000
2 550
2 800
64
80
0,58
0,70
5,0/220
5,0/220
-----
80 -25...+60
95 -25...+65
2,0
2,0
p. 263 / A1)
1~230
1~230
50
60
880
1 000
2 550
2 800
64
80
0,29
0,35
1,5/450
1,5/450
-----
80
95
2,1
2,1
p. 263 / A1)
-25...+60
-25...+65
Pa
Curves:
in wg
Subject to alterations
n
rpm
Ped
W
I
A
L WA
dB(A)
B D
80
A C
0.2
60
40
20
Pfs
0
qv
100
200
200
300
400
400
600
500
800
cfm
m³/h
2016-01
Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise
levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment
conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have
to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions
220
A
1
2 640
56
0,56
---
A
2
2 595
58
0,57
---
A
3
2 550
61
0,58
---
A
4
2 480
64
0,60
---
B
1
2 980
67
0,58
---
B
2
2 880
71
0,62
---
B
3
2 790
75
0,65
---
B
4
2 660
80
0,69
---
C
1
2 630
60
0,30
---
C
2
2 585
64
0,31
---
C
3
2 530
66
0,31
---
B
4
2 480
69
0,32
---
D
1
3 000
70
0,31
---
D
2
2 935
73
0,32
---
D
3
2 850
77
0,34
---
D
4
2 705
83
0,36
---
0.4
100
Information
Motor protection:
Touch current:
Cable exit:
Electrical connection
Protection class:
Product conforming
to standards:
– Approvals:
TOP wired internally
< 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
Variabel
Via terminal strips (operating capacitor connected)
I (if customer has provided connection for protective earth)
DC axial fans
–
–
–
–
–
–
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
EN 60335-1, CE
A B EAC, UL 507, VDE, CSA C22.2 Nr. 113, CCC
C D EAC, UL 2111, VDE, CSA C22.2 Nr. 113, CCC
AC centrifugal fans
22
5
AC axial fans
"V" ›
N
N L
Ø4.5 +0.2
(8x)
Accessories
PE
L
Connection cables
p. 263
7
80 ±0.3
221
Representatives
Guard grilles
p. 245
7
2016-01
Ø240
Ø260
1 880 m /h
AC axial fans
3
 225 x 80 mm
– Material:
Max. back-pressure
Perm. amb. temp.
Mass
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
kg
1~115
1~115
50
60
1 740
1 880
2 375
2 350
125
165
1,10
1,45
12/320
12/320
70
72
100 -25...+50
110 -25...+45
2,7
2,7
p. 263 / A3)
1~230
1~230
50
60
1 695
1 840
2 320
2 300
125
160
0,55
0,71
3,0/400
3,0/400
70
71
100
110
2,7
2,7
p. 263 / A3)
Pa
100
B D
A C
0.3
80
0.2
60
0.1
40
20
Pfs
0
qv
200
400
400
600
800
800
1200
1000
1600
cfm
m³/h
2016-01
Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise
levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment
conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have
to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions
n
rpm
Ped
W
I
A
L WA
dB(A)
A
1
2 580
108
0,96
70
A
2
2 510
115
1,02
69
A
3
2 455
121
1,06
68
A
4
2 375
125
1,10
68
B
1
2 785
149
1,30
72
B
2
2 655
154
1,35
70
B
3
2 490
162
1,41
70
B
4
2 350
165
1,45
70
C
1
2 550
101
0,44
70
C
2
2 480
109
0,47
69
C
3
2 410
115
0,50
68
B
4
2 320
125
0,55
68
D
1
2 750
134
0,59
71
D
2
2 600
145
0,63
70
D
3
2 420
152
0,66
69
D
4
2 300
160
0,71
70
0.4
Curves:
222
-25...+60
-25...+50
(1) Nominal data in operating point with maximum load and 115/230 VAC
in wg
Subject to alterations
C
D
Sound power level
M2E 068-CF
B
Capacitor
W2E 250-HP06-01
A
Max. Input current(1)
M2E 068-CF
Max. Input power(1)
W2E 250-HP08-01
Speed / rpm(1)
Motor
Air flow
Type
Frequency
Nominal data
Number of blades:
Direction of air flow:
Direction of rotation:
Degree of protection:
Insulation class:
Mounting position:
Condensate discharges:
Mode of operation:
Bearings:
Nominal voltage
Curve
–
–
–
–
–
–
–
–
–
Housing: Die-cast-aluminium
Impeller: Plastic PP
Rotor: Coated in black
7
"V"
Counter-clockwise, seen on rotor
IP 44, depending on installation and position
"F"
Any
None
Continuous operation (S1)
Maintenance-free ball bearings
Electrical connection
max.
Information
TOP wired internally
< 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
Variabel
Via terminal strips (operating capacitor connected)
I (if customer has provided connection for protective earth)
DC axial fans
Motor protection:
Touch current:
Cable exit:
Electrical connection
Protection class:
Product conforming
to standards:
– Approvals:
EN 60335-1, CE
A B UL 2111, CSA C22.2 Nr. 77
C D EAC, UL 2111, CSA C22.2 Nr. 77
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
–
–
–
–
–
–
4x90°
15°
20°
"V" ›
4x9
0°
(8x)
90
AC axial fans
Ø2
N L
"V" ›
W2E 250-HP06-01
7
0
90
Ø2
+0.2
Ø4.4
80±0.5
28
7
AC centrifugal fans
Ø5.4+0.25
PE
28
0
(8x)
Ø295
Ø320
N L
Guard grilles
p. 245
Connection cables
p. 263
7
7
80±0.5
223
2016-01
Ø295
Ø320
Representatives
Ø5.4+0.25 (8x)
PE
Accessories
4x90°
4x90°
20°
W2E 250-HP08-01
15°
+0.2
Ø4.4
max.
850 m /h
AC diagonal module
3
Ø 200 mm
Max. back-pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
1~ 115
1~ 115
50
60
760
830
2 650
2 910
64
88
0,56
0,77
6,0/250
6,0/250
70
72
200
240
Electrical connection
Sound power level
B
Capacitor
A
Input current
M2E 068-CF
Input power
K2E 200-AA12 -01
Speed / rpm
Motor
Air flow
Type
Frequency
Nominal data
Number of blades:
Direction of air flow:
Direction of rotation:
Degree of protection:
Insulation class:
Mounting position:
Condensate discharges:
Mode of operation:
Bearings:
Nominal voltage
Curve
–
–
–
–
–
–
–
–
–
Housing: Plastic PA
Support bracket: Plastic PA
Impeller: Plastic PA
Rotor: Coated in black
7
"V"
Clockwise, seen on rotor
IP 44, depending on installation and position
"F"
Any
None
Continuous operation (S1)
Maintenance-free ball bearings
Mass
– Material:
kg
-25..+65 2,1
-25..+65 2,1
p. 263 / A1)
Subject to alterations
n
rpm
Curves:
50 Hz
B
60 Hz
2016-01
224
I
A
L WA
dB(A)
A
1
2 650
64
0,56
70
A
2
2610
67
0,59
68
A
3
2 580
70
0,61
67
A
4
2 590
69
0,61
69
B
1
2 910
88
0,77
72
B
2
2 815
93
0,81
69
B
3
2 755
96
0,84
69
B
4
2 780
95
0,83
71
A
Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
Ped
W
Information
DC axial fans
TOP wired internally
< 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
Lateral
Via connector
I (if customer has provided connection for protective earth)
EN 60335-1, CE
UL 2111, CSA C22.2 Nr. 77
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
Motor protection:
Touch current:
Cable exit:
Electrical connection
Protection class:
Product conforming
to standards:
– Approvals:
AC axial fans
X
Electrical connections
p. 263
View X
1
2
3
Accessories
1 = not used
2 = N + condensator
3=L
4 = PE
4
225
Representatives
Coded plug system
Universal-Mate-N-Lok
Connector shell: AMP 350 780-1
3 x Pin connector: AMP 926 885-1
Mating connector (not part of
delivery):
Connector shell: AMP 350 779-4
3 x female terminal: AMP 926 884-1
AC centrifugal fans
Mounting dimensions
2016-01
–
–
–
–
–
–
max.
850 m /h
AC diagonal module
3
Ø 200 mm
Max. back-pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
1~ 230
1~ 230
50
60
765
845
2 650
2 950
65
90
0,30
0,40
2,0/400
2,0/400
70
73
200
245
Electrical connection
Sound power level
B
Capacitor
A
Input current
M2E 068-CF
Input power
K2E 200-AA52 -02
Speed / rpm
Motor
Air flow
Type
Frequency
Nominal data
Number of blades:
Direction of air flow:
Direction of rotation:
Degree of protection:
Insulation class:
Mounting position:
Condensate discharges:
Mode of operation:
Bearings:
Nominal voltage
Curve
–
–
–
–
–
–
–
–
–
Housing: Plastic PA
Support bracket: Plastic PA
Impeller: Plastic PA
Rotor: Coated in black
7
"V"
Clockwise, seen on rotor
IP 44, depending on installation and position
"F"
Any
None
Continuous operation (S1)
Maintenance-free ball bearings
Mass
– Material:
kg
-25..+80 2,1
-25..+80 2,1
p. 263 / A1)
Subject to alterations
n
rpm
Curves:
50 Hz
B
60 Hz
2016-01
226
I
A
L WA
dB(A)
A
1
2 650
65
0,30
70
A
2
2 620
67
0,30
68
A
3
2 605
68
0,30
67
A
4
2 610
68
0,30
69
B
1
2 950
90
0,40
73
B
2
2 865
93
0,41
70
B
3
2 820
96
0,42
69
B
4
2 840
94
0,41
71
A
Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
Ped
W
Information
DC axial fans
TOP wired internally
< 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
Lateral
Via connector
I (if customer has provided connection for protective earth)
EN 60335-1, CE
UL 2111, CSA C22.2 Nr. 77
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
Motor protection:
Touch current:
Cable exit:
Electrical connection
Protection class:
Product conforming
to standards:
– Approvals:
AC axial fans
X
Electrical connections
p. 263
View X
1
2
3
Accessories
1 = not used
2 = N + condensator
3=L
4 = PE
4
227
Representatives
Coded plug system
Universal-Mate-N-Lok
Connector shell: AMP 350 780-1
3 x Pin connector: AMP 926 885-1
Mating connector (not part of
delivery):
Connector shell: AMP 350 779-4
3 x female terminal: AMP 926 884-1
AC centrifugal fans
Mounting dimensions
2016-01
–
–
–
–
–
–
max.
880 m /h
AC diagonal module
3
Ø 200 mm
Max. back-pressure
Perm. amb. temp.
VAC
Hz
m3/h
rpm
W
A
µF/VDB
dB(A)
Pa
°C
3~ 400 Y
3~ 400 Y
50
60
780
880
2 700
3 050
65
90
0,15
0,16
-----
71
73
210
260
Electrical connection
Sound power level
B
Capacitor
A
Input current
M2D 068-CF
Input power
K2D 200-AA02 -02
Speed / rpm
Motor
Air flow
Type
Frequency
Nominal data
Number of blades:
Direction of air flow:
Direction of rotation:
Degree of protection:
Insulation class:
Mounting position:
Condensate discharges:
Mode of operation:
Bearings:
Nominal voltage
Curve
–
–
–
–
–
–
–
–
–
Housing: Plastic PA
Support bracket: Plastic PA
Impeller: Plastic PA
Rotor: Coated in black
7
"V"
Clockwise, seen on rotor
IP 44, depending on installation and position
"F"
Any
None
Continuous operation (S1)
Maintenance-free ball bearings
Mass
– Material:
kg
-25..+75 2,0
-25..+75 2,0
p. 263 / C2)
Subject to alterations
n
rpm
Curves:
Ped
W
I
A
L WA
dB(A)
B
50 Hz
60 Hz
A
2016-01
Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
228
A
1
2 700
65
0,15
71
A
2
2 695
69
0,16
69
A
3
2 675
71
0,16
68
A
4
2 680
70
0,16
69
B
1
3 050
90
0,16
73
B
2
3 010
94
0,16
71
B
3
2 970
98
0,17
70
B
4
2 975
96
0,17
72
Information
DC axial fans
TOP wired internally
< 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
Lateral
Via connector
I (if customer has provided connection for protective earth)
EN 60335-1, CE
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
Motor protection:
Touch current:
Cable exit:
Electrical connection
Protection class:
Product conforming
to standards:
AC axial fans
X
Electrical connections
p. 263
View X
1
2
3
Accessories
1 = L3
2 = L1
3 = L2
4 = PE
4
229
Representatives
Coded plug system
Universal-Mate-N-Lok
Connector shell: AMP 350 780-1
3 x Pin connector: AMP 926 885-1
Mating connector (not part of
delivery):
Connector shell: AMP 350 779-4
3 x female terminal: AMP 926 884-1
AC centrifugal fans
Mounting dimensions
2016-01
–
–
–
–
–
–
2016-01
230