203 Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans AC axial fan overview AC axial fans 2016-01 DC axial fans Information AC axial fans 205 206 AC axial fans Technical information Product line Bearings The renowned ebm-papst AC fans are used when DC voltage is not AC fans with sleeve bearings are powered by Class E insulated motors. available. The AC range of fans is based on experience gained from Fans with ball bearings are equipped with Class B, E or F insulated decades of development activity, millions of units in series production motors. and competence in innovation of a world-wide technological leader. Degree of protection A wide range of fans for AC operation is presented in this catalogue. In All fans are equipped with degree of protection IP 20 as standard. addition to complete device fans, you will also find fans without external IP 54 / IP 68 and further degrees of protection are available on request. housing, providing a particularly economical advantage when the air duct can be integrated in the respective device. AC voltage The line of AC fans for Euro voltage according Variety of sizes to IEC 60038 (230 V + 6 %, -10 %) is basically also available for 115 V. AC fans are available in a variety of sizes with either air exhaust or air intake over struts. Silent running models with sleeve bearings. Frequencies Electrical connection with plug connection or external leads are available. AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their technical data then changes accordingly. Shaded-pole or capacitor motors Fan drives by shaded-pole or capacitor motors, most of which incorporate Capacitor the world-famous ebm-papst external rotor principle: The fan blades are Fans driven by capacitor external motors directly attached to the external rotor of the external rotor motor, thus provide particularly high operating efficiency. Generally, the required combining both high performance and profitability. operating capacitor is already integrated in the fan housing. Flat built AC fans Overloading ebm-papst also has particularly flat built AC fans with internal rotor motor. Almost all AC fans are protected against overloading (e.g. due to locked Their advantage: quick start to full speed. A plastic impeller and the both rotor) the drive motors are either impedance protected (marked smaller and lighter internal rotor motor lead to a lower moment of inertia. “Impedance protected”, and/or “Z.P.”) or are equipped with a thermal switch (marked “Thermally protected” or “Th.P.”). The model designation 2016-01 of these fans ends with “S”. 204 Information DC axial fans Axial fans for AC operation Page Air flow 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 3000 c 80 x 38 8000 N 30...61 Ø 76 x 37 8000 TV 24...47 207 92 x 25 3900 31...70 208 92 x 38 3000 49...89 209 9900 84...135 210 4000 N 80...180 211 212 c c 119 x 25 c 119 x 38 c 119 x 38 Ø 108 x 37 c 127 x 38 c 135 x 38 4000 Z 100...180 4600 TZ 125...140 5900 150...206 206 213 129 214 5600 235...270 215 150 x 172 x 38 7000 320...380 216 Ø 150 x 55 7800 325...380 217 Ø 150 x 55 7400 380...425 218 Ø 172 x 51 6000 375...500 219 W2E 200 880...1030 220 W2E 250 1865 222 c 225 x 80 c 280 x 80 Ø 200 K2E 200 765...840 224 Ø 200 K2E 200 765...850 226 Ø 200 K2D 200 780...880 228 DC fans - specials c DC centrifugal fans 10 m3/h mm ACmaxx / EC fans Series Dimension Overview of air performance Subject to alterations tion Salt Page • • • • 206 – – – 208 • • • 209 – – – 210 • • • • • • • • • 211 – – – 214 Axial fan OPTIONAL p. 5600 ja – • • • • • • • • • • • – • 215 150 x 172 x 38 7000 ja – – – – – 216 Ø 150 x 55 7800 ja • – – – – 217 Ø 150 x 55 7400 ja – – – – – 218 Ø 172 x 51 6000 ja – – – – – 219 Ø 76 x 37 c 92 x 25 c 92 x 38 c 119 x 25 c 119 x 38 c 119 x 38 Ø 108 x 37 c 127 x 38 c 135 x 38 8000 N ja / – 8000 TV ja / – 3900 ja / – 3000 ja / – 9900 ja / – 4000 N ja / 4000 Z ja / • • 4600 TZ ja / – 5900 ja / – 207 AC centrifugal fans Series c 80 x 38 212 213 Accessories mm Subject to alterations – not yet available Sleeve bearings Ball bearings 205 2016-01 • available Representatives fog p IP 68 • • AC axial fans rotec ectio prot = 54 IP > nal idity d sig Hum Spee Sinte c ball sleeve b bear earing ings s/ Dim VDE , ensio UL, C n SA n Overview of technically feasible designs 61 m /h AC axial fans 3 80 x 38 mm – Material: – – – Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours 8880 N 30 17,7 230 50 18 3,3 9,0 1 750 -10...+80 60 000 / 25 000 8850 N 37 21,8 230 50 24 3,9 12,5 2 150 -10...+70 52 500 / 25 000 8550 N 50 29,4 230 50 30 4,4 12,0 2 700 -10...+70 52 500 / 25 000 8556 N 50 29,4 230 50 31 4,5 12,0 2 800 -40...+90 52 500 / 15 000 8830 N 36 21,2 115 60 21 3,7 8,0 1 950 -10...+80 62 500 / 25 000 8800 N 47 27,7 115 60 28 4,3 11,0 2 500 -10...+70 55 000 / 27 500 8500 N 61 35,9 115 60 34 4,8 11,0 3 200 -10...+75 55 000 / 25 000 8506 N 61 35,9 115 60 35 5,0 11,0 3 300 -40...+95 55 000 / 15 000 Series 8000 N Nominal data Type at T max Air flow – Possible special versions: (See page 12) - Humidity protection - Salt fog protection - Degree of protection: IP 54 / IP 68 Air flow – – Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via 2 single wires grounding lug for M4 x 8 Mass: 490 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 188. Hours Subject to alterations Fan type 8880 N 8830 N 8556 N 8506 N 8800 N 8550 N 8500 N 8850 N 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 206 Guard grilles from p. 242 tin-pla ted Curve max. Length “L” Lead wires 310 mm long AWG 18, TR 64 310 mm long AWG 22 440 mm long AWG 18, TR 64 ➀ ➁ ➂ ➂ ➃ ➄ ➅ ➅ 47 m /h Information max. AC axial fans 3 Ø 76 x 37 mm – Possible special versions: Impeller: Die-cast aluminium (See page 12) Mounting bracket: Metal - Humidity protection Direction of air flow: Exhaust over mounting bracket - Salt fog protection Direction of rotation: Clockwise, seen on rotor - Degree of protection: IP 54 / IP 68 Connection: Via 2 single wires Mass: 370 g Temperature range Service life L10 at 40 °C 9,0 1 650 -10...+80 60 000 / 25 000 20 12,0 2 100 -10...+70 52 500 / 25 000 50 27 12,0 2 650 -10...+70 52 500 / 25 000 50 28 12,0 2 750 -40...+90 52 500 / 15 000 115 60 18 8,0 1 850 -10...+80 62 500 / 25 000 21,2 115 60 24 11,0 2 450 -10...+70 55 000 / 27 500 27,7 115 60 32 11,0 3 150 -10...+75 55 000 / 25 000 27,7 115 60 33 11,0 3 250 -40...+95 55 000 / 15 000 dB(A) 8880 TV 24 14,1 230 50 8850 TV 31 18,2 230 50 8550 TV 40 23,5 230 8556 TV 40 23,5 230 8830 TV 27 15,9 8800 TV 36 8500 TV 47 8506 TV 47 DC fans - specials Hz Hours ACmaxx / EC fans VAC Type Subject to alterations Lead wires 325 mm long AWG 18, TR 64 8506 TV 325 mm long AWG 18 3 37 +1 AC centrifugal fans AWG 18, TR 64 8500 TV 3,7 + 0,15 325 mm long 10 R4 101 + 0,2 0,3 tin-plated 90° 207 2016-01 8556 TV 8800 TV ø75,8 8550 TV 8830 TV 6 +1 8850 TV AC axial fans Length “L” 8880 TV Accessories Fan type 325 +10 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 76.5 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 8000 N is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. Representatives cfm Nominal data DC centrifugal fans Nominal speed 15 m3/h Series 8000 TV at T max Input power Hours Sound pressure level °C Frequency rpm Nominal voltage Watts Air flow / Air flow Sintec sleeve bearings Ball bearings – – – – DC axial fans – Material: 70 m /h AC axial fans 3 92 x 25 mm – Material: – – – Nominal speed Temperature range Service life L10 at 40 °C 1 550 -10...+80 70 000 / 27 500 6,0 1 550 -40...+80 70 000 / 27 500 29 4,2 6,0 2 150 -10...+80 70 000 / 27 500 29 4,2 6,0 2 150 -40...+80 70 000 / 27 500 50 35 4,7 11,0 2 650 -20...+80 55 000 / 20 000 230 50 35 4,7 11,0 2 650 -40...+80 55 000 / 20 000 23,0 115 60 27 4,0 5,0 1 850 -10...+80 70 000 / 27 500 23,0 115 60 27 4,0 5,0 1 850 -40...+80 70 000 / 27 500 53 31,2 115 60 34 4,6 5,0 2 600 -10...+80 70 000 / 27 500 53 31,2 115 60 34 4,6 5,0 2 600 -40...+80 70 000 / 27 500 3900 70 41,2 115 60 40 5,1 9,0 3 150 -20...+80 60 000 / 22 500 3906 70 41,2 115 60 40 5,1 9,0 3 150 -40...+80 60 000 / 22 500 cfm VAC Hz dB(A) Bel(A) 3950 L 31 18,2 230 50 24 3956 L 31 18,2 230 50 24 3950 M 45 26,5 230 50 3956 M 45 26,5 230 50 3950 59 34,7 230 3956 59 34,7 3900 L 39 3906 L 39 3900 M 3906 M Nominal data Type Subject to alterations Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 208 Guard grilles from p. 242 Connection cables p. 255 at T max Input power 6,0 3,8 Sound power level 3,8 Sound pressure level Hours Frequency °C Nominal voltage rpm Air flow Watts Air flow / m3/h Series 3900 2016-01 – Possible special versions: (See page 12) - Humidity protection Sintec sleeve bearings Ball bearings – – Housing: Die-cast aluminium Impeller: Mineral-reinforced plastic PA Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 flat plugs 2,8 x 0,5 mm grounding lug for M4 Mass: 280 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 189. Curve max. Hours ➀ ➀ ➁ ➁ ➂ ➂ ➃ ➃ ➄ ➄ ➅ ➅ Information AC axial fans 3 92 x 38 mm Service life L10 at 40 °C DC centrifugal fans Temperature range 1 750 -10...+75 60 000 / 27 500 9,0 1 950 -40...+90 60 000 / 20 000 32 4,4 8,5 2 300 -10...+80 60 000 / 25 000 33 4,5 8,5 2 400 -40...+90 60 000 / 20 000 50 36 4,8 12,0 2 650 -10...+55 52 500 / 37 500 230 50 37 4,9 12,0 2 700 -40...+75 52 500 / 22 500 31,8 115 60 26 3,9 8,0 1 900 -10...+80 62 500 / 25 000 35,3 115 60 29 4,2 8,0 2 150 -40...+95 62 500 / 17 500 73 43,0 115 60 35 4,6 8,0 2 500 -10...+80 62 500 / 25 000 73 43,0 115 60 36 4,7 8,0 2 600 -40...+95 62 500 / 17 500 3600 89 52,4 115 60 41 5,1 11,0 3 100 -10...+65 55 000 / 30 000 3606 89 52,4 115 60 42 5,2 11,0 3 200 -40...+75 55 000 / 25 000 m3/h cfm VAC Hz dB(A) Bel(A) 3850 49 28,8 230 50 24 3856 54 31,8 230 50 26 3550 67 39,4 230 50 3556 67 39,4 230 50 3650 75 44,1 230 3656 75 44,1 3800 54 3806 60 3500 3506 Hours ➀ ➁ ➂ ➂ ➃ ➃ ➄ ➅ ➆ ➆ ➇ ➇ Subject to alterations Length “L” With sleeve bearings 310 mm long Lead wires AWG 18, TR 64 With ball bearings 310 mm long AWG 18 Guard grilles from p. 242 tin-pla ted 209 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans Fan type Representatives Nominal data DC fans - specials Nominal speed 9,0 3,9 Type Series 3000 at T max Input power 3,7 Sound power level Hours Sound pressure level °C Frequency rpm Nominal voltage Watts Air flow / Air flow Sintec sleeve bearings Ball bearings – – – Possible special versions: (See page 12) - Humidity protection - Salt fog protection - Degree of protection: IP 54 / IP 68 ACmaxx / EC fans – – – Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via 2 single wires grounding lug for M4 x 8 Mass: 420 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 189. AC axial fans – Material: DC axial fans 89 m /h Curve max. 135 m /h AC axial fans 3 119 x 25 mm – Material: – – – Nominal voltage Frequency Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L10 at 40 °C cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours 9956 L 84 49,4 230 50 29 4,4 9,5 1 850 -40...+80 57 500 / 22 500 9956 M 104 61,2 230 50 35 4,7 10,0 2 250 -40...+80 57 500 / 22 500 9950 117 68,9 230 50 37 5,0 14,0 2 450 -20...+70 47 500 / 22 500 9956 117 68,9 230 50 37 5,0 14,0 2 450 -40...+70 47 500 / 22 500 9906 L 100 58,9 115 60 34 4,6 8,0 2 100 -40...+80 62 500 / 25 000 Nominal data Type at T max Air flow m3/h Series 9900 Hours 9906 M 111 65,3 115 60 37 5,0 8,0 2 450 -40...+80 62 500 / 25 000 9900 135 79,5 115 60 42 5,4 12,0 2 850 -20...+70 52 500 / 25 000 9906 135 79,5 115 60 42 5,4 12,0 2 850 -40...+70 52 500 / 25 000 Subject to alterations Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 2016-01 – Possible special versions: (See page 12) - Humidity protection Air flow – – Housing: Die-cast aluminium Impeller: Mineral-reinforced plastic PA Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 flat plugs 2,8 x 0,5 mm grounding lug for M4 Mass: 320 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 192. 210 Guard grilles from p. 242 Connection cables p. 255 Curve max. ➀ ➁ ➂ ➂ ➃ ➄ ➅ ➅ Information 119 x 38 mm Nominal speed Temperature range Service life L10 at 40 °C 11,0 1 550 -10...+70 55 000 / 27 500 4,4 10,0 1 800 -10...+70 57 500 / 27 500 41 5,2 18,0 2 350 -10...+55 40 000 / 27 500 44 5,4 16,5 2 550 -10...+55 42 500 / 30 000 50 46 5,4 19,0 2 650 -10...+55 37 500 / 27 500 230 50 47 5,5 19,0 2 650 -40...+85 37 500 / 15 000 50 115 60 26 4,1 10,0 1 650 -10...+75 57 500 / 25 000 57 115 60 32 4,3 9,0 1 750 -10...+75 60 000 / 27 500 151 89 115 60 45 5,4 16,0 2 700 -10...+65 42 500 / 25 000 169 100 115 60 48 5,7 15,0 3 000 -10...+65 47 500 / 25 000 4600 N 180 106 115 60 50 5,7 18,0 3 100 -10...+60 40 000 / 25 000 4606 N 180 106 115 60 51 5,8 18,0 3 100 -40...+90 40 000 / 15 000 m3/h cfm VAC Hz dB(A) Bel(A) 4890 N 80 47 230 50 25 4850 N* 100 59 230 50 32 4580 N* 123 72 230 50 4550 N* 145 85 230 50 4650 N 160 94 230 4656 N 160 94 4840 N 85 4800 N* 97 4530 N* 4500 N* Series 4000 N Type Hours ➀ ➁ ➂ ➃ ➄ ➄ ➅ ➆ ➇ ➈ ➉ ➉ Subject to alterations Accessories AC centrifugal fans * Fan with 3 blades. Guard grilles from p. 242 Connection cables p. 255 211 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions Representatives Nominal data at T max Input power 4,0 Sound power level Hours Sound pressure level °C Frequency rpm Nominal voltage Watts Air flow / Air flow Sintec sleeve bearings Ball bearings – – – Possible special versions: (See page 12) - Speed signal - Humidity protection - Salt fog protection - Degree of protection: IP 54 / IP 68 DC fans - specials – – – Optionally available: Variants with strengthened mounting flanges and customizable single strands ACmaxx / EC fans – Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Intake over struts Types 4890 N and 4840 N exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via 2 flat plugs 2,8 x 0,5 mm grounding lug for M4 Mass: 550 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 192. AC axial fans – Material: DC axial fans AC axial fans 3 DC centrifugal fans 180 m /h Curve max. 180 m /h AC axial fans 3 119 x 38 mm – Material: – – – Nominal speed Temperature range Service life L10 at 40 °C 1 700 -10...+65 50 000 / 27 500 13,0 1 700 -40...+75 50 000 / 20 000 30 4,3 13,0 1 900 -10...+65 50 000 / 27 500 30 4,3 13,0 1 900 -40...+75 50 000 / 20 000 50 40 5,3 19,0 2 650 -10...+50 37 500 / 30 000 230 50 40 5,3 19,0 2 650 -40...+75 37 500 / 17 500 62 115 60 28 4,1 12,0 1 800 -10...+70 52 500 / 25 000 62 115 60 28 4,1 12,0 1 800 -40...+75 52 500 / 17 500 120 71 115 60 32 4,4 12,0 2 000 -10...+70 52 500 / 25 000 120 71 115 60 32 4,4 12,0 2 000 -40...+75 52 500 / 17 500 4600 Z 180 106 115 60 45 5,6 18,0 3 100 -10...+60 40 000 / 25 000 4606 Z 180 106 115 60 45 5,6 18,0 3 100 -40...+85 40 000 / 15 000 cfm VAC Hz dB(A) Bel(A) 100 59 230 50 26 100 59 230 50 26 4580 Z 115 68 230 50 4586 Z 115 68 230 50 4650 Z 160 94 230 4656 Z 160 94 4800 Z 105 4806 Z 105 4530 Z 4536 Z Nominal data Type 4850 Z 4856 Z Subject to alterations Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 212 Guard grilles from p. 242 Connection cables p. 255 at T max Input power 13,0 4,0 Sound power level 4,0 Sound pressure level Hours Frequency °C Nominal voltage rpm Air flow Watts Air flow / m3/h Series 4000 Z 2016-01 – Possible special versions: (See page 12) - Speed signal - Humidity protection - Salt fog protection - Degree of protection: IP 54 / IP 68 Sintec sleeve bearings Ball bearings – – Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via 2 flat plugs 2,8 x 0,5 mm grounding lug for M4 x 8 Mass: 540 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 192. Curve max. Hours ➀ ➀ ➁ ➁ ➂ ➂ ➃ ➃ ➄ ➄ ➅ ➅ 140 m /h Information max. AC axial fans 3 Ø 108 x 37 mm – Possible special versions: Impeller: Die-cast aluminium (See page 12) Mounting bracket: Metal - Humidity protection Direction of air flow: Exhaust over mounting bracket - Salt fog protection Direction of rotation: Clockwise, seen on rotor - Degree of protection: IP 54 / IP 68 Connection: Via 2 single wires Mass: 430 g 4650 TZ 125 73,6 230 50 42 4656 TZ 125 73,6 230 50 42 4600 TZ 140 82,4 115 60 4606 TZ 140 82,4 115 60 DC centrifugal fans / rpm °C Hours 19,0 2 600 -10...+50 37 500 / 30 000 19,0 2 600 -40...+65 37 500 / 20 000 45 18,0 2 950 -10...+50 40 000 / 32 500 45 18,0 2 950 -40...+75 40 000 / 17 500 at T max Watts DC fans - specials dB(A) Hours ACmaxx / EC fans Sintec sleeve bearings Ball bearings Hz Subject to alterations Fan type Lead wires 4650 TZ 4600 TZ AWG 22, TR 32 4656 TZ 4606 TZ AWG 18 AC centrifugal fans 37 + 1 3 Accessories 0,5 + 0,3 375 +10 6 +1 148,2 + 0,2 ø108 + 0,3 R4 16 4,3 + 0,15 AC axial fans The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 109 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 4000 Z is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. tin-plated 213 2016-01 90° Representatives Sound pressure level VAC Service life L10 at 40 °C Frequency cfm Temperature range Nominal voltage m3/h Nominal data Nominal speed Air flow Type Series 4600 TZ Input power Air flow – – – – DC axial fans – Material: max. 206 m /h AC axial fans 3 127 x 38 mm – Material: – – – – Housing: Die-cast aluminium Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 flat plugs 2,8 x 0,8 mm grounding lug for M4 x 6 Mass: 570 g – Possible special versions: (See page 12) - Humidity protection Temperature range Service life L10 at 40 °C 2 250 -30...+55 35 000 / 20 000 18,0 2 700 -20...+50 40 000 / 32 500 44 5,5 18,0 2 750 -30...+60 40 000 / 25 000 60 40 4,9 12,0 2 500 -30...+55 35 000 / 20 000 60 46 5,7 17,0 3 050 -20...+55 42 500 / 30 000 60 47 5,8 17,0 3 100 -30...+75 42 500 / 20 000 cfm VAC Hz dB(A) Bel(A) 150 88 230 50 37 180 106 230 50 43 5958 180 106 230 50 5938 162 95 115 5900 206 121 115 5908 206 121 115 Nominal data Type 5988 5950 Subject to alterations 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 214 Guard grilles from p. 242 Connection cables p. 255 Curve Nominal speed 13,0 5,4 m3/h Series 5900 at T max Input power 4,9 Sound power level Hours Sound pressure level °C Frequency rpm Nominal voltage Watts Air flow / Air flow Sintec sleeve bearings Ball bearings 1) Fibreglass-reinforced plastic Hours ➀ ➂ ➂ ➁ ➃ ➃ Information 270 m /h AC axial fans 3 135 x 38 mm DC axial fans 2 700 -35...+70 45 000 / 20 000 ➀ 6,2 26,0 3 100 -35...+80 47 500 / 20 000 ➁ cfm VAC Hz dB(A) Bel(A) 5656 S 235 138 230 50 46 5606 S 270 159 115 60 50 DC fans - specials m3/h Nominal data DC centrifugal fans Service life L10 at 40 °C 30,0 Type Series 5600 Curve Temperature range 5,9 Sound power level Hours Sound pressure level °C Frequency rpm Nominal voltage Watts Air flow / Air flow – Nominal speed – – Possible special versions: (See page 12) - Humidity protection - Salt fog protection - Degree of protection: IP 54 Input power – – Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 flat plugs 2,8 x 0,5 mm grounding lug for M4 x 8 Mass: 800 g Sintec sleeve bearings Ball bearings – Material: at T max max. Hours Guard grilles from p. 242 Connection cables p. 255 215 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans Subject to alterations max. 380 m /h AC axial fans 3 150 x 172 x 38 mm 2 800 -25...+55 60 000 / 32 000 ➀ 6,8 28,0 3 350 -25...+65 55 000 / 18 000 ➁ m3/h cfm VAC Hz dB(A) Bel(A) 7056 ES 320 188 230 50 51 7006 ES 380 224 115 60 56 Nominal data Subject to alterations 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 216 Guard grilles from p. 242 Connection cables p. 255 Curve Service life L10 at 40 °C 27,0 Type Series 7000 at T max Temperature range 6,4 Sound power level Hours Sound pressure level °C Frequency rpm Nominal voltage Watts Air flow / Air flow – – Nominal speed – Input power – – Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 flat plugs 2,8 x 0,5 mm grounding lug for M4 x 8 Mass: 900 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 194, 196, 198. Sintec sleeve bearings Ball bearings – Material: Hours 380 m /h Information max. AC axial fans 3 Ø 150 x 55 mm DC centrifugal fans -25...+50 60 000 / 47 500 2 800 -25...+70 60 000 / 30 000 53 6,4 38,0 3 250 -25...+70 60 000 / 47 500 53 6,4 38,0 3 250 -25...+90 60 000 / 15 000 VAC Hz dB(A) Bel(A) 7855 ES 325 191 230 50 49 7856 ES 325 191 230 50 49 7805 ES 380 224 115 60 7806 ES 380 224 115 60 Hours ➀ ➀ ➁ ➁ ACmaxx / EC fans cfm DC fans - specials Service life L10 at 40 °C 2 800 45,0 m3/h Guard grilles from p. 242 tin-pla ted 217 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans Subject to alterations Representatives Nominal data Curve Temperature range 45,0 6,0 Type Series 7800 at T max Nominal speed 6,0 Sound power level Hours Sound pressure level °C Frequency rpm Nominal voltage Watts Air flow / Air flow – – Input power – Sintec sleeve bearings Ball bearings – – Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 single wires, wire ends with brass lead tips grounding lug for M4 x 8 Mass: 1,1 kg Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 194. DC axial fans – Material: max. 425 m /h AC axial fans 3 Ø 150 x 55 mm 2 700 -25...+50 63 000 / 50 000 ➀ 6,9 46,0 3 050 -25...+70 50 000 / 24 000 ➁ m3/h cfm VAC Hz dB(A) Bel(A) 7450 ES 380 224 230 50 60 7400 ES 425 250 115 60 62 Nominal data Subject to alterations 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions 218 Guard grilles from p. 242 tin-pla ted Curve Service life L10 at 40 °C 47,0 Type Series 7400 at T max Temperature range 6,8 Sound power level Hours Sound pressure level °C Frequency rpm Nominal voltage Watts Air flow / Air flow – – Nominal speed – Input power – – Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Intake over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 single wires, wire ends with brass lead tips grounding lug for M4 x 8 Mass: 1,1 kg Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 194. Sintec sleeve bearings Ball bearings – Material: Hours 500 m /h Information max. AC axial fans 3 Ø 172 x 51 mm DC centrifugal fans -25...+70 62 000 / 31 000 2 800 -25...+60 62 000 / 39 000 60 6,4 26,0 3 300 -25...+70 57 000 / 28 000 58 6,7 29,0 3 300 -25...+75 57 000 / 22 000 VAC Hz dB(A) Bel(A) 6058 ES 375 221 230 50 55 6078 ES 420 247 230 50 54 6008 ES 440 259 115 60 6028 ES 500 284 115 60 Hours ➀ ➁ ➂ ➃ ACmaxx / EC fans cfm DC fans - specials Service life L10 at 40 °C 2 800 26,0 m3/h Accessories AC centrifugal fans AC axial fans Subject to alterations Guard grilles from p. 242 219 2016-01 Air performance measured as per: ISO 5801, Installation category A, without accidental contact. Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis. The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup, the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions Representatives Nominal data Curve Temperature range 24,0 6,3 Type Series 6000 at T max Nominal speed 5,9 Sound power level Hours Sound pressure level °C Frequency rpm Nominal voltage Watts Air flow / Air flow – – Input power – Sintec sleeve bearings Ball bearings – – Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 flat plugs 2,8 x 0,5 mm grounding lug for M4 x 6 Mass: 1,0 kg Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page 196,198. DC axial fans – Material: 1 000 m /h AC axial fans 3 225 x 80 mm – Material: Max. back-pressure Perm. amb. temp. Mass C D Sound power level M2E 068-BF B Capacitor W2E 200-HK38-01 A Input current M2E 068-BF Input power W2E 200-HK86-01 Speed / rpm Motor Air flow Type Frequency Nominal data Number of blades: Direction of air flow: Direction of rotation: Degree of protection: Insulation class: Mounting position: Condensate discharges: Mode of operation: Bearings: Nominal voltage Curve – – – – – – – – – Housing: Die-cast-aluminium Impeller: Sheet steel, coated in black Rotor: Coated in black 7 "V" Counter-clockwise, seen on rotor IP 44, depending on installation and position "B" Any None Continuous operation (S1) Maintenance-free ball bearings Electrical connection max. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg 1~115 1~115 50 60 880 1 000 2 550 2 800 64 80 0,58 0,70 5,0/220 5,0/220 ----- 80 -25...+60 95 -25...+65 2,0 2,0 p. 263 / A1) 1~230 1~230 50 60 880 1 000 2 550 2 800 64 80 0,29 0,35 1,5/450 1,5/450 ----- 80 95 2,1 2,1 p. 263 / A1) -25...+60 -25...+65 Pa Curves: in wg Subject to alterations n rpm Ped W I A L WA dB(A) B D 80 A C 0.2 60 40 20 Pfs 0 qv 100 200 200 300 400 400 600 500 800 cfm m³/h 2016-01 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions 220 A 1 2 640 56 0,56 --- A 2 2 595 58 0,57 --- A 3 2 550 61 0,58 --- A 4 2 480 64 0,60 --- B 1 2 980 67 0,58 --- B 2 2 880 71 0,62 --- B 3 2 790 75 0,65 --- B 4 2 660 80 0,69 --- C 1 2 630 60 0,30 --- C 2 2 585 64 0,31 --- C 3 2 530 66 0,31 --- B 4 2 480 69 0,32 --- D 1 3 000 70 0,31 --- D 2 2 935 73 0,32 --- D 3 2 850 77 0,34 --- D 4 2 705 83 0,36 --- 0.4 100 Information Motor protection: Touch current: Cable exit: Electrical connection Protection class: Product conforming to standards: – Approvals: TOP wired internally < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4) Variabel Via terminal strips (operating capacitor connected) I (if customer has provided connection for protective earth) DC axial fans – – – – – – ACmaxx / EC fans DC fans - specials DC centrifugal fans EN 60335-1, CE A B EAC, UL 507, VDE, CSA C22.2 Nr. 113, CCC C D EAC, UL 2111, VDE, CSA C22.2 Nr. 113, CCC AC centrifugal fans 22 5 AC axial fans "V" › N N L Ø4.5 +0.2 (8x) Accessories PE L Connection cables p. 263 7 80 ±0.3 221 Representatives Guard grilles p. 245 7 2016-01 Ø240 Ø260 1 880 m /h AC axial fans 3 225 x 80 mm – Material: Max. back-pressure Perm. amb. temp. Mass VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg 1~115 1~115 50 60 1 740 1 880 2 375 2 350 125 165 1,10 1,45 12/320 12/320 70 72 100 -25...+50 110 -25...+45 2,7 2,7 p. 263 / A3) 1~230 1~230 50 60 1 695 1 840 2 320 2 300 125 160 0,55 0,71 3,0/400 3,0/400 70 71 100 110 2,7 2,7 p. 263 / A3) Pa 100 B D A C 0.3 80 0.2 60 0.1 40 20 Pfs 0 qv 200 400 400 600 800 800 1200 1000 1600 cfm m³/h 2016-01 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions n rpm Ped W I A L WA dB(A) A 1 2 580 108 0,96 70 A 2 2 510 115 1,02 69 A 3 2 455 121 1,06 68 A 4 2 375 125 1,10 68 B 1 2 785 149 1,30 72 B 2 2 655 154 1,35 70 B 3 2 490 162 1,41 70 B 4 2 350 165 1,45 70 C 1 2 550 101 0,44 70 C 2 2 480 109 0,47 69 C 3 2 410 115 0,50 68 B 4 2 320 125 0,55 68 D 1 2 750 134 0,59 71 D 2 2 600 145 0,63 70 D 3 2 420 152 0,66 69 D 4 2 300 160 0,71 70 0.4 Curves: 222 -25...+60 -25...+50 (1) Nominal data in operating point with maximum load and 115/230 VAC in wg Subject to alterations C D Sound power level M2E 068-CF B Capacitor W2E 250-HP06-01 A Max. Input current(1) M2E 068-CF Max. Input power(1) W2E 250-HP08-01 Speed / rpm(1) Motor Air flow Type Frequency Nominal data Number of blades: Direction of air flow: Direction of rotation: Degree of protection: Insulation class: Mounting position: Condensate discharges: Mode of operation: Bearings: Nominal voltage Curve – – – – – – – – – Housing: Die-cast-aluminium Impeller: Plastic PP Rotor: Coated in black 7 "V" Counter-clockwise, seen on rotor IP 44, depending on installation and position "F" Any None Continuous operation (S1) Maintenance-free ball bearings Electrical connection max. Information TOP wired internally < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4) Variabel Via terminal strips (operating capacitor connected) I (if customer has provided connection for protective earth) DC axial fans Motor protection: Touch current: Cable exit: Electrical connection Protection class: Product conforming to standards: – Approvals: EN 60335-1, CE A B UL 2111, CSA C22.2 Nr. 77 C D EAC, UL 2111, CSA C22.2 Nr. 77 ACmaxx / EC fans DC fans - specials DC centrifugal fans – – – – – – 4x90° 15° 20° "V" › 4x9 0° (8x) 90 AC axial fans Ø2 N L "V" › W2E 250-HP06-01 7 0 90 Ø2 +0.2 Ø4.4 80±0.5 28 7 AC centrifugal fans Ø5.4+0.25 PE 28 0 (8x) Ø295 Ø320 N L Guard grilles p. 245 Connection cables p. 263 7 7 80±0.5 223 2016-01 Ø295 Ø320 Representatives Ø5.4+0.25 (8x) PE Accessories 4x90° 4x90° 20° W2E 250-HP08-01 15° +0.2 Ø4.4 max. 850 m /h AC diagonal module 3 Ø 200 mm Max. back-pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 1~ 115 1~ 115 50 60 760 830 2 650 2 910 64 88 0,56 0,77 6,0/250 6,0/250 70 72 200 240 Electrical connection Sound power level B Capacitor A Input current M2E 068-CF Input power K2E 200-AA12 -01 Speed / rpm Motor Air flow Type Frequency Nominal data Number of blades: Direction of air flow: Direction of rotation: Degree of protection: Insulation class: Mounting position: Condensate discharges: Mode of operation: Bearings: Nominal voltage Curve – – – – – – – – – Housing: Plastic PA Support bracket: Plastic PA Impeller: Plastic PA Rotor: Coated in black 7 "V" Clockwise, seen on rotor IP 44, depending on installation and position "F" Any None Continuous operation (S1) Maintenance-free ball bearings Mass – Material: kg -25..+65 2,1 -25..+65 2,1 p. 263 / A1) Subject to alterations n rpm Curves: 50 Hz B 60 Hz 2016-01 224 I A L WA dB(A) A 1 2 650 64 0,56 70 A 2 2610 67 0,59 68 A 3 2 580 70 0,61 67 A 4 2 590 69 0,61 69 B 1 2 910 88 0,77 72 B 2 2 815 93 0,81 69 B 3 2 755 96 0,84 69 B 4 2 780 95 0,83 71 A Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Ped W Information DC axial fans TOP wired internally < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4) Lateral Via connector I (if customer has provided connection for protective earth) EN 60335-1, CE UL 2111, CSA C22.2 Nr. 77 ACmaxx / EC fans DC fans - specials DC centrifugal fans Motor protection: Touch current: Cable exit: Electrical connection Protection class: Product conforming to standards: – Approvals: AC axial fans X Electrical connections p. 263 View X 1 2 3 Accessories 1 = not used 2 = N + condensator 3=L 4 = PE 4 225 Representatives Coded plug system Universal-Mate-N-Lok Connector shell: AMP 350 780-1 3 x Pin connector: AMP 926 885-1 Mating connector (not part of delivery): Connector shell: AMP 350 779-4 3 x female terminal: AMP 926 884-1 AC centrifugal fans Mounting dimensions 2016-01 – – – – – – max. 850 m /h AC diagonal module 3 Ø 200 mm Max. back-pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 1~ 230 1~ 230 50 60 765 845 2 650 2 950 65 90 0,30 0,40 2,0/400 2,0/400 70 73 200 245 Electrical connection Sound power level B Capacitor A Input current M2E 068-CF Input power K2E 200-AA52 -02 Speed / rpm Motor Air flow Type Frequency Nominal data Number of blades: Direction of air flow: Direction of rotation: Degree of protection: Insulation class: Mounting position: Condensate discharges: Mode of operation: Bearings: Nominal voltage Curve – – – – – – – – – Housing: Plastic PA Support bracket: Plastic PA Impeller: Plastic PA Rotor: Coated in black 7 "V" Clockwise, seen on rotor IP 44, depending on installation and position "F" Any None Continuous operation (S1) Maintenance-free ball bearings Mass – Material: kg -25..+80 2,1 -25..+80 2,1 p. 263 / A1) Subject to alterations n rpm Curves: 50 Hz B 60 Hz 2016-01 226 I A L WA dB(A) A 1 2 650 65 0,30 70 A 2 2 620 67 0,30 68 A 3 2 605 68 0,30 67 A 4 2 610 68 0,30 69 B 1 2 950 90 0,40 73 B 2 2 865 93 0,41 70 B 3 2 820 96 0,42 69 B 4 2 840 94 0,41 71 A Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions Ped W Information DC axial fans TOP wired internally < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4) Lateral Via connector I (if customer has provided connection for protective earth) EN 60335-1, CE UL 2111, CSA C22.2 Nr. 77 ACmaxx / EC fans DC fans - specials DC centrifugal fans Motor protection: Touch current: Cable exit: Electrical connection Protection class: Product conforming to standards: – Approvals: AC axial fans X Electrical connections p. 263 View X 1 2 3 Accessories 1 = not used 2 = N + condensator 3=L 4 = PE 4 227 Representatives Coded plug system Universal-Mate-N-Lok Connector shell: AMP 350 780-1 3 x Pin connector: AMP 926 885-1 Mating connector (not part of delivery): Connector shell: AMP 350 779-4 3 x female terminal: AMP 926 884-1 AC centrifugal fans Mounting dimensions 2016-01 – – – – – – max. 880 m /h AC diagonal module 3 Ø 200 mm Max. back-pressure Perm. amb. temp. VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C 3~ 400 Y 3~ 400 Y 50 60 780 880 2 700 3 050 65 90 0,15 0,16 ----- 71 73 210 260 Electrical connection Sound power level B Capacitor A Input current M2D 068-CF Input power K2D 200-AA02 -02 Speed / rpm Motor Air flow Type Frequency Nominal data Number of blades: Direction of air flow: Direction of rotation: Degree of protection: Insulation class: Mounting position: Condensate discharges: Mode of operation: Bearings: Nominal voltage Curve – – – – – – – – – Housing: Plastic PA Support bracket: Plastic PA Impeller: Plastic PA Rotor: Coated in black 7 "V" Clockwise, seen on rotor IP 44, depending on installation and position "F" Any None Continuous operation (S1) Maintenance-free ball bearings Mass – Material: kg -25..+75 2,0 -25..+75 2,0 p. 263 / C2) Subject to alterations n rpm Curves: Ped W I A L WA dB(A) B 50 Hz 60 Hz A 2016-01 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions 228 A 1 2 700 65 0,15 71 A 2 2 695 69 0,16 69 A 3 2 675 71 0,16 68 A 4 2 680 70 0,16 69 B 1 3 050 90 0,16 73 B 2 3 010 94 0,16 71 B 3 2 970 98 0,17 70 B 4 2 975 96 0,17 72 Information DC axial fans TOP wired internally < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4) Lateral Via connector I (if customer has provided connection for protective earth) EN 60335-1, CE ACmaxx / EC fans DC fans - specials DC centrifugal fans Motor protection: Touch current: Cable exit: Electrical connection Protection class: Product conforming to standards: AC axial fans X Electrical connections p. 263 View X 1 2 3 Accessories 1 = L3 2 = L1 3 = L2 4 = PE 4 229 Representatives Coded plug system Universal-Mate-N-Lok Connector shell: AMP 350 780-1 3 x Pin connector: AMP 926 885-1 Mating connector (not part of delivery): Connector shell: AMP 350 779-4 3 x female terminal: AMP 926 884-1 AC centrifugal fans Mounting dimensions 2016-01 – – – – – – 2016-01 230