Lock - ALPE

ACTIVE COMPONENTS
@Lock
10.12 to 10.18
10
10.11
ACTIVE COMPONENTS
Problems with locking systems
Unauthorized access
- By own employees
- By external companies
- Uncontrolled access
- Decentralised access authorizations
- Key problem
- Loss of key
- Single key system
- Many different keys
The mechanical/electro-mechanical comparison
MIR20107
Cylinder lock systems
+ Simple technical version
+ Cost-effective with individual locking
+ No power supply required
- Easily duplicated
- Replacement (among other factors)
problematic
- Code conversion expensive with locking
systems
- Key-connected, which means transferable with key hand-over (theft)
- Logging and monitoring very
expensive/time-consuming
Electronic systems
+ Various locking options
+ Opening permission possible without a
key being required
+ Opening permission can be
granted/withdrawn almost immediately
+ Lock control / logging possible
+ Remote opening per PC / Internet / mobile phone / SMS
+ Expandable and easy code conversion
lock system
- Power supply required
Locking solutions
Control components to choose from
Electronic locking systems
Mechanical combination lock
Standard locking with half-cylinder
MIR20113
MIR20285
10.12
MIR20134
ACTIVE COMPONENTS
Modules
Control components for electronic locking systems
Transponder
Interlocking: security with multi-point interlocking mechanism
Network (server)
MIR00423
Decentralised rack suite
- Each rack/each door can be opened separately - via own address
Access authorization administration
Access monitoring
Locking mechanism control
Access logging
MIR20102
10.13
ACTIVE COMPONENTS
Embedded solution
Administration
Monitoring
Logging
Remote access
Network
●
● LAN
●
● WAN
●
● Internet
●
●
MIR20099
Individual Locking / Stand-Alone Solution
Access authorization administration
Monitored access
Locking mechanism control
Access logging
MIR20094
10.14
ACTIVE COMPONENTS
@Lock®
Strong points
The very small and modular design means that no additional
space or greater installation
depths are required in the rack.
Each device of the series can be
networked with the other devices,
which results in numerous possible combinations and options.
Contacts for emergency power
supply that can be activated externally using trade standard batteries are integrated into each
swing handle.
Every opening process can be
logged in the network. Existing
network structures can be used
for networking.
An integrated light-emitting diode
signals with different colours to
inform whether or not the current
access is authorised.
MIR20109
@Lock®Swing Handle
Security for racks in the data and networking area
- Conventional keys are replaced by electromechanical locking components.
- A servomotor pulls the retaining awl back
and releases the handle.
- Actively opening the door is, however, made
with the hand as before.
- Easy exchange of the swing handle with later
installation using unchanged installation
opening.
- Intended for standardised installation openings of conventional swing handle.
- Can be quickly and easily upgraded to locking system.
- Convenient administration of access authorizations.
MIR20284
@Lock Swing Handle, HID/IP
- The swing handle opens after a registered transponder card has been read.
- With the HID variant, the communication
between swing handle and PC runs via a
junction box and a server.
- The IP swing handle, by contrast, is configured via an IP address and is connected directly via the network to the PC.
- Up to 2,048 HID cards per swing handle
can be configured using a registered
master card.
- Configuration of the cards via the network is also possible with the optional
software.
Technical data
@Lock Swing Handle, HID
(optional IP remote connection)
- 100...240VAC, power supply not included
in the supply schedule
- Operation with 12VDC/40mA
(max. 430mA)
- Multi-colour status – LED
- Real-time clock
- Network communication is made via
external server (gateway)
- Up to 250 handles can be administered
per server (IP address)
@Lock Swing Handle, IP
- 100...240VAC, power supply not included
in the supply schedule
- Operation with 12VDC/40mA
(max. 430mA)
- Multi-colour status – LED
- Real-time clock
- Network communication with cabled
connection via integrated Ethernet
10/100 Base T
Function
- Opens after reading a registered card
- Memory for 32 time segments
- Memory for 2,048 cards per handle
- Integrated logbook for 500 events
- Result-related communication
- 125 kHz transponder with unique code
(HID 26 bit system)
Supply schedule
@Lock Swing Handle, HID
1 swing handle, HID
1 reader
1 reader connection cable
1 network node, CX2001
1 network cable, CN2001
1 optional Data CD per Order
Supply schedule
@Lock Swing Handle, IP
1 swing handle, IP
1 reader
1 reader connection cable
1 data CD optional
-
10.15
ACTIVE COMPONENTS
@Lock®Junction Box, CX2001
MIR20280
The junction box is used to consecutively
switch the swing handle of the HID series and
connect with the server. The junction box has
three ports – INPUT, MODULE and OUTPUT.
INPUT – The INPUT is connected with the output of the previous junction box of the previous
handle of the strand. The INPUT port of the
first junction box is connected with the server.
These connections are set up with the CN2001
cable.
MODULE– The MODULE port is connected via
a CN2001 cable with the reader module of the
HID series.
OUTPUT – The OUTPUT port is connected with
the INPUT of the next junction box of the
strand. If the junction box is the last of the
strand, the termination pull-up resistor is attached to the OUTPUT port (included in the
server supply schedule).
Technical data
- Operating voltage, 12V DC/throughput
current, 1.5 A max.
- 3 outputs, modular plug, 8p/8c (RJ45)
- 1 input, DC socket with 2.1 mm pin
- Earthing screw, M4, earth connected
with GND
Function/applications
- @Lock electrical connection
- Lightening and overvoltage protection
module
- EMC fault attenuation
- Installation simplification
- Voltage connection
(with circuit breaker)
- Interconnection of HID equipment
- HID equipment power supply
@Lock® Server
The @Lock Server is the interface between the
HID swing handles connected via the RS485
cable and the network connected via X-Port. It
is used for intermediary storage of results and
tasks and can administer up to 250 users
(swing handle).
The X-Port can be configured using the RS
232 interface. The @Lock Server has an integrated real-time clock, which is buffered when
power fails for up to 1 hour.
MIR20283
10.16
Technical data
- Power supply: via an external plug-in
power supply, 12V
(DC)
- Nominal current:
80mA (DC)
- Max. power consumption:
200mA (DC)
- Main board
interface:
- PC interface:
- Network interface:
RS 485
cable
(A, B, GND,
+12V), max.
length to
the next
gateway 5m
RS 232 cable
(RXD, TXD, DTR,
RTS, GND, +12V),
RJ 45 plug,
8-pole
X-Port, RJ 34
plug, 8-pole
Max. 10 x 250
tasks
Max. 100
events
250 units
- Memory space for
tasks:
- Memory space for
events:
- Max. number
swing handles:
- Integ. real-time clock: With buffering up
to 60 min at 25ºC
ACTIVE COMPONENTS
@Lock® Software Programme
The @Lock software is the user interface for
controlling and configuring the @Lock Swing
Handle. Using this software, the administrator
can create access codes and HID cards and
assign users. The handle can be controlled in
real-time from the software platform. All actions that are directly related with the swing
handles are stored in an SQL database (e.g.
opening, closing, granted accesses and accesses rejected on the basis of non-authorization).
MIR20282
Technical data
- MS Windows 2000/NT etc.
- SQL database
- TCP/IP network connection to the swing
handles
- The number of handles and gateways is
only restricted by the capacity of the
computer
- Communication with swing handle via
server (gateways) or directly with @Lock
Swing Handle, IP
Functions/applications
- Stand-alone administration programme
for the @Lock system
- Requires max. 3-4 seconds for a status
update
- Administration of users and rights
- Administration of HID cards, opening of
active keys and access codes, closing,
activation or deactivation of swing
handles
- Observation of authorised and unauthorised access attempts
- Recording of all events connected with
swing handles
- Central observation of swing handle
- Combination of all swing handles and
servers
- Events recording
@Lock® Desktop Reader
The transponder cards are read into the administration software using the desktop
reader. This enables the later configuration of
the access media in the system (lock plan creation). The desktop reader is connected via the
RS-232 interface with the PC on which the administration software is installed. The
transponder card is inserted in the read-out
unit for reading the transponder ID. The reading process can then be initiated in the administration software by hitting a key.
MIR20281
Technical data
- Power supply:
12V +- 10%
(DC max. 400mA)
via low voltage
socket
- Nominal current: 80mA (DC)
- RS232 interface: RS 232 cable
(RXD, TXD, GND,
reader present,
PC present),
38,400 baud
- Connection cable: (reader – read-out
unit) 8-pole,
250 cm, UL stranded
wire AWG 26
Model
Order no.
UP
@Lock Server, HID
01.180.011.9
1 unit
@Lock Swing Handle, HID
01.180.022.9
1 unit
@Lock Swing Handle, IP
01.180.023.9
1 unit
@Lock Network Node, CX2001
01.180.030.9
1 unit
@Lock Network Cable, CX2001
01.180.031.9
1 unit
@Lock Desktop Reader HID
01.180.028.9
1 unit
@Lock Transponder Card
01.180.040.9
1 unit
Power Supply, PMI 2001, EU
01.180.035.9
1 unit
Power Supply, PMI 2001, UK
01.180.036.9
1 unit
Power Supply, PMI 2001, US
01.180.037.9
1 unit
Power Supply, PMI 2001, Japan
01.180.038.9
1 unit
Power Supply, PMI 2001, Australia
01.180.039.9
1 unit
10.17
ACTIVE COMPONENTS
Combi Lock
Security and flexibility realised mechanically
- This additional lock, the aptly named “Override”, produces a combination swing handle
with particularly special advantages
- Innovative combination swing handle with
two activation options
- Independent opening and closing of the
swing handle via combination or cylinder
lock
- General key function possible with rack
suites
- Can be used for right and left closing doors
Installation
In the standard installation opening of the
Miracel rack doors. Quick mounting with
plug-in connections and screw fittings.
Technical data
- Cylinder lock
- Combination lock can be
individually set with 3 digits
- Independent activation
Supply schedule
1 swing handle with combi lock
1 mounting material set
Model
Order no.
Combi Lock
MIR20095
Dimensions in mm: W =
H =
D =
h =
d =
L =
Width
HU = Standard height unit
Height
1 HU = 44.45 mm
Depth
UP = Unit of packaging
Installation height kg = Weight
Useable depth
Length
= Express item
Conversion: 1 mm = 0.03937 inch
10.18
1 kg = 2.2046 pound
UP
01.137.013.9