Secure Power Always MP-NET from 20 to 120 kVA Uninterruptible power supply Chloride Systems WORLD HEADQUARTERS Via Fornace 30 40023 Castel Guelfo (BO) Italy T +39 0542 632 111 F +39 0542 632 120 E [email protected] www.chloridepower.com Chloride operates through a worldwide network of Chloride sales and service offices and joint ventures, with operations across 80 countries including: Almaty, Kazakhstan Bangkok, Thailand Beijing, China Makati City, Philippines Bologna, Italy Buenos Aires, Argentina Chicago, USA Dubai, UAE Erlangen, Germany Ho Chi Minh City, Vietnam Lisbon, Portugal Istanbul, Turkey Madrid, Spain Moscow, Russia Paris, France Pune, India Diadema, Brazil Shanghai, China Singapore Southampton, UK Sydney, Australia Warsaw, Poland • Principal sales & service offices • Service network Chloride Australia Ground Floor, 16 Giffnock Avenue North Ryde NSW 2113 Australia Chloride Middle East Arenco Tower, Office 608 Dubai Internet City - Dubai UAE PO Box 72536 Chloride Secure Power Philippines, Inc. 7F Y-L Finance Building, Corner of Rufino & Salcedo Streets Legaspi Village, Makati City Philippines CHLD Singapore Pte Ltd 200 Pandan Loop #06-03 Pantech 21 Singapore 128388 T +61 2 9888 1266 F +61 2 9888 1966 E [email protected] T +971 4 434 5201 F +971 4 430 8032 E [email protected] T +63 2 810 0068 F +63 2 812 0433 E [email protected] T +65 6481 4776 F +65 6481 0552 E [email protected] www.chloridepower.com.au www.chloridepower.com/middle-east www.chloridepower.com www.chloridepower.com.sg Chloride UK George Curl Way Southampton Hampshire, SO18 2RY United Kingdom Chloride North America 27944 North Bradley Road Libertyville, IL 60048 USA Chloride Power Protection Limited 1093/98-99 M. 12 Central City Tower 1 18th floor, Bangna-Trad Road (K.M.3) Bangna, Bangkok 10260 Thailand Eltek UPS AB Hammarbacken 4A, 191 24 Sollentuna Sweden T +1 847 816 6000 +1 800 327 8801 F +1 847 680 5124 E [email protected] www.chloridepower.co.uk www.chloridepower.com/usa T +66 2762 3600 F +66 2745 6618 E [email protected] www.chloridepower.com/th For a full list of contacts please visit our website at www.chloridepower.com T +84 8 255 6737 F +84 8 255 6800 www.chloridepower.com/vn T +46 8 626 64 20 F +46 8 626 64 30 E [email protected] www.eltekups.se MKA4L0UKMPN T +44 (0) 23 8061 0311 F +44 (0) 23 8061 0852 E [email protected] Chloride Vietnam Unit 1708, 17th Floor, Gemadept Tower 06 Le Thanh Ton Street Ben Nghe Ward, District 1 Ho Chi Minh City Vietnam Technical data MP-NET RATINGS PRIMARY INPUT Nominal voltage(1) (V) Voltage range (V) Minimum voltage without battery discharge (V) Nominal frequency (Hz) Frequency range (Hz) Maximum input current @ ambient temperature within the range 0°C to 40°C (A) Power factor @ nominal load & nominal input conditions(2) Input current distortion @ nominal input conditions & nominal output power(3) (%) Walk in/Soft start (seconds) Rectifier Hold-Off (seconds) Inrush current / Imax input(4) AC/DC Rectifier efficiency without charging current @ nominal input conditions(2) with resistive load: - Half load(6) ≥ (%) - Full load(6) ≥ (%) BATTERY Permissible battery voltage range (V) Recommended no. of cells: - VRLA(5) - WET - NiCd Float voltage for VRLA @ 25°C (V/cell) End cell voltage for VRLA (V/cell) Float voltage temperature compensation DC ripple current in float mode for a 10 min autonomy as per VDE0510(5) Float Voltage stability in steady state condition (%) DC ripple voltage without battery (%) Optimum battery temperature (°C) Maximum Battery recharge current for 240 cells @ 400V input voltage & nominal load (A) Battery output power in discharge mode with nominal output load (kW) End battery voltage for 240 cells (V) End battery current for 240 cells with nominal output load (A) INVERTER OUTPUT Nominal apparent power @ 40°C (kVA) Nominal active power (kW) Nominal output current (A) Overload at nominal output voltage for 10 minutes(8) (%) Overload at nominal output voltage for 1 minute(8) (%) Short circuit current for 300ms (%) Nominal output voltage (V) Nominal output frequency (Hz) Voltage stability in steady state condition for input (AC & DC) variations and step load (0 to 100%) (%) Voltage stability in dynamic condition for input variation (AC & DC) and step load (0 to 100% and vice versa) (%) Voltage stability in steady state for 100% load imbalance (0, 0, 100) (%) Output frequency stability - synchronised with bypass mains (%) - synchronised with internal clock Frequency slew rate (Hz/sec) Output voltage distortion with 100% linear load (%) Output voltage distortion @ reference non linear load as IEC/EN 62040-3 (%) Load crest factor handled without derating the UPS (Ipk/Irms) 20 40 60 80 100 120 400 (380, 415 selectable), three-phase + neutral 300 to 477 208Vac (at 70% output load) 50/60 [selectable] 45 to 65 33 66 98 131 164 197 96.5 97 96.5 97 96.5 97 >0.99 <5 30sec N/A ≤1 96.5 97 96.5 97 96.5 97 ± 240 240 cells 240 cells 375 cells 2.27 1.67 -3.96mV/cell, raise 1°C <0.02C10 1 1 15 to 25 5 17 10 34 15 51.1 20 68.1 25 85.1 30 102.1 42.5 85.1 127.7 ±200 170.2 212.8 255.3 20 16 29 40 32 58 60 48 87 100 80 145 120 96 174 80 64 116 <125 <150 300 400 (380, 415 selectable), three-phase + neutral 50 [60Hz selectable] ±1 ±7 ±1 ±5 (±0.1~±5 selectable) ±0.05 <1 <3 <5 3 20 40 60 80 100 120 96.5 97 96.5 97 96.5 97 1.5° 2° 96.5 97 96.5 97 96.5 97 110 105 100 400 (380, 415 selectable), three-phase + neutral 50/60 [selectable] ±5 (±0.5 ~ ±5 selectable) ±15 (±8 ~ ±15 selectable) <1 <1 <10 92.5 93.5 94 95 92.5 93.5 94 95 92.5 93.5 94 95 92.5 93.5 94 95 92.5 93.5 94 95 92.5 93.5 94 95 14.2 70 17.7 70 21.3 70 98 3.6 65 7.1 67 10.7 69 IP20 1165 520 910 1700 520 950 1 9005 169 199 229 259 Bottom Front/Side/Rear Forced Ventilation 349 379 0 to 40 <95 1500 (1) In case of a split input configuration, the primary input and the bypass input must have a common neutral. The neutral conductor may be connected only to the bypass or primary mains but it must be present (bypass and primary neutrals are solidly connected inside the UPS). (2) At nominal voltage and nominal frequency. (3) With input voltage at nominal value and with voltage distortion THDv <1%. (4) “Imax input” parameter can be calculated using the maximum input power @ 400V in battery recharge mode. (5) Permitted number of cells = 240 (6) For tolerances see IEC/EN 60146-1-1 or DIN VDE 0558. (7) Recommended average daily ambient temperature 35°C with a maximum of 40°C for 8 hours. (8) Conditions Apply. This publication is issued to provide outline information only and is not deemed to form any part of any offer and/or contract. The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary any information without prior notice. MKA4L0UKMPN REV. 3 - 07/2010 MP-NET RATINGS INVERTER OUTPUT Phase angle precision with balanced loads (degrees) Phase angle precision with 100% unbalanced loads (degrees) DC/AC Inverter efficiency @ nominal input conditions(2) with resistive load: ≥ (%) - Half load(6) - Full load(6) ≥ (%) Output power upgrading with ambient temperature: - At 25°C (%) - At 30°C (%) - At 40°C (%) STATIC BYPASS (V) Nominal bypass voltage(1) Nominal frequency (Hz) Frequency range (Hz) Voltage range (%) Transfer time with inverter synchronised to bypass: - Inverter to Bypass (ms) - Bypass to Inverter (ms) Transfer time with inverter not synchronised to bypass (ms) SYSTEM DATA AC/AC efficiency without charging current @ nominal input conditions(2) with resistive load: - 25% load(6) (%) - 50% load(6) (%) - 75% load(6) (%) (%) - 100% load(6) - VFD6) (%) Heat dissipation: - Recharge mode (kW) Noise @ 1 metre as per ISO 3746(8) (dBA ± 2dBA) Protection degree with open doors Mechanical dimensions: - Height (mm) - Width (mm) - Depth (mm) No. of cabinets Frame colour (RAL scale) Weight (kg) Cable entry Access Cooling ENVIRONMENTAL Temperature: - Operating temperature(7) (°C) - Maximum relative humidity @ 20°C (non condensing) (%) Max altitude above sea level without derating (m) Secure Power Always MP-NET from 20 to 120 kVA Chloride's MP-NET is a modular solution designed to grow with evolving load requirements, making it the perfect solution to power modular distributed networks. MP-NET has been developed to meet the highest standards of serviceability, flexibility and scalability, while also having maximum energy and space saving features, guaranteeing maximum availability. The smart solution that easily adapts to run time requests Key performances MP-NET offers the most secure and flexible system architecture able to grow with your business. This modular solution is made up of a bespoke cabinet that is able to house 20 kVA power modules. Bespoke cabinets are available in two sizes to suit either up to 4 or 6 power modules. Power modules can easily be added to the cabinet at any time without dropping the load or making other changes to the battery bank. MP-NET offers the most secure and flexible system architecture together with intelligent double conversion. Leading 10 0 60 Cos ϕ 0.9 40 100% KW 20 0 25 50 Cos ϕ 1 100 75 100% KW 20 40 Cos ϕ 0.9 60 Cos ϕ 0.8 80 100 KVA 100% Cos ϕ 0.6 Lagging MP-NET: adapts to business needs for maximum availability MP-NET is easy to install and service thanks to its modular design. (that could potentially damage the system or even cause the load to crash). The Hot Swap feature makes it possible to plug in a power module while maintaining maximum load security. This means that the power module is replaceable without having to transfer the load to the raw mains. Furthermore making it easy for the user to perform basic service interventions. Each power module provides a 5A battery charging current, guaranteeing full redundancy and long autonomy battery configurations, making it compatible with many different types of installations. The replacement or scaling is achieved without any risk of handling errors Cos ϕ 0.5 80 A KV The main features of the MP-NET are: • IGBT double conversion technology • Excellent input performances: • PF > 0.99 • THDi < 5% • High conversion efficiency (up to 98%) • Output PF up to 0.9 • Capability to power leading and lagging loads without derating • 300% short circuit current • Dual separated rectifier and bypass input • Cold start 100 % MP-NET represents the best solution for parallel redundant systems; maximising system efficiency, and minimising the total cost of ownership thanks to: • Hot Swap plug-in modules • High conversion efficiency • Reduced footprint (optimising layout space and transport costs) • Optimised N+1 redundant configurations up to 5N+1. KVAr Hot Swappable plug-in/out power modules make MP-NET perfectly suitable for parallel redundant configurations, especially when minimum space impact is required. Kw Geographical modularity - maximum flexibility for customised solutions MP-NET is a dynamic modular UPS ideal for applications such as data centres, transport, communications, and distributed networks. MP-NET is designed to meet the changing requirements of loads located in different geographical areas, making it the best solution to maximise system efficiency, reduce running costs and minimise the total cost of ownership. The flexible design of the power modules makes it possible to move them easily from one bespoke cabinet to another. The module is capable of powering any kind of load, leading or lagging, with no derating, and via the LIFE.net system it is also possible to constantly monitor the actual power offered. These elements combined, allow for the optimisation of energy consumption even in large distributed networks. Optimum space impact It is possible to have a 100 kVA N+1 configuration in a space of just: W 520 x H 1700 x D 950 and a 60 kVA N+1 configuration in a space of just: 1700mm W 520 x H 1165 x D 910 1165 mm 910 mm 950 mm mm 520 mm 520 Interfaces Communication MP-NET features a centralised high resolution LCD display with eight languages, allowing for easy interaction with all modules through the navigation menu. It also contains detailed information and measures of: • UPS system status • Each single power module • Battery • Electrical parameters The UPS is perfectly suitable for use in any network or building management system and offers the following standard communication features: • EPO • I/P contact closure (two) • I/P port for external battery temperature sensor • Battery cabinet status • Two smart slots (for LIFE.net and Connectivity cards). Hardware Connectivity MP-NET includes a complete suite of connectivity solutions, ensuring the monitoring and control of the networked UPS, through the TCP/IP protocol. A complete set of adaptors allow MP-NET to be integrated with building and Automation Systems via TCP/IP, MODBUS and JBUS. An external sensor box is available for monitoring the environmental conditions where the UPS systems are installed. A relay I/O card with programmable output can be inserted into the slot to monitor UPS systems and modules. components. The software works in conjunction with the Connectivity Card to provide easy, unattended shutdown of multiple computer systems across the network. It also enables the simultaneous monitoring of UPS locally and remotely. The hierarchical design makes it easy to manage UPS intuitively. Software Connectivity A complete suite of software tools allows for automatic and scheduled shutdowns as well as a variety of other features that help manage the system and its peripheral Tailored sizing for maximum efficiency Tailoring your power protection system to use only the necessary power required makes for a smart investment which is more economic to run. Efficiency Curve of MP-NET 5N+1 configuration 95 % The modular design of this UPS allows it to work at maximum efficiency by offering the possibility of adding or removing modules according to the load requirement. This in turn enables it to obtain significant energy savings even at partial load. A power upgrade can be made whenever necessary avoiding system oversizing which could potentially lead to higher running costs. 0 50 100 load (%) Service and LIFE.net 24/7 remote diagnostic system Installation is only the beginning of your relationship with Chloride as it is essential that your critical power protection system is maintained in an optimum state of readiness at all times. The innovative range of maintenance and support services available from Chloride ensure reliability for life-long protection. Chloride takes responsibility for the health of your UPS units 24 hours per day. The LIFE cycle LIFE.net is the maintenance program which includes the remote diagnosis, monitoring and managing of the operational status of UPS and power distribution systems. LIFE.net provides early warning of any alarm condition or out of tolerance status, allowing effective proactive maintenance and fast incident response, giving customers complete security and peace of mind. Maximise availability Minimise downtime Reduce operating costs Pre-emptive maintenance LIFE.net provides early warning of more than 150 separate parameters allowing real-time diagnosis and swift identification and resolution of operating anomalies. Immediate identification of problems Should an emergency condition arise, a Chloride engineer in the 24x7 manned service centre carries out an immediate fault analysis and instigates appropriate corrective action. Superior asset management Through comprehensive data collection and analysis, LIFE.net’s detailed reporting system provides valuable information on power and equipment trends, over any selected period of time. Chloride Customers worldwide include: Alcatel American Telecom Asia Multi Media Bank of America Barclays BBC Bennet Berlin Airport Beyond Carlton TV Citibank Credit Suisse Dubai international Airport Ericsson Fastweb France Telecom HSBC Intel Ikea Kingston Linante Airport, Milan Lamborghini MTV Vodafone Radio France Otre-Mer RAI Roche Sky Telecom Aisa Tesco Kipa Tiscali Wind www.chloridepower.com