Secure Power Always 60-NET from 10 to 20 kVA Uninterruptible power supply Secure Power Always 60-NET from 10 to 20 kVA Chloride’s 60-NET offers an excellent integrated autonomy of up to 30 minutes, combined with a reduced footprint and optimum input performances, making it the best solution in its power range. Performances in real ratings 10-20 kVA 60-NET provides electrical continuity upon failure or degradation of the commercial AC source as a result of its intelligent double conversion architecture (Figure 1) with a DSP-based IGBT inverter. This allows reliable filtering of the mains network disturbances and provides stable interference-free power to the load, in turn ensuring a clean and regulated output sine wave. Equipped with an independent static bypass switch, 60-NET guarantees power system redundancy and continuity, while its enhanced connectivity suite, safe disconnection features and parallelability ensure complete load protection. BYPASS FOR MAINTENANCE Bypass STS MAIN II Line MAIN I Rectifier Booster Inverter AC DC DC DC DC = OUPUT AC N = Charger N Battery 60-NET provides reliable and secure power protection to electronic equipment loads by stocking up on high quality AC power and offering the following features: • IGBT intelligent double conversion technology • Excellent input performances: • PF > 0.99 • THDi < 5% • Inverter overload capability: • 125% for 10 min • 150% for 1 min • High conversion efficiency (certified up to 98%) • Full compatibility with any installation irrespective of the PF (leading or lagging) • Minimised footprint, easy installation and maintenance • Battery care • Excellent backup time Figure 1. Single block diagram. Parallel ready Automatic AC Bypass 60-NET is able to connect up to eight units in parallel without the need for an additional parallel board (Figure 2), thus allowing maximum power reliability and flexibility. A single unit can be upgraded to parallel by using a simple cable. AC Normal AC Normal AC Normal AC Normal AC Normal AC Normal AC Normal AC Normal The Loop Bus connection used in paralleling the system allows for prompt communication and eliminates the possibility of a single point of failure. Parallel features: • Modular parallel redundant configurations N+1 • Modular parallel scalable configurations, allowing on-site power increase. Load Figure 2. Parallel configuration of power extension and redundancy. Performance and Service 60-NET guarantees reliable and flexible secure power by adapting its performances to meet individual infrastructure requirements, making it ideal for a wide range of applications from IT and manufacturing to finance and retail. Flexibility and compatibility for customised solutions 60-NET is flexible enough to meet any power, redundancy, harmonic control and battery backup time requirements as a result of: • Optimised trade-off between harmonic rejection and efficiency • Optimised load sharing between parallel connected UPS systems and enhanced performances for unbalanced load conditions • Output Power Factor diagram symmetrical with respect to zero, up to 0.8 lagging and leading • Full compatibility with CROSS, Chloride’s static transfer switch, which provides additional protection against potential interruptions in the power distribution system by immediately switching to an alternative source in the event of a fault. Quality standard and environmental sustainability Efficiency (%) 60-NET is designed and manufactured in accordance with the following standards: • IEC/EN62040-1-1 general and safety requirements • EN62040-2 EMC requirements • IEC/EN62040-3 performance requirements 60-NET also respects the RoHS environmental directives and carries the TUV quality mark. 60-NET's battery care system is designed to minimise environmental impact by lengthening the battery life and increasing battery efficiency. With an overall efficiency of up to 98%, 60-NET allows for excellent energy savings and reduced air conditioning in all types of working conditions, even at partial loads, with significant energy savings. Serviceability The modular architecture of 60-NET optimises service intervention, as its internal modules can be easily accessed by extracting the individual drawers from the front of the UPS. All sub-assemblies have been designed to allow simplified service and maintenance to be carried out, as well as significantly reducing the Mean Time to Repair (MTTR) of individual modules. 60-NET also comes complete with casters to facilitate ease of movement and relocation. 60-NET complies with the IP 21 standard. 98 0 50 75 100 Load (%) Figure 3. 60-NET efficiency curve. Connectivity and Monitoring Communication 60-NET features a back-lit multilingual LCD display, allowing complete access to all UPS functions and guaranteeing easy interaction with the UPS through the user-friendly navigation menu. The UPS is suitable for use in any building management system and offers the following communication interfaces: • Voltage-free interface for overseeing functions offered by the AS400 system • Serial interface • Slot for LIFE.net or ManageUPSNET cards • External battery temperature monitoring connector • EPO input for emergency UPS shutdown • Backfeed contact which activates an external isolating device if the UPS detects a backfeed current over the bypass in battery mode*. In compliance with IEC/EN 62040-1-1. * The external isolating device must be provided by the customer. Hardware Connectivity ManageUPSNET ensures the monitoring and control of the networked UPS through the TCP/IP protocol allowing: • UPS monitoring from NMS via SNMP • UPS monitoring from PC via a web browser • Dispatch of e-mail notifications • Monitoring of environmental installation conditions • Possibility of integrating Chloride UPS systems with Building Monitoring and Automation Systems via MODBUS RTU, MODBUS/TCP or JBUS protocols. system in the event of a load interruption. MopUPS can also provide event logging and automatic communication of events through e-mail, SMS and other notification tools. ManageUPS CIO software provides a central management system for critical power infrastructures distributed within a building, campus or wide area network environment. Software Connectivity • MopUPS Professional • ManageUPS CIO The main function of MopUPS software is the safe shutdown of the operating LIFE.net 24x7 remote diagnostic system Installation is only the beginning of your relationship with Chloride as it is essential that your critical power protection system is maintained in an optimum state of readiness at all times. The innovative range of maintenance and support services available from Chloride ensure reliability for life-long protection. Chloride takes responsibility for the health of your UPS units 24 hours per day. The LIFE cycle LIFE.net is the maintenance program which includes the remote diagnosis, monitoring and management of the operational status of UPS and power distribution systems. LIFE.net provides early warning of any alarm condition or out of tolerance status, allowing effective proactive maintenance and fast incident response, giving customers complete security and peace of mind. Maximise availability Minimise downtime Reduce operating costs Pre-emptive maintenance LIFE.net provides early warning of the UPS parameters, allowing realtime diagnosis and prompt identification and resolution of operating anomalies. Immediate identification of problems Should an emergency condition arise, a Chloride engineer in the 24x7 manned service centre carries out an immediate fault analysis and instigates appropriate corrective action. Superior asset management Through comprehensive data collection and analysis, LIFE.net’s detailed reporting system provides valuable information on power and equipment trends, over any selected period of time. www.chloridepower.com 60-NET TECHNICAL CHARACTERISTICS Nominal primary mains input voltage Input Phases Input voltage tolerance @ full load Nominal Frequency Primary input Power Factor Input current distortion (THDi) Inrush current BATTERY CHARGER Battery nominal voltage Output voltage Battery ripple current Output current INVERTER Nominal output power at 40° C Nominal active power Power Factor Overload capacity for 10 minutes for 1 minute Short circuit current 300% @ 50 Hz 200% @ 50 Hz Nominal output voltage Output frequency (nominal) Output voltage stability by load variation 0 - 100% (static-dynamic) Output frequency variation with mains synchronization with internal reference Compatibility with loads Output voltage distortion Linear full load (%) Non Linear full load Load peak factor without derating Neutral conductor sized up to STATIC SWITCH Voltage rating Frequency (nominal) Frequency tolerance Voltage tolerance Overload capacity for 10 minutes for 1 minute In-phase switching mode bypass/inverter inverter/bypass UPS DATA No load dissipated power Maximum dissipated power 10 (V) 15 (%) (A) 400 3 Ph + N -25/+15 40 - 70 >0.99 <5 < I input max (V) (V) (%) (A) ± 180V ± 202.5V <2 5 (%) (Hz) (kVA) (kW) 10 8 (%) (%) (ms) (s) (V) (Hz) (%) (%) (%) (Ipk/Irms) 15 12 0.8 125 150 5 4 400/380 50/60 20 16 ±1 Complies with IEC/EN 62040-3, Class 1 ± 2 (1, 3, 4 selectable) ± 0.1 Any power factor (leading or lagging) up to 0.8 without output derating <2 Complies with IEC/EN 62040-3 3 1.6 I out nominal (V) (Hz) (%) (%) (%) (%) 400/380 50/60 ±2 ± 10 125 150 (ms) Make before break (0ms) (W) Float (W) Recharge (W) AC/AC efficiency DIM* mode 100% of load (%) AC/AC efficiency double conversion mode 100% of load (%) Maximum noise level @ 1 metre (dBA) EMC class 62040-2 Degree of Protection Classification according to IEC/EN 62040-3 Frame colour Cooling Equipment mobility Parallel configuration ENVIRONMENTAL Operating temperature (°C) Recommended battery temperature (°C) Maximum relative humidity @ 20 °C (without condensation) (%) Elevation without derating (-1.2 Pn every 100m above 1000m up to 3000m) (m) DIMENSIONS AND WEIGHT Height (mm) Width (mm) Depth (mm) UPS weight without batteries (kg) *Conditions apply 20 800 1000 300 1200 1400 98 92 50 ± 2 Class C2 IP21 VFI - SS - 111 RAL 7016 Forced On casters up to 8 units 1500 1800 0 - 40 +15 - +25 95 1000 118 1240 420 635 122 122 This publication is issued to provide outline information only and is not deemed to form any part of any offer and/or contract. The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary any information without prior notice. MKA4L0UK60NET REV.2 - 02/2010 Technical Data Chloride Systems WORLD HEADQUARTERS Via Fornace 30 40023 Castel Guelfo (BO) Italy T +39 0542 632 111 F +39 0542 632 120 E [email protected] www.chloridepower.com Chloride operates through a worldwide network of Chloride sales and service offices and joint ventures, with operations across 80 countries including: Almaty, Kazakhstan Bangkok, Thailand Beijing, China Makati City, Philippines Bologna, Italy Buenos Aires, Argentina Chicago, USA Dubai, UAE Erlangen, Germany Ho Chi Minh City, Vietnam Lisbon, Portugal Istanbul, Turkey Madrid, Spain Moscow, Russia Paris, France Pune, India Diadema, Brazil Shanghai, China Singapore Southampton, UK Sydney, Australia Warsaw, Poland • Principal sales & service offices • Service network Chloride Australia Ground Floor, 16 Giffnock Avenue North Ryde NSW 2113 Australia Chloride Middle East Arenco Tower, Office 608 Dubai Internet City - Dubai UAE PO Box 72536 Chloride Secure Power Philippines, Inc. 7F Y-L Finance Building, Corner of Rufino & Salcedo Streets Legaspi Village, Makati City Philippines CHLD Singapore Pte Ltd 2 Corporation Road #03-07 Corporation Place Singapore 618494 T +61 2 9888 1266 F +61 2 9888 1966 E [email protected] T +971 4 434 5201 F +971 4 430 8032 E [email protected] T +63 2 810 0068 F +63 2 812 0433 E [email protected] T +65 6481 4776 F +65 6481 0552 E [email protected] www.chloridepower.com.au www.chloridepower.com/middle-east www.chloridepower.com www.chloridepower.com.sg Chloride UK George Curl Way Southampton Hampshire, SO18 2RY United Kingdom Chloride North America 27944 North Bradley Road Libertyville, IL 60048 USA Chloride Power Protection Limited 1093/98-99 M. 12 Central City Tower 1 18th floor, Bangna-Trad Road (K.M.3) Bangna, Bangkok 10260 Thailand Eltek UPS AB Hammarbacken 4A, 191 24 Sollentuna Sweden T +1 847 816 6000 +1 800 327 8801 F +1 847 680 5124 E [email protected] www.chloridepower.co.uk www.chloridepower.com/usa T +66 2762 3600 F +66 2745 6618 E [email protected] www.chloridepower.com/th For a full list of contacts please visit our website at www.chloridepower.com T +84 8 255 6737 F +84 8 255 6800 www.chloridepower.com/vn T +46 8 626 64 20 F +46 8 626 64 30 E [email protected] www.eltekups.se MKA4L0UK60NET T +44 (0) 23 8061 0311 F +44 (0) 23 8061 0852 E [email protected] Chloride Vietnam Unit 1708, 17th Floor, Gemadept Tower 06 Le Thanh Ton Street Ben Nghe Ward, District 1 Ho Chi Minh City Vietnam