Secure Power Always 80-NETMPR from 30 to 40 kVA Uninterruptible power supply Secure Power Always 80-NETMPR from 30 to 40 kVA Chloride’s 80-NETMPR family, available from 30 to 40 kVA, delivers unique advancements in engineering and security and is ideal to guarantee reliability and secure power, even under the most difficult conditions. Real performances in real ratings, 30-40kVA Flexibility and compatibility customised solutions 80-NETMPR offers the most secure and flexible system architecture together with intelligent double conversion. It also combines the most efficient load protection barrier, provided by traditional double conversion, with the maximum efficiency provided by digital interactive technology. 80-NETMPR can be fully adapted to meet diverse requirements in terms of battery backup time, power, redundancy and harmonic control. for KVAr Leading Cos ϕ 0.5 80 10 0 % A KV 60 Maximum flexibility is also ensured from: • Output Power factor diagram symmetrical respect to zero, up to 0.9 lagging and leading • Optimum space-power ratio • Wide range of standard options including: Isolation transformer (integrated in UPS cabinet), System Bypass Switch and Synchronisation module (MBSM). • Full compatibility with CROSS, Chloride’s static transfer switch. CROSS provides additional protection against potential interruptions in the power distribution system as it provides, immediate switching to an alternative source in the event of a fault. Cos ϕ 0.9 40 100% KW 20 0 25 50 Cos ϕ 1 100 75 100% KW The main features of the 80-NETMPR are: • Transformer free • IGBT double conversion technology • Excellent input performances: • PF > 0.99 • THDi < 3% • Inverter overload capability: • 125% for 10 mins • 150% for 1 min • Automatic power upgrade up to +10% @ 25°C • High conversion efficiency (certified up to 98%) • Total compatibility with any installation irrespective of the PF (leading or lagging) 100 20 40 Cos ϕ 0.9 60 Cos ϕ 0.8 80 100 KVA 100% Cos ϕ 0.6 Lagging Parallel ready UPS The 80-NETMPR is parallel ready and can be connected in up to 8 units in parallel without the need for an additional parallel kit, allowing maximum reliability and flexibility. A single unit can be upgraded to a parallel one through a software licence code which is univocally related to the UPS, allowing Chloride to customize and adapt the total power solution. As a result of a Loop Bus connection, used to connect all parallel UPS, communication between the UPS has no single point of failure. Automatic AC By-pass AC Normal AC Normal AC Normal AC Normal AC Normal AC Normal AC Normal Load Parallel configuration of power extension and redundancy AC Normal Kw 80-NETMPR represents the best solution, both cost effective and environmental friendly, for easy installation, control and operation of data centre applications and in a wide range of sectors, including finance, manufacturing and retail. Chloride employs patented Vector Control technology (95 P3875, 95 P3879 and 96 P3198) to increase the performance of the power converters, enabling active conditioning of the load and to provide the following benefits: • Optimal trade-off between harmonic rejection and efficiency • Enhanced performance for specific unbalanced load conditions • Perfect load sharing between parallel connected UPS systems (less than 5% tolerance of any system output load fraction from 0 to 100%) • Enhanced fault clearing capacity (with 300% of the inverter nominal current for 10ms and 150% up to 5s) for downstream short circuits • Considerable cost savings throughout its service life through easy installation times and reduced servicing. Maximum energy savings Serviceability and security Environmental respect As a result of the transformer free architecture, 80-NETMPR can achieve optimum efficiency values, allowing energy savings and reducing the need for air conditioning. It has excellent efficiency in every working condition, even at partial loads that are the most common working conditions, providing great benefits for the customers. The new 80-NETMPR is designed for easy installation and serviceability thanks to the drawer-design, making it a full modular service solution and considerably minimizing the time needed for repairs. All power modules can be removed by extracting the drawers from the front of machine. 80-NETMPR , meets Chloride’s objective to acknowledge its duty towards providing the highest level of environmental standards and encouraging environmental awareness, as a result of the following features: • Premium energy savings • RoHs compliancy • Extended life battery with ABC (Advanced Battery Care) Each UPS will be equipped with an ID card, including all UPS working parameters. This card, univocally related to the UPS, shortens UPS “off time” in the case where the control board needs to be replaced. Efficiency (%) 98 0 50 75 100 Percent load (%) Efficiency curve of the 80-NETMPR Using advanced battery care (ABC), the 80-NETMPR series will increase battery life by up to 50% and includes the following main battery care features: • Ambient temperature compensated battery charger • Automatic battery test (can be set by user at selectable intervals) • Time compensated end of discharge voltage • Exact determination of remaining battery life thanks to sophisticated algorithms able to analyze real operating conditions such as temperature, discharge and charging cycles and discharge depth. Interfaces Comunication 80-NETMPR like other Chloride three-phase UPS, features a standard 15 language graphic LCD display, allowing easy interaction with the UPS through the navigation menu design. In addition, the LCD display, complete with a combination key lock function, provides excellent security. The UPS is perfectly suitable for use in any building management system and offers the following standard communication features: • Voltage-free contact ports • Digital inputs • Two serial ports Hardware Connectivity ManageUPSNET includes a complete package, ensuring the monitoring and control of the networked UPS, through the TCP/IP protocol. It permits: • UPS monitoring from NMS via SNMP • UPS monitoring from PC via a Web browser • Dispatch of e-mail notifications Software Connectivity • Two internal slots (for LIFE.net card modem, ManageUPSNET cards, or others adaptors). • Possibility of integrating CHLORIDE UPS systems with Building Monitoring and Automation Systems via MODBUS RTU, MODBUS/TCP or JBUS protocols • Monitoring of environmental conditions where the UPS systems are installed. • MopUPS Professional • ManageUPS CIO The main function of MopUPS software will be the safe shutdown of the operating system in the event of an interruption to the load. MopUPS can also provide event logging and automatic communication of events through e-mail. ManageUPS CIO software provides a central management system for critical power infrastructures distributed within a building, campus or wide area network environment. LIFE.net remote diagnostic system compatible The 80-NETMPR family is fully compatible with LIFE.net, Chloride’s real-time UPS remote diagnostic tool. This service provides: • Continuous real-time monitoring of your UPS • Automatic transmission of a daily status report • Real-time diagnosis of all UPS operational parameters • A remote fix capability • Monthly UPS operational status report The LIFE cycle • Technical advice regarding the operation of your UPS • Detailed operational history of the full service LIFE of the UPS system • Unique ETS function for trouble shooting of the most common operating anomalies • Power Quality Monitoring to effectively monitor power disturbance trends • LIFE over the IP compatible, to enable the UPS to communicate with the Chloride LIFE centres using the internet. www.chloridepower.com 30 40 Apparent nominal output power at 25° C (kVA) 33 44 Apparent nominal output power at 40° C (kVA) 30 40 TECHNICAL CHARACTERISTICS INPUT Nominal primary mains input voltage/voltage range (V) 400 (300 to 460), three-phase + neutral Nominal bypass input voltage/voltage tolerance (V) 400 ± 10% (380V, 415V selectable) three-phase + neutral Nominal input frequency/frequency tolerance (Hz) 50 ± 10% (60Hz selectable) Input current distortion (THDi)* <3 Primary input Power Factor >0.99 OUTPUT Nominal output voltage (V) 400 (380V, 415V selectable) three-phase + neutral Output voltage stability by load variation 0 - 100% (%) static dynamic ±1 Complies with IEC/EN 62040-3,Class 1 Output frequency (nominal) (Hz) 50 (60Hz selectable) Output frequency variation (%) with mains synchronisation ± 1 (±0.2 to ±6 selectable) with internal reference Inverter overload capacity* Nominal output active power* Compatibility with loads ± 0.1 125% for 10 min, 150% for 1 min. 27 36 Any power factor (leading or lagging) up to 0.9 without output derating. Crest factor up to 3:1 Automatic adjustment of nominal output power with temperature 110% at 25°C, 100% at 40°C GENERAL Classification according to IEC/EN 62040-3 VFI - SS - 111 Operating temperature (°C) 0-40 Recommended battery temperature (°C) +15/+25 Relative humidity (without condensation at 20°C) <90% Protection level IP 21 Frame colour RAL 7016 Noise at 1 m (dBA)* <50 AC/AC efficiency (%)* up to 98% Parallel configuration up to 8 units DIMENSIONS AND WEIGHT Height (mm) 1600 Width (mm) 550 Depth (mm) 800 UPS weight without batteries (kg) * Conditions apply. 184 187 This publication is issued to provide outline information only and is not deemed to form any part of any offer and/or contract. The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary any information without prior notice. MKA4L0UK80MPR Rev. 1-09/2008 80-NETMPR Chloride Systems WORLD HEADQUARTERS Via Fornace 30 40023 Castel Guelfo (BO) Italy T +39 0542 632 111 F +39 0542 632 120 E [email protected] www.chloridepower.com Closest Chloride Contact in Australia: Chloride Australia Ground Floor 16 Giffnock Avenue, North Ryde NSW 2113 Australia Closest Chloride Contact in UAE: Chloride Middle East Building 5, Office 104 Dubai Internet City - Dubai UAE PO Box 72536 Closest Chloride Contact in South East Asia: CHLD Singapore Pte Ltd 2 Corporation Road #03-07 Corporation Place Singapore 618494 T +61 2 9888 1266 F +61 2 9888 1966 E [email protected] T +971 4 391 3205 F +971 4 391 6803 E [email protected] T +65 6481 4776 F +65 6481 0552 E [email protected] www.chloridepower.com.au www.chloridepower.com/middle-east www.chloridepower.com.sg Closest Chloride Contact in UK: Chloride UK George Curl Way Southampton, Hampshire SO18 2RY United Kingdom Closest Chloride Contact in USA: Chloride 27944 North Bradley Road Libertyville IL 60048 USA Closest Chloride Contact in Thailand: Chloride Thailand Panjathani Tower, 20th Floor 127/25 Nonsee Road , Chongnonsee, Yannawa, Bangkok 10120 Thailand T +44 (0) 23 8061 0311 F +44 (0) 23 8061 0852 E [email protected] T +1 847 816 6000 / +1 800 327 8801 F +1 847 680 5124 E [email protected] T +662 296 9800 F +662 681 0109 E [email protected] www.chloridepower.co.uk www.chloridepower.com/usa www.chloridepower.com/th Closest Chloride Contact in Vietnam: Chloride Vietnam Unit 1708, 17th Floor, Gemadept Tower 06 Le Thanh Ton Street, Ben Nghe Ward, District 1, Ho Chi Minh City Vietnam T +84 8 255 6737 F +84 8 255 6800 For a full list of contacts please visit our website at www.chloridepower.com Certificate No. EMS 76732 Certificate No. FM 11043 MKA4L0UK80MPR www.chloridepower.com/vn