Secure Power Always CROSS Chassis/Cabinet from 160 A to 1250 A STS Leaflet Secure Power Always CROSS Chassis/Cabinet from 160 A to 1250 A Chloride’s family of CROSS static switches are available in Cabinet versions from 160 to 1250 A and in both three and four pole versions (four pole from 160 A to 600 A only). CROSS Chassis is available in 160 to 450 A, in the four pole version only. CROSS ensures maximum reliability to critical loads by eliminating system failures that are caused by problems in distribution rather than from the failure of the power source itself. Flexibility Communication Applications CROSS can be fully customised according to for Customised Solutions An RS232 serial port and a voltage-free CROSS provides additional security for a customers’ load and environment requirements. contact port are available in standard wide range of mission critical applications Options include priority mode operation, assembly including: allowing users to select the preferred power communication source, selectable switching and tolerance protection equipment. features, galvanic isolation transformers, LED and LCD displays offer complete • Manufacturing Process Control tripping coil switches, RFI filters, top cable and • Signalling Systems entry connections and remote display units. equipment and provide detailed information • Safety Systems and Emergency Lighting on • Life Support Systems. Leading Technology versions easy the with interaction operational and facilitate installed power • Data centres /ISPs • Call Centres with status installed of your equipment. A key function of CROSS is the Break Before Secure Power Always Make transfer. This ensures that the two Remote Diagnosis Simply supplying equipment will never live feeds are never connected in parallel. The CROSS family is fully compatible with deliver the level of business continuity our The CROSS static switch also ensures that LIFE.net, Chloride’s remote diagnostic tool. customers require. Chloride offers a range switching between two power supplies LIFE.net is the nearest you can get to having of maintenance plans which will: occurs safely under both synchronous and a Chloride engineer permanently on site. • Help asynchronous conditions relative to input This service provides: • Extend the life of your power protection waveforms. • Continuous real-time monitoring of your power protection equipment • Automatic transmission of a daily status Reliability Employing a Chloride CROSS static switch adds another layer of security for mission critical loads. It ensures a report • Real-time diagnosis of all operational parameters deliver reliability to the load equipment • Optimise your capital expenditure • Provide risk management at a fixed cost • Help to control your business environment • Provide a pro active approach to disaster recovery. truly redundant power supply by enabling • A remote fix capability controlled switching between two independent • Monthly operational status report Contact your local Chloride sales officefor AC power supply sources. • Technical advice more information. • Detailed operational history of the full Switching is performed whenever the line that supplies power to the load goes out of tolerance. service LIFE of the CROSS system • Unique ETS function for trouble-shooting Distribution downstream from CROSS is not of the most common operating anomalies only protected from failure of the power sources, • Power Quality Monitoring to effectively but also against any failure in upstream lines. monitor power disturbance trends. Delegate your to the experts. power management CROSS Chassis (A) TECHNICAL DATA Default Input Voltage (V) Nominal frequency (Hz) Input phases Number of poles Transfer Mode (for Phases) Overload capacity (without fuses) for 10 minutes (%) for 1 minute (%) for 10 seconds (%) for 1 second (A) Neutral Transfer Mode Transfer Time source failure (msec) Static Switch Fault detector Ventilation Neutral sized DIMENSIONS AND WEIGHT Dimensions (mm): 160 3-4 250 400 600 800 400 50/60 3 +N 3-4 3-4 3-4 3 Break Before Make Switching (No source overlap) 5300 5300 Configurable Configurable Natural 2 Natural 2 125 150 200 5300 5300 < _5 Configurable Configurable Yes Natural Natural 1.7 1.3 1250 3 5300 9200 - - Forced 1.7 Forced 1.7 620 620 830 830 1780 1780 Integrated in main CROSS Cabinet module 820 830 1780 1220 830 1780 1020 830 1780 820 830 1780 1220 830 1780 1220 830 1780 450 450 570 590 275 350 547 696 <45 CE marking, IEC EN 62310-1 IEC EN 62040-2 Class C2 IP20 0-40 <45 <45 <65 <65 <45 160 250 450 400 50/60 3 +N 4 Break Before Make Switching (No source overlap) 125 150 200 5300 Configurable < _5 Yes Natural 1.7In W D H Weight (kg): ENVIRONMENT AND STANDARDS Safety EMC Compatibility Degree of Protection Operating temperature (°C) Acoustic noise (dBA) 700 600 1200 135 150 160 IEC EN 62310-1 if used inside an appropriate hosting cubicle IEC EN 62040-2 Class C2 IP00 0-40 <45 The CROSS Chassis may differ from the one displayed in the front cover. www.chloridepower.com This publication is issued to provide outline information only and is not deemed to form any part of any offer and/or contract. The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary any information without prior notice. MKA4L0UKCROSS Rev. 9-11/2008 CROSS Cabinet (A) TECHNICAL DATA Default Input Voltage (V) Nominal frequency (Hz) [selectable] Input phases Number of poles Transfer Mode Overload capacity for 10 minutes (%) for 1 minute (%) for 10 seconds (%) for 1 second (A) Transfer Time source failure (msec) Neutral Transfer Mode (4-Pole only) Static Switch Fault detector Ventilation Neutral sized DIMENSIONS AND WEIGHT Dimensions (mm): Main CROSS Cabinet Module: W D H Switch module: W D H Weight (kg): Main CROSS Cabinet Module: Switch module: ENVIRONMENT AND STANDARDS Safety EMC Compatibility Degree of Protection Operating temperature (°C) Acoustic noise (dBA) Chloride Systems WORLD HEADQUARTERS Via Fornace 30 40023 Castel Guelfo (BO) Italy T +39 0542 632 111 F +39 0542 632 120 E [email protected] www.chloridepower.com Closest Chloride Contact in Australia: Chloride Australia Ground Floor 16 Giffnock Avenue, North Ryde NSW 2113 Australia Closest Chloride Contact in UAE: Chloride Middle East Building 5, Office 104 Dubai Internet City - Dubai UAE PO Box 72536 Closest Chloride Contact in South East Asia: CHLD Singapore Pte Ltd 2 Corporation Road #03-07 Corporation Place Singapore 618494 T +61 2 9888 1266 F +61 2 9888 1966 E [email protected] T +971 4 391 3205 F +971 4 391 6803 E [email protected] T +65 6481 4776 F +65 6481 0552 E [email protected] www.chloridepower.com.au www.chloridepower.com/middle-east www.chloridepower.com.sg Closest Chloride Contact in UK: Chloride UK George Curl Way Southampton, Hampshire SO18 2RY United Kingdom Closest Chloride Contact in USA: Chloride 27944 North Bradley Road Libertyville IL 60048 USA Closest Chloride Contact in Thailand: Chloride Thailand Panjathani Tower, 20th Floor 127/25 Nonsee Road , Chongnonsee, Yannawa, Bangkok 10120 Thailand T +44 (0) 23 8061 0311 F +44 (0) 23 8061 0852 E [email protected] T +1 847 816 6000 / +1 800 327 8801 F +1 847 680 5124 E [email protected] T +662 296 9800 F +662 681 0109 E [email protected] www.chloridepower.co.uk www.chloridepower.com/usa www.chloridepower.com/th Closest Chloride Contact in Vietnam: Chloride Vietnam Unit 1708, 17th Floor, Gemadept Tower 06 Le Thanh Ton Street, Ben Nghe Ward, District 1, Ho Chi Minh City Vietnam T +84 8 255 6737 F +84 8 255 6800 For a full list of contacts please visit our website at www.chloridepower.com Certificate No. EMS 76732 Certificate No. FM 11043 MKA4L0UKCROSS www.chloridepower.com/vn