Liebert PBX+ UPS (5 kVA)

AC Power Systems
for Business-Critical Continuity
Liebert PBX+ UPS (5 kVA)
Mini Online UPS - Liebert PBX+ 5kVA
• Reliability
- Double conversion online design
- DSP full digital controlwith high output precision
- Can withstand fluctuationof input mains voltage
• Energy Efficiency & Low TCO
- Good Energy saving performance
Applications :
-
Input power factor greater than 0.99*
B a n k i n g , S er ver, Sto r a g e d ev i ce, N et wo r k
instruments,VOIP, communication equipment,
precision instrument and PC Banking.
Applicable load :
Small IDC room, Network room,Business operating
room, lab and instrument room.
• High Serviceability
- Main machine is separate from Battery.
-
Provide LCD, each kind of status / Fault information is visible.
• Real Time Monitoring
-
SNMP card to acquire UPS data and event.
• Better battery life
- Wide Input voltge / frequency reduces discharging time.
Product Features
 Output Isolation transformer
 Auto transfer facility
 DSP based true online UPS system
 Compatible with Engine generator
 Less foot print.
 Technology - IGBT based.
-
Extra strong charging capacity
-
Main machine is separate from battery,which is good for battery
life.
TM
Technical Specifications
Liebert PBX+ 5kVA (4.5kW)
Input Parameters
Nominal input voltage
Permissible input voltage range
Nominal Input frequency
Permissible input frequency variation
Input power factor
Input Current Distortion - I - THD
Generator rating (kVA)
Intermediate DC circuit parameters
Nominal DC voltage at input of inverter
Inverter DC bus Overvoltage trip
Nominal Battery float voltage
Types of batteries supported
End of discharge Battery bus voltage
230 Vac 1-Phase Line to neutral with 3-wire system (Earth wire)
161 Vac (-30%) to 276 Vac (+20%)
50 Hz
+/- 10%
> 0.99 at 230 Vac input voltage and 4.5kW output load & V i/pTHD < 2%
<= 10% at 230 Vac input voltage , 4.5kW output load & Vi/pTHD < 2%
20 kVA (Single Phase)
790 Vdc
850 Vdc
270V (2.25V / Cell) for SMF
256V (2.24V / Cell) for LATB
VRLA / SMF, LATB
SMF: 1.75V / Cell (210 Vdc for 20 Blocks)
LATB: 1.8 V/Cell (205 for 19 Blocks)
Maximum battery charging current
(with full o/p Power of 4.5kW)
10A - (for input voltage between 207V to 276V)
6.5A - (For input voltage between 185 to 206V)
5A - (For input voltage between 161 to 184C)
DC ripple
Maximum Battery back up time
Black Start
No. of batteries (12V)
Charging Time (to reach 90% of AH)
Battery Capacity (Adjustable)
<1% rms, <=2% peak to peak
Up to 4 hours.
Available
20 nos. - SMF, 19 nos. - LATB
12 Hrs to 15 Hrs.
7AH, 12AH, 18AH, 24AH, 40AH, 65AH, 100AH
Output Parameters
Output power
Output power factor
Nominal output voltage
Output voltage regulation
Output voltage distortion for 100% load
Nominal output frequency
Output frequency tolerance in free run mode
Output frequency synchronisation range
Output crest factor capacity
Transient response at 100% step load
Inverter to bypass Load transfer time
Overload capacity
UPS efficiency for 100% Linear load (AC-AC, with
Battery on Float mode) at Nominal I/P voltage
UPS efficiency for 50% Linear load (AC-AC, with
Battery on Float mode) at Nominal I/P voltage
On Battery Mode Efficiency at 100% Linear load
Bypass Parameters
Permissible Bypass voltage Range
Permissible Bypass Freq. Range
Mechanical parameters
Protection grade
Ventilation
Cable entry
Colour / Panel finish
Sheet metal thickness
Height
Depth
Width
Weight
Environmental parameters
Operating temperature range
Storage temperature
Relative humidity
Maximum altitude with full rating
Altitude de-rating
Acoustic noise with rated load at 1 meter
Altitude de-rating
Manual Bypass Switch : Optional
Communication - Optional
Remote parameter monitoring (HTTP) using OCWEB card:
*Set o/p voltage either 220V, 230V or 240V
5kVA / 4.5kW for entire AC I/P range
0.9 Lagging
230 VAC
+/- 2%
<=3% on linear
<=5% on non linear
50 Hz
+/- 0.5 Hz
47 Hz to 53 Hz
3:1
40% peak recovering to 2% within 2ms
<10ms
Emerson Network Power.
The global leader in enabling business-critical continuity.
105 - 130% overload for 10 minutes
130 - 150% overload for 10 secs.
150% overload for <100msec
83%
80%
81%
- 20% / + 10% of set O/P voltage*
47 Hz to 53 Hz
IP 20
Forced - Air cooled (Air entry at front UPS)
Back end - TOP
Dark structured grey
Nominally 1.6mm, 2mm as required at stress points
Without Castor Wheels : 375 mm
With Castor Wheels : 434 mm
706 mm
445 mm (19”)
88 Kg max
0°C to 40°C
-10°C to 70°C
0-95% RH Non-Condensing
1000 Meters
1% per100m between 1000m & 2000m
<= 65 dBA
1% per 100m between 1000m & 2000m
While every precaution has been taken to ensure
accuracy and completeness in this brochure, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or ommissions.
Emerson Network power and the Emerson Network
Power logo are trademarks and service marks of
Emerson Electric Co. © 2010 Emerson Electric Co.