AC Power Systems for Business-Critical Continuity Liebert PBX+ UPS (5 kVA) Mini Online UPS - Liebert PBX+ 5kVA • Reliability - Double conversion online design - DSP full digital controlwith high output precision - Can withstand fluctuationof input mains voltage • Energy Efficiency & Low TCO - Good Energy saving performance Applications : - Input power factor greater than 0.99* B a n k i n g , S er ver, Sto r a g e d ev i ce, N et wo r k instruments,VOIP, communication equipment, precision instrument and PC Banking. Applicable load : Small IDC room, Network room,Business operating room, lab and instrument room. • High Serviceability - Main machine is separate from Battery. - Provide LCD, each kind of status / Fault information is visible. • Real Time Monitoring - SNMP card to acquire UPS data and event. • Better battery life - Wide Input voltge / frequency reduces discharging time. Product Features Output Isolation transformer Auto transfer facility DSP based true online UPS system Compatible with Engine generator Less foot print. Technology - IGBT based. - Extra strong charging capacity - Main machine is separate from battery,which is good for battery life. TM Technical Specifications Liebert PBX+ 5kVA (4.5kW) Input Parameters Nominal input voltage Permissible input voltage range Nominal Input frequency Permissible input frequency variation Input power factor Input Current Distortion - I - THD Generator rating (kVA) Intermediate DC circuit parameters Nominal DC voltage at input of inverter Inverter DC bus Overvoltage trip Nominal Battery float voltage Types of batteries supported End of discharge Battery bus voltage 230 Vac 1-Phase Line to neutral with 3-wire system (Earth wire) 161 Vac (-30%) to 276 Vac (+20%) 50 Hz +/- 10% > 0.99 at 230 Vac input voltage and 4.5kW output load & V i/pTHD < 2% <= 10% at 230 Vac input voltage , 4.5kW output load & Vi/pTHD < 2% 20 kVA (Single Phase) 790 Vdc 850 Vdc 270V (2.25V / Cell) for SMF 256V (2.24V / Cell) for LATB VRLA / SMF, LATB SMF: 1.75V / Cell (210 Vdc for 20 Blocks) LATB: 1.8 V/Cell (205 for 19 Blocks) Maximum battery charging current (with full o/p Power of 4.5kW) 10A - (for input voltage between 207V to 276V) 6.5A - (For input voltage between 185 to 206V) 5A - (For input voltage between 161 to 184C) DC ripple Maximum Battery back up time Black Start No. of batteries (12V) Charging Time (to reach 90% of AH) Battery Capacity (Adjustable) <1% rms, <=2% peak to peak Up to 4 hours. Available 20 nos. - SMF, 19 nos. - LATB 12 Hrs to 15 Hrs. 7AH, 12AH, 18AH, 24AH, 40AH, 65AH, 100AH Output Parameters Output power Output power factor Nominal output voltage Output voltage regulation Output voltage distortion for 100% load Nominal output frequency Output frequency tolerance in free run mode Output frequency synchronisation range Output crest factor capacity Transient response at 100% step load Inverter to bypass Load transfer time Overload capacity UPS efficiency for 100% Linear load (AC-AC, with Battery on Float mode) at Nominal I/P voltage UPS efficiency for 50% Linear load (AC-AC, with Battery on Float mode) at Nominal I/P voltage On Battery Mode Efficiency at 100% Linear load Bypass Parameters Permissible Bypass voltage Range Permissible Bypass Freq. Range Mechanical parameters Protection grade Ventilation Cable entry Colour / Panel finish Sheet metal thickness Height Depth Width Weight Environmental parameters Operating temperature range Storage temperature Relative humidity Maximum altitude with full rating Altitude de-rating Acoustic noise with rated load at 1 meter Altitude de-rating Manual Bypass Switch : Optional Communication - Optional Remote parameter monitoring (HTTP) using OCWEB card: *Set o/p voltage either 220V, 230V or 240V 5kVA / 4.5kW for entire AC I/P range 0.9 Lagging 230 VAC +/- 2% <=3% on linear <=5% on non linear 50 Hz +/- 0.5 Hz 47 Hz to 53 Hz 3:1 40% peak recovering to 2% within 2ms <10ms Emerson Network Power. The global leader in enabling business-critical continuity. 105 - 130% overload for 10 minutes 130 - 150% overload for 10 secs. 150% overload for <100msec 83% 80% 81% - 20% / + 10% of set O/P voltage* 47 Hz to 53 Hz IP 20 Forced - Air cooled (Air entry at front UPS) Back end - TOP Dark structured grey Nominally 1.6mm, 2mm as required at stress points Without Castor Wheels : 375 mm With Castor Wheels : 434 mm 706 mm 445 mm (19”) 88 Kg max 0°C to 40°C -10°C to 70°C 0-95% RH Non-Condensing 1000 Meters 1% per100m between 1000m & 2000m <= 65 dBA 1% per 100m between 1000m & 2000m While every precaution has been taken to ensure accuracy and completeness in this brochure, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or ommissions. Emerson Network power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2010 Emerson Electric Co.