Power Switching & Controls For Business-Critical ContinuityTM Grid to Chip Surge Protection Product Catalog Contact Surge Protection 100 Emerson Parkway Binghamton, NY 13905 T: 607-721-8840 (Outside U.S.) T: 800-288-6169 (U.S. & Canada Only) F: 607-722-8713 E: [email protected] Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. EmersonNetworkPower. com/surge AC Power Embedded Computing Infrastructure Management & Monitoring Thermal Management Connectivity DC Power Embedded Power Industrial Power Outside Plant Power Switching & Controls Racks & Integrated Cabinents Service Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2014 Emerson Electric Co. While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. SL-30900 Rev.3 1/14 Printed in USA Power Quality Solutions for ALL Your Application Needs “Dirty” power is a problem. Whether it’s called a surge, spike, transient or noise, “dirty” power is an abnormality in the power that runs your facility. These power problems can leave buildings in the dark and disable equipment, costing you thousands in repairs and lost revenue. Your productivity uptime and reputation depend on consistent power quality. Emerson Network Power Surge Protection provides products and solutions that ensure reliability from Grid to Chip. For more than 40 years, Facility Managers, Engineers, and System Integrators have trusted Emerson Network Power Surge Protection products to protect critical equipment in the Industrial Process, Computing, Research/Testing and Communications fields. Emerson Network Power Surge Protection and the IEEE Standard 1100-1999 (Emerald Book) recommend a properly rated surge protection device should be applied on ALL electrical conductors entering your facility including: power, voice, and data. Without proper protection – data disruption, hardware stress or destruction could occur. As a line of defense against damaging transients, Emerson Network Power Surge Protection manufactures products in the following categories: ■ Surge Protection Devices (SPDs) — which focus on limiting high-voltage spikes to an acceptable level ■ Filtering/Line Conditioning — protect against low-energy transients and high frequency noise and finally… ■ Data/Signal Line Protection — products guard sensitive instrumentation against what we refer to as ‘backdoor’ transients and noise. Why allow “dirty” power to put your equipment at risk? Turn to Emerson Network Power Surge Protection products for peace of mind. We provide solutions for all your application needs and the foundation for Business-Critical Continuity™. Table of Contents Technical Bulletins — Surge Protection for Power and Signal Lines Products Page # TVSS/SURGE PROTECTION DEVICES (SPDs) TVSS/SPDs — Product Selection Guide Emerson Network Power DRS Series Edco EMC-240B — Low Exposure AC Panel Protection Edco FAS-120AC — Medium Exposure AC Panel Protection 2 3 4 4 FILTERING/LINE CONDITIONING TM Filtering/Line Conditioning — Product Selection Guide Islatrol™ IE Series — Active Tracking Filter™ Islatrol™ IC+/LRIC+ Series — Active Tracking Filter™ Islatrol™ — SP-6TVN — Industrial Strength Surge Suppression (Series) Islatrol™ — RM Series — 120 VAC Rackmount TM 5 6, 7 8, 9 10 11 DATA/SIGNAL LINE PROTECTION TM TM Data/Signal Line Protection — Product Selection Guide Edco™ DRS (DC) Series — DIN Rail Protection Edco™ PC642 Series — Zone/Loop/Data Edco™ PHC Series — Two-Pair Signaling Circuit Protector (Modular) Edco™ RJA-RJD Series — RJ-45 Telephone/Data Edco™ RM-CAT6-16POE — CAT6-16POE Channel Rackmount Edco™ CX-HFN-FF/CX-HFN-FM — High Frequency Line Protector — N-Type Edco™ SLAC Series — AC Power/Signal Edco™ SS64 & SS65 Series — Wastewater/Industrial Applications Edco™ CX Series — CCTV & Data Applications/Coax Edco™ RM-CXO6-16R — Channel Rackmount Edco™ CAT6-5 POE Series TECHNICAL BULLETINS High-Density Multiple Input Rack Surge Protection for the Water Industry Surge Protection for Power and Signal Lines Note: Refer to EmersonNetworkPower.com/surge for most current product information. NOTES: 1. SLAC UNIT PROVIDES ONE POWER AND TWO SIGNAL PROTECTION CIRCUITS. 2. SURGE DEVICES SHOULD BE GROUNDED LOCALLY WITH A GROUND ROD, AND ALSO AT THE MAIN PANEL ELECTRICAL GROUND. 3. CHECK WITH EMERSON NETWORK POWER SURGE PROTECTION, INC. TO DETERMINE IF OUTPUT CAN BE SURGE PROTECTED. 24 12 13 14 15 16 17 17 18 19 20 20 21 22 23 24 Technical Bulletins TVSS/Surge Protective Devices (SPDs) TVSS/SPDs — Product Selection Guide Technical Bulletins — Surge Protection for the Water Industry Find your application in the left column. Then look across for the appropriate product (s). PRODUCTS APPLICATIONS DRS Series TM Edco EMC Series Edco FAS Series TM Facility Service Entrance Distribution Panels TM TM Sub-Distribution Panels Branch Panelboards (Commercial) TM Branch Panelboards (Residential) Motor Control Centers Control Panels (AC Power) NOTES: 1. SLAC UNIT PROVIDES ONE POWER AND TWO SIGNAL PROTECTION CIRCUITS. Various OEM Equipment 2 2. SURGE DEVICES SHOULD BE GROUNDED LOCALLY WITH A GROUND ROD, AND ALSO AT THE MAIN PANEL ELECTRICAL GROUND. 3. CHECK WITH EMERSON NETWORK POWER SURGE PROTECTION, INC. TO DETERMINE IF OUTPUT CAN BE SURGE PROTECTED. 23 Technical Bulletins TVSS/Surge Protective Devices (SPDs) DRS Series Technical Bulletins — High-Density Multiple Input Rack The DRS is a modular surge protective device (SPD) that is designed for easy installation in control panels using standard DIN rail mounting brackets. The DRS devices offer both normal and common surge protection up to 40 kA per phase. Features ■ Effectively handles high-energy transients on TT, TN-C, TN-S and TN-C-S three-phase power systems ■ SPD rated Type 2 in accordance with EN 61643-11; Class I & II in accordance with IEC 61643-1 ■ Built-in thermal components disconnect SPD from the power source to avoid thermal runaway conditions ■ MOV only or MOV+Gas Tube models available ■ Fast response time, high surge current capability, low voltage protection levels ■ Visual inspection window on each module indicates status ■ 3-pole terminal provides remote status monitoring ■ DIN rail mounting and plug-in module design allow for easy installation, maintenance and replacement of surge element ■ 5 year warranty TM How to Specify the Appropriate Model Example: DRS 120 3 1 Q Nominal Voltage (Un) (XXX) # of Metal Oxide Varistor Modules* (X) # of Gas Tube Modules** (X) 120 0 0 230 1 1 240 2 277 3 346 4 TM Q *MOV modules are typically one module per phase and may be wired L-N, L-G or N-G. **Gas Tube modules typically used in the N-G mode for type TT grounding systems. ***Certain applications require higher rated components in order to survive frequent voltage rises, in this case order a unit with a “Q” at the end of the part number. 480 TM Higher Rated Voltage*** (Optional) Replacement modules available: Order DRS + Un + M (for MOV) or G (for Gas Tube) TM Performance Technical Specifications DRS12031 TM System Voltage Type of Network DRS27731 DRS34631 120/208, 230/400, 220/380, 277/480, 127/220 VAC 240/415 VAC 254/440 VAC TT-TN TT-TN TT-TN L-N; N-PE L-N; N-PE L-N; N-PE Nominal Voltage Un–120 V Un–230 V Un–277 V Un–346 V Rated Voltage (MCOV) Uc–150 V Uc–320 V Uc–320 V Uc–420 V 1. SLAC UNIT PROVIDES ONE POWER AND TWO SIGNAL PROTECTION CIRCUITS. Nominal Discharge Current (8 x 20 µs) 1n–20 kA 2. SURGE DEVICES SHOULD BE GROUNDED LOCALLY WITH A GROUND ROD, AND ALSO AT THE MAIN PANEL ELECTRICAL GROUND. Maximum Discharge Current Imax–40 kA 3. CHECK WITH EMERSON NETWORK POWER SURGE PROTECTION, INC. TO DETERMINE IF OUTPUT CAN BE SURGE PROTECTED. TT-TN 346/600 VAC Modes of Protection L-N; N-PE NOTES: 1n–20 kA Imax–40 kA Up–1.6 kV 1n–20 kA Imax–40 kA Up—1.6 kV 1n–20 kA Imax–40 kA Up–1.2 kV Response Time TS–25 ns TS–25 ns TS–25 ns TS–25 ns 95% 95% 95% 95% > 103 MV > 103 MV > 103 MV > 103 MV Isolation Resistance Test Standards EN 61643-11 Type 2 IEC61643- 1:1998-02 Class II Mechanical Characteristics Dimensions (Length x Width x Height) 70.8mm x 90.5mm x 68mm I/O Connections By Screw Terminal: 4-25 mm2 By Connection Bus MOV Encapsulation Material Disconnection Indicator Voltage Protection Level Relative Humidity 22 DRS23031 Electrical Characteristics Up–2.0 kV Status Monitoring Mounting Operation Temperature Range Degree of Protection Disconnection Device Housing Material Epoxy Resin Mechanical Indicator Remote Alarm Terminals Symmetrical Rail (EN50022/DIN46277-3) -40°C to +85°C IP 20 Thermal Cutoff System ABS/PA UL94V0 3 TVSS/Surge Protective Devices (SPDs) Data/Signal Line Protection Edco EMC-240B 120/240 VAC Low Exposure AC Panel Protection Edco™ CAT6-5POE Series The Edco EMC-240B surge suppressor is designed to protect AC distribution panel circuits or 120V power supplies feeding sensitive electronic equipment. CAT6/CAT5 Power Over Ethernet Electrically, the unit incorporates MOV and thermal fusing technology. The Edco The Edco™ CAT6-5POE Series is designed to work on Category 5 Power-Over- EMC 240B is designed to be installed in parallel on standard single phase Ethernet transmission lines as well as Category 6 applications. Ideal to protect 120VAC (L,N,G) circuits. expensive equipment against surges and transients entering a building on exposed transmission lines. Features ■ Fast response time ■ Operational status indicators ■ 40,000 Amps per phase capacity ■ UL 1449 Third Edition, Type 2 listed ■ Failsafe and fused ■ 5 year warranty General Technical Specifications Operating Voltage 120/240 VAC VPR L-N:600V, L-L:1,200V Fault Current Rating 42 kAIC UL Location Type 2 I-Nominal (kA) Total Peak Surge Current ■ Applications up to 60 VDC @ 300 mA ■ Exceeds CAT5 & 6 transmission values ■ 1 year warranty ■ CAT5 POE compatible Operating Frequency 47-63 Hz EMI Attenuation (100 kHz to 100 MHz) SPD Technology > 40 dB Metal Oxide Varistors (MOVs) Modes of Protection Line-to-Line, Line-to-Neutral 3kA Operating Current Features Operating Temperature Dimensions (Inches) -40°C to +85°C Weight Certifications ■ CAT6 compatible 4.6H x 2.2W x 2.8L 13.5 oz ANSI/UL 1449 Third Edition Type 2, CUL General Technical Specifications Ordering Information NA, Parallel Status Indication Power On & MOVs functional Operating Voltage 60 VDC Connection Type 80 kA (8 x 20 µs) Connection Type Wire Leads Clamping Voltage 65 VDC Operating Temperature Operating Current 300 mA Dimensions (Inches) Peak Surge Current Edco FAS-120AC ™ Frequency Range Insertion Loss 120 VAC Medium Exposure AC Panel Protection SPD Technology 60A (10 x 1000 µs) Weight RJ-45 Jacks RJ-45 (Female-Female) CAT6-5POE-FF -40°C to +85°C 0.8H x 1.0W x 2.3L 1 oz 0 to 250 MHz < 0.1 dB at 20 MHz Silicon Avalanche Diode (SAD) The Edco FAS-120AC surge suppressor is designed to protect AC panel circuits or 120V power supplies feeding sensitive electronic equipment. Electrically the unit incorporates MOV and thermal fusing technology. This device is designed to be installed in parallel on standard single phase 120VAC (L,N,G) circuits. Installation can be close-nipple up to a distribution panel/circuit or hardwired in parallel up to power supply input terminal screws. Be sure to dress leads as short as possible. Features ■ LED indicator ■ Compact size ■ Fast response time ■ Liquid tight conduit fitting ■ Thermal fuse ■ 5 year warranty ■ L-G, L-N, & N-G protection General Technical Specifications Operating Voltage VPR 120 VAC L-N:700V, L-G:700V, N-G:700V UL Location I-Nominal Operating Current Total Peak Surge Current Operating Frequency 4 Type 2 3 kA EMI Attenuation (100 kHz to 100 MHz) SPD Technology Modes of Protection Line-to-Neutral, Dimensions (Inches) Weight Certifications 2.5H x 1.5W x 3.0L 4.2 oz ANSI/UL 1449 Third Edition Line-to-Ground, Neutral-to-Ground NA, Parallel Status Indication 15.5 kA (8 x 20 µs) Connection Type 47-63 Hz > 25 dB Metal Oxide Varistors (MOVs) Power On & MOV Functional Operating Temperature Wire Leads -40°C to +85°C 21 Data/Signal Line Protection Filtering/Line Conditioning Edco™ CX Series CCTV & Data Applications/Coax The Edco™ CX06-M & Edco™ CX06-MI Surge Protective Devices (SPDs) implement three-stage hybrid technology. The SPDs address over-voltage transients with a primary Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD) components. Over-current protection, e.g. sneak and Filtering/Line Conditioning — Product Selection Guide Find your application in the left column. Then look across for the appropriate product. fault currents, are mitigated with solid-state resettable fuses — PTCs. The Edco™ CX06-M & Edco™ CX06-MI SPDs are designed in accordance with NFPA 780 PRODUCTS (2004 edition) requirements, with up to 20 kA of surge current capability. The Edco™ CX06-MI model has an isolated ground and is recommended for use at the camera end. APPLICATIONS Features ■ Sneak/fault current protection ■ CX06-MI has an isolated ground ■ Low insertion loss ■ 5 year warranty Islatrol™ IE Series Islatrol™ IC+/LRIC+ Series Islatrol™ SP-6TVN Series Islatrol™ RM Series ■ Shielded case General Technical Specifications Operating Voltage Ordering Information 5 VDC Connection Type Clamping Voltage 6 VDC Operating Temperature Operating Current 0.15 A Dimensions (Inches) Peak Surge Current Frequency Range Insertion Loss SPD Technology 20 kA (8 x 20 µs) 0 to 20MHz < 0.1 dB at 20 MHz Programmable Logic Controllers Weight BNC, 50/75 Ohm Head End -40°C to +85°C Camera End CX06-MI M = 1.5H x 1W x 3.25L MI = 1.5H x 1W x 4L Camera End CX06-MI-SBL M = 2.3 oz Certifications * CX06-M MI = 3 oz UL 497B Control Panels (AC Power) * * Various OEM Equipment * * GDT, SAD, w/Series PTC Edco™ RM-CX06-16R Channel Rackmount The Edco™ RM-CX06-16R Surge Protective Device (SPD) is a 16 channel coax SPD implementing three-stage hybrid technology. The SPD addresses overvoltage transients with a primary Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD) components. Over-current protection, e.g., sneak and fault currents, are mitigated with new solid-state resettable fuses — PTCs. The Edco™ RM-CX06-16R SPD is designed in accordance with NFPA 780 (2004 edition) requirements, with up to 20 kA of surge current capability. Home Entertainment/Office * Features ■ Sneak/fault current protection ■ 16 channel ■ Low insertion loss ■ 1 year warranty ■ Shielded case AC Rack Equipment General Technical Specifications Operating Voltage 5 VDC Frequency Range Clamping Voltage 6 VDC Insertion Loss Operating Current 0.15 A SPD Technology Peak Surge Current 20 20 kA (8 x 20 µs) Connection Type 0 to 100 MHz < 0.1 dB at 20 MHz GDT, SAD, w/Series PTC BNC, 50/75 Ohm Operating Temperature Dimensions (Inches) Weight Certifications -40°C to +85°C 1.75H x 19W x 2.0D (1U) 3.2 lbs UL 497B 5 Filtering/Line Conditioning Data/Signal Line Protection Islatrol™ IE Series Edco™ SS64 & SS65 Series Active Tracking Filter™ Wastewater/Industrial Applications The Islatrol IE is a series-connected DIN or flange mounted high- The Edco™ SS64 and Edco™ SS65 Series suppressors are designed for the water frequency noise filter and surge suppressor. Its ideal applications include and wastewater industry. These multi-stage hybrid suppressors address critical industrial loads drawing up to 20 Amps of continuous current, over-voltage transients with gas tube and silicon avalanche technology. In while typical applications include any microprocessor-based products, addition, sneak and fault currents are mitigated with PTC devices which including industrial PLCs, OEM applications, and motion control systems. consist of solid-state resettable fuses. The units are encapsulated in stainless ™ steel pipe nipples making them suitable for use in severe environments. The Edco™ SS64 models protect a signal pair and the Edco™ SS65 models protect a Features ■ Multi-staged design, combining a unique hybrid clamping network with the active tracking technology of the Islatrol ® family ■ Surge current capacity — 45,000 Amps ■ Transient protection in all modes: line to neutral, line to ground, and neutral to ground signal pair plus the cable shield (drain wire). ■ LED status indication and form C contact for remote indication ■ DIN mountable enclosure ■ ANSI/UL 1449 Third Edition Type 4, 1283, CUL recognized, CE Features ■ 10 year warranty ■ Transient protection for low-voltage signal lines ■ Encapsulated in stainless steel pipe nipples ■ Sneak/fault current protection ■ Protection for one pair (Two wires & shield on SS65) ■ Resettable fusing—PTCs Performance Technical Specifications General Technical Specifications Ordering Information Model Voltage* IE-103 IE-105 IE-110 IE-120 L-N 400V 400V IE-203 IE-205 IE-210 IE-220 L-G 600V 600V N-G L-L 600V N/A 500V N/A MCOV 700V 900V 700V Peak Surge Current Capability (8 x 20 µs) 5 Amps IE-105 120 V 10 Amps IE-110 120 V 20 Amps IE-120 Continuous Current Model 275 VRMS Line Frequency 47 - 63 Hz Terminal Mounting Type DIN/Flange Weight < 3 lbs Voltage* 3 Amps IE-203 Response Time Normal Mode < 0.5 ns 240 V 5 Amps IE-205 Maximum Signal Voltage 28 V Max < 5 ns 240 V 10 Amps IE-210 DC Clamping Level (L-G) 36 V ±l0% -40°C to +45°C 240 V 20 Amps IE-220 DC Clamping Level (L-L) 72 V ±l0% Operating Temperature Derate Linearly to 60% at +70ºC Operating Humidity * All voltage configurations are single phase - 2 wire + gnd. Common Mode 100 kHz to 50 MHz - 90 dB Min 5 MHz to 50 MHz - 60 dB Min Maximum let-thru Voltage: Dimensional Diagram Line-to-Line (10x700 µs) Normal Mode/Common Mode (Zero Volts Bias) 5 Amp 0.7 V/292 V 10 Amp 0.7 V/300 V 20 Amp 0.7 V/300 V 90 V @ 400 A Series Resistance (per conductor) Typical Category A Ringwave (6 kV, 200 A, 100 kHz) 1 V/300 V 44 V @ 400 A Maximum let-thru Voltage: Capacitance: 3 Amp Typical Applications < 1 Nanosecond Line-to-Ground (10x700 µs) 0% to 95% Frequency Response (Forward-Reverse) Normal Mode General Technical Specifications 240 V Common Mode ■ 5 year warranty ■ Automatic recovery Response Time 15,000 Amps 15,000 Amps 120 V 240 Volt 15,000 Amps 45,000 Amps IE-103 120 V Line to Ground Total Model 3 Amps 150 VRMS Line to Neutral Neutral to Ground Continuous Current 120 Volt Connection 1,000V ■ Differential and common mode protection Number of Occurrences 5 V (typical) (L-L) 600 pf typical (L-G) 1200 pf typical 400 @ 500 Amps (10x1000 µs) Typical Category B Ringwave (6 kV, 500 A, 100 kHz) Normal Mode/Common Mode 6 3 Amp 178 V/300 V 5 Amp 162 V/291 V 10 Amp 153 V/300 V 20 Amp 200 V/300 V Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal lines capable of supplying more than 150 milliamperes continuously. 19 Data/Signal Line Protection Filtering/Line Conditioning Edco™ SLAC Series Islatrol™ IE Series AC Power/Signal Active Tracking Filter™ The Edco SLAC Series suppressor is specifically designed to protect electronic ™ instruments used by the water/wastewater industries. It combines hybrid AC power protection and signal line protection in a NEMA-4X polycarbonate case. System Design The AC power suppressor can supply up to 1875 Watts and has a 15 Amp replaceable fuse to prevent overloading of the protective elements. A “Power ON” LED provides visual indication that power is applied to instruments. Signal line protection is accomplished by the Edco™ PC642 Series available in a variety of voltage clamps. Signal current can be monitored by reading the voltage Shunt Absorbing Components line side sine wave tracking circuitry Shunt Absorbing Components load side sine wave tracking circuitry across the 10 V, 1% resistors (TP1 & TP2 or TP3 & TP4). All leads going to the Edco™ SLAC board are terminated by quick disconnect or barrier block Finger Safe Terminals IEC 998 approved terminals connectors to facilitate easy removal for service or replacement. Form C Relay Contacts normally open and normally closed dry contact for remote status monitoring Features ■ Optional twist lock plug lightning & surge suppression for AC power and low-voltage signal lines ■ Test jacks for signal line monitoring ■ Series hybrid AC suppressor/filter ■ Optional stainless steel or fiberglass enclosure ■ Plug-in protection module ■ 15 Amp replaceable fuse General Technical Specifications AC Power Technology Three-Stage Series Hybrid Input Voltage 15 Amps Max. Response Time <5 Nanoseconds Maximum Surge Current (8x20 µs) Normal Mode (L-N) ■ 5 year warranty MOV Array high-energy surge current diversion array providing transient protection line to neutral, line to ground, and neutral to ground Silicon Avalanche Diodes fast responding surge current diversion components ■ ANSI/UL 1449 Third Edition Optional Enclosure Glass-Filled Polycarbonate Base Cover Molded in Clear Polycarbonate Series Blocking Inductor voltage blocking current soothing inductor Pulse Capacitor high-frequency noise absorption DIN Rail Mountable mounts to standard 35 mm industrial DIN rail; rotates 90° for mounting flexibility Knockouts for 1/2" and 3/4" hubs 10 kA Occurrences at 500 Amps ■ “Power ON” indicator NEMA-4X 120 VAC 50/60 Hz Output Current Parameter Standard Enclosure Unit Status Indicator green LED monitors the operational status of the Elite Series Bosses for 6 BZ x 3/8" Self-Tapping Screws >50 Maximum Protection—Total Insulation Common Mode (L-G) (N-G) Corrosion Resistant Resists Temperature of 248°F IEEE 587 CAT A Ring* 172 V 280 V Flammability Rating UL94-5V IEEE 587 CAT B Ring* 205 V 280 V IEEE 587 CAT B Impulse* 330 V 360 V Nominal Outside dimensions (Inches) How to Specify the Appropriate Model H= 6.89, W=6.89, D=2.95 Connection Diagram *Measured from zero volts, 90° Phase angle General Technical Specifications Signal Line Signal Protector Technology AC Protector Technology Peak Surge Current Response Time Voltage Clamp (customer selected) Series Resistance 18 GDT, PTC, SAD MOV, Fuse 10 kA Ordering Information These blocks are for PC642 VoltageSelection if applicable. See PC 642 Datasheet for additional information. 0 3 6 L C is standard for 4-20 mA Signal Line. <1 Nanosecond 8–200 Volts 5 ! (Typical) 7 Filtering/Line Conditioning Data/Signal Line Protection Edco™ RM-CAT6-POE Series CAT6-POE Channel Rackmount Islatrol IC+/LRIC+ Series ™ The Edco™ RM-CAT6-POE Series is a multi-channel high-speed data line protector Active Tracking Filter™ that utilizes a three-stage hybrid design technology. This unit addresses high- Series connected high-frequency noise filter with transient protection. Offers energy voltage transients that can damage expensive computer equipment. Ideal the flexibility of either receptacle/line cord connection or hard-wired connection for network switches and hubs, the Edco™ RM-CAT6-POE Series is easily mounted to critical loads (up to 30 Amperes). Applications include industrial or office in close proximity to the protected equipment. equipment, computers placed in harsh environments. Features ■ Low insertion loss ■ Exceeds category 6 transmission values ■ Three stage hybrid ■ Compact 1U rack size ■ 1 year warranty ■ Meets Power-Over-Ethernet (POE) requirements ■ Replaceable surge modules Features ■ Typically reduces normal mode transients to +/-2 volts ■ Surge current capacity — 45,000 Amps ■ LED power indication ■ 10 year warranty ■ Transient protection in all modes: line to neutral, line to ground, and neutral to ground General Technical Specifications Operating Voltage 57 V Clamping Voltage 68 V Transmission Speed MCOV Typical Category A Ringwave (6 kV, 200 A, 100 kHz) 120 Volt 150 VRMS Model Normal 275 VRMS IC+102 / LRIC+102 1.0 / 0.9 302 / 287 Line Frequency 47 - 63 Hz IC+105 / LRIC+105 0.7 / 0.8 292 / 307 IC+107 / LRIC+107 0.7 / 0.7 302 / 293 Response Time Normal Mode < 0.5 ns Common Mode < 5 ns Operating Temperature -40°C to +45°C at Full Load Derate Linearly to 60% at +70ºC 0% to 95% Operating Humidity System Design Common 240 Volt IC+115 / LRIC+115 0.7 / 0.7 304 / 306 IC+130 / IC+202 0.5 / 1.1 306 / 536 IC+205 / IC+207 1.5 / 0.8 628 / 616 IC+215 / IC+230 0.6 / 0.9 572 / 566 Typical Category B Ringwave (6 kV, 500 A, 100 kHz) 10 Mbps, 100 Mbps, 1,000 Mbps Operating Current 0.15 A Connection Means 2-Port Series SPD Technology GDT, SAD, W/Series PTC Series Blocking Inductors voltage blocking current smoothing inductors Shunt Absorbing Components sine wave tracking circuitry Modes of Protection Signal High-Low, Signal High-Ground, Signal Low-Ground Peak Surge Current Mounting Dimensions 10 kA (8 x 20 µs) Insertion Loss <0.1 dB VSWR <1.2 Operating Humidity Painted Steel 1.75Hx19Wx6.3D Weight 5.5 lbs Warranty 1 Year Ordering Information 0-95% Non-Condensing Operating Temperature Rackmount Enclosure Type -40°C to +85°C RM-CAT6-8POE 8 Channels Input Connection Type RJ-45 RM-CAT6-16POE 16 Channels Output Connection Type RJ-45 RM-CAT6-24POE 24 Channels RM-CAT6-48POE 48 Channels Edco™ CX-HFN Series MOV Transient Protection high-energy transient protection line to neutral, line to ground, neutral to ground High Frequency Coax Protector — N-Type The Edco™ CX-HFN surge protectors are designed to protect sensitive electronic Model Normal Common Peak Surge Current Capability (8 x 20 µs) IC+102 / LRIC+102 178 / 188 302 / 285 Line to Neutral 15,000 Amps IC+105 / LRIC+105 162 / 191 291 / 300 Line to Ground 15,000 Amps IC+107 / LRIC+107 173 / 190 300 / 298 Neutral to Ground 15,000 Amps IC+115 / LRIC+115 153 / 149 307 / 309 IC+130 / IC+202 241 / 302 299 / 532 also has a replaceable protection cartridge (CX-RC). The Edco™ CX-HFN Load Surge Current Rating equipment from damage due to excessive voltage or currents generated by Pulse Capacitor high-frequency noise absorption lightning or static build-up. The Edco™ CX-HFN offers low signal loss at frequencies up to 4 gigahertz. The unit 10 mSec 5 x Nominal IC+205 / IC+207 378 / 336 594 / 596 accommodates both bulkhead mount and stud mount. The input and output 1 sec 3 x Nominal IC+215 / IC+230 272 / 342 548 / 578 10 sec 2 x Nominal connections are interchangeable. Packaging • High Impact Plastic Case • Vacuum Impregnated Magnetics • Epoxy Encapsulated Frequency Response (Forward-Reverse) Normal Mode ■ Low signal loss Connection Diagram ■ 5 year warranty General Technical Specifications Ordering Information TM 100 kHz to 50 MHz - 90 dB Min 5 MHz to 50 MHz - 60 dB Min Features Note: All measurements in volts. IEEE test results with no AC applied. Normal mode—L1-N or L1-L2; Common mode—L-G, N-G or L1-G, L2-G. TM Common Mode Operating Voltage 130 VDC Insertion Loss Clamping Voltage (DC Spark Over Voltage) 150 VDC SPD Technology Operating Current Peak Surge Current 1A 10 kA (8 x 20 µs) Maximum Power 10 Watts Impedence 50 Ohms Frequency Range 8 ■ Up to 48 channels available ■ UL 1283, CSA recognized < 0.3 dB to 0.5 dB 2 to 3 GHz Gas Discharge Tube (GDT) Connection Type Female N-Type Operating Temperature -30°C to +85°C Dimensions (Inches) Weight CX-HFN-FF (Female–Female) CX-HFN-FM (Female-Male) 1.25H x .875W x 2.5L 4 oz 0 to 4 GHz 17 Data/Signal Line Protection Filtering/Line Conditioning Islatrol™ IC+/LRIC+ Series Active Tracking Filter™ Edco RJA-RJD Series ™ RJ-45 Telephone/Data Ordering Information Dimensional Diagram The Edco RJA and Edco RJD Series are four pair telephone/data line ™ ™ 120 VAC Models with barrier strip at input and output/with wire leads at input and output (WL) protectors that implement advanced two stage hybrid design. These units B A F address over-voltage transients with silicon breakover devices, while sneak and fault currents are mitigated with PTC technology, which consists of solid C state resettable fuses. The Edco™ RJA and Edco™ RJD Series incorporate RJ-45 female jacks in and out. M DIMOUN EN TING SIO NS D The Edco™ RJA voltage clamp is set for C.O. Trunks and Analog Telephone G E Model Rated Output (Amps) Case Dimensions (In) AxBxC Mounting Flange Dimensions (In) DxExFxG Screw Size Weight (lbs) IC+102 / IC+102WL 2.5 4 x 2.88 x 1.81 4.38 x 2.12 x 5.31 x 0.19 #6 1.0 IC+105 / IC+105WL 5.0 4 x 2.88 x 1.81 4.38 x 2.12 x 5.31 x 0.19 #6 1.3 IC+107 / IC+107WL 7.5 4.75 x 4.75 x 2.35 5.25 x 3.50 x 6.25 x 0.19 #6 2.0 IC+115 / IC+115WL 15 6.25 x 4.75 x 2.35 6.75 x 3.50 x 7.75 x 0.19 #8 3.5 IC+130 / IC+130WL 30 7.75 x 4.75 x 2.35 8.25 x 3.50 x 9.00 x 0.19 #8 6.0 Extensions (with ring in voltage), and the Edco™ RJD voltage clamp is set for 120 VAC Models with 5 foot line cord and single NEMA 5-15 receptacle Digital Extensions (no ring in voltage). Features ■ <1 nanosecond response time ■ Tip and ring to ground protection ■ Solid-state resettable fuses-PTCs ■ CAN/CSA C22.2, No. 226-92 Compliant ■ Silicon breakover technology ■ Low capacitance ■ 4 pair protection ■ Line-to-line protection ■ 5 year warranty Case Dimensions (In) AxBxC Mounting Flange Dimensions (In) DxExFxG Screw Size Weight (lbs) LRIC+102 2.5 4.5 x 3.0 x 1.88 N/A N/A 1.3 LRIC+105 5.0 4.5 x 4.5 x 2.38 N/A N/A 2.0 LRIC+107 7.5 6.0 x 4.5 x 2.38 N/A N/A 2.3 LRIC+115 15 7.5 x 4.5 x 2.38 N/A N/A 4.0 240 VAC Models with barrier strip at input and output/with wire leads at input and output (WL) B ■ UL 497A listed Model Rated Output (Amps) A F C D M DIMOUN EN TING SIO NS G E Model Rated Output (Amps) Case Dimensions (In) AxBxC Mounting Flange Dimensions (In) DxExFxG Screw Weight Size (lbs) IC+202 / IC+202WL 2.5 4 x 2.88 x 1.81 4.38 x 2.12 x 5.31 x 0.19 #6 1.3 IC+205 / IC+205WL 5.0 4.75 x 4.75 x 2.35 5.25 x 3.50 x 6.25 x 0.19 #6 2.0 IC+207 / IC+207WL 7.5 6.25 x 4.75 x 2.35 6.75 x 3.50 x 7.75 x 0.19 #8 3.3 IC+215 / IC+215WL 15 7.75 x 4.75 x 2.35 8.25 x 3.50 x 9.00 x 0.19 #8 5.8 IC+230 / IC+230WL 30 7.75 x 4.75 x 2.35 8.25 x 3.50 x 9.00 x 0.19 #8 6.0 Islatrol™ Active Tracking Filters™ carry a 10 year warranty General Technical Specifications Ordering Information Operating Voltage 48, 220 VDC Analog Phone RJA-45 Clamping Voltage 55, 280 VDC Digital Phone RJD-45 Operating Current 0.15 A Peak Surge Current Frequency Range Insertion Loss SPD Technology Connection Type Operating Temperature Dimensions (Inches) Weight Certifications 16 Installation 200 A (10 x 1000 µs) 0 to 50 MHz < 0.1 dB at 50 MHz Silicon Breakover Devices w/Series PTC RJ-45 Jacks -40°C to +85°C 1.0H x 2.5W x 4.25L 3 oz UL 497A, CUL, The Edco™ RJA and Edco™ RJD Series are intended for indoor use only and shall be employed on the equipment side of a listed primary telephone protector. 9 Filtering/Line Conditioning Data/Signal Line Protection Edco™ PHC Series Islatrol™ — SP-6TVN Two-Pair Signaling Circuit Protector (Modular) Industrial Strength Surge Suppression (Series) The Edco™ PHC Series is designed to protect two pairs of wires specifically for The Islatrol™ SP-6TVN plug-in unit is an Active Tracking Filter™ which plugs into alarm and security systems where operating currents can be as high as 5 Amps. a standard duplex receptacle. It features uniquely designed repositionable Electrically, the Edco™ PHC Series is a rugged series hybrid implementing a outlets for easy installation behind desks and other furniture. It protects staged complement of MOVs, copper wound inductors and Silicon Avalanche sensitive home or office equipment from damaging power disturbances Diodes. This design reduces series resistance to 0.2 Ohms per pair. These traveling through wiring to electrical outlets. products are intended to mate with an Edco PCB1B-WKEY gold-plated female terminal connector. The Edco™ PHC modules plug into a base assembly (Edco™ PCB1B-WKEY). The base assembly can be mounted to any flat surface and should be located as close Features Repositionable Outlets as practical to the protected equipment. Terminal 1 and/or terminal 10 should ■ Plugs into standard 120 V, 15 Amp electrical outlet ■ Perfect for tight spaces, behind furniture and appliances ■ Total peak surge current capacity of 39,000 Amps ■ Intelligent monitoring against improper wiring/grounding ■ Cables for telephone, video, and data connections ■ 60 dB maximum high frequency ■ Three-stage protection ■ Continuous current up to 5 Amps ■ Operational indicator lamp ■ Differential protection ■ UL 497B listed ■ 5 year limited warranty ■ Common mode protection ■ Requires Edco ™ PCB1B-WKEY base ■ Plug-in module ■ PC642PTU (Pass Thru Unit) available for troubleshooting ■ Repositionable outlets rotate to accommodate available space be connected to Building-Approved Ground with 12 or 10 gauge solid wire. Features EDCO PCB1B-WKEY BASE SOLD SEPARATELY ■ Automatic recovery General Technical Specifications ■ Fast response time AC Power Protection VPR L-N:330V, L-G:400V, N-G:400V Nominal Operating Voltage 120 VAC, Single Phase Operating Voltage Range 120 VAC +/- 10% Operating Frequency Range 47 — 63 Hz Rated Output (Amps) 15 Amperes ANSI/IEEE C62.41 Category Connection Type 265 V Common Mode 290 V ANSI/IEEE C62.41 Cat B Ringwave (6 kV, 500 A, 100 kHz) Normal Mode 275 V Common Mode 290 V Category A & B (6) 5-15R Receptacles and 5-15P Plug Phase Configuration 2 Wire + Gnd Size High Impact Plastic Weight Common Mode L — N, L — G, N — G Indication of Suppression Status Status Indicator Response Time Warranty Maximum Continuous Operating Voltage (MCOV) Line to Neutral 5 Year Connection Type Cables Provided Peak Surge Current Capacitance Protection Level 130 VAC Clamping Voltage (DC) Attenuation Peak Surge Current (8 x 20 ms) Line to Neutral 13,000 Amps Line to Ground 13,000 Amps Neutral to Ground 13,000 Amps Total 39,000 Amps 36-70 VDC Clamping Voltage 43-100 VDC Operating Current 40 dB Maximum, forward/reverse, 5 MHz to 50 MHz Video 1 & 2 Phone Network Type “F” Type RJ-11 Type RJ-45 6' (2x) Type “F” 6' Ends 6' RJ-11 Male 6' Ends 6' RJ-45 Male Ends 5 kA (8 x 20 µs) 2 kA (10 x 1000 µs) 3 kA (8 x 20 µs) <12 pf <50 pf <70 pf L-G T-R, T-G, R-G L-G (8 Lines) 145 V 270-350 V 30 V 1 dB @ 2 Ghz N/A N/A -WKEY Ordering Information How to Specify the Appropriate Model 5A Peak Surge Current 10 kA (8 x 20 µs) 0 to 10 MHz Insertion Loss < 0.1 dB at 10 MHz SPD Technology Low Voltage Protection < .5 ns Normal Mode ANSI/UL 1449 Third Edition Type 3 Operating Voltage Connection Type 2.0 lbs (0.9 kgs) Modes Of Protection 10 60 dB Maximum, forward/reverse, 100 kHz to 50 MHz Terminal Assignments General Technical Specifications Frequency Range Frequency Response Normal Mode 7.5 x 4.75 x 1.75 (Inches) Enclosure Certifications ANSI/IEEE C62.41 Cat A Ringwave (6 kV, 200 A, 100 kHz) Normal Mode ■ 5 year warranty MOV, SAD, w/Series Inductor Terminal block w/compression lugs Terminals accept up to 10 AWG Operating Temperature Dimensions (Inches) -40°C to +85°C 3.7H x 1.75W x 2.375L (PHC + Mounting Base) Weight DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Dimensions 8 oz Certifications UL 497B Applications Part Number 24V Horn, Strobe, Bell: 70V Speaker Lines: PHC-043 & PCB1B-WKEY PHC-SP70 & PCB1B-WKEY -WKEY 15 Data/Signal Line Protection Filtering/Line Conditioning Edco™ PC642 Series Islatrol™ — RM Series Zone/Loop/Data 120 VAC Rackmount The Edco™ PC642 Series surge suppressor is a two-pair (four-wire) module Islatrol™ RM Series AC rackmount surge protector is ideal for protecting the implementing three-stage hybrid technology. This module addresses power feeding valuable rack equipment. Status LEDs indicate the correct power over-voltage transients with gas tubes and silicon avalanche components. In is coming to the unit, whether the unit is properly grounded and whether the addition, sneak and fault currents are mitigated with resettable fuses (PTCs). surge components are still intact. Units are available with a digital meter, The PTCs increase resistance several orders of magnitude when over-currents mounted on the front of the unit, which will monitor the voltage, current and Model shown: RM-115-10 RM power of the protected equipment. exceed safe levels. A normal state resumes when over-currents are removed. The ability to self-restore in this manner significantly increases suppressor EDCO PCB1B-WKEY BASE SOLD SEPARATELY performance and survivability. The Edco™ PC642 card edge module is gold-plated, double-sided, and is designed to mate with the Edco™ PCB1B-WKEY gold-plated female terminal connector. When snapped together, the data circuits “pass thru” the protector Features in a serial fashion from the four “Field Side” terminals to the four “Electronics ■ 40 kA surge protection ■ Digital meter Side” terminals. Terminals 1 or 10 of the Edco™ PCB1B-WKEY must be attached ■ 60 dB max noise filtering ■ Optional twist lock plug to Building-Approved Ground per Edco™ Technical Bulletin # 2015. ■ 15 & 20 A models available ■ 1 year warranty ■ Power, ground and surge status indicators Features ■ Three-stage hybrid protection ■ Fast response time ■ Sneak/fault current protection ■ Requires Edco ™ PCB1B-WKEY base ■ Resettable fusing — PTCs ■ PC642PTU (Pass Thru Unit) available for troubleshooting ■ Low capacitance option ■ 5 year warranty ■ Plug-in module General Technical Specifications Maximum Continuous Operating Voltage (MCOV) 5-250 VDC Clamping Voltage 8-300 VDC Operating Current 150mA Peak Surge Current Operating Temperature Dimensions (Inches) Weight Certifications -40°C to +85°C 2H x 1W x 2.5L (PC642 + Mounting Base) 14 PC642C-008LC RS423, Token Ring: PC642C-008LC RS232: PC642C-036LC DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Amperage Plug (NEMA) Receptacles (NEMA) Digital Meter Locking Plug 120 V 15 A 5-15P 5-15R Yes No RM-120-10RM 120 V 20 A 5-20P 5-20R Yes No PC642C-030LC-036LC ANSI/UL 1449 Third Edition VPR PC642C-036LC Rated Voltage 24 VAC Power PC642C-043LC Rated Current Peak Surge Current Response Time EMI/RFI Filtering How to Specify the Appropriate Model PC642CLow Capacitance, LC Line to Line, Line to Ground D Line to Line protection only 1 oz Line to Ground 008 036 043 200 Max Operating Voltage Clamping Voltage (1000V@1mA) 5 VDC 30 VDC 36 VDC 43-250 VDC 8 VDC 36 VDC 43 VDC 300 VDC 008, 036, 043 models only 008, 043 models only 200 models only Output Receptacles 15A Models Rackmount AC Power Protection 4–20ma: -WKEY UL 497B Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of supplying more than 150 milliamperes continuously. RS485, RS422: E-NET, 10 BASE T: GDT, SAD, w/Series PTC Terminal block w/compression lugs Terminals accept up to 10 AWG Voltage RM-115-10RM APPLICATION: -WKEY < 0.1 dB at 20 MHz SPD Technology Model Ordering Information 0 to 20 MHz Insertion Loss Connection Type Terminal Assignments 10 kA (8 x 20 µs) Frequency Range General Technical Specifications LED Indicators Digital Meter (Optional) Input Power 15 A Models 20A Models L-N:400 V, L-G:500V, N-G:400V 120 V 15 A & 20 A 20 kA/mode, 40 kA/phase <5 ns 60 dB Max Green-Power on Green-Ground OK Green-Surge Circuit OK 20A Models Thermal Protection Overcurrent Protection Dimensions Certifications Warranty Front- (2) NEMA 5-15R Back- (10) NEMA 5-15R Front- (2) NEMA 5-20R Back- (10) NEMA 5-20R Thermal Protected MOVs Circuit 1.75"H x 19"W x 3.8"D (1U) ANSI/UL 1449 Third Edition Type 3 1 Year Voltage Amps, Watts, VA, Hz, PF, Kwh, and Clock SJT 14/3C Power Cord (9 ft) with NEMA 5-15P Plug SJT 12/3C Power Cord (9 ft) with NEMA 5-20P Plug NEMA L5-20P Plug- Optional 11 Data/Signal Line Protection Data/Signal Line Protection Edco™ DRS (DC) Series Data/Signal Line Protection — Product Selection Guide Find your application in the left column. DIN Rail Protection Then look across for the appropriate product. The Edco™ DRS (DC) Series is a DIN rail mountable, single-pair surge suppression module implementing three-stage hybrid technology. This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak currents are mitigated with resettable fuses (PTCs). The PTCs PRODUCTS APPLICATIONS Edco™ DRS Series Edco™ PC642 Series Edco™ PHC Series Edco™ RJA/RJD Series Edco™ RM-CAT6 Series increase resistance several orders of magnitude when over-currents exceed Edco™ SLAC Series Edco™ SS64/65 Series Edco™ CX Series safe levels. A normal state resumes when over-currents are removed. The ability Edco™ RM-CX06 Series to self-restore in this manner significantly increases suppressor performance and survivability. The Edco™ DRS (DC) Series mounts onto a standard 35 mm industrial DIN rail. There Transmitters are three “Field Side” and three “Electronics Side” screw terminals. One is reserved for a shield. Three electrically tied ground terminals are provided for grounding the Edco™ DRS Series unit to Building-Approved Ground. Shield is isolated from ground. Telephone For a 2-terminal version without a shield, order the Edco™ DRS-XXX-2. Features Industrial Communications Signaling Circuits Programmable Logic Controllers (I/O) Circuits Control Panels (Low Voltage) Communication Rack Equipment ■ Low-voltage data surge protection ■ Easy installation ■ Three-stage hybrid protection ■ Fits standard 35 mm DIN rail ■ Sneak/fault current protection with resettable fuses — PTCs ■ Fast response time < 1 nanosecond ■ Low profile packaging ■ 5 year warranty ■ UL 497B listed General Technical Specifications Part Number Maximum Peak Signal Voltage Nominal Breakdown Voltage Surge 1p 10 x 1000 µs Current Peak Current 8 x 20 µs Waveform Typ Cap (pf) Maximum Continuous Current (ma) Nominal Series Resistance DRS-036 30 36 >100 10 kA 1500 150 5 Ohms **DRS-130 170 200 >10 8 kA 1500 5000 None Dimensional Diagrams **Warning!! DRS-130RMS is for Discrete Signal Use Only. Do not use DRS-130RMS on 120 VAC Power Lines. This unit is a non-hybrid, MOV design, rated above 5 A operational current and can withstand greater than eight occurrences of a 10 kA 8 x 20 µs waveform, and greater than 1000 occurrences of a 200 A 10 x 1000 µs waveform. Video Equipment Video Rack Equipment Water/ Wastewater Instrumentation DRS-XXX DRS-XXX-2 (2 terminal version) 12 13 Data/Signal Line Protection Data/Signal Line Protection Edco™ DRS (DC) Series Data/Signal Line Protection — Product Selection Guide Find your application in the left column. DIN Rail Protection Then look across for the appropriate product. The Edco™ DRS (DC) Series is a DIN rail mountable, single-pair surge suppression module implementing three-stage hybrid technology. This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak currents are mitigated with resettable fuses (PTCs). The PTCs PRODUCTS APPLICATIONS Edco™ DRS Series Edco™ PC642 Series Edco™ PHC Series Edco™ RJA/RJD Series Edco™ RM-CAT6 Series increase resistance several orders of magnitude when over-currents exceed Edco™ SLAC Series Edco™ SS64/65 Series Edco™ CX Series safe levels. A normal state resumes when over-currents are removed. The ability Edco™ RM-CX06 Series to self-restore in this manner significantly increases suppressor performance and survivability. The Edco™ DRS (DC) Series mounts onto a standard 35 mm industrial DIN rail. There Transmitters are three “Field Side” and three “Electronics Side” screw terminals. One is reserved for a shield. Three electrically tied ground terminals are provided for grounding the Edco™ DRS Series unit to Building-Approved Ground. Shield is isolated from ground. Telephone For a 2-terminal version without a shield, order the Edco™ DRS-XXX-2. Features Industrial Communications Signaling Circuits Programmable Logic Controllers (I/O) Circuits Control Panels (Low Voltage) Communication Rack Equipment ■ Low-voltage data surge protection ■ Easy installation ■ Three-stage hybrid protection ■ Fits standard 35 mm DIN rail ■ Sneak/fault current protection with resettable fuses — PTCs ■ Fast response time < 1 nanosecond ■ Low profile packaging ■ 5 year warranty ■ UL 497B listed General Technical Specifications Part Number Maximum Peak Signal Voltage Nominal Breakdown Voltage Surge 1p 10 x 1000 µs Current Peak Current 8 x 20 µs Waveform Typ Cap (pf) Maximum Continuous Current (ma) Nominal Series Resistance DRS-036 30 36 >100 10 kA 1500 150 5 Ohms **DRS-130 170 200 >10 8 kA 1500 5000 None Dimensional Diagrams **Warning!! DRS-130RMS is for Discrete Signal Use Only. Do not use DRS-130RMS on 120 VAC Power Lines. This unit is a non-hybrid, MOV design, rated above 5 A operational current and can withstand greater than eight occurrences of a 10 kA 8 x 20 µs waveform, and greater than 1000 occurrences of a 200 A 10 x 1000 µs waveform. Video Equipment Video Rack Equipment Water/ Wastewater Instrumentation DRS-XXX DRS-XXX-2 (2 terminal version) 12 13 Data/Signal Line Protection Filtering/Line Conditioning Edco™ PC642 Series Islatrol™ — RM Series Zone/Loop/Data 120 VAC Rackmount The Edco™ PC642 Series surge suppressor is a two-pair (four-wire) module Islatrol™ RM Series AC rackmount surge protector is ideal for protecting the implementing three-stage hybrid technology. This module addresses power feeding valuable rack equipment. Status LEDs indicate the correct power over-voltage transients with gas tubes and silicon avalanche components. In is coming to the unit, whether the unit is properly grounded and whether the addition, sneak and fault currents are mitigated with resettable fuses (PTCs). surge components are still intact. Units are available with a digital meter, The PTCs increase resistance several orders of magnitude when over-currents mounted on the front of the unit, which will monitor the voltage, current and Model shown: RM-115-10 RM power of the protected equipment. exceed safe levels. A normal state resumes when over-currents are removed. The ability to self-restore in this manner significantly increases suppressor EDCO PCB1B-WKEY BASE SOLD SEPARATELY performance and survivability. The Edco™ PC642 card edge module is gold-plated, double-sided, and is designed to mate with the Edco™ PCB1B-WKEY gold-plated female terminal connector. When snapped together, the data circuits “pass thru” the protector Features in a serial fashion from the four “Field Side” terminals to the four “Electronics ■ 40 kA surge protection ■ Digital meter Side” terminals. Terminals 1 or 10 of the Edco™ PCB1B-WKEY must be attached ■ 60 dB max noise filtering ■ Optional twist lock plug to Building-Approved Ground per Edco™ Technical Bulletin # 2015. ■ 15 & 20 A models available ■ 1 year warranty ■ Power, ground and surge status indicators Features ■ Three-stage hybrid protection ■ Fast response time ■ Sneak/fault current protection ■ Requires Edco ™ PCB1B-WKEY base ■ Resettable fusing — PTCs ■ PC642PTU (Pass Thru Unit) available for troubleshooting ■ Low capacitance option ■ 5 year warranty ■ Plug-in module General Technical Specifications Maximum Continuous Operating Voltage (MCOV) 5-250 VDC Clamping Voltage 8-300 VDC Operating Current 150mA Peak Surge Current Operating Temperature Dimensions (Inches) Weight Certifications -40°C to +85°C 2H x 1W x 2.5L (PC642 + Mounting Base) 14 PC642C-008LC RS423, Token Ring: PC642C-008LC RS232: PC642C-036LC DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Amperage Plug (NEMA) Receptacles (NEMA) Digital Meter Locking Plug 120 V 15 A 5-15P 5-15R Yes No RM-120-10RM 120 V 20 A 5-20P 5-20R Yes No PC642C-030LC-036LC ANSI/UL 1449 Third Edition VPR PC642C-036LC Rated Voltage 24 VAC Power PC642C-043LC Rated Current Peak Surge Current Response Time EMI/RFI Filtering How to Specify the Appropriate Model PC642CLow Capacitance, LC Line to Line, Line to Ground D Line to Line protection only 1 oz Line to Ground 008 036 043 200 Max Operating Voltage Clamping Voltage (1000V@1mA) 5 VDC 30 VDC 36 VDC 43-250 VDC 8 VDC 36 VDC 43 VDC 300 VDC 008, 036, 043 models only 008, 043 models only 200 models only Output Receptacles 15A Models Rackmount AC Power Protection 4–20ma: -WKEY UL 497B Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of supplying more than 150 milliamperes continuously. RS485, RS422: E-NET, 10 BASE T: GDT, SAD, w/Series PTC Terminal block w/compression lugs Terminals accept up to 10 AWG Voltage RM-115-10RM APPLICATION: -WKEY < 0.1 dB at 20 MHz SPD Technology Model Ordering Information 0 to 20 MHz Insertion Loss Connection Type Terminal Assignments 10 kA (8 x 20 µs) Frequency Range General Technical Specifications LED Indicators Digital Meter (Optional) Input Power 15 A Models 20A Models L-N:400 V, L-G:500V, N-G:400V 120 V 15 A & 20 A 20 kA/mode, 40 kA/phase <5 ns 60 dB Max Green-Power on Green-Ground OK Green-Surge Circuit OK 20A Models Thermal Protection Overcurrent Protection Dimensions Certifications Warranty Front- (2) NEMA 5-15R Back- (10) NEMA 5-15R Front- (2) NEMA 5-20R Back- (10) NEMA 5-20R Thermal Protected MOVs Circuit 1.75"H x 19"W x 3.8"D (1U) ANSI/UL 1449 Third Edition Type 3 1 Year Voltage Amps, Watts, VA, Hz, PF, Kwh, and Clock SJT 14/3C Power Cord (9 ft) with NEMA 5-15P Plug SJT 12/3C Power Cord (9 ft) with NEMA 5-20P Plug NEMA L5-20P Plug- Optional 11 Filtering/Line Conditioning Data/Signal Line Protection Edco™ PHC Series Islatrol™ — SP-6TVN Two-Pair Signaling Circuit Protector (Modular) Industrial Strength Surge Suppression (Series) The Edco™ PHC Series is designed to protect two pairs of wires specifically for The Islatrol™ SP-6TVN plug-in unit is an Active Tracking Filter™ which plugs into alarm and security systems where operating currents can be as high as 5 Amps. a standard duplex receptacle. It features uniquely designed repositionable Electrically, the Edco™ PHC Series is a rugged series hybrid implementing a outlets for easy installation behind desks and other furniture. It protects staged complement of MOVs, copper wound inductors and Silicon Avalanche sensitive home or office equipment from damaging power disturbances Diodes. This design reduces series resistance to 0.2 Ohms per pair. These traveling through wiring to electrical outlets. products are intended to mate with an Edco PCB1B-WKEY gold-plated female terminal connector. The Edco™ PHC modules plug into a base assembly (Edco™ PCB1B-WKEY). The base assembly can be mounted to any flat surface and should be located as close Features Repositionable Outlets as practical to the protected equipment. Terminal 1 and/or terminal 10 should ■ Plugs into standard 120 V, 15 Amp electrical outlet ■ Perfect for tight spaces, behind furniture and appliances ■ Total peak surge current capacity of 39,000 Amps ■ Intelligent monitoring against improper wiring/grounding ■ Cables for telephone, video, and data connections ■ 60 dB maximum high frequency ■ Three-stage protection ■ Continuous current up to 5 Amps ■ Operational indicator lamp ■ Differential protection ■ UL 497B listed ■ 5 year limited warranty ■ Common mode protection ■ Requires Edco ™ PCB1B-WKEY base ■ Plug-in module ■ PC642PTU (Pass Thru Unit) available for troubleshooting ■ Repositionable outlets rotate to accommodate available space be connected to Building-Approved Ground with 12 or 10 gauge solid wire. Features EDCO PCB1B-WKEY BASE SOLD SEPARATELY ■ Automatic recovery General Technical Specifications ■ Fast response time AC Power Protection VPR L-N:330V, L-G:400V, N-G:400V Nominal Operating Voltage 120 VAC, Single Phase Operating Voltage Range 120 VAC +/- 10% Operating Frequency Range 47 — 63 Hz Rated Output (Amps) 15 Amperes ANSI/IEEE C62.41 Category Connection Type 265 V Common Mode 290 V ANSI/IEEE C62.41 Cat B Ringwave (6 kV, 500 A, 100 kHz) Normal Mode 275 V Common Mode 290 V Category A & B (6) 5-15R Receptacles and 5-15P Plug Phase Configuration 2 Wire + Gnd Size High Impact Plastic Weight Common Mode L — N, L — G, N — G Indication of Suppression Status Status Indicator Response Time Warranty Maximum Continuous Operating Voltage (MCOV) Line to Neutral 5 Year Connection Type Cables Provided Peak Surge Current Capacitance Protection Level 130 VAC Clamping Voltage (DC) Attenuation Peak Surge Current (8 x 20 ms) Line to Neutral 13,000 Amps Line to Ground 13,000 Amps Neutral to Ground 13,000 Amps Total 39,000 Amps 36-70 VDC Clamping Voltage 43-100 VDC Operating Current 40 dB Maximum, forward/reverse, 5 MHz to 50 MHz Video 1 & 2 Phone Network Type “F” Type RJ-11 Type RJ-45 6' (2x) Type “F” 6' Ends 6' RJ-11 Male 6' Ends 6' RJ-45 Male Ends 5 kA (8 x 20 µs) 2 kA (10 x 1000 µs) 3 kA (8 x 20 µs) <12 pf <50 pf <70 pf L-G T-R, T-G, R-G L-G (8 Lines) 145 V 270-350 V 30 V 1 dB @ 2 Ghz N/A N/A -WKEY Ordering Information How to Specify the Appropriate Model 5A Peak Surge Current 10 kA (8 x 20 µs) 0 to 10 MHz Insertion Loss < 0.1 dB at 10 MHz SPD Technology Low Voltage Protection < .5 ns Normal Mode ANSI/UL 1449 Third Edition Type 3 Operating Voltage Connection Type 2.0 lbs (0.9 kgs) Modes Of Protection 10 60 dB Maximum, forward/reverse, 100 kHz to 50 MHz Terminal Assignments General Technical Specifications Frequency Range Frequency Response Normal Mode 7.5 x 4.75 x 1.75 (Inches) Enclosure Certifications ANSI/IEEE C62.41 Cat A Ringwave (6 kV, 200 A, 100 kHz) Normal Mode ■ 5 year warranty MOV, SAD, w/Series Inductor Terminal block w/compression lugs Terminals accept up to 10 AWG Operating Temperature Dimensions (Inches) -40°C to +85°C 3.7H x 1.75W x 2.375L (PHC + Mounting Base) Weight DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Dimensions 8 oz Certifications UL 497B Applications Part Number 24V Horn, Strobe, Bell: 70V Speaker Lines: PHC-043 & PCB1B-WKEY PHC-SP70 & PCB1B-WKEY -WKEY 15 Data/Signal Line Protection Filtering/Line Conditioning Islatrol™ IC+/LRIC+ Series Active Tracking Filter™ Edco RJA-RJD Series ™ RJ-45 Telephone/Data Ordering Information Dimensional Diagram The Edco RJA and Edco RJD Series are four pair telephone/data line ™ ™ 120 VAC Models with barrier strip at input and output/with wire leads at input and output (WL) protectors that implement advanced two stage hybrid design. These units B A F address over-voltage transients with silicon breakover devices, while sneak and fault currents are mitigated with PTC technology, which consists of solid C state resettable fuses. The Edco™ RJA and Edco™ RJD Series incorporate RJ-45 female jacks in and out. M DIMOUN EN TING SIO NS D The Edco™ RJA voltage clamp is set for C.O. Trunks and Analog Telephone G E Model Rated Output (Amps) Case Dimensions (In) AxBxC Mounting Flange Dimensions (In) DxExFxG Screw Size Weight (lbs) IC+102 / IC+102WL 2.5 4 x 2.88 x 1.81 4.38 x 2.12 x 5.31 x 0.19 #6 1.0 IC+105 / IC+105WL 5.0 4 x 2.88 x 1.81 4.38 x 2.12 x 5.31 x 0.19 #6 1.3 IC+107 / IC+107WL 7.5 4.75 x 4.75 x 2.35 5.25 x 3.50 x 6.25 x 0.19 #6 2.0 IC+115 / IC+115WL 15 6.25 x 4.75 x 2.35 6.75 x 3.50 x 7.75 x 0.19 #8 3.5 IC+130 / IC+130WL 30 7.75 x 4.75 x 2.35 8.25 x 3.50 x 9.00 x 0.19 #8 6.0 Extensions (with ring in voltage), and the Edco™ RJD voltage clamp is set for 120 VAC Models with 5 foot line cord and single NEMA 5-15 receptacle Digital Extensions (no ring in voltage). Features ■ <1 nanosecond response time ■ Tip and ring to ground protection ■ Solid-state resettable fuses-PTCs ■ CAN/CSA C22.2, No. 226-92 Compliant ■ Silicon breakover technology ■ Low capacitance ■ 4 pair protection ■ Line-to-line protection ■ 5 year warranty Case Dimensions (In) AxBxC Mounting Flange Dimensions (In) DxExFxG Screw Size Weight (lbs) LRIC+102 2.5 4.5 x 3.0 x 1.88 N/A N/A 1.3 LRIC+105 5.0 4.5 x 4.5 x 2.38 N/A N/A 2.0 LRIC+107 7.5 6.0 x 4.5 x 2.38 N/A N/A 2.3 LRIC+115 15 7.5 x 4.5 x 2.38 N/A N/A 4.0 240 VAC Models with barrier strip at input and output/with wire leads at input and output (WL) B ■ UL 497A listed Model Rated Output (Amps) A F C D M DIMOUN EN TING SIO NS G E Model Rated Output (Amps) Case Dimensions (In) AxBxC Mounting Flange Dimensions (In) DxExFxG Screw Weight Size (lbs) IC+202 / IC+202WL 2.5 4 x 2.88 x 1.81 4.38 x 2.12 x 5.31 x 0.19 #6 1.3 IC+205 / IC+205WL 5.0 4.75 x 4.75 x 2.35 5.25 x 3.50 x 6.25 x 0.19 #6 2.0 IC+207 / IC+207WL 7.5 6.25 x 4.75 x 2.35 6.75 x 3.50 x 7.75 x 0.19 #8 3.3 IC+215 / IC+215WL 15 7.75 x 4.75 x 2.35 8.25 x 3.50 x 9.00 x 0.19 #8 5.8 IC+230 / IC+230WL 30 7.75 x 4.75 x 2.35 8.25 x 3.50 x 9.00 x 0.19 #8 6.0 Islatrol™ Active Tracking Filters™ carry a 10 year warranty General Technical Specifications Ordering Information Operating Voltage 48, 220 VDC Analog Phone RJA-45 Clamping Voltage 55, 280 VDC Digital Phone RJD-45 Operating Current 0.15 A Peak Surge Current Frequency Range Insertion Loss SPD Technology Connection Type Operating Temperature Dimensions (Inches) Weight Certifications 16 Installation 200 A (10 x 1000 µs) 0 to 50 MHz < 0.1 dB at 50 MHz Silicon Breakover Devices w/Series PTC RJ-45 Jacks -40°C to +85°C 1.0H x 2.5W x 4.25L 3 oz UL 497A, CUL, The Edco™ RJA and Edco™ RJD Series are intended for indoor use only and shall be employed on the equipment side of a listed primary telephone protector. 9 Filtering/Line Conditioning Data/Signal Line Protection Edco™ RM-CAT6-POE Series CAT6-POE Channel Rackmount Islatrol IC+/LRIC+ Series ™ The Edco™ RM-CAT6-POE Series is a multi-channel high-speed data line protector Active Tracking Filter™ that utilizes a three-stage hybrid design technology. This unit addresses high- Series connected high-frequency noise filter with transient protection. Offers energy voltage transients that can damage expensive computer equipment. Ideal the flexibility of either receptacle/line cord connection or hard-wired connection for network switches and hubs, the Edco™ RM-CAT6-POE Series is easily mounted to critical loads (up to 30 Amperes). Applications include industrial or office in close proximity to the protected equipment. equipment, computers placed in harsh environments. Features ■ Low insertion loss ■ Exceeds category 6 transmission values ■ Three stage hybrid ■ Compact 1U rack size ■ 1 year warranty ■ Meets Power-Over-Ethernet (POE) requirements ■ Replaceable surge modules Features ■ Typically reduces normal mode transients to +/-2 volts ■ Surge current capacity — 45,000 Amps ■ LED power indication ■ 10 year warranty ■ Transient protection in all modes: line to neutral, line to ground, and neutral to ground General Technical Specifications Operating Voltage 57 V Clamping Voltage 68 V Transmission Speed MCOV Typical Category A Ringwave (6 kV, 200 A, 100 kHz) 120 Volt 150 VRMS Model Normal 275 VRMS IC+102 / LRIC+102 1.0 / 0.9 302 / 287 Line Frequency 47 - 63 Hz IC+105 / LRIC+105 0.7 / 0.8 292 / 307 IC+107 / LRIC+107 0.7 / 0.7 302 / 293 Response Time Normal Mode < 0.5 ns Common Mode < 5 ns Operating Temperature -40°C to +45°C at Full Load Derate Linearly to 60% at +70ºC 0% to 95% Operating Humidity System Design Common 240 Volt IC+115 / LRIC+115 0.7 / 0.7 304 / 306 IC+130 / IC+202 0.5 / 1.1 306 / 536 IC+205 / IC+207 1.5 / 0.8 628 / 616 IC+215 / IC+230 0.6 / 0.9 572 / 566 Typical Category B Ringwave (6 kV, 500 A, 100 kHz) 10 Mbps, 100 Mbps, 1,000 Mbps Operating Current 0.15 A Connection Means 2-Port Series SPD Technology GDT, SAD, W/Series PTC Series Blocking Inductors voltage blocking current smoothing inductors Shunt Absorbing Components sine wave tracking circuitry Modes of Protection Signal High-Low, Signal High-Ground, Signal Low-Ground Peak Surge Current Mounting Dimensions 10 kA (8 x 20 µs) Insertion Loss <0.1 dB VSWR <1.2 Operating Humidity Painted Steel 1.75Hx19Wx6.3D Weight 5.5 lbs Warranty 1 Year Ordering Information 0-95% Non-Condensing Operating Temperature Rackmount Enclosure Type -40°C to +85°C RM-CAT6-8POE 8 Channels Input Connection Type RJ-45 RM-CAT6-16POE 16 Channels Output Connection Type RJ-45 RM-CAT6-24POE 24 Channels RM-CAT6-48POE 48 Channels Edco™ CX-HFN Series MOV Transient Protection high-energy transient protection line to neutral, line to ground, neutral to ground High Frequency Coax Protector — N-Type The Edco™ CX-HFN surge protectors are designed to protect sensitive electronic Model Normal Common Peak Surge Current Capability (8 x 20 µs) IC+102 / LRIC+102 178 / 188 302 / 285 Line to Neutral 15,000 Amps IC+105 / LRIC+105 162 / 191 291 / 300 Line to Ground 15,000 Amps IC+107 / LRIC+107 173 / 190 300 / 298 Neutral to Ground 15,000 Amps IC+115 / LRIC+115 153 / 149 307 / 309 IC+130 / IC+202 241 / 302 299 / 532 also has a replaceable protection cartridge (CX-RC). The Edco™ CX-HFN Load Surge Current Rating equipment from damage due to excessive voltage or currents generated by Pulse Capacitor high-frequency noise absorption lightning or static build-up. The Edco™ CX-HFN offers low signal loss at frequencies up to 4 gigahertz. The unit 10 mSec 5 x Nominal IC+205 / IC+207 378 / 336 594 / 596 accommodates both bulkhead mount and stud mount. The input and output 1 sec 3 x Nominal IC+215 / IC+230 272 / 342 548 / 578 10 sec 2 x Nominal connections are interchangeable. Packaging • High Impact Plastic Case • Vacuum Impregnated Magnetics • Epoxy Encapsulated Frequency Response (Forward-Reverse) Normal Mode ■ Low signal loss Connection Diagram ■ 5 year warranty General Technical Specifications Ordering Information TM 100 kHz to 50 MHz - 90 dB Min 5 MHz to 50 MHz - 60 dB Min Features Note: All measurements in volts. IEEE test results with no AC applied. Normal mode—L1-N or L1-L2; Common mode—L-G, N-G or L1-G, L2-G. TM Common Mode Operating Voltage 130 VDC Insertion Loss Clamping Voltage (DC Spark Over Voltage) 150 VDC SPD Technology Operating Current Peak Surge Current 1A 10 kA (8 x 20 µs) Maximum Power 10 Watts Impedence 50 Ohms Frequency Range 10 ■ Up to 48 channels available ■ UL 1283, CSA recognized < 0.3 dB to 0.5 dB 2 to 3 GHz Gas Discharge Tube (GDT) Connection Type Female N-Type Operating Temperature -30°C to +85°C Dimensions (Inches) Weight CX-HFN-FF (Female–Female) CX-HFN-FM (Female-Male) 1.25H x .875W x 2.5L 4 oz 0 to 4 GHz 17 Data/Signal Line Protection Filtering/Line Conditioning Edco™ SLAC Series Islatrol™ IE Series AC Power/Signal Active Tracking Filter™ The Edco SLAC Series suppressor is specifically designed to protect electronic ™ instruments used by the water/wastewater industries. It combines hybrid AC power protection and signal line protection in a NEMA-4X polycarbonate case. System Design The AC power suppressor can supply up to 1875 Watts and has a 15 Amp replaceable fuse to prevent overloading of the protective elements. A “Power ON” LED provides visual indication that power is applied to instruments. Signal line protection is accomplished by the Edco™ PC642 Series available in a variety of voltage clamps. Signal current can be monitored by reading the voltage Shunt Absorbing Components line side sine wave tracking circuitry Shunt Absorbing Components load side sine wave tracking circuitry across the 10 V, 1% resistors (TP1 & TP2 or TP3 & TP4). All leads going to the Edco™ SLAC board are terminated by quick disconnect or barrier block Finger Safe Terminals IEC 998 approved terminals connectors to facilitate easy removal for service or replacement. Form C Relay Contacts normally open and normally closed dry contact for remote status monitoring Features ■ Optional twist lock plug lightning & surge suppression for AC power and low-voltage signal lines ■ Test jacks for signal line monitoring ■ Series hybrid AC suppressor/filter ■ Optional stainless steel or fiberglass enclosure ■ Plug-in protection module ■ 15 Amp replaceable fuse General Technical Specifications AC Power Technology Three-Stage Series Hybrid Input Voltage 15 Amps Max. Response Time <5 Nanoseconds Maximum Surge Current (8x20 µs) Normal Mode (L-N) ■ 5 year warranty MOV Array high-energy surge current diversion array providing transient protection line to neutral, line to ground, and neutral to ground Silicon Avalanche Diodes fast responding surge current diversion components ■ ANSI/UL 1449 Third Edition Optional Enclosure Glass-Filled Polycarbonate Base Cover Molded in Clear Polycarbonate Series Blocking Inductor voltage blocking current soothing inductor Pulse Capacitor high-frequency noise absorption DIN Rail Mountable mounts to standard 35 mm industrial DIN rail; rotates 90° for mounting flexibility Knockouts for 1/2" and 3/4" hubs 10 kA Occurrences at 500 Amps ■ “Power ON” indicator NEMA-4X 120 VAC 50/60 Hz Output Current Parameter Standard Enclosure Unit Status Indicator green LED monitors the operational status of the Elite Series Bosses for 6 BZ x 3/8" Self-Tapping Screws >50 Maximum Protection—Total Insulation Common Mode (L-G) (N-G) Corrosion Resistant Resists Temperature of 248°F IEEE 587 CAT A Ring* 172 V 280 V Flammability Rating UL94-5V IEEE 587 CAT B Ring* 205 V 280 V IEEE 587 CAT B Impulse* 330 V 360 V Nominal Outside dimensions (Inches) How to Specify the Appropriate Model H= 6.89, W=6.89, D=2.95 Connection Diagram *Measured from zero volts, 90° Phase angle General Technical Specifications Signal Line Signal Protector Technology AC Protector Technology Peak Surge Current Response Time Voltage Clamp (customer selected) Series Resistance 18 GDT, PTC, SAD MOV, Fuse 10 kA Ordering Information These blocks are for PC642 VoltageSelection if applicable. See PC 642 Datasheet for additional information. 0 3 6 L C is standard for 4-20 mA Signal Line. <1 Nanosecond 8–200 Volts 5 ! (Typical) 7 Filtering/Line Conditioning Data/Signal Line Protection Islatrol™ IE Series Edco™ SS64 & SS65 Series Active Tracking Filter™ Wastewater/Industrial Applications The Islatrol IE is a series-connected DIN or flange mounted high- The Edco™ SS64 and Edco™ SS65 Series suppressors are designed for the water frequency noise filter and surge suppressor. Its ideal applications include and wastewater industry. These multi-stage hybrid suppressors address critical industrial loads drawing up to 20 Amps of continuous current, over-voltage transients with gas tube and silicon avalanche technology. In while typical applications include any microprocessor-based products, addition, sneak and fault currents are mitigated with PTC devices which including industrial PLCs, OEM applications, and motion control systems. consist of solid-state resettable fuses. The units are encapsulated in stainless ™ steel pipe nipples making them suitable for use in severe environments. The Edco™ SS64 models protect a signal pair and the Edco™ SS65 models protect a Features ■ Multi-staged design, combining a unique hybrid clamping network with the active tracking technology of the Islatrol ® family ■ Surge current capacity — 45,000 Amps ■ Transient protection in all modes: line to neutral, line to ground, and neutral to ground signal pair plus the cable shield (drain wire). ■ LED status indication and form C contact for remote indication ■ DIN mountable enclosure ■ ANSI/UL 1449 Third Edition Type 4, 1283, CUL recognized, CE Features ■ 10 year warranty ■ Transient protection for low-voltage signal lines ■ Encapsulated in stainless steel pipe nipples ■ Sneak/fault current protection ■ Protection for one pair (Two wires & shield on SS65) ■ Resettable fusing—PTCs Performance Technical Specifications General Technical Specifications Ordering Information Model Voltage* IE-103 IE-105 IE-110 IE-120 L-N 400V 400V IE-203 IE-205 IE-210 IE-220 L-G 600V 600V N-G L-L 600V N/A 500V N/A MCOV 700V 900V 700V Peak Surge Current Capability (8 x 20 µs) 5 Amps IE-105 120 V 10 Amps IE-110 120 V 20 Amps IE-120 Continuous Current Model 275 VRMS Line Frequency 47 - 63 Hz Terminal Mounting Type DIN/Flange Weight < 3 lbs Voltage* 3 Amps IE-203 Response Time Normal Mode < 0.5 ns 240 V 5 Amps IE-205 Maximum Signal Voltage 28 V Max < 5 ns 240 V 10 Amps IE-210 DC Clamping Level (L-G) 36 V ±l0% -40°C to +45°C 240 V 20 Amps IE-220 DC Clamping Level (L-L) 72 V ±l0% Operating Temperature Derate Linearly to 60% at +70ºC Operating Humidity * All voltage configurations are single phase - 2 wire + gnd. Common Mode 100 kHz to 50 MHz - 90 dB Min 5 MHz to 50 MHz - 60 dB Min Maximum let-thru Voltage: Dimensional Diagram Line-to-Line (10x700 µs) Normal Mode/Common Mode (Zero Volts Bias) 5 Amp 0.7 V/292 V 10 Amp 0.7 V/300 V 20 Amp 0.7 V/300 V 90 V @ 400 A Series Resistance (per conductor) Typical Category A Ringwave (6 kV, 200 A, 100 kHz) 1 V/300 V 44 V @ 400 A Maximum let-thru Voltage: Capacitance: 3 Amp Typical Applications < 1 Nanosecond Line-to-Ground (10x700 µs) 0% to 95% Frequency Response (Forward-Reverse) Normal Mode General Technical Specifications 240 V Common Mode ■ 5 year warranty ■ Automatic recovery Response Time 15,000 Amps 15,000 Amps 120 V 240 Volt 15,000 Amps 45,000 Amps IE-103 120 V Line to Ground Total Model 3 Amps 150 VRMS Line to Neutral Neutral to Ground Continuous Current 120 Volt Connection 1,000V ■ Differential and common mode protection Number of Occurrences 5 V (typical) (L-L) 600 pf typical (L-G) 1200 pf typical 400 @ 500 Amps (10x1000 µs) Typical Category B Ringwave (6 kV, 500 A, 100 kHz) Normal Mode/Common Mode 6 3 Amp 178 V/300 V 5 Amp 162 V/291 V 10 Amp 153 V/300 V 20 Amp 200 V/300 V Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal lines capable of supplying more than 150 milliamperes continuously. 19 Data/Signal Line Protection Filtering/Line Conditioning Edco™ CX Series CCTV & Data Applications/Coax The Edco™ CX06-M & Edco™ CX06-MI Surge Protective Devices (SPDs) implement three-stage hybrid technology. The SPDs address over-voltage transients with a primary Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD) components. Over-current protection, e.g. sneak and Filtering/Line Conditioning — Product Selection Guide Find your application in the left column. Then look across for the appropriate product. fault currents, are mitigated with solid-state resettable fuses — PTCs. The Edco™ CX06-M & Edco™ CX06-MI SPDs are designed in accordance with NFPA 780 PRODUCTS (2004 edition) requirements, with up to 20 kA of surge current capability. The Edco™ CX06-MI model has an isolated ground and is recommended for use at the camera end. APPLICATIONS Features ■ Sneak/fault current protection ■ CX06-MI has an isolated ground ■ Low insertion loss ■ 5 year warranty Islatrol™ IE Series Islatrol™ IC+/LRIC+ Series Islatrol™ SP-6TVN Series Islatrol™ RM Series ■ Shielded case General Technical Specifications Operating Voltage Ordering Information 5 VDC Connection Type Clamping Voltage 6 VDC Operating Temperature Operating Current 0.15 A Dimensions (Inches) Peak Surge Current Frequency Range Insertion Loss SPD Technology 20 kA (8 x 20 µs) 0 to 20MHz < 0.1 dB at 20 MHz Programmable Logic Controllers Weight BNC, 50/75 Ohm Head End -40°C to +85°C Camera End CX06-MI M = 1.5H x 1W x 3.25L MI = 1.5H x 1W x 4L Camera End CX06-MI-SBL M = 2.3 oz Certifications * CX06-M MI = 3 oz UL 497B Control Panels (AC Power) * * Various OEM Equipment * * GDT, SAD, w/Series PTC Edco™ RM-CX06-16R Channel Rackmount The Edco™ RM-CX06-16R Surge Protective Device (SPD) is a 16 channel coax SPD implementing three-stage hybrid technology. The SPD addresses overvoltage transients with a primary Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD) components. Over-current protection, e.g., sneak and fault currents, are mitigated with new solid-state resettable fuses — PTCs. The Edco™ RM-CX06-16R SPD is designed in accordance with NFPA 780 (2004 edition) requirements, with up to 20 kA of surge current capability. Home Entertainment/Office * Features ■ Sneak/fault current protection ■ 16 channel ■ Low insertion loss ■ 1 year warranty ■ Shielded case AC Rack Equipment General Technical Specifications Operating Voltage 5 VDC Frequency Range Clamping Voltage 6 VDC Insertion Loss Operating Current 0.15 A SPD Technology Peak Surge Current 20 20 kA (8 x 20 µs) Connection Type 0 to 100 MHz < 0.1 dB at 20 MHz GDT, SAD, w/Series PTC BNC, 50/75 Ohm Operating Temperature Dimensions (Inches) Weight Certifications -40°C to +85°C 1.75H x 19W x 2.0D (1U) 3.2 lbs UL 497B 5 TVSS/Surge Protective Devices (SPDs) Data/Signal Line Protection Edco EMC-240B 120/240 VAC Low Exposure AC Panel Protection Edco™ CAT6-5POE Series The Edco EMC-240B surge suppressor is designed to protect AC distribution panel circuits or 120V power supplies feeding sensitive electronic equipment. CAT6/CAT5 Power Over Ethernet Electrically, the unit incorporates MOV and thermal fusing technology. The Edco The Edco™ CAT6-5POE Series is designed to work on Category 5 Power-Over- EMC 240B is designed to be installed in parallel on standard single phase Ethernet transmission lines as well as Category 6 applications. Ideal to protect 120VAC (L,N,G) circuits. expensive equipment against surges and transients entering a building on exposed transmission lines. Features ■ Fast response time ■ Operational status indicators ■ 40,000 Amps per phase capacity ■ UL 1449 Third Edition, Type 2 listed ■ Failsafe and fused ■ 5 year warranty General Technical Specifications Operating Voltage 120/240 VAC VPR L-N:600V, L-L:1,200V Fault Current Rating 42 kAIC UL Location Type 2 I-Nominal (kA) Total Peak Surge Current ■ Applications up to 60 VDC @ 300 mA ■ Exceeds CAT5 & 6 transmission values ■ 1 year warranty ■ CAT5 POE compatible Operating Frequency 47-63 Hz EMI Attenuation (100 kHz to 100 MHz) SPD Technology > 40 dB Metal Oxide Varistors (MOVs) Modes of Protection Line-to-Line, Line-to-Neutral 3kA Operating Current Features Operating Temperature Dimensions (Inches) -40°C to +85°C Weight Certifications ■ CAT6 compatible 4.6H x 2.2W x 2.8L 13.5 oz ANSI/UL 1449 Third Edition Type 2, CUL General Technical Specifications Ordering Information NA, Parallel Status Indication Power On & MOVs functional Operating Voltage 60 VDC Connection Type 80 kA (8 x 20 µs) Connection Type Wire Leads Clamping Voltage 65 VDC Operating Temperature Operating Current 300 mA Dimensions (Inches) Peak Surge Current Edco FAS-120AC ™ Frequency Range Insertion Loss 120 VAC Medium Exposure AC Panel Protection SPD Technology 60A (10 x 1000 µs) Weight RJ-45 Jacks RJ-45 (Female-Female) CAT6-5POE-FF -40°C to +85°C 0.8H x 1.0W x 2.3L 1 oz 0 to 250 MHz < 0.1 dB at 20 MHz Silicon Avalanche Diode (SAD) The Edco FAS-120AC surge suppressor is designed to protect AC panel circuits or 120V power supplies feeding sensitive electronic equipment. Electrically the unit incorporates MOV and thermal fusing technology. This device is designed to be installed in parallel on standard single phase 120VAC (L,N,G) circuits. Installation can be close-nipple up to a distribution panel/circuit or hardwired in parallel up to power supply input terminal screws. Be sure to dress leads as short as possible. Features ■ LED indicator ■ Compact size ■ Fast response time ■ Liquid tight conduit fitting ■ Thermal fuse ■ 5 year warranty ■ L-G, L-N, & N-G protection General Technical Specifications Operating Voltage VPR 120 VAC L-N:700V, L-G:700V, N-G:700V UL Location I-Nominal Operating Current Total Peak Surge Current Operating Frequency 4 Type 2 3 kA EMI Attenuation (100 kHz to 100 MHz) SPD Technology Modes of Protection Line-to-Neutral, Dimensions (Inches) Weight Certifications 2.5H x 1.5W x 3.0L 4.2 oz ANSI/UL 1449 Third Edition Line-to-Ground, Neutral-to-Ground NA, Parallel Status Indication 15.5 kA (8 x 20 µs) Connection Type 47-63 Hz > 25 dB Metal Oxide Varistors (MOVs) Power On & MOV Functional Operating Temperature Wire Leads -40°C to +85°C 21 Technical Bulletins TVSS/Surge Protective Devices (SPDs) DRS Series Technical Bulletins — High-Density Multiple Input Rack The DRS is a modular surge protective device (SPD) that is designed for easy installation in control panels using standard DIN rail mounting brackets. The DRS devices offer both normal and common surge protection up to 40 kA per phase. Features ■ Effectively handles high-energy transients on TT, TN-C, TN-S and TN-C-S three-phase power systems ■ SPD rated Type 2 in accordance with EN 61643-11; Class I & II in accordance with IEC 61643-1 ■ Built-in thermal components disconnect SPD from the power source to avoid thermal runaway conditions ■ MOV only or MOV+Gas Tube models available ■ Fast response time, high surge current capability, low voltage protection levels ■ Visual inspection window on each module indicates status ■ 3-pole terminal provides remote status monitoring ■ DIN rail mounting and plug-in module design allow for easy installation, maintenance and replacement of surge element ■ 5 year warranty TM How to Specify the Appropriate Model Example: DRS 120 3 1 Q Nominal Voltage (Un) (XXX) # of Metal Oxide Varistor Modules* (X) # of Gas Tube Modules** (X) 120 0 0 230 1 1 240 2 277 3 346 4 TM Q *MOV modules are typically one module per phase and may be wired L-N, L-G or N-G. **Gas Tube modules typically used in the N-G mode for type TT grounding systems. ***Certain applications require higher rated components in order to survive frequent voltage rises, in this case order a unit with a “Q” at the end of the part number. 480 TM Higher Rated Voltage*** (Optional) Replacement modules available: Order DRS + Un + M (for MOV) or G (for Gas Tube) TM Performance Technical Specifications DRS12031 TM System Voltage Type of Network DRS27731 DRS34631 120/208, 230/400, 220/380, 277/480, 127/220 VAC 240/415 VAC 254/440 VAC TT-TN TT-TN TT-TN L-N; N-PE L-N; N-PE L-N; N-PE Nominal Voltage Un–120 V Un–230 V Un–277 V Un–346 V Rated Voltage (MCOV) Uc–150 V Uc–320 V Uc–320 V Uc–420 V 1. SLAC UNIT PROVIDES ONE POWER AND TWO SIGNAL PROTECTION CIRCUITS. Nominal Discharge Current (8 x 20 µs) 1n–20 kA 2. SURGE DEVICES SHOULD BE GROUNDED LOCALLY WITH A GROUND ROD, AND ALSO AT THE MAIN PANEL ELECTRICAL GROUND. Maximum Discharge Current Imax–40 kA 3. CHECK WITH EMERSON NETWORK POWER SURGE PROTECTION, INC. TO DETERMINE IF OUTPUT CAN BE SURGE PROTECTED. TT-TN 346/600 VAC Modes of Protection L-N; N-PE NOTES: 1n–20 kA Imax–40 kA Up–1.6 kV 1n–20 kA Imax–40 kA Up—1.6 kV 1n–20 kA Imax–40 kA Up–1.2 kV Response Time TS–25 ns TS–25 ns TS–25 ns TS–25 ns 95% 95% 95% 95% > 103 MV > 103 MV > 103 MV > 103 MV Isolation Resistance Test Standards EN 61643-11 Type 2 IEC61643- 1:1998-02 Class II Mechanical Characteristics Dimensions (Length x Width x Height) 70.8mm x 90.5mm x 68mm I/O Connections By Screw Terminal: 4-25 mm2 By Connection Bus MOV Encapsulation Material Disconnection Indicator Voltage Protection Level Relative Humidity 22 DRS23031 Electrical Characteristics Up–2.0 kV Status Monitoring Mounting Operation Temperature Range Degree of Protection Disconnection Device Housing Material Epoxy Resin Mechanical Indicator Remote Alarm Terminals Symmetrical Rail (EN50022/DIN46277-3) -40°C to +85°C IP 20 Thermal Cutoff System ABS/PA UL94V0 3 Technical Bulletins TVSS/Surge Protective Devices (SPDs) TVSS/SPDs — Product Selection Guide Technical Bulletins — Surge Protection for the Water Industry Find your application in the left column. Then look across for the appropriate product (s). PRODUCTS APPLICATIONS DRS Series TM Edco EMC Series Edco FAS Series TM Facility Service Entrance Distribution Panels TM TM Sub-Distribution Panels Branch Panelboards (Commercial) TM Branch Panelboards (Residential) Motor Control Centers Control Panels (AC Power) NOTES: 1. SLAC UNIT PROVIDES ONE POWER AND TWO SIGNAL PROTECTION CIRCUITS. Various OEM Equipment 2 2. SURGE DEVICES SHOULD BE GROUNDED LOCALLY WITH A GROUND ROD, AND ALSO AT THE MAIN PANEL ELECTRICAL GROUND. 3. CHECK WITH EMERSON NETWORK POWER SURGE PROTECTION, INC. TO DETERMINE IF OUTPUT CAN BE SURGE PROTECTED. 23 Table of Contents Technical Bulletins — Surge Protection for Power and Signal Lines Products Page # TVSS/SURGE PROTECTION DEVICES (SPDs) TVSS/SPDs — Product Selection Guide Emerson Network Power DRS Series Edco EMC-240B — Low Exposure AC Panel Protection Edco FAS-120AC — Medium Exposure AC Panel Protection 2 3 4 4 FILTERING/LINE CONDITIONING TM Filtering/Line Conditioning — Product Selection Guide Islatrol™ IE Series — Active Tracking Filter™ Islatrol™ IC+/LRIC+ Series — Active Tracking Filter™ Islatrol™ — SP-6TVN — Industrial Strength Surge Suppression (Series) Islatrol™ — RM Series — 120 VAC Rackmount TM 5 6, 7 8, 9 10 11 DATA/SIGNAL LINE PROTECTION TM TM Data/Signal Line Protection — Product Selection Guide Edco™ DRS (DC) Series — DIN Rail Protection Edco™ PC642 Series — Zone/Loop/Data Edco™ PHC Series — Two-Pair Signaling Circuit Protector (Modular) Edco™ RJA-RJD Series — RJ-45 Telephone/Data Edco™ RM-CAT6-16POE — CAT6-16POE Channel Rackmount Edco™ CX-HFN-FF/CX-HFN-FM — High Frequency Line Protector — N-Type Edco™ SLAC Series — AC Power/Signal Edco™ SS64 & SS65 Series — Wastewater/Industrial Applications Edco™ CX Series — CCTV & Data Applications/Coax Edco™ RM-CXO6-16R — Channel Rackmount Edco™ CAT6-5 POE Series TECHNICAL BULLETINS High-Density Multiple Input Rack Surge Protection for the Water Industry Surge Protection for Power and Signal Lines Note: Refer to EmersonNetworkPower.com/surge for most current product information. NOTES: 1. SLAC UNIT PROVIDES ONE POWER AND TWO SIGNAL PROTECTION CIRCUITS. 2. SURGE DEVICES SHOULD BE GROUNDED LOCALLY WITH A GROUND ROD, AND ALSO AT THE MAIN PANEL ELECTRICAL GROUND. 3. CHECK WITH EMERSON NETWORK POWER SURGE PROTECTION, INC. TO DETERMINE IF OUTPUT CAN BE SURGE PROTECTED. 24 12 13 14 15 16 17 17 18 19 20 20 21 22 23 24 Power Quality Solutions for ALL Your Application Needs “Dirty” power is a problem. Whether it’s called a surge, spike, transient or noise, “dirty” power is an abnormality in the power that runs your facility. These power problems can leave buildings in the dark and disable equipment, costing you thousands in repairs and lost revenue. Your productivity uptime and reputation depend on consistent power quality. Emerson Network Power Surge Protection provides products and solutions that ensure reliability from Grid to Chip. For more than 40 years, Facility Managers, Engineers, and System Integrators have trusted Emerson Network Power Surge Protection products to protect critical equipment in the Industrial Process, Computing, Research/Testing and Communications fields. Emerson Network Power Surge Protection and the IEEE Standard 1100-1999 (Emerald Book) recommend a properly rated surge protection device should be applied on ALL electrical conductors entering your facility including: power, voice, and data. Without proper protection – data disruption, hardware stress or destruction could occur. As a line of defense against damaging transients, Emerson Network Power Surge Protection manufactures products in the following categories: ■ Surge Protection Devices (SPDs) — which focus on limiting high-voltage spikes to an acceptable level ■ Filtering/Line Conditioning — protect against low-energy transients and high frequency noise and finally… ■ Data/Signal Line Protection — products guard sensitive instrumentation against what we refer to as ‘backdoor’ transients and noise. Why allow “dirty” power to put your equipment at risk? Turn to Emerson Network Power Surge Protection products for peace of mind. We provide solutions for all your application needs and the foundation for Business-Critical Continuity™. Power Switching & Controls For Business-Critical ContinuityTM Grid to Chip Surge Protection Product Catalog Contact Surge Protection 100 Emerson Parkway Binghamton, NY 13905 T: 607-721-8840 (Outside U.S.) T: 800-288-6169 (U.S. & Canada Only) F: 607-722-8713 E: [email protected] Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. EmersonNetworkPower. com/surge AC Power Embedded Computing Infrastructure Management & Monitoring Thermal Management Connectivity DC Power Embedded Power Industrial Power Outside Plant Power Switching & Controls Racks & Integrated Cabinents Service Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2014 Emerson Electric Co. While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. SL-30900 Rev.3 1/14 Printed in USA