Surge Protection For Business-Critical Continuity™ Liebert SS Series Surge Protective Device Approved by Motorola R56 2005 Version, Standards and Guidelines for Communication Sites — Type 1, Type 2 Devices Utilizes advanced SAD/MOV array technology for industry leading transient suppression voltages. Incorporates Liebert’s “state-of-the-art” Interceptor technology for enhanced safety and performance coordination of all surge and fuse components. Modular design for flexibility and ease of servicing. 160 kA surge current capacity for increased reliability. Real-time system monitoring. Product performance and safety standards — ANSI/UL 1449 Third Edition, UL 1283, cUL Listed. Two Different Units Available: Type 1 Hybrid Surge Protection — 20 kA of SAD protection and 160 kA of MOV protection. Type 2 MOV only Surge Protection — 160 kA of MOV protection. Warranty: Covered 24x7 by Emerson Network Power Service Business: 10-Years for Parts, 5-Years On-Site Labor. Typical Applications: Cell Sites. Communication shelters. AC main and distribution panels and load centers. Transmitters. Base Stations. Liebert SS Series Surge Protective Device (SPD) Emerson Network Power MOV/SAD Current Sharing – Type 1 Model The Liebert Answer: MOV Module Surge Current (%) 100.0 90.0 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 SAD Module 0 5000 10000 15000 20000 25000 8/20 µs Surge Current (Amperes) The Liebert SS Series Type I Model offers a true, coordinated multi-stage system of suppression. It integrates the fast response time of the silicon avalanche diode (SAD) with the high-energy capability of the metal oxide varistor (MOV) for increased reliability and performance. This unique 30000 circuitry does not sacrifice the sensitive SAD module when subjected to a damaging high-energy transient event. Technical Specifications Voltage Configurations 120/240V and 120/208V (Please consult factory for additional voltage configurations) Maximum Continuous Operating Voltage (MCOV) ≥125% Fault Current Raiting (AIC) 200kAIC Location Type Type 1 Nominal Discharge Current (In) 20kA Operating Frequency Range 47-63 Hz Connection Parallel (4-6 AWG recommended and 14-1/0 AWG capable); wire lug or disconnect Modes of Protection Line to Neutral/standard Surge Current Capacity 160 kA per mode Response Time <0.5 nanoseconds Dimensions 15.32 in x 13.32 in x 6.60 in Weight 35 lbs. Operating Temperature -40°C to +60°C Status Indication LEDs, Form “C” contacts - 2 sets Form “C” Contact Rating 120VAC, 5.0 amps, pF of 1.0 Certifications ANSI/UL 1449 Third Edition, UL 1283 (Type 2 Locations), cUL Listed Technology Type 1 Hybrid TVSS - 20 kA of SAD protection and 160 kA of MOV protection Type 2 MOV only TVSS - 160 kA of MOV protection Enclosure NEMA 4X; suitable for indoor or outdoor applications Warranty Covered 24x7 by Emerson Network Power Service Business 10-Years Parts and 5-Years On-Site Labor Liebert Corporation World Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 United States Of America 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX Emerson Network Power European Headquarters Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX Emerson Network Power Asia Pacific 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 1605 Philippines +63 2 687 6615 +63 2 730 9572 FAX liebert.com Technical Support 800 288 6169 Toll-Free 607 721 8840 Phone 607 722 8713 Fax While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2010 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. ® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation. SL-22090 (R01/10) Printed in USA Emerson Network Power. The global leader in enabling Business-Critical Continuity™. Clamping Voltage (Vpk) Clamping Voltage (Vpk) Category A Ringwave (6 kV / 0.2 kA) 176 284 Category B Ringwave (6 kV / 0.5 kA) 288 304 ANSI/UL 1449 Third Edition Voltage Protection Rating (VPRs) 600 600 AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Category B Combination Wave (6 kV / 3.0 kA) 304 336 Emerson Network Power.com Category C Combination Wave (20 kV / 10.0 kA) 440 408 Typical NEMA LS1 Data Type 1 Unit; Line - Neutral Type 2 Unit; Line - Neutral 120/208V & 120/240V 120/208V & 120/240V Business-Critical Continuity™, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2010 Emerson Electric Co.