AK-650 series

AK-650 series
650W Single Output Power Supply
Features:
Universal AC input / Full range
Programmable output Voltage (30% ~ 105%)
Programmable output Current (40% ~ 105%)
+5V / 0.5A auxiliary output
Forced current sharing at parallel operation
Power OK signal
Remote ON / OFF, Remote sense function
Protection: OVP, OLP, OTP, SCP, Fan failure
3 years warranty
AK-650-05
MODEL
Output
Input
DC Voltage Range
Rated Current
Current Range
Rated Power
Ripple & Noise (Max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
Voltage Range
Frequency Range
Power Factor (Typ.)
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
Note.2
Note.3
Note.4
Over Load
Protection
Over Voltage
Over Temperature
Auxiliary Power
Remote ON / OFF Control
Power OK Signal
Function
Output Voltage Trim
Output Current Trim
Parallel (Current Sharing) Note.5
Working Temp.
Working Humidity
Environment Storage Temp. & Humidity
Temp. Coefficient
Vibration
Safety Standards
Note.7
Withstand Voltage
Isolation Resistance
Safety & EMC
EMI Conduction & Radiation
Harmonic Current
Note.6 EMS Immunity
MTBF
Cooling
Others
Dimension (WxHxD)
Packing
Note
AK-650-12
AK-650-15
5V
15V
12V
100A
50A
40A
0 ~ 100A
0 ~ 50A
0 ~ 40A
500W
600W
600W
150mVp-p
150mVp-p
150mVp-p
±5.0% Typical adjustment by potentiometer
±1.0%
±0.5%
±0.5%
800ms, 60ms at full load
16ms / 230VAC at full load
90 ~ 264VAC, 127 ~ 370VDC
47 ~ 63Hz
0.98 / 230VAC, 0.99 / 115VAC at full load
83%
88%
88%
AK-650-24
AK-650-27
AK-650-48
24V
27A
0 ~ 27A
648W
150mVp-p
27V
24A
0 ~ 24A
648W
150mVp-p
48V
13.6A
0 ~ 13.6A
652W
150mVp-p
90%
90%
91%
7.5A / 115VAC, 3.5A / 230VAC
27A / 115VAC, 4A / 230VAC
< 1.0mA / 240VAC
105 ~ 125% rated output power
Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
Variable OVP, 125 ±10% Vout.
Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
By detecting primary and secondary heat sink.
Protection type: Shut down o/p voltage (Recovers automatically after temperature goes down)
5V / 0.5A (±3%)
External switch or NPN Transistor to turn ON / OFF
Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
Adjustment of output voltage is between 30 ~ 105% of rated output
Adjustment of output voltage is between 40 ~ 105% of rated output
Please refer to Function Manual
-25 ~ +60°C (Refer to de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C, 10 ~ 95% RH
±0.02% / °C (0 ~ 50°C)
10 ~ 500Hz, 5G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 68-2-6, IEC 68-2-64
Certified UL 60950-1; EN 60950-1
I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC), 1min
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
Certified EN 55022; EN 61000-6-3
Certified EN 61000-3-2; EN 61000-3-3
Certified EN 55024; EN 61204-3; EN 61000-6-1; ENV 50204; IEC 61000-4-2, 3, 4, 5, 6, 8, 11
166.2K HRS Certified MIL-HDBK-217F
Load and Temperature control fan
127x40.9x249 mm / 5.000x1.610x9.803 inch
1.8kg; 6pcs / 11.8kg / 0.55CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes setup time tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. In parallel connection, only one unit will operate if the total output load is less than 5% of the rated load condition.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still
meets EMC directives.
REV. D8
13/09/09
7. This test is done without enclosure.
1
AK-650 series
650W Single Output Power Supply
Unit : mm / inch
Mechanical Drawings:
40.9 [1.61]
249 [9.803]
+V
M6
-V
64 [2.52]
Airflow
direction
74 [2.913]
VR1
LED
16
15 CN9
127 [5]
2
1
3-M4 L=3 [0.157]
3
2
1
14 [0.551]
198 [7.795]
37 [1.457]
26.9 [1.059]
20.5 [0.807]
6-M4 (Both Sides) L=6 [0.236]
25 [0.984]
11.5 [0.453]
221 [8.701]
AC Input Terminal
Pin No. Assignment
Pin No. Assignment
1
ACL
2
ACN
3
8 [0.315]
Control pin number assignment (CN9) : JST S16B-PHDSS or equivalent
Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment
5
AUX
13
9
VS+
ENVCI
1
5
5
5
AUX
6
10
GND
GND
VO+
2
14
3
7
15
VSEN+
PAR
P.OK
11
8
16
4
GND
GND
ACI
VO12
Mating Housing
Terminal
PHDR-16VS
SPHD-002T-P05
Function Description of CN9:
Description
Pin No.
Function
1
VS+
Remote voltage sense (+)
2
VO+
Local output voltage sense (+)
3
VS-
Remote voltage sense (–)
4
VO-
Local output voltage sense (–)
5,6
AUX
+5V / 0.5A Auxiliary power
7
EN+
Remote ON/OFF (+)
8,10,12,14
GND
Ground
9
EN-
Remote ON/OFF (-)
11
P.OK
Power OK
13
VCI
V Program
15
PAR
Parallel operation current share
16
ACI
I Program
REV. D8
13/09/09
2
AK-650 series
650W Single Output Power Supply
LED Status:
Green LED
Status
LED Signal
Solid
Power OK
Slow Blink
Power Standby
LED Signal
Red LED
Status
Over Voltage Protection ( OVP )
Fast Blink
Over Load Protection ( OLP )
Output Short Circuit Protection ( SCP )
Solid
Under Voltage Protection ( UVP )
Slow Blink
Over Temperature Protection ( OTP )
Intermittent Blink
Fan Failure
Interlace Blink
Power Failure
De-rating Curve:
Load V.S I/P Voltage
Load V.S Temp.
Ta=25°C
100
100
90
Load (%)
Load (%)
80
60
80
70
60
40
50
20
40
-25
0
10
20
30
40
50
60
70
90
100
110
264
120
Input Voltage (Vac)
Ambient Temperature (°C)
Function Manual:
1. Output Voltage Trim
100
105
100
90
Output Voltage (%)
Output Voltage (%)
90
80
70
60
50
85
80
75
40
30
30
1.2
1.5
2.0
2.5
3.0
3.5
4.0
4.5 4.8
5.6
50
VCI P. OK EN-
EN+ AUX VS-
156
Open
Extemal Resistor (KΩ)
Extemal Voltage (VDC)
PAR
100
VS+
ACI GND GND GND GND AUX VO- VO+
PAR
VCI P. OK EN-
EN+ AUX VS-
VS+
ACI GND GND GND GND AUX VO- VO+
REV. D8
13/09/09
3
AK-650 series
650W Single Output Power Supply
2. Output Current Trim (For Reference Only)
105
100
Output Current (%)
Output Current (%)
100
90
80
70
60
50
80
60
40
40
1.6
2.0
2.5
3.0
3.5
4.0 4.2
4.5
5.0
11.5
Extemal Voltage (VDC)
PAR
VCI P. OK EN-
23
50
200 Open
Extemal Resistor (KΩ)
EN+ AUX VS-
VS+
PAR
ACI GND GND GND GND AUX VO- VO+
VCI P. OK EN-
EN+ AUX VS-
VS+
ACI GND GND GND GND AUX VO- VO+
3. Remote ON/OFF
(A)
(C)
(B)
AUX
AUX
2KΩ
SW
EN+
2KΩ
AUX
2KΩ
EN+
EN+
SW
5V
5V
5V
EN-
EN-
GND
GND
5V
EN-
Tr
L/H
sw
OFF Power OFF
ON
Power ON
(A) Using internal 5V auxiliary source
GND
Tr
L
Power OFF
H
Power ON
sw
OFF Power OFF
ON
Power ON
(C) Using external voltage source
(B) ON / OFF Control by NPN transistor
4. Power OK Signal
*Place an additional capacitor to have a better
performance of auxiliary power operation.
*The grounding of "AUX" power should be
connected to "GND" port. If " V-" is connected
as Grounding, make sure to short the GND
and V- ports.
DC / DC
5V / 0.5A
*
470μF
10V
AUX.
LOAD
REV. D8
13/09/09
4
AK-650 series
650W Single Output Power Supply
5. Remote Sense
6. Local Sense
VO+
VS-
VO-
VS-
AUX
AUX
AUX
AUX
GND
EN+
GND
EN+
GND
EN-
GND
EN-
GND
P. OK
GND
P. OK
GND
VCI
ACI
PAR
16
Load
CN9
VS+
1
2
1
2
CN9
15
16
VS+
VO-
15
16
VO+
Load
15
GND
VCI
ACI
PAR
16
15
15
16
1
2
CN9
15
16
1
2
CN9
15
16
CN9
1
2
1
2
CN9
15
16
7. Current Sharing with Remote Sensing
VO+
VS+
VO+
VS+
VO+
VS+
VO+
VO-
VS-
VO-
VS-
VO-
VS-
VO-
VS+
VS-
AUX
AUX
AUX
AUX
AUX
AUX
AUX
AUX
GND
EN+
GND
EN+
GND
EN+
GND
EN+
GND
EN-
GND
EN-
GND
EN-
GND
EN-
GND
P. OK
GND
P. OK
GND
P. OK
GND
P. OK
GND
VCI
GND
VCI
GND
VCI
GND
VCI
ACI
PAR
ACI
PAR
ACI
PAR
ACI
PAR
VS+
8. Current Sharing with Local Sensing
VO+
VS+
VO+
VS+
VO+
VS+
VO+
VO-
VS-
VO-
VS-
VO-
VS-
VO-
VS-
AUX
AUX
AUX
AUX
AUX
AUX
AUX
AUX
GND
EN+
GND
EN+
GND
EN+
GND
EN+
GND
EN-
GND
EN-
GND
EN-
GND
EN-
GND
P. OK
GND
P. OK
GND
P. OK
GND
P. OK
GND
VCI
GND
VCI
GND
VCI
GND
VCI
ACI
PAR
ACI
PAR
ACI
PAR
ACI
PAR
REV. D8
13/09/09
5
AK-650 series
650W Single Output Power Supply
Installation Instruction:
1. Mounting Directions
1-1 Recommended standard mounting methods:
(a)
(b)
3-M4
L=4mm max.
3-M4
L=4mm max.
3-M4
L=4mm max.
2. Mounting Method
2-1 There are ventilating holes on the front and back side panels,
do not obstruct; allow 50mm at least for air flow.
2-2 The Maximum allowable penetration of screw is 4mm.
Incomplete threading should not be penetrated.
2-3 Recommended the torque of mounting screw:
M4 screw: 1.27N • m (13.0kgf • cm)
More than 50mm
More than 50mm
FAN
Air flow
FAN
REV. D8
13/09/09
6