Conns1 - Polysnap 2010:Conns1 - Polysnap 2005 8/6/10 16:54 Page 125 POLYSNAP® POWER INLET MODULES C14 IEC Inlet - Standard Filter EMI FILTER OPTIONS ᔢ For Polysnap modules BZV03, BZV04, BZV09, BZV10, BZV17, BZV18, BZH09, BZH10, BZH17, BZH18, BZM27, BZM28 ᔢ PX0575 style IEC inlet ᔢ Using PS01/A style filter ᔢ Standard Attenuation Filter Bxxxx/A xx x x / xx Polysnap Part No. Filter Type Rating L/C Circuit Additional Components Polysnap Part No. From Polysnap Selection A = Standard 01 = 1A 1 = Version 1 0 = None From Polysnap Selection 03 = 3A 2 = Version 2 1 = Bleed (R) Resistor 06 = 6A 3 = Version 3 2 = Surge (VDR) Protection 3 = “R” plus “VDR” Rating Version L1 Cx Cy Part No. Example 1 AMP “ “ 1 2 3 2 x 2.8mH 2 x 10mH 2 x 10mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF BZV03/A0120/02 = 3 AMP “ “ 1 2 3 2 x 0.75mH 2 x 1.8mH 2 x 1.8mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF 6 AMP “ “ 1 2 3 2 x 0.3mH 2 x 0.7mH 2 x 0.7mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF 10 AMP “ “ 1 2 3 2 x 0.17mH 2 x 0.35mH 2 x 0.17mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF BZV style Polysnap module with PX0575 IEC power inlet, filter rated at 1 amp, L/C circuit version 2 (L1 = 2 x 10mH, Cx = 1 x 15nF, Cy = 2 x 2.2nF), without bleed resistor or surge protection device fitted, 6.3mm tabs and single pole red neon switch. Filter Specification Max. Working Voltage: 250V a.c. 50-400Hz Earth Leakage Current: <0.35mA (250V. 50Hz) Temperature Range: –25ºC to +85ºC Max. Ambient Temp.: (@ Full Load) 40ºC (derate linearly to 0A @ 85ºC) Test Voltage: 2700V d.c. 2 secs. Lines to Earth 1100V d.c. 2 secs. Live to Neutral Approvals: Attenuation Curves: www.elektron-bulgin.com See PS01/A filter, page 132 125 IEC CONNECTORS 10 = 10A