POLYSNAP® POWER INLET MODULES
C14 IEC Inlet - Standard Filter
EMI FILTER OPTIONS
ᔢ For Polysnap modules BZV03,
BZV04, BZV09, BZV10,
BZV17, BZV18, BZH09,
BZH10, BZH17, BZH18,
BZM27, BZM28
ᔢ PX0575 style IEC inlet
ᔢ Using PS01/A style filter
ᔢ Standard Attenuation Filter
Bxxxx/A xx x x / xx
Polysnap Part No.
Filter Type
Rating
L/C Circuit
Additional
Components
Polysnap Part No.
From Polysnap Selection
A = Standard
01 = 1A
1 = Version 1
0 = None
From Polysnap Selection
03 = 3A
2 = Version 2
1 = Bleed (R) Resistor
06 = 6A
3 = Version 3
2 = Surge (VDR) Protection
3 = “R” plus “VDR”
Rating
Version
L1
Cx
Cy
Part No. Example
1 AMP
“
“
1
2
3
2 x 2.8mH
2 x 10mH
2 x 10mH
1 x 15nF
1 x 15nF
1 x 47nF
2 x 2.2nF
2 x 2.2nF
2 x 2.2nF
BZV03/A0120/02 =
3 AMP
“
“
1
2
3
2 x 0.75mH
2 x 1.8mH
2 x 1.8mH
1 x 15nF
1 x 15nF
1 x 47nF
2 x 2.2nF
2 x 2.2nF
2 x 2.2nF
6 AMP
“
“
1
2
3
2 x 0.3mH
2 x 0.7mH
2 x 0.7mH
1 x 15nF
1 x 15nF
1 x 47nF
2 x 2.2nF
2 x 2.2nF
2 x 2.2nF
10 AMP
“
“
1
2
3
2 x 0.17mH
2 x 0.35mH
2 x 0.17mH
1 x 15nF
1 x 15nF
1 x 47nF
2 x 2.2nF
2 x 2.2nF
2 x 2.2nF
BZV style Polysnap module with PX0575 IEC
power inlet, filter rated at 1 amp, L/C circuit
version 2 (L1 = 2 x 10mH, Cx = 1 x 15nF,
Cy = 2 x 2.2nF), without bleed resistor or surge
protection device fitted, 6.3mm tabs and single
pole red neon switch.
Filter Specification
Max. Working Voltage:
250V a.c. 50-400Hz
Earth Leakage Current:
<0.35mA (250V. 50Hz)
Temperature Range:
–25ºC to +85ºC
Max. Ambient Temp.:
(@ Full Load)
40ºC (derate linearly to 0A @ 85ºC)
Test Voltage:
2700V d.c. 2 secs. Lines to Earth
1100V d.c. 2 secs. Live to Neutral
Approvals:
Attenuation Curves:
www.elektron-bulgin.com
See PS01/A filter, page 132