Specifications Components used in Polysnap® Power Inlet Modules Description Rating DX0928 Neon Indicator 110V or 250V a.c./d.c. working. FX0359 5 x 20mm Fuseholder Max. rating 10A. 250V See also Page 142 PF0011 Power Inlet with Integral 5 x 20mm Fuseholder Max. rating 10A. 250V a.c. See also Page 29 PF0033 Power Inlet with twin Integral 5 x 20mm Fuseholder Max. rating 10A. 250V a.c. See also Page 31 PX0575 Power Inlet, Cold Condition Max. rating 10A. 250V a.c. See also Page 24 PXS575 Suppressed Inlet incorporating 2 x 2.2nF (Y) Capacitors between Lines and Earth Max. rating 10A. 250V a.c. See also Page 134 PXT575 Surge Protected Inlet, Incorporating VDR across Live and Neutral Max. rating 10A. 250V a.c. See also Page 136 PX0595 Power Inlet, Hot Condition Max. rating 10A. 250V a.c. See also Page 33 PX0695 Power Outlet Max. rating 10A. 250V a.c. See also Page 36 PX0783 Shuttered Power Outlet Max. rating 10A. 250V a.c. See also Page 37 VS0001 Voltage Selector marked 120/240V Max. rating 6.3A. 120/240V a.c. See also Page 182 Rocker Switches (except Mini Bezel) Single and Double Pole Non-illuminated and illuminated Max. rating 16A 250V a.c. Resistive, 4A Inductive. High Inrush Current Rocker Switches Single and Double Pole Non-illuminated and illuminated Max. rating 16A Resistive, 4A Inductive 250V a.c. Inrush Current Tolerance: 150A to IEC 65. Rocker Switches (Mini Bezel) Single and Double Pole Non-illuminated and illuminated Max. rating 10A Resistive, 4A Inductive 250V a.c. Type C O N N E C T O R S Note: Components are Approved Individually (where applicable) Please see relevant pages. Rocker Switch Connections 46 Fax: 0181 507 2691 email: [email protected] I E C F u s e d Po w e r I n l e t M o d u l e s Po l y s n a p© ( Ve r t i c a l ) C O N N E C T O R S BZV01/Z0000/01 How to Order BZV xx / xxxxx / xx Type of Inlet 01 = PF0011/63 02 = PF0011/28 15 = PF0033/63 16 = PF0033/28 Filtered or Non Filtered Inlet Z0000 = Non Filtered Axxxx = Standard Bxxxx = Medical Combination of Other Components 01 = S.P. Switch 02 = S.P. Red Neon Switch 03 = Red Neon Indicator Cxxxx = High Performance Standard 08 = S.P. Green Neon Switch Dxxxx = High Performance Medical 46 = S.P. High Inrush Switch For Filtered inlet use 6th to 9th characters from filter ordering code see pages 126-133. E.g. BZV01/A0620/01 Note: For technical details of individual components please see page 46 www.bulgin.co.uk Tel: 0181 594 5588 47 IEC Fused Power Inlet Modules Polysnap® ( Vertical) C O N N E C T O R S BZV01/Z0000/10 How to Order Type of Inlet BZV xx / xxxxx / xx Filtered or Non Filtered Inlet Combination of Other Components 01 = PF0011/63 Z0000 = Non Filtered 03 = Red Neon Indicator 02 = PF0011/28 Axxxx = Standard 10 = D.P. Switch Bxxxx = Medical 11 = D.P. Red Neon Switch Cxxxx = High Performance Standard 12 = D.P. Green Neon Switch Dxxxx = High Performance Medical 13 = D.P. High Inrush Switch 15 = PF0033/63 16 = PF0033/28 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 126-133. E.g. BZV01/A0620/10 Note: For technical details of individual components please see page 46 48 Fax: 0181 507 2691 email: [email protected] IEC Power Inlet Modules Polysnap® ( Vertical) C O N N E C T O R S BZV03/A0120/02 How to Order BZV xx / xxxxx / xx Type of Inlet Filtered or Non Filtered Inlet Combination of Other Components 03 = PX0575/63 Z0000 = Non Filtered 01 = S.P. Switch 04 = PX0575/28 Axxxx = Standard 02 = S.P. Red Neon Switch 05 = PX0595/63 Bxxxx = Medical 06 = PX0595/28 Cxxxx = High Performance Standard 23 = PXS575/63 Dxxxx = High Performance Medical 24 = PXS575/28 Exxxx = Earth Line Choke 03 = Red Neon Indicator 08 = S.P. Green Neon Switch 46 = S.P. High Inrush Switch 25 = PXT575/63 26 = PXT575/28 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 88, 90, 92, 94, 96, 114, 116, 118. E.g. BZV03/A0120/02 Note: For technical details of individual components please see page 46 www.bulgin.co.uk Tel: 0181 594 5588 49 IEC Power Inlet Modules Polysnap® ( Vertical) C O N N E C T O R S BZV04/A0120/04 How to Order BZV xx / xxxxx / xx Type of Inlet Filtered or Non Filtered Inlet Combination of Other Components 03 = PX0575/63 Z0000 = Non Filtered 04 = 2 x FX0359 04 = PX0575/28 Axxxx = Standard 14 = 1 x VS0001 + 1 x FX0359 05 = PX0595/63 Bxxxx = Medical 06 = PX0595/28 Cxxxx = High Performance 37 = 1 x VS0001 + DX0928/110V/RD 23 = PXS575/63 Standard 38 = 1 x VS0001 + DX0928/110V/GN 24 = PXS575/28 Dxxxx = High Performance 39 = 1 x VS0001 + DX0928/250V/RD 25 = PXT575/63 26 = PXT575/28 Medical Exxxx = Earth Line Choke 42 = 1 x FX0359 + DX0928/110V/GN 43 = 1 x FX0359 + DX0928/250V/Red 44 = 1 x FX0359 + DX0928/250V/GN 45 = 1 x FX0359 + Blanking Plate 40 = 1 x VS0001 + DX0928/250V/GN 41 = 1 x FX0359 + DX0928/110V/RD For Filtered inlet use 6th to 9th characters from filter ordering code see pages 88, 90, 92, 94, 96, 114, 116, 118. E.g. BZV04/A0120/04 Note: For technical details of individual components please see page 46 50 Fax: 0181 507 2691 email: [email protected] IEC Power Inlet Modules Polysnap® ( Vertical) BZV03/Z0000/07 How to Order BZV xx / xxxxx / xx Type of Inlet Filtered or Non Filtered Inlet Combination of Other Components 05 = 2 x FX0359 + D.P. Switch 03 = PX0575/63 Z0000 = Non Filtered 04 = PX0575/28 Axxxx = Standard 06 = 2 x FX0359 + D.P. Red Neon Switch Bxxxx = Medical 07 = Cxxxx = High Performance Standard 2 x FX0359 + Red Neon Indicator 09 = 2 x FX0359 + D.P. Green Neon Switch 15 = 1 x VS0001+ 1 x FX0359 +D.P. Switch 16 = 1 x VS0001 + 1 x FX0359 + D.P. Red Neon Switch 17 = 1 x VS0001 + 1 x FX0359 + Red Neon Indicator 18 = 1 x VS0001 + 1 x FX0359 + D.P. Green Neon Switch 19 = 2 x FX0359 + D.P. Red Neon Switch 125V 20 = 2 x FX0359 + D.P. High Inrush Switch 21 = 2 x FX0359 + D.P. High Inrush Green Neon Switch 22 = 2 x FX0359 + D.P. High Inrush Red Neon Switch 25 = 1 x VS0001 + 1 x DX0928/110V/Red + D.P. Switch 26 = 1 x VS0001+ 1 x DX0928/110V/Green + D.P. Switch 05 = PX0595/63 06 = PX0595/28 23 = PXS575/63 24 = PXS575/28 25 = PXT575/63 Dxxxx = High Performance Medical 26 = PXT575/28 Exxxx = Earth Line Choke For Filtered inlet use 6th to 9th characters from filter ordering code see pages 88, 90, 92, 94, 96, 114, 116, 118. E.g. BZV03/A0120/07 27 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. Switch 28 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. Switch 29 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. High Inrush Switch 30 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. High Inrush Switch 31 = 1 x FX0359 + 1 x DX0928/110V/Red + D.P. Switch C O N N E C T O R S 32 = 1 x FX0359 + 1 x DX0928/110V/Green + D.P. Switch 33 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. Switch 34 = 1 x FX0359 + 1 x DX0928/250V/Green + D.P.Switch 35 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. High Inrush Switch 36 = 1 x FX0359 + 1 x DX0928/250V/Green + D.P.High Inrush Switch 47 = 1 x FX0359 + Blanking Plate (Right) + D.P. High Inrush Green Neon Switch 48 = 1 x FX0359 + Blanking Plate (Right) + D.P. Switch Note: For technical details of individual components please see page 46 www.bulgin.co.uk Tel: 0181 594 5588 51 IEC Power Inlet Modules Polysnap® ( Vertical) C O N N E C T O R S BZV09/Z0000/04 How to Order Type of Inlet / Outlet BZV xx / xxxxx / xx Filtered or Non Filtered Inlet Combination of Other Components 09 = PX0575/63+ PX0695/63 10 = PX0575/28+ PX0695/28 17 = PX0575/63+ PX0783/63 18 = PX0575/28+ PX0783/28 Z0000 = Non Filtered 04 = 2 x FX0359 Axxxx = Standard 14 = 1 x VS0001 + 1 x FX0359 Bxxxx = Medical Cxxxx = High Performance Standard Dxxxx = High Performance Medical Exxxx = Earth Line Choke 37 = 1 x VS0001 + DX0928/110V/Red 38 = 1 x VS0001 + DX0928/110V/Green 33 = PXS575/63+ PX0695/63 39 = 1 x VS0001 + DX0928/250V/Red 34 = PXS575/28+ PX0695/28 40 = 1 x VS0001 + DX0928/250V/Green 35 = PXT575/63+ PX0695/63 41 = 1 x FX0359 + DX0928/110V/Red 36 = PXT575/28+ PX0695/28 42 = 1 x FX0359 + DX0928/110/Green 37 = PXS575/63+ PX0783/63 43 = 1 x FX0359 + DX0928/250V/Red 38 = PXS575/28+ PX0783/28 44 = 1 x FX0359 + DX0928/250V/Green 39 = PXT575/63+ PX0783/63 40 = PXT575/28+ PX0783/28 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 88, 90, 92, 94, 96, 114, 116, 118. 45 = 1 x FX0359 + Blanking Plate E.g. BZV09/A0120/04 Note: For technical details of individual components please see page 46 52 Fax: 0181 507 2691 email: [email protected] IEC Power Inlet/Outlet + Circuit Breaker C O N N E C T O R S BZV09/Z0000/49 BZV09/Z0000/51 How to Order BZV xx / xxxxx / xx Circuit Breaker Filtered or Non Filtered Inlet Type of Inlet / Outlet and Bezel Style 09 = PX0575/63+ PX0695/63 Z0000 = Non Filtered 17 = PX0575/63+ PX0783/63 Bxxxx = Medical Axxxx = Standard Cxxxx = High Performance Standard Exxxx = Earth Line Choke 35 = PXT575/63+ PX0695/63 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 88, 90, 92, 94, 96, 114, 116, 118. 37 = PXS575/63+ PX0783/63 39 = PXT575/63+ PX0783/63 List No. 50 = Double Pole Sensing, Snap to Panel Bezel Dxxxx = High Performance Medical 33 = PXS575/63+ PX0695/63 Data 49 = Single Pole Sensing Snap to Panel Bezel 51 = Single Pole Sensing, Screw to Panel Bezel 52 = Double Pole Sensing, Screw to Panel Bezel E.g. BZV09/A0120/49 2 Amp BZVxx/xxxxx/49 BZVxx/xxxxx/50 BZVxx/xxxxx/51 BZVxx/xxxxx/52 Fixing: Push Fit. Push Fit. Flange. Flange. Termination: 6.3 tab. 6.3 tab. 6.3 tab. 6.3 tab. 2A, 2.5A, 3A, 5A, 8A, 10A. Please state current ratings when ordering. Ratings: Insulation Resistance: >103MΩ. (@ 500V d.c.) >103MΩ. (@ 500V d.c.) >103MΩ. (@ 500V d.c.) >103MΩ. (@ 500V d.c.) Thermal Sensing: Single Pole. Double Pole. Single Pole. Double Pole. www.bulgin.co.uk Tel: 0181 594 5588 53 IEC Power Inlet Modules Polysnap® (Horizontal) C O N N E C T O R S BZH01/Z0000/01 How to Order Type of Inlet 01 = PF0011/63 02 = PF0011/28 15 = PF0033/63 16 = PF0033/28 BZH xx / xxxxx / xx Filtered or Non Filtered Inlet Z0000 = Non Filtered Combination of Other Components 01 = S.P. Switch Axxxx = Standard Bxxxx = Medical 02 = S.P. Red Neon Switch Cxxxx = High Performance Standard 03 = Red Neon Indicator Dxxxx = High Performance Medical 08 = S.P. Green Neon Switch 46 = S.P. High Inrush Switch For Filtered inlet use 6th to 9th characters from filter ordering code see pages 126-133. E.g. BZH01/A0620/01 Note: For technical details of individual components please see page 46 54 Fax: 0181 507 2691 email: [email protected] IEC Fused Power Inlet Modules Polysnap® (Horizontal) C O N N E C T O R S BZH01/Z0000/10 How to Order BZH xx / xxxxx / xx Type of Inlet Filtered or Non Filtered Inlet 01 = PF0011/63 Z0000 = Non Filtered 02 = PF0011/28 Axxxx = Standard 15 = PF0033/63 16 = PF0033/28 Bxxxx = Medical Cxxxx = High Performance Standard Dxxxx = High Performance Medical Combination of Other Components 03 = Red Neon Indicator 10 = D.P. Switch 11 = D.P. Red Neon Switch 12 = D.P. Green Neon Switch 13 = D.P. High Inrush Switch For Filtered inlet use 6th to 9th characters from filter ordering code see pages 126-133. E.g. BZH01/A0620/10 Note: For technical details of individual components please see page 46 www.bulgin.co.uk Tel: 0181 594 5588 55 IEC Power Inlet Modules Polysnap® (Horizontal) C O N N E C T O R S BZH09/Z0000/01 How to Order Type of Inlet / Outlet 09 = PX0575/63+ PX0695/63 10 = PX0575/28+ PX0695/28 17 = PX0575/63+ PX0783/63 18 = PX0575/28+ PX0783/28 BZH xx / xxxxx / xx Filtered or Non Filtered Inlet Combination of Other Components Z0000 = Non Filtered 01 = S.P. Switch Axxxx = Standard 02 = S.P. Red Neon Switch Bxxxx = Medical Cxxxx = High Performance Standard Dxxxx = High Performance Medical Exxxx = Earth Line Choke 03 = Red Neon Indicator 08 = S.P. Green Neon Switch 46 = S.P. High Inrush Switch 33 = PXS575/63+ PX0695/63 34 = PXS575/28+ PX0695/28 35 = PXT575/63+ PX0695/63 36 = PXT575/28+ PX0695/28 37 = PXS575/63+ PX0783/63 38 = PXS575/28+ PX0783/28 39 = PXT575/63+ PX0783/63 40 = PXT575/28+ PX0783/28 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 88, 90, 92, 94, 96, 114, 116, 118. E.g. BZH09/A0120/01 Note: For technical details of individual components please see page 46 56 Fax: 0181 507 2691 email: [email protected] IEC Power Inlet Modules Polysnap® (Horizontal) C O N N E C T O R S BZH11/Z0000/10 How to Order BZH xx / xxxxx / xx Type of Inlet / Outlet Filtered or Non Filtered Inlet Combination of Other Components 11 = PF0011/63+ PX0695/63 Z0000 = Non Filtered 12 = PF0011/28+ PX0695/28 Bxxxx = Medical 10 = D.P. Switch Cxxxx = High Performance Standard 11 = D.P. Red Neon Switch Dxxxx = High Performance Medical 12 = D.P. Green Neon Switch 13 = PF0033/63+ PX0695/63 Axxxx = Standard 14 = PF0033/28+ PX0695/28 03 = Red Neon Indicator 13 = D.P. High Inrush Switch 19 = PF0011/63+ PX0783/63 20 = PF0011/28+ PX0783/28 21 = PF0033/63+ PX0783/63 22 = PF0033/28+ PX0783/28 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 126-133. E.g. BZH11/A0620/10 Note: For technical details of individual components please see page 46 www.bulgin.co.uk Tel: 0181 594 5588 57 IEC Power Inlet Modules Polysnap® (Horizontal) C O N N E C T O R S BZH11/Z0000/00 How to Order BZH xx / xxxxx / xx Type of Inlet / Outlet 11 = PF0011/63+ PX0695/63 12 = PF0011/28+ PX0695/28 13 = PF0033/63+ PX0695/63 14 = PF0033/28+ PX0695/28 Filtered or Non Filtered Inlet Z0000 = Non Filtered Combination of Other Components 00 = None. Axxxx = Standard Bxxxx = Medical Cxxxx = High Performance Standard Dxxxx = High Performance Medical 19 = PF0011/63+ PX0783/63 20 = PF0011/28+ PX0783/28 21 = PF0033/63+ PX0783/63 22 = PF0033/28+ PX0783/28 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 126-133. E.g. BZH11/A0620/00 Note: For technical details of individual components please see page 46 58 Fax: 0181 507 2691 email: [email protected] IEC Power Inlet Modules Polysnap® (Mini Bezel) BZM27/Z0000/57B How to Order Type of Inlet 27 = PX0575/63 28 = PX0575/28 29 = PXS575/63 30 = PXS575/28 31 = PXT575/63 BZM xx / xxxxx / xx x Filtered or Non Filtered Inlet Z0000 = Non Filtered Axxxx = Standard Bxxxx = Medical Cxxxx = High Performance Standard Dxxxx = High Performance Medical Exxxx = Earth Line Choke Combination of Other Components 53 = S.P. Switch 4.8mm tab. Marked 0/1 1.0mm = A 54 = S.P. Switch Solder tab. Marked 0/1 1.5mm = B 55 = S.P. Switch illum. Red. 4.8mm tab. 2.0mm = C 56 = S.P. Switch illum. Red. Solder tab. 3.0mm = D 57 = D.P. Switch 4.8mm tab. Marked 0/1 58 = D.P. Switch Solder tab. Marked 0/1 59 = D.P. Switch illum. Red. 4.8mm tab. 60 = D.P. Switch illum. Red. Solder tab. 61 = S.P. Switch illum. Green. 4.8mm tab. 62 = S.P. Switch illum. Green. Solder tab. 63 = D.P. Switch illum. Green. 4.8mm tab. 64 = D.P. Switch illum. Green. Solder tab. 65 = D.P. Switch (High Inrush). 4.8mm tabs. 68 = D.P. Switch (High Inrush). 4.8mm tabs Marked 0/1 (S.P. Format) 32 = PXT575/28 For Filtered inlet use 6th to 9th characters from filter ordering code see pages 88, 90, 92, 94, 96, 114, 116, 118. E.g. BZM27/A0120/57B Panel Thickness C O N N E C T O R S Note: For technical details of individual components please see please see page 46 www.bulgin.co.uk Tel: 0181 594 5588 59