FiltersSection - 2010:FiltersSection - 2010 8/6/10 16:57 Page 136 MAINS FILTERS Base Mounting and Bulkhead BASE MOUNTING ᔢ 1, 3, 6 or 10 Amp Current Rating ᔢ 3 Alternative Circuits ᔢ Optional Additional Components ᔢ 2.8 or 6.3mm tabs Base Mounting PS02/A BULKHEAD MOUNTING ᔢ 1, 3, 6 or 10 Amp Current Rating ᔢ 3 Alternative Circuits ᔢ Optional Additional Components ᔢ 2.8 or 6.3mm tabs Bulkhead Mounting PS03/A IEC CONNECTORS PS02 or PS03/Axx x x /xx Series Rating L/C Circuit Additional Components Tag Type and Configuration PS02/A 01 = 1A 1 = Version 1 0 = None 28 = 2.8mm PS03/A 03 = 3A 2 = Version 2 1 = Bleed (R) Resistor 63 = 6.3mm tabs 06 = 6A 3 = Version 3 2 = Surge (VDR) Protection 10 = 10A 3 = “R” plus “VDR” Specification PS02/Axxxx/xx PS03/Axxxx/xx Part No. Example Max. Working Voltage: 250V a.c. 50-400Hz 250V a.c. 50-400Hz PS02/A0311/28 = Earth Leakage Current: <0.35mA (250V, 50Hz) <0.35mA (250V, 50Hz) Temperature Range: –25ºC to +85ºC –25ºC to +85ºC Max. Ambient Temp.: (@ Full Load) 40ºC (derate linearly to 0A @ 85ºC) 40ºC (derate linearly to 0A @ 85ºC) PS02 series, standard base mounting filter, rated at 3 amperes. L/C circuit version 1, i.e. L1 = 2 x 0.75mH, Cx = 15nF, Cy = 2 x 2.2nF. with bleed resistor fitted, with 2.8mm tabs. Test Voltage: 2700V d.c. 2 secs. Lines to Earth 1100V d.c. 2 secs. Live to Neutral 2700V d.c. 2 secs. Lines to Earth 1100V d.c. 2 secs. Live to Neutral Compliant Compliant Approvals: RoHS 136 www.elektron-bulgin.com FiltersSection - 2010:FiltersSection - 2010 8/6/10 16:57 Page 137 MAINS FILTERS Rating Version L1 Cx Cy 1 AMP “ “ 1 2 3 2 x 2.8mH 2 x 10mH 2 x 10mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF 3 AMP “ “ 1 2 3 2 x 0.75mH 2 x 1.8mH 2 x 1.8mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF 6 AMP “ “ 1 2 3 2 x 0.3mH 2 x 0.7mH 2 x 0.7mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF 10 AMP “ “ 1 2 3 2 x 0.17mH 2 x 0.35mH 2 x 0.17mH 1 x 15nF 1 x 15nF 1 x 47nF 2 x 2.2nF 2 x 2.2nF 2 x 2.2nF Version 1 Version 2 Version 3 PS02/A011x/xxxx PS03/A011x/xxxx PS02/A012x/xxxx PS03/A012x/xxxx PS02/A013x/xxxx PS03/A013x/xxxx PS02/A031x/xxxx PS03/A031x/xxxx PS02/A032x/xxxx PS03/A032x/xxxx PS02/A033x/xxxx PS03/A033x/xxxx PS02/A061x/xxxx PS03/A061x/xxxx PS02/A062x/xxxx PS03/A062x/xxxx PS02/A063x/xxxx PS03/A063x/xxxx PS02/A101x/xxxx PS03/A101x/xxxx PS02/A102x/xxxx PS03/A102x/xxxx PS02/A103x/xxxx PS03/A103x/xxxx www.elektron-bulgin.com IEC CONNECTORS Rating & Version Table PS02/Axxxx/xx & PS03/Axxxx/xx 137