BULGIN PS00

FiltersSection - 2010:FiltersSection - 2010
8/6/10
16:56
Page 134
MAINS FILTERS
Medical IEC Power Inlets Flange and Snap Fit
PANEL MOUNTING
Flange
PS00/B
ᔢ 1, 3, 6 or 10 Amp Current
Rating
ᔢ Medical
ᔢ 3 Alternative Circuits
ᔢ Optional Additional
Components
ᔢ 2.8 or 6.3mm tabs
SNAP FIT
Snap Fit
PS01/B
ᔢ 1, 3, 6 or 10 Amp Current
Rating
ᔢ Medical
ᔢ 3 Alternative Circuits
ᔢ Optional Additional
Components
ᔢ 2.8 or 6.3mm tabs
ᔢ 1, 1.5, 2 or 3mm panels
IEC CONNECTORS
PS00 or PS01/Bxx x x /xx xx
Series
Rating
L/C Circuit
Additional
Components
Tag Type and
Configuration
Panel
Thickness
PS00/B
01 = 1A
1 = Version 1
0 = None
28 = 2.8mm
00 = Flange
PS01/B
03 = 3A
2 = Version 2
1 = Bleed (R) Resistor
63 = 6.3mm tabs 10 = 1.0mm
06 = 6A
3 = Version 3
2 = Surge (VDR) Protection
15 = 1.5mm
3 = “R” plus “VDR”
20 = 2.0mm
10 = 10A
30 = 3.0mm
Specification
PS00/Bxxxx/xx00
PS01/Bxxxx/xxxx
Part No. Example
Max. Working Voltage:
250V a.c. 50-400Hz
250V a.c. 50-400Hz
PS00/B0120/6300 =
Earth Leakage Current:
<100µA (typically 5µA 250V, 50Hz)
<100µA (typically 5µA 250V, 50Hz)
Temperature Range:
–25ºC to +85ºC
–25ºC to +85ºC
Max. Ambient Temp.:
(@ Full Load)
40ºC (derate linearly to 0A @ 85ºC)
40ºC (derate linearly to 0A @ 85ºC)
Test Voltage:
2700V d.c. 2 secs. Lines to Earth
1100V d.c. 2 secs. Live to Neutral
2700V d.c. 2 secs. Lines to Earth
1100V d.c. 2 secs. Live to Neutral
PS00 series, flange fitting, filtered
IEC power inlet, for medical
applications, rated at 1 ampere.
L/C circuit version 2, i.e. L1 = 2
x 10mH, Cx = 15nF, without
bleed resistor or surge protection
device fitted, with 6.3mm tabs.
PX0587, PX0587/SE, PX0588
PX0587, PX0587/SE, PX0588
Compliant
Compliant
Approvals:
Mating Connectors:
RoHS
134
www.elektron-bulgin.com
FiltersSection - 2010:FiltersSection - 2010
8/6/10
16:56
Page 135
MAINS FILTERS
Rating
Version
L1
Cx
1 AMP
“
“
1
2
3
2 x 2.8mH
2 x 10mH
2 x 10mH
1 x 15nF
1 x 15nF
1 x 47nF
3 AMP
“
“
1
2
3
2 x 0.75mH
2 x 1.8mH
2 x 1.8mH
1 x 15nF
1 x 15nF
1 x 47nF
6 AMP
“
“
1
2
3
2 x 0.3mH
2 x 0.7mH
2 x 0.7mH
1 x 15nF
1 x 15nF
1 x 47nF
10 AMP
“
“
1
2
3
2 x 0.17mH
2 x 0.35mH
2 x 0.17mH
1 x 15nF
1 x 15nF
1 x 47nF
Version 1
Version 2
Version 3
PS00/B011x/xxxx
PS01/B011x/xxxx
PS00/B012x/xxxx
PS01/B012x/xxxx
PS00/B013x/xxxx
PS01/B013x/xxxx
PS00/B031x/xxxx
PS01/B031x/xxxx
PS00/B032x/xxxx
PS01/B032x/xxxx
PS00/B033x/xxxx
PS01/B033x/xxxx
PS00/B061x/xxxx
PS01/B061x/xxxx
PS00/B062x/xxxx
PS01/B062x/xxxx
PS00/B063x/xxxx
PS01/B063x/xxxx
PS00/B101x/xxxx
PS01/B101x/xxxx
PS00/B102x/xxxx
PS01/B102x/xxxx
PS00/B103x/xxxx
PS01/B103x/xxxx
www.elektron-bulgin.com
IEC CONNECTORS
Rating & Version Table
PS00/Bxxxx/xx00 & PS01/Bxxxx/xxxx