p074.

R28SERIES
GAS DISCHARGE TUBE
R28 Series
・Quick response for surge
・High surge current capacity
・It canwithstand alternating current.
・Excellent insulation resistance and small capacitance.
・Recommendation of ITU-T conformity.
・Applications
・Home telephone, Business telephone, PBX
・Wireless base station
・Optical transmission equipments
・CATV transmission equipment, Broadcasting equipments
・Fire alarm system, Home security systems
●R28(2-Electrode Arresters)
Test
Model
R28-900-BHL
R28-151-BHL
R28-231-BHL
R28-251-BHL
R28-301-BHL
R28-351-BHL
R28-401-BHL
R28-471-BHL
R28-601-BHL
DC
spark-over
Voltage
100V/s∼
500V/s
(V)
90V±20%
150V±20%
230V±20%
250V±20%
300V±20%
350V±20%
400V±20%
470V±20%
600V±20%
Impulse
spark-over
Voltage
100V/μs
Max.
(V)
450
500
550
600
650
650
700
900
1300
Impulse
discharge
current
8/20μs
(kA)
Alternating
discharge
current
50Hz,/1sec.
10Times
(A)
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Impulse
life test
Insulation
resistance
10/1000μs
100A
(Times)
300
300
300
300
300
300
300
300
300
Min.
Capacitance
Max.
(pF)
(MΩ)
104
104
104
104
104
104
104
104
104
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
●R28(2-Electrode Arresters)High-Voltage Types
Test
Model
R28-801-BHL
R28-102-BHL
R28-152-BHL
R28-242-BJL
R28-302-BKL
R28-362-BKL
R28-402-BKL
R28-452-BKL
DC
spark-over
Voltage
500V/s
(V)
800V±20%
1000V±20%
1500V±20%
2400V±20%
3000V±20%
3600V±20%
4000V±20%
4500V±20%
Impulse
discharge
current
8/20μs
(kA)
10
10
10
10
10
10
10
10
Insulation
resistance
Min.
(MΩ)
Impulse
life test
8/20μs
100A
(Times)
300
300
300
300
300
300
300
300
104
104
104
104
104
104
104
104
Capacitance
Max.
Withstand
Voltage
Test
(pF)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
−
−
−
AC1250V 3sec.
AC1500V 60sec.
AC1800V 3sec.
AC2000V 60sec.
AC2000V 60sec.
Dim : mm
Model
R28-□□□-BHL
R28-□□□-BJL
R28-□□□-BKL
74
A
5.7
6.45
7.9
R38SERIES
GAS DISCHARGE TUBE
●R38(3-Electrode Arresters)
Test
Model
Impulse
spark-over
Voltage
100V/μs
Max.(V)
450
550
600
650
900
1300
Impulse
discharge
current
8/20μs
Alternating
discharge
current
50Hz,/1sec.
10Times
(A)
10
10
10
10
10
10
(kA)
10
10
10
10
10
10
Impulse
life test
Insulation
resistance
10/1000μs
100A(Times)
Min.
Capacitance
Max.
300
300
300
300
300
300
(pF)
(MΩ)
104
104
104
104
104
104
1.5
1.5
1.5
1.5
1.5
1.5
SURGE ABSORBERS
R38-900-BOL
R38-231-BOL
R38-261-BOL
R38-351-BOL
R38-421-BOL
R38-601-BOL
DC
spark-over
Voltage
100V/s∼
500V/s
(V)
90V±20%
230V±20%
260V±20%
350V±20%
420V±20%
600V±20%
Type designation
10/200μs,20kV Surge Wave form
10kV/div
R28−351−B H L
Type of wire
L:With wire
R28-900-BHL Break down Voltage
900V
0.5kV/div
None:Without wire
Length
H:5.7mm
10μs/div
J:6.45mm
1.2/50μs,20kV Surge Wave form
K:7.9mm
O:10.0mm
10kV/div
Type of taping
A:with taping
B:without taping(bulk)
0.5kV/div
DC spark-over Vbltage
351:35×101=350V
Series name
75
R28-231-BHL Break down Voltage
700V