OH100 - Connor

Available at Digi-Key**
www.digikey.com
STRATUM 3E High Stability
Oven Stabilized Oscillator
OH100 Series
OCXO / VCOCXO
2111 Comprehensive Drive
Aurora, Illinois 60505
Phone: 630- 851- 4722
**Not all
available at
Digi-Key
OH100Package
OH100- =
1.0"x1.0"x0.5"
OCXO
Through Hole
Package
11
US Headquarters:
630-851-4722
European Headquarters:
+353-61-472221
Connor-Winfield’s high stability OH100
series are exceptionally precise frequency
standards, excellent for use in cellular base
stations, test equipment, Synchronous
Ethernet, VSAT and Stratum 3E applications
These unique OCXO / VCOCXO oscillators
provide temperature stabilities in the range
of ±5 ppb to ±50 ppb, over the commercial,
extended commercial or the industrial
temperature range. Power requirements are
1.1W over the commercial temperature range
and 1.5W over the industrial temperature
range after warm-up. Additionally, excellent
aging is achieved through the use of
overtone SC cut crystals.
The OH100 series is available with
CMOS logic or Sinewave output along with
Voltage Controlled Option. These oscillators
provide outstanding phase noise that varies
depending on frequency. Allan Variance
specifications are rated for primary reference
standards. Warm up times are on the order of
5 minutes to 0.10 ppm of final frequency.
32
12 CF
3
00
6 1 Hz
0- M
93
1 0 .0
0
74
OH 1
28
25
94
Fax: 630- 851- 5040
www.conwin.com
Description
Features
•Frequency Range: 5 to 40 MHz
•OCXO - Fixed Frequency
•VCOCXO - Voltage Controlled Option
•3.3 Vdc or 5.0 Vdc Operation
•Available Frequency Stabilities:
•±5.0 ppb, ±10.0 ppb, ±20 ppb or ±50 ppb
• Available Temperature Ranges:
0 to 70°C, -20 to 70°C, -20 to 75°C,
-40 to 70°C or -40 to 85°C
• Low Phase Noise / Phase Jitter
• Output: CMOS Logic or Sinewave
• Package: 1.0" x 1.0" x 0.500"
• RoHS Compliant / Lead Free
Ordering Information
6
10
03
C
F
Temperature
Range
Frequency
Stability
Supply Voltage
Output Type
OCXO Type
5 = 0 to 70°C
6 = -40 to 85°C
7 = -20 to 70°C
8 = -40 to 70°C
9 = -20 to 75°C
05 = ±5.0 ppb*
10 = ±10.0 ppb
20 = ±20.0 ppb
50 = ±50.0 ppb
03 = 3.3 Vdc
05 = 5.0 Vdc
C = CMOS
F = Fixed S = Sinewave Freq.
V = Voltage
Controlled
Option
- 010.0M
Output Frequency
Frequency Format
-xxx.xM Min
-xxx.xxxxxxM Max
*Amount of
numbers after the
decimal point.
M = MHz
* ±5.0 ppb stability models are
only available from 0 to 70°C.
Example Part Number:
OH100-61003CF-010.0M = 1.0" x 1.0" x 0.445" package, -40 to 85°C temperature range, ±10.0 ppb frequency stability, 3.3 Vdc supply Bulletin
Page
Revision
Date
Cx205
1 of 4
08
19 Nov 2013
voltage, CMOS square wave output, fixed output frequency OCXO, 10.0 MHz output frequency.
.
OH100-52005CV-010.0M = 1.0" x 1.0" x 0.445" package, 0 to 70°C temperature range, ±20.0 ppb frequency stability, 5.0 Vdc supply voltage, CMOS square wave output, voltage controlled option, VCOCXO, 10.0 MHz output frequency.
.
OH100-71005SV-010.0M = 1.0" x 1.0" x 0.445" package, -20 to 70°C temperature range, ±10.0 ppb frequency stability, 5.0 Vdc supply voltage, Sinewave output, voltage controlled ooption, VCOCXO 10.0 MHz output frequency.
Attention: System Designers please review Application Note AN2093:
System Design Information and Printed Circuit Board Layout Guidelines for OCXO Oscillators.
@ www.conwin.com/technologies.html
2111 Comprehensive Drive
Aurora, Illinois 60505
Phone: 630- 851- 4722
Fax: 630- 851- 5040
www.conwin.com
Parameter
Absolute Maximum Ratings
Storage Temperature
Supply Voltage Control Voltage (Vc)
Operating Supply Voltage 3.3 Vdc (Vcc)
Operating Supply Voltage 5.0 Vdc (Vcc)
Minimum
-55
-0.5
-0.5
3.13
4.75
Nominal
-
-
-
3.30
5.00
Maximum
125
7.0
7.0
3.47
5.25
Units
°C
Vdc
Vdc
Vdc
Vdc
Notes
Absolute Ratings: Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress
ratings only. The functional operation of the device at those or any other conditions beyond those indicated under "recommended operating conditions"
is not implied. Exposure to conditions outside the "recommended operating conditions" for any extended period of time may adversely impact device
reliability and result in failures not covered by warranty.
Parameter
Center Frequency: (Fo)
Operating Temperature Range:
Temperature Code 5
Temperature Code 6
Temperature Code 7
Temperature Code 8
Temperature Code 9
Frequency Calibration: Frequency Stability vs. Change in Temperature:
Stability Code 05
Stability Code 10
Stability Code 20
Stability Code 50
Frequency Stability vs. Load
Frequency Stability vs. Voltage
Aging: Daily:
5 MHz to 20 MHz
>20 MHz to 40 MHz
Aging: First Year:
5 MHz to 20 MHz
>20 MHz to 40 MHz
Lifetime Tolerance: (20 Years)
5 MHz to 20 MHz-
>20 MHz to 40 MHz
Supply Voltage: (Vcc) Voltage Code 03
Voltage Code 05
Power Consumption: Turn-On
0 to 70°C Models
-20 to 70°C Models
-20 to 75°C Models
-40 to 85°C Models
Power Consumption: Steady State @ 25°C
0 to 70°C Models
-20 to 70°C Models
-20 to 75°C Models
-40 to 85°C Models
Phase Jitter: (BW: 10 Hz to Fo/2)
Models Fo: 5 MHz to 20 MHz
Models Fo: >20 MHz to 40 MHz
Short Term Allan Deviation (1s)
Start-Up Time:
Warm Up Time @ 25°C:
Operating Specifications
Minimum
Nominal
Maximum
Units
0
-40
-20
-40
-20
-0.1
-
-
-
-
-
-
70
85
70
70
75
0.1
°C
°C
°C
°C
°C
ppm @ 25°C
-5.0
-10.0
-20.0
-50.0
-2.0
-2.0
-
-
-
-
-
-
5.0
10.0
20.0
50.0
2.0
2.0
ppb
ppb
ppb
ppb
ppb
ppb
1, 2
2
2
2
±5%
±5%
-1.0
-2.0
-
-
1.0
2.0
ppb/day
ppb/day
3
3
-50
-100
-
-
50
100
ppb
ppb
-300
-500
-
-
300
500
ppb
ppb
4
4
3.13
4.75
3.30
5.00
3.47
5.25
Vdc
Vdc
5
5
-
-
-
-
-
-
-
-
3.00
3.20
3.30
3.80
W
W
W
W
6
6
6
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.0E-11
-
-
1.10
1.15
1.20
1.50
1.0
-
-
500
5
W
W
W
W
ps rms
2.0
rms
ms
minutes
6
6
6
6
5
-
40
Notes:
1.±5.0 ppb stability models are only available from 0 to 70°C.
2.Referenced to the frequency measured @ 25°C.
3.At time of shipment after 48 hours of operation.
4.Inclusive of calibration, operating temperature, supply voltage change, load change and 20 years aging.
5.Supply voltage must reach Vcc levels monotonically within a ramp-up time of <12 ms.
6.Measured with Vcc = Nominal, in calm air.
7.Measured @ 25°C, within ±100 ppb, referenced one hour after turn-on
8.To ensure proper operation of VCOCXO's the control voltage input must be biased the nominal control voltage.
Failure to bias the Vc input will cause an unstable output condition..
Specifications subject to change without notification. See Connor-Winfield's website for latest revision. All dimensions in inches. © Copyright 2014 The Connor-Winfield Corporation Not intended for life support applications.
MHz
Bulletin
Page
Revision
Date
Notes
ps rms
7
Cx205
2 of 4
08
19 Nov 2013
2111 Comprehensive Drive
Aurora, Illinois 60505
Phone: 630- 851- 4722
Fax: 630- 851- 5040
www.conwin.com
Phase Noise Characteristics
Typical Phase Noise for OH100-series with CMOS Output Parameter
SSB Phase Noise
5 - 12 MHz
@ 1Hz offset
@ 10Hz offset
@ 100Hz offset
@ 1KHz offset
@ 10KHz offset
@ 100KHz offset
-85
-115
-140
-145
-150
-150
>12- 20 MHz
-80
-110
-135
-140
-150
-150
>20 - 30 MHz >30 - 40 MHz
-70
-100
-125
-140
-150
-150
-65
-95
-120
-140
-150
-150
Units
Notes
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Input Characteristics - Voltage Controlled Option (OCXO Type Code V)
Parameter
Control Voltage Range:
3.3 Vdc Models
5.0 Vdc Models
Frequency Pullability:
Input Impedance
Minimum
Nominal
Maximum
Units
Notes
0.30
0.50
±0.4
100K
1.65
2.50
-
-
3.00
4.50
-
-
V
V
ppm
Ohms
Vcc = 3.3 Vdc
Vcc = 5.0 Vdc
8
Notes
CMOS Output Characteristics (Output Code C)
Parameter
Load Output Voltage:
3.3 Vdc Models High (Voh)
Low (Vol)
5.0 Vdc Models High (Voh)
Low (Vol)
Duty Cycle at 50% of Vcc
Rise / Fall Time: 10% to 90% Spurious Output
Minimum
Nominal
Maximum
Units
3.0
-
4.7
-
45
-
-
-
-
-
-
50
-
-
-
0.4
-
0.4
55
6
-80
V
-
15
-
pF
V
%
ns
dBc
Sinewave Output Characteristics (Output Code S)
Parameter
Load Output Power
Harmonics
Spurious
Minimum
-
+5.0
-
-
Nominal
50
-
-
-
Maximum
-
+10
-30
-80
Units
Ohms
dBm:
dBc
dBc
Notes
Package Characteristics
OH100 Package
Hermetically sealed, resistive welded package with grounded case.
Environmental Characteristics
Shock
500 G’s 1ms, Halfsine, 3 shocks per direction, per MIL-STD 202G, Method 213B Test Condition D.
Sinusoidal Vibration 0.06” D.A. or 10G’s Peak, 10 to 500 Hz, per MIL-STD-202G, Method 204D, Test Condition A.
Random Vibration 5.35 G’s rms. 20 to 2000 Hz per MIL-STD-202G, Method 214,Test Condition 1A, 15 minutes each axis.
Moisture
10 cycles, 95% RH, Per MIL-STD-202G, Method 112.
Marking Permanency Per MIL-STD-202G, Method 215J.
Attachment Method PCB Through Hole Mounted
Resistance to Solder Heat Per MIL-STD-202G, Method 210, Condition E.
Solder Process RoHS compliant, lead free. See solder profile.
Bulletin
Page
Revision
Date
Specifications subject to change without notification. See Connor-Winfield's website for latest revision. All dimensions in inches. © Copyright 2014 The Connor-Winfield Corporation Not intended for life support applications.
Cx205
3 of 4
08
19 Nov 2013
2111 Comprehensive Drive
Aurora, Illinois 60505
Phone: 630- 851- 4722
Fax: 630- 851- 5040
www.conwin.com
Re-Stabilization Time
Off Time
Re stabilization Time
<1 Hour
<6 Hour
<24 Hour
1 to 16 Days
>16 Days
<2 Hours *
<12 Hours *
<48 Hours *
48 Hours + 1/4 Off Time *
<6 Days *
* For a given off time, the time required to meet daily aging, short term stability requirements.
Package Outline
Package Marking
Pin Connections
.500 Max.
(12.70mm)
1232
OH100-61003CF
10.0 MHz
123456789012
123456789012
Pin Connection
1: Output
2: Ground (Case)
3: Voltage Control or N/C
4: N/C
5: Supply Voltage (Vcc)
Date Code (YYWW)
Model Number
Output Frequency
Serial # Barcode
Serial Number
Dimensional Tolerance:
±.005 (.127mm)
Keep Out Area: Under the OCXO is a keep out area, do not place any parts in this area.
Attention: System Designers please review Application Note AN2093:
System Design Information and Printed Circuit Board Layout Guidelines for OCXO Oscillators.
@ www.conwin.com/technologies.html
Test Circuit
Solder Profile
Temperature
260°C
260°C
10 uF
to
100 uF
Voltage
Control
or
N/C
220°C
180°C
N/C
150°C
120°C
15 pF
0.01 uF
0
10 s
Up to 120 s
60 to 90 s
Typical
Typical
Meets IPC/JEDEC J-STD-020C
CMOS Output Waveform
90%
50%
Revision History
Revision
00
01
02
03
04
05
06
07
08
Date
03/01/11
07/27/11
03/22/12
08/22/12
09/18/12
12/07/12 04/03/13
05/13/13 11/19/13
Changes
New issue
Updated power consumption
Added sinewave models
Updated marking information
Added +10 dB Max to sinewave output characteristics
Added application note AN2093 information
Added ±5ppb models
Changed note 5 and removed note from power supply
line, added absolute note
Added Voltage Controlled Option
Specifications subject to change without notification. See Connor-Winfield's website for latest revision. All dimensions in inches. © Copyright 2014 The Connor-Winfield Corporation Not intended for life support applications.
10%
Bulletin
Page
Revision
Date
Cx205
4 of 4