Available at Digi-Key** www.digikey.com STRATUM 3E High Stability Oven Stabilized Oscillator OH100 Series OCXO / VCOCXO 2111 Comprehensive Drive Aurora, Illinois 60505 Phone: 630- 851- 4722 **Not all available at Digi-Key OH100Package OH100- = 1.0"x1.0"x0.5" OCXO Through Hole Package 11 US Headquarters: 630-851-4722 European Headquarters: +353-61-472221 Connor-Winfield’s high stability OH100 series are exceptionally precise frequency standards, excellent for use in cellular base stations, test equipment, Synchronous Ethernet, VSAT and Stratum 3E applications These unique OCXO / VCOCXO oscillators provide temperature stabilities in the range of ±5 ppb to ±50 ppb, over the commercial, extended commercial or the industrial temperature range. Power requirements are 1.1W over the commercial temperature range and 1.5W over the industrial temperature range after warm-up. Additionally, excellent aging is achieved through the use of overtone SC cut crystals. The OH100 series is available with CMOS logic or Sinewave output along with Voltage Controlled Option. These oscillators provide outstanding phase noise that varies depending on frequency. Allan Variance specifications are rated for primary reference standards. Warm up times are on the order of 5 minutes to 0.10 ppm of final frequency. 32 12 CF 3 00 6 1 Hz 0- M 93 1 0 .0 0 74 OH 1 28 25 94 Fax: 630- 851- 5040 www.conwin.com Description Features •Frequency Range: 5 to 40 MHz •OCXO - Fixed Frequency •VCOCXO - Voltage Controlled Option •3.3 Vdc or 5.0 Vdc Operation •Available Frequency Stabilities: •±5.0 ppb, ±10.0 ppb, ±20 ppb or ±50 ppb • Available Temperature Ranges: 0 to 70°C, -20 to 70°C, -20 to 75°C, -40 to 70°C or -40 to 85°C • Low Phase Noise / Phase Jitter • Output: CMOS Logic or Sinewave • Package: 1.0" x 1.0" x 0.500" • RoHS Compliant / Lead Free Ordering Information 6 10 03 C F Temperature Range Frequency Stability Supply Voltage Output Type OCXO Type 5 = 0 to 70°C 6 = -40 to 85°C 7 = -20 to 70°C 8 = -40 to 70°C 9 = -20 to 75°C 05 = ±5.0 ppb* 10 = ±10.0 ppb 20 = ±20.0 ppb 50 = ±50.0 ppb 03 = 3.3 Vdc 05 = 5.0 Vdc C = CMOS F = Fixed S = Sinewave Freq. V = Voltage Controlled Option - 010.0M Output Frequency Frequency Format -xxx.xM Min -xxx.xxxxxxM Max *Amount of numbers after the decimal point. M = MHz * ±5.0 ppb stability models are only available from 0 to 70°C. Example Part Number: OH100-61003CF-010.0M = 1.0" x 1.0" x 0.445" package, -40 to 85°C temperature range, ±10.0 ppb frequency stability, 3.3 Vdc supply Bulletin Page Revision Date Cx205 1 of 4 08 19 Nov 2013 voltage, CMOS square wave output, fixed output frequency OCXO, 10.0 MHz output frequency. . OH100-52005CV-010.0M = 1.0" x 1.0" x 0.445" package, 0 to 70°C temperature range, ±20.0 ppb frequency stability, 5.0 Vdc supply voltage, CMOS square wave output, voltage controlled option, VCOCXO, 10.0 MHz output frequency. . OH100-71005SV-010.0M = 1.0" x 1.0" x 0.445" package, -20 to 70°C temperature range, ±10.0 ppb frequency stability, 5.0 Vdc supply voltage, Sinewave output, voltage controlled ooption, VCOCXO 10.0 MHz output frequency. Attention: System Designers please review Application Note AN2093: System Design Information and Printed Circuit Board Layout Guidelines for OCXO Oscillators. @ www.conwin.com/technologies.html 2111 Comprehensive Drive Aurora, Illinois 60505 Phone: 630- 851- 4722 Fax: 630- 851- 5040 www.conwin.com Parameter Absolute Maximum Ratings Storage Temperature Supply Voltage Control Voltage (Vc) Operating Supply Voltage 3.3 Vdc (Vcc) Operating Supply Voltage 5.0 Vdc (Vcc) Minimum -55 -0.5 -0.5 3.13 4.75 Nominal - - - 3.30 5.00 Maximum 125 7.0 7.0 3.47 5.25 Units °C Vdc Vdc Vdc Vdc Notes Absolute Ratings: Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only. The functional operation of the device at those or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to conditions outside the "recommended operating conditions" for any extended period of time may adversely impact device reliability and result in failures not covered by warranty. Parameter Center Frequency: (Fo) Operating Temperature Range: Temperature Code 5 Temperature Code 6 Temperature Code 7 Temperature Code 8 Temperature Code 9 Frequency Calibration: Frequency Stability vs. Change in Temperature: Stability Code 05 Stability Code 10 Stability Code 20 Stability Code 50 Frequency Stability vs. Load Frequency Stability vs. Voltage Aging: Daily: 5 MHz to 20 MHz >20 MHz to 40 MHz Aging: First Year: 5 MHz to 20 MHz >20 MHz to 40 MHz Lifetime Tolerance: (20 Years) 5 MHz to 20 MHz- >20 MHz to 40 MHz Supply Voltage: (Vcc) Voltage Code 03 Voltage Code 05 Power Consumption: Turn-On 0 to 70°C Models -20 to 70°C Models -20 to 75°C Models -40 to 85°C Models Power Consumption: Steady State @ 25°C 0 to 70°C Models -20 to 70°C Models -20 to 75°C Models -40 to 85°C Models Phase Jitter: (BW: 10 Hz to Fo/2) Models Fo: 5 MHz to 20 MHz Models Fo: >20 MHz to 40 MHz Short Term Allan Deviation (1s) Start-Up Time: Warm Up Time @ 25°C: Operating Specifications Minimum Nominal Maximum Units 0 -40 -20 -40 -20 -0.1 - - - - - - 70 85 70 70 75 0.1 °C °C °C °C °C ppm @ 25°C -5.0 -10.0 -20.0 -50.0 -2.0 -2.0 - - - - - - 5.0 10.0 20.0 50.0 2.0 2.0 ppb ppb ppb ppb ppb ppb 1, 2 2 2 2 ±5% ±5% -1.0 -2.0 - - 1.0 2.0 ppb/day ppb/day 3 3 -50 -100 - - 50 100 ppb ppb -300 -500 - - 300 500 ppb ppb 4 4 3.13 4.75 3.30 5.00 3.47 5.25 Vdc Vdc 5 5 - - - - - - - - 3.00 3.20 3.30 3.80 W W W W 6 6 6 6 - - - - - - - - - - - - - - 1.0E-11 - - 1.10 1.15 1.20 1.50 1.0 - - 500 5 W W W W ps rms 2.0 rms ms minutes 6 6 6 6 5 - 40 Notes: 1.±5.0 ppb stability models are only available from 0 to 70°C. 2.Referenced to the frequency measured @ 25°C. 3.At time of shipment after 48 hours of operation. 4.Inclusive of calibration, operating temperature, supply voltage change, load change and 20 years aging. 5.Supply voltage must reach Vcc levels monotonically within a ramp-up time of <12 ms. 6.Measured with Vcc = Nominal, in calm air. 7.Measured @ 25°C, within ±100 ppb, referenced one hour after turn-on 8.To ensure proper operation of VCOCXO's the control voltage input must be biased the nominal control voltage. Failure to bias the Vc input will cause an unstable output condition.. Specifications subject to change without notification. See Connor-Winfield's website for latest revision. All dimensions in inches. © Copyright 2014 The Connor-Winfield Corporation Not intended for life support applications. MHz Bulletin Page Revision Date Notes ps rms 7 Cx205 2 of 4 08 19 Nov 2013 2111 Comprehensive Drive Aurora, Illinois 60505 Phone: 630- 851- 4722 Fax: 630- 851- 5040 www.conwin.com Phase Noise Characteristics Typical Phase Noise for OH100-series with CMOS Output Parameter SSB Phase Noise 5 - 12 MHz @ 1Hz offset @ 10Hz offset @ 100Hz offset @ 1KHz offset @ 10KHz offset @ 100KHz offset -85 -115 -140 -145 -150 -150 >12- 20 MHz -80 -110 -135 -140 -150 -150 >20 - 30 MHz >30 - 40 MHz -70 -100 -125 -140 -150 -150 -65 -95 -120 -140 -150 -150 Units Notes dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz Input Characteristics - Voltage Controlled Option (OCXO Type Code V) Parameter Control Voltage Range: 3.3 Vdc Models 5.0 Vdc Models Frequency Pullability: Input Impedance Minimum Nominal Maximum Units Notes 0.30 0.50 ±0.4 100K 1.65 2.50 - - 3.00 4.50 - - V V ppm Ohms Vcc = 3.3 Vdc Vcc = 5.0 Vdc 8 Notes CMOS Output Characteristics (Output Code C) Parameter Load Output Voltage: 3.3 Vdc Models High (Voh) Low (Vol) 5.0 Vdc Models High (Voh) Low (Vol) Duty Cycle at 50% of Vcc Rise / Fall Time: 10% to 90% Spurious Output Minimum Nominal Maximum Units 3.0 - 4.7 - 45 - - - - - - 50 - - - 0.4 - 0.4 55 6 -80 V - 15 - pF V % ns dBc Sinewave Output Characteristics (Output Code S) Parameter Load Output Power Harmonics Spurious Minimum - +5.0 - - Nominal 50 - - - Maximum - +10 -30 -80 Units Ohms dBm: dBc dBc Notes Package Characteristics OH100 Package Hermetically sealed, resistive welded package with grounded case. Environmental Characteristics Shock 500 G’s 1ms, Halfsine, 3 shocks per direction, per MIL-STD 202G, Method 213B Test Condition D. Sinusoidal Vibration 0.06” D.A. or 10G’s Peak, 10 to 500 Hz, per MIL-STD-202G, Method 204D, Test Condition A. Random Vibration 5.35 G’s rms. 20 to 2000 Hz per MIL-STD-202G, Method 214,Test Condition 1A, 15 minutes each axis. Moisture 10 cycles, 95% RH, Per MIL-STD-202G, Method 112. Marking Permanency Per MIL-STD-202G, Method 215J. Attachment Method PCB Through Hole Mounted Resistance to Solder Heat Per MIL-STD-202G, Method 210, Condition E. Solder Process RoHS compliant, lead free. See solder profile. Bulletin Page Revision Date Specifications subject to change without notification. See Connor-Winfield's website for latest revision. All dimensions in inches. © Copyright 2014 The Connor-Winfield Corporation Not intended for life support applications. Cx205 3 of 4 08 19 Nov 2013 2111 Comprehensive Drive Aurora, Illinois 60505 Phone: 630- 851- 4722 Fax: 630- 851- 5040 www.conwin.com Re-Stabilization Time Off Time Re stabilization Time <1 Hour <6 Hour <24 Hour 1 to 16 Days >16 Days <2 Hours * <12 Hours * <48 Hours * 48 Hours + 1/4 Off Time * <6 Days * * For a given off time, the time required to meet daily aging, short term stability requirements. Package Outline Package Marking Pin Connections .500 Max. (12.70mm) 1232 OH100-61003CF 10.0 MHz 123456789012 123456789012 Pin Connection 1: Output 2: Ground (Case) 3: Voltage Control or N/C 4: N/C 5: Supply Voltage (Vcc) Date Code (YYWW) Model Number Output Frequency Serial # Barcode Serial Number Dimensional Tolerance: ±.005 (.127mm) Keep Out Area: Under the OCXO is a keep out area, do not place any parts in this area. Attention: System Designers please review Application Note AN2093: System Design Information and Printed Circuit Board Layout Guidelines for OCXO Oscillators. @ www.conwin.com/technologies.html Test Circuit Solder Profile Temperature 260°C 260°C 10 uF to 100 uF Voltage Control or N/C 220°C 180°C N/C 150°C 120°C 15 pF 0.01 uF 0 10 s Up to 120 s 60 to 90 s Typical Typical Meets IPC/JEDEC J-STD-020C CMOS Output Waveform 90% 50% Revision History Revision 00 01 02 03 04 05 06 07 08 Date 03/01/11 07/27/11 03/22/12 08/22/12 09/18/12 12/07/12 04/03/13 05/13/13 11/19/13 Changes New issue Updated power consumption Added sinewave models Updated marking information Added +10 dB Max to sinewave output characteristics Added application note AN2093 information Added ±5ppb models Changed note 5 and removed note from power supply line, added absolute note Added Voltage Controlled Option Specifications subject to change without notification. See Connor-Winfield's website for latest revision. All dimensions in inches. © Copyright 2014 The Connor-Winfield Corporation Not intended for life support applications. 10% Bulletin Page Revision Date Cx205 4 of 4 08 19 Nov 2013