Available at Digi-Key www.digikey.com OH300-EVAL Eval Board Quick Start Guide 2111 Comprehensive Drive Aurora, Illinois 60505 Phone: 630- 851- 4722 Fax: 630- 851- 5040 www.conwin.com Q U I C K S T A R T G U I D E Bulletin Page Revision Date Cx261-EVAL 1 of 1 P00 13 Aug 2014 General Instructions 1.Insert the OH300 unit into the eval board socket • Pin 1 of the OH300 should be oriented to the lower left of the fixture in the view above. • Close the clam-shell cover until it clicks. 2.Connect power • Connect the wired Vcc banana plug from TP3/TP4 to the appropriate 3.3V or 5V power supply capable of supplying ~ 1.2A of current. • Do not use the J5 “VCC” BNC for the power connection. 3.Connect output: • For CMOS outputs, connect the “CMOS OUT” BNC J6 to an oscilloscope or frequency counter input. Use a high impedance probe if possible. • For Sinewave outputs, connect the “RF OUT” BNC J9 using a coaxial cable to a 50ohm scope or frequency counter input. 4.Connect voltage control: • For OH300-series parts with voltage control (VCOCXO) option, connect J10 “CV IN” BNC to the appropriate +1.65Vdc or +2.5Vdc supply. Designator/Label Input/Output Voltage/Logic Type Function TP3/TP4 “Vcc/Gnd” Input +3.3V or +5V Eval Board Power via wire J5 “VCC Shielded” Input +3.3V or +5V Do not use (use hard wired Vcc connection with banana plug instead of this BNC) J6 “CMOS OUT” Output CMOS Buffered CMOS output J8 “VREF” Input N/C Do not use J9 “RF OUT” Output Sinewave Sinewave Output J10 “CV IN” Input +1.65 or +2.5Vdc Control Voltage Input